Test report

FCC ID: N4ZFG400

Test Report

Download: PDF
FCCID_4221607

                             Global United Technology Services Co., Ltd.

                                                                                  Report No.: GTS201903000020F01



                                        FCC Report
    Applicant:                        FLYSKY RC MODEL TECHNOLOGY CO., LTD

    Address of Applicant:             West building3, Huangjianyuan Ind, Park QIAOLI North Gate
                                      Changping Town, Dongguan, China
    Manufacturer:                     ShenZhen FLYSKY Technology Co.,Ltd

    Address of                        16F, Huafeng Building, No. 6006 Shennan Road, Futian
    Manufacturer:                     District, Shenzhen, Guangdong, China
    Factory:                          FLYSKY RC MODEL TECHNOLOGY CO., LTD

    Address of Factory:               West building3, Huangjianyuan Ind, Park QIAOLI North Gate
                                      Changping Town, Dongguan, China
    Equipment Under Test (EUT)
      Product Name:                   Noble(NB4)

      Model No.:                      FG4, NB4

      Trade Mark:                     FLYSKY

    FCC ID:                           N4ZFG400

    Applicable standards:             FCC CFR Title 47 Part 15 Subpart C Section 15.247

    Date of sample receipt:           March 04, 2019

    Date of Test:                     March 05-13, 2019

    Date of report issued:            March 14, 2019

    Test Result :                     PASS *

*     In the configuration tested, the EUT complied with the standards specified above.




    Authorized Signature:




        Robinson Lo
      Laboratory Manager
This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in
full, without prior written permission of the company. The report would be invalid without specific stamp of test institute
and the signatures of compiler and approver.


                                                                               Report No.: GTS201903000020F01


2     Version
       Report No.             Version No.                 Date                      Description
GTS201804000259F01                  00           September 11, 2018                   Original
GTS201903000020F01                  01              March 14, 2019                 Change PCB




                                                                                     March 14, 2019
Prepared By:                                                       Date:

                                     Project Engineer


                                                                                     March 14, 2019
Check By:                                                          Date:

                                         Reviewer



Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                            Page 2 of 30


                                                                                                                 Report No.: GTS201903000020F01


3         Contents
                                                                                                                                                              Page
1     COVER PAGE ................................................................................................................................................ 1

2     VERSION ........................................................................................................................................................ 2

3     CONTENTS .................................................................................................................................................... 3

4     TEST SUMMARY ........................................................................................................................................... 4
    4.1       MEASUREMENT UNCERTAINTY .................................................................................................................. 4
5     GENERAL INFORMATION ............................................................................................................................ 5
    5.1       GENERAL DESCRIPTION OF EUT ............................................................................................................... 5
    5.2       TEST MODE .............................................................................................................................................. 7
    5.3       TEST FACILITY ......................................................................................................................................... 7
    5.4       TEST LOCATION ....................................................................................................................................... 7
    5.5       OTHER INFORMATION REQUESTED BY THE CUSTOMER............................................................................... 7
    5.6       DESCRIPTION OF SUPPORT UNITS ............................................................................................................. 7
    5.7       ADDITIONAL INSTRUCTIONS ....................................................................................................................... 7
6     TEST INSTRUMENTS LIST ........................................................................................................................... 8

7     TEST RESULTS AND MEASUREMENT DATA .......................................................................................... 10
    7.1       ANTENNA REQUIREMENT ......................................................................................................................... 10
    7.2       CONDUCTED EMISSIONS ......................................................................................................................... 11
    7.3       RADIATED EMISSION METHOD ................................................................................................................. 14
8     TEST SETUP PHOTO .................................................................................................................................. 19

9     EUT CONSTRUCTIONAL DETAILS ............................................................................................................ 21




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                                     Page 3 of 30


 GTS
                                                                                  Report No.: GTS201903000020F01

4       Test Summary
                 Test Item                                   Section                           Result
           Antenna Requirement                          15.203/15.247 (c)                       Pass

