Test Report

FCC ID: N4ZFBSDGT2

Test Report

Download: PDF
FCCID_2692769

                               Global United Technology Services Co., Ltd.

                                                                                       Report No.: GTSE15060103701
1        Cover Page
                                        FCC Report
    Applicant:                         FLYSKY RC MODEL TECHNOLOGY CO., LTD

    Address of Applicant:  West building3, Huangjianyuan Ind, Park QIAOLI North Gate
                           Changping Town Dongguan CN.
    Equipment Under Test (EUT)
      Product Name:                    2CH Gun Radio

      Model No.:                       BSD-GT2

    FCC ID:                            N4ZFBSDGT2

    Applicable standards:              FCC CFR Title 47 Part 15 Subpart C Section 15.247:2014

    Date of sample receipt:            June 05, 2015

    Date of Test:                      June 05-16, 2015

    Date of report issued:             June 16, 2015

    Test Result :                      PASS *

*     In the configuration tested, the EUT complied with the standards specified above.




    Authorized Signature:




            Robinson Lo
            Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not
relate to other samples of the same product and does not permit the use of the GTS product certification mark. The
manufacturer should ensure that all products in series production are in conformity with the product sample detailed in
this report.
This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other
than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any
mention of GTS International Electrical Approvals or testing done by GTS International Electrical Approvals in connection
with, distribution or use of the product described in this report must be approved by GTS International Electrical
Approvals in writing.
This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 90 days only.”


                                                                                   Report No.: GTSE15060103701


2      Version

    Version No.                        Date                                    Description
          00                      June 16, 2015                                  Original




Prepared By:                                                       Date:                June 16, 2015

                                     Project Engineer


Check By:                                                          Date:                June 16, 2015

                                          Reviewer




Global United Technology Services Co., Ltd.                                      Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 2 of 26


                                                                                                                       Report No.: GTSE15060103701


3         Contents
                                                                                                                                                              Page
1      COVER PAGE ................................................................................................................................................1

2      VERSION ........................................................................................................................................................2

3      CONTENTS ....................................................................................................................................................3

4      TEST SUMMARY ...........................................................................................................................................4

5      GENERAL INFORMATION............................................................................................................................5
    5.1        CLIENT INFORMATION ...............................................................................................................................5
    5.2        GENERAL DESCRIPTION OF EUT ...............................................................................................................5
    5.3        TEST MODE ..............................................................................................................................................7
    5.4        TEST FACILITY..........................................................................................................................................7
    5.5        TEST LOCATION .......................................................................................................................................7
    5.6        OTHER INFORMATION REQUESTED BY THE CUSTOMER ...............................................................................7
    5.7        DESCRIPTION OF SUPPORT UNITS .............................................................................................................7
    5.8        TEST INSTRUMENTS LIST ...........................................................................................................................8
6      TEST RESULTS AND MEASUREMENT DATA............................................................................................9
    6.1     ANTENNA REQUIREMENT:..........................................................................................................................9
    6.2     SPURIOUS EMISSION...............................................................................................................................10
       6.2.1 Radiated Emission Method..............................................................................................................10
7      TEST SETUP PHOTO ..................................................................................................................................17

8      EUT CONSTRUCTIONAL DETAILS ...........................................................................................................19




Global United Technology Services Co., Ltd.                                                                         Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                                     Page 3 of 26


                                                                                     Report No.: GTSE15060103701

4      Test Summary
                 Test Item                                   Section                           Result
          Antenna Requirement                           15.203/15.247 (c)                       Pass
    AC Power Line Conducted Emission                          15.207                            N/A
      Conducted Peak Output Power                          15.247 (b)(1)                        Pass
        20dB Occupied Bandwidth                            15.247 (a)(1)                        Pass
      Carrier Frequencies Separation                       15.247 (a)(1)                        Pass
        Hopping Channel Number                             15.247 (a)(1)                        Pass
                Dwell Time                                 15.247 (a)(1)                        Pass
    Pseudorandom Frequency Hopping
                                                           15.247(a)(1)                         Pass
              Sequence
            Radiated Emission                             15.205/15.209                         Pass
                Band Edge                                    15.247(d)                          Pass
Pass: The EUT complies with the essential requirements in the standard.


    4.1 Measurement Uncertainty
            Test Item                      Frequency Range                 Measurement Uncertainty       Notes
        Radiated Emission                     9kHz ~ 30MHz                         4.34dB                (1)
        Radiated Emission                  30MHz ~ 1000MHz                         4.24dB                (1)
        Radiated