    AC Power Line Conducted Emission                          15.207                            Pass
       Conducted Peak Output Power                         15.247 (b)(1)                        N/A
         200B Occupied Bandwidth                           15.247 (a)(1)                        N/A
       Carrier Frequencies Separation                      15.247 (a)(1)                        N/A

         Hopping Channel Number                            15.247 (a)(1)                        N/A

                 Dwell Time                                15.247 (a)(1)                        N/A
    Pseudorandom Frequency Hopping                         15.247(b)(4)                         N/A
              Sequence

             Radiated Emission                            15.205/15.209                         Pass
                 Band Edge                                  15.247(d)                           N/A
Pass: The EUT complies with the essential requirements in the standard.
Remark : Test according to ANSI C63.10.:2013.


4.1      Measurement Uncertainty
             Test Item                        Frequency Range              Measurement Uncertainty       Notes

         Radiated Emission                     OkHz ~ 30MHz                       +4.34dB                 (1)
         Radiated Emission                    30MHz ~ 1000MHz                     +4.240B                 (1)
         Radiated Emission                    1GHz ~26.5GHz                       + 4.68dB                (1)

      AC PowerEmission
                LineConducted                 0. 15MHz ~ 30MHz                    +3.450B                 )
      Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%.




Global United Technology Services Co., Ltd.
No. 301—309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Bacan District, Shenzhen, Gu angdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 4 of 30


                                                                               Report No.: GTS201903000020F01

5     General Information
5.1 General Description of EUT
      Product Name:                      Noble(NB4)
      Model No.:                         FG4, NB4
      Test Model No:                     FG4
      Remark: All above models are identical in the same PCB layout, interior structure and electrical circuits.
      The differences are color and model name for commercial purpose.
      Serial No.:                        N/A
      Hardware Version:                  FG4-V1.4
      Software Version:                  Flysky Noble V1.0.3.6
      Test sample(s) ID:                 GTS201903000020-1
      Sample(s) Status                   Engineer sample
      Operation Frequency:               2402MHz~2480MHz
      Channel numbers:                   63
      Modulation technology:             CSS, GMSK
      Antenna Type:                      Integral Antenna
      Antenna gain:                      2dBi
      Power supply:                      DC 3.7-4.2V 2600mAh Rechargeable Battery
                                         Or DC 5V 1A 4300mAh by external Battery

Remark: The system works in the frequency range of 2402MHz to 2480MHz. This band has been divided to 63
independent channels. Each radio system uses 32 different channels; the minimum channel separation is
≥1.25MHz. By using various switch-on times, hopping scheme and channel frequencies, the system can
guarantee a jamming free radio transmission. The channel list is below.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 5 of 30


                                                                                   Report No.: GTS201903000020F01

Operation Frequency each of channel
             Frequency                        Frequency                        Frequency                  Frequency
 Channel                  Channel                              Channel                     Channel
               (MHz)                            (MHz)                            (MHz)                      (MHz)
    1        2402.4063       17               2421.9087           33           2441.4111      49          2462.0709
     2         2403.6252           18         2423.1276           34            2442.63       50          2463.2898
     3         2404.8441           19         2424.3465           35           2445.0063      51          2464.5087
     4          2406.063           20         2425.5654           36           2446.2252      52          2465.7276
     5         2407.2819           21         2426.7843           37           2447.4441      53          2466.9465
     6         2408.5008           22         2428.0032           38           2448.663       54          2468.1654
     7         2409.7197           23         2429.2221           39           2449.8819      55          2469.3843
     8         2410.9386           24          2430.441           40           2451.1008      56          2470.6032
     9         2412.1575           25         2431.6599           41           2452.3197      57          2471.8221
     10        2413.3764           26         2432.8788           42           2453.5386      58          2473.041
     11        2414.5953           27         2434.0977           43           2454.7575      59          2474.2599
     12        2415.8142           28         2435.3166           44           2455.9764      60          2475.4788
     13        2417.0331           29         2436.5355           45           2457.1953      61          2476.6977
     14         2418.252           30         2437.7544           46           2458.4142      62          2477.9166
     15        2419.4709           31         2438.9733           47           2459.6331      63          2479.1355
     16        2420.6898           32         2440.1922           48           2460.852       64


In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle
frequency, and the highest frequency of channel were selected to perform the test, and the selected channel see
below:


           Channel                       Frequency

     The lowest channel              2402.0/2404.8MHz

     The middle channel              2440.0/2442.6MHz
    The Highest channel              2480.0/2479.1MHz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                Page 6 of 30


                                                                                   Report No.: GTS201903000020F01

5.2 Test mode
      Transmitting mode             Keep the EUT in transmitting mode.

5.3 Test Facility
      The test facility is recognized, certified, or accredited by the following organizations:
      ● FCC —Registration No.: 381383
      Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and fully
      described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
      from the FCC is maintained in files. Registration 381383.
      ● Industry Canada (IC) —Registration No.: 9079A-2
      The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. has been registered by
      Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration
      No.: 9079A-2.
      ● NVLAP (LAB CODE:600179-0)
      Global United Technology Services Co., Ltd., is accredited by the National Voluntary Laboratory
      Accreditation Program (NVLAP). LAB CODE:600179-0
5.4 Test Location
      All other tests were performed at:
      Global United Technology Services Co., Ltd.
      Address: No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road,
      Baoan District, Shenzhen, Guangdong, China 518102
      Tel: 0755-27798480
      Fax: 0755-27798960
5.5 Other Information Requested by the Customer
      None.
5.6 Description of Support Units
        Manufacturer                Description             Model              Serial Number       FCC Approval
           DELTA                     ADAPTER             ADP-60ADT                 N/A                    DELTA
5.7 Additional Instructions
EUT Software Settings:

          Mode                Special test firmware was pre-built-in by manufacturer
          GFSK                           Channel                    Frequency (MHz)                 Level Set
                                         Lowest                       2402/2404.8
                                          Middle                       2440/242.6              TX level : default
                                         Highest                      2480/2479.1




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                Page 7 of 30


                                                                                   Report No.: GTS201903000020F01


6       Test Instruments list
Radiated Emission:
                                                                               Inventory     Cal.Date        Cal.Due date
Item       Test Equipment          Manufacturer             Model No.
                                                                                  No.       (mm-dd-yy)       (mm-dd-yy)
         3m Semi- Anechoic
 1                               ZhongYu Electron     9.2(L)*6.2(W)* 6.4(H)    GTS250      July. 03 2015    July. 02 2020
             Chamber
 2         Control Room          ZhongYu Electron     6.2(L)*2.5(W)* 2.4(H)    GTS251          N/A              N/A
 3       EMI Test Receiver       Rohde & Schwarz             ESU26             GTS203      June. 27 2018    June. 26 2019
                                 SCHWARZBECK
 4       BiConiLog Antenna                                 VULB9163            GTS214      June. 27 2018    June. 26 2019
                                MESS-ELEKTRONIK
           Double -ridged        SCHWARZBECK
 5                                                        BBHA 9120 D          GTS208      June. 27 2018    June. 26 2019
           waveguide horn       MESS-ELEKTRONIK

 6         Horn Antenna          ETS-LINDGREN                 3160             GTS217      June. 27 2018    June. 26 2019
 7       EMI Test Software            AUDIX                    E3                N/A           N/A              N/A
 8         Coaxial Cable               GTS                     N/A             GTS213      June. 27 2018    June. 26 2019
 9         Coaxial Cable               GTS                     N/A             GTS211      June. 27 2018    June. 26 2019
10         Coaxial cable               GTS                     N/A             GTS210      June. 27 2018    June. 26 2019
11         Coaxial Cable               GTS                     N/A             GTS212      June. 27 2018    June. 26 2019
12     Amplifier(100kHz-3GHz)           HP                   8347A             GTS204      June. 27 2018    June. 26 2019
13     Amplifier(2GHz-20GHz)            HP                   84722A            GTS206      June. 27 2018    June. 26 2019
                                                          AFS33-18002
14      Amplifier (18-26GHz)     Rohde & Schwarz                               GTS218      June. 27 2018    June. 26 2019
                                                          650-30-8P-44
15           Band filter            Amindeon                 82346             GTS219      June. 27 2018    June. 26 2019
16          Power Meter               Anritsu               ML2495A            GTS540      June. 27 2018    June. 26 2019
17         Power Sensor               Anritsu               MA2411B            GTS541      June. 27 2018    June. 26 2019
         Wideband Radio
18                               Rohde & Schwarz            CMW500             GTS575      June. 27 2018    June. 26 2019
       Communication Tester
19            Splitter                Agilent                11636B            GTS237      June. 27 2018    June. 26 2019
20         Loop Antenna              ZHINAN                ZN30900A            GTS534      June. 27 2018    June. 26 2019
             Breitband
21                               SCHWARZBECK               BBHA 9170           GTS579      Oct. 20 2018     Oct. 19 2019
            hornantenne
22            Amplifier                TDK                  PA-02-02           GTS574      Oct. 20 2018     Oct. 19 2019
23            Amplifier                TDK                  PA-02-03           GTS576      Oct. 20 2018     Oct. 19 2019
        PSA Series Spectrum
24                               Rohde & Schwarz              FSP              GTS578      June. 27 2018    June. 26 2019
             Analyzer




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                  Page 8 of 30


                                                                                    Report No.: GTS201903000020F01

Conducted Emission
                                                                                Inventory    Cal.Date         Cal.Due date
 Item         Test Equipment        Manufacturer            Model No.
                                                                                   No.      (mm-dd-yy)         (mm-dd-yy)
     1        Shielding Room      ZhongYu Electron    7.3(L)x3.1(W)x2.9(H)      GTS252     May.16 2014        May.15 2019
     2       EMI Test Receiver          R&S                  ESCI 7             GTS552    June. 27 2018      June. 26 2019
     3        Coaxial Switch      ANRITSU CORP               MP59B              GTS225    June. 27 2018      June. 26 2019
              Artificial Mains    SCHWARZBECK
     4                                                     NSLK8127              GTS226     June. 27 2018    June. 26 2019
                  Network              MESS
     5         Coaxial Cable            GTS                   N/A                GTS227          N/A              N/A
     6       EMI Test Software         AUDIX                  E3                  N/A            N/A              N/A
     7         Thermo meter             KTJ                  TA328               GTS233     June. 27 2018    June. 26 2019
                                     Elektronik-
     8       Absorbing clamp                                 MDS21               GTS229     June. 27 2018    June. 26 2019
                                   Feinmechanik


RF Conducted Test:

                                                                                               Cal.Date       Cal.Due date
Item          Test Equipment         Manufacturer         Model No.            Serial No.
                                                                                              (mm-dd-yy)      (mm-dd-yy)

 1          MXA Signal Analyzer         Agilent            N9020A              GTS566       June. 27 2018    June. 26 2019

 2           EMI Test Receiver           R&S               ESCI 7              GTS552       June. 27 2018    June. 26 2019

 3           Spectrum Analyzer          Agilent            E4440A              GTS533       June. 27 2018    June. 26 2019

             MXG vector Signal
 4                                      Agilent            N5182A              GTS567       June. 27 2018    June. 26 2019
                 Generator
            ESG Analog Signal
 5                                      Agilent            E4428C              GTS568       June. 27 2018    June. 26 2019
                 Generator

 6         USB RF Power Sensor          DARE             RPR3006W              GTS569       June. 27 2018    June. 26 2019


 7             RF Switch Box           Shongyi         RFSW3003328             GTS571       June. 27 2018    June. 26 2019


 8           EMI Test Receiver           R&S               ESCI 7              GTS552       June. 27 2018    June. 26 2019

          Programmable Constant
 9             Temp & Humi             WEWON         WHTH-150L-40-880          GTS572       June. 27 2018    June. 26 2019
               Test Chamber


General used equipment:

                                                                                Inventory     Cal.Date        Cal.Due date
Item        Test Equipment         Manufacturer            Model No.
                                                                                   No.       (mm-dd-yy)       (mm-dd-yy)

         Humidity/ Temperature
 1                                     KTJ                  TA328               GTS243      June. 27 2018    June. 26 2019
               Indicator
 2            Barometer            ChangChun                 DYM3               GTS255      June. 27 2018    June. 26 2019




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                   Page 9 of 30


                                                                               Report No.: GTS201903000020F01


7      Test results and Measurement Data
7.1 Antenna requirement
      Standard requirement:           FCC Part15 C Section 15.203 /247(c)
       15.203 requirement:
       An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
       responsible party shall be used with the device. The use of a permanently attached antenna or of an
       antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so
       that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical
       connector is prohibited.
       15.247(c) (1)(i) requirement:
       (i) Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed. Point-to-point
       operations may employ transmitting antennas with directional gain greater than 6dBi provided the
       maximum conducted output power of the intentional radiator is reduced by 1 dB for every 3 dB that the
       directional gain of the antenna exceeds 6dBi.
      EUT Antenna:
      The antenna is integral Antenna, the best case gain of the antenna is 2dBi




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 10 of 30


                                                                               Report No.: GTS201903000020F01


7.2 Conducted Emissions
      Test Requirement:               FCC Part15 C Section 15.207
      Test Method:                    ANSI C63.10:2013
      Test Frequency Range:           150KHz to 30MHz
      Class / Severity:               Class B         Class B
      Receiver setup:                 RBW=9KHz, VBW=30KHz, Sweep time=auto
      Limit:                                                                        Limit (dBuV)
                                          Frequency range (MHz)
                                                                         Quasi-peak              Average
                                                0.15-0.5                   66 to 56*             56 to 46*
                                                 0.5-5                         56                   46
                                                  5-30                         60                   50
                                      * Decreases with the logarithm of the frequency.
      Test setup:




      Test procedure:                 1. The E.U.T and simulators are connected to the main power through a
                                         line impedance stabilization network (L.I.S.N.). This provides a
                                         50ohm/50uH coupling impedance for the measuring equipment.
                                      2. The peripheral devices are also connected to the main power through a
                                         LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                         termination. (Please refer to the block diagram of the test setup and
                                         photographs).
                                      3. Both sides of A.C. line are checked for maximum conducted
                                         interference. In order to find the maximum emission, the relative
                                         positions of equipment and all of the interface cables must be changed
                                         according to ANSI C63.10:2013 on conducted measurement.
      Test environment:               Temp.:        25 C         Humid.:      52%        Press.:
                                                                                                       1 012mbar
      Test Instruments:               Refer to section 6.0 for details
      Test mode:                      Refer to section 5.2 for details
      Test results:                   Pass




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                            Page 11 of 30


                                                                               Report No.: GTS201903000020F01


Measurement data:


Test mode:                   Transmitting mode             Phase Polarity:           Line




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 12 of 30


                                                                               Report No.: GTS201903000020F01


Test mode:                   Transmitting mode             Phase Polarity:           Neutral




Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 13 of 30


                                                                                   Report No.: GTS201903000020F01


7.3 Radiated Emission Method
      Test Requirement:               FCC Part15 C Section 15.209
      Test Method:                    ANSI C63.10:2013
      Test Frequency Range:           9kHz to 25GHz
      Test site:                      Measurement Distance: 3m
      Receiver setup:                       Frequency           Detector        RBW         VBW             Value
                                          9KHz-150KHz          Quasi-peak       200Hz       600Hz      Quasi-peak
                                         150KHz-30MHz          Quasi-peak       9KHz        30KHz      Quasi-peak
                                          30MHz-1GHz           Quasi-peak       100KHz     300KHz      Quasi-peak
                                                                  Peak          1MHz        3MHz            Peak
                                          Above 1GHz
                                                                  Peak          1MHz        10Hz           Average
      Limit:                                                                                        Measurement
                                              Frequency             Limit (uV/m)         Value
      (Spurious Emissions)                                                                            Distance
                                        0.009MHz-0.490MHz           2400/F(KHz)           QP               300m
                                        0.490MHz-1.705MHz          24000/F(KHz)           QP               300m
                                          1.705MHz-30MHz                   30             QP               30m
                                            30MHz-88MHz                  100              QP
                                           88MHz-216MHz                  150              QP
                                          216MHz-960MHz                  200              QP
                                                                                                           3m
                                            960MHz-1GHz                  500              QP
                                                                         500           Average
                                             Above 1GHz
                                                                         5000            Peak
      Test setup:                     Below 30MHz




                                      Below 1GHz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                Page 14 of 30


                                                                               Report No.: GTS201903000020F01




                                      Above 1GHz




      Test Procedure:                 1.   The EUT was placed on the top of a rotating table (0.8 meters for
                                           below 1GHz and 1.5meters for above 1GHz) above the ground at a 3
                                           meter camber. The table was rotated 360 degrees to determine the
                                           position of the highest radiation.
                                      2. The EUT was set 3 meters away from the interference-receiving
                                         antenna, which was mounted on the top of a variable-height antenna
                                         tower.
                                      3. The antenna height is varied from one meter to four meters above the
                                         ground to determine the maximum value of the field strength. Both
                                         horizontal and vertical polarizations of the antenna are set to make the
                                         measurement.
                                      4. For each suspected emission, the EUT was arranged to its worst case
                                         and then the antenna was tuned to heights from 1 meter to 4 meters
                                         and the rota table was turned from 0 degrees to 360 degrees to find the
                                         maximum reading.
                                      5. The test-receiver system was set to Peak Detect Function and Specified
                                         Bandwidth with Maximum Hold Mode.
                                      6. If the emission level of the EUT in peak mode was 10dB lower than the
                                         limit specified, then testing could be stopped and the peak values of the
                                         EUT would be reported. Otherwise the emissions that did not have 10dB
                                         margin would be re-tested one by one using peak, quasi-peak or

Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 15 of 30


                                                                             Report No.: GTS201903000020F01
                                         average method as specified and then reported in a data sheet.
      Test Instruments:               Refer to section 5.8 for details
      Test mode:                      Refer to section 5.2 for details
      Temp. / Hum.                    Temp.:         25 C        Humid.:      52%       Press.:    1 012mbar
      Test results:                   Pass


Remark:
1. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and found the Y-axis which it is worse case.




Measurement data:
   Below 30MHz

The low frequency, which started from 9 kHz to 30 MHz, was pre-scanned and the result which was 20 dB lower
than the limit line per 15.31(o) was not reported.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                            Page 16 of 30


                                                                               Report No.: GTS201903000020F01


    30MHz ~ 1GHz

Horizontal:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 17 of 30


                                                                               Report No.: GTS201903000020F01

Vertical:




Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 18 of 30


                                                                               Report No.: GTS201903000020F01


8     Test Setup Photo
       Radiated Emission




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 19 of 30


                                                                               Report No.: GTS201903000020F01




       Conducted Emission




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 20 of 30


                                                                               Report No.: GTS201903000020F01


9     EUT Constructional Details




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 21 of 30


                                                                               Report No.: GTS201903000020F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 22 of 30


                                                                               Report No.: GTS201903000020F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 23 of 30


                                                                               Report No.: GTS201903000020F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 24 of 30


                                                                               Report No.: GTS201903000020F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 25 of 30


                                                                               Report No.: GTS201903000020F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 26 of 30


                                                                               Report No.: GTS201903000020F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 27 of 30


                                                                               Report No.: GTS201903000020F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 28 of 30


                                                                               Report No.: GTS201903000020F01




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 29 of 30


                                                                               Report No.: GTS201903000020F01




                                                        ---End---




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 30 of 30



Document Created: 2019-03-31 19:49:32
Document Modified: 2019-03-31 19:49:32

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC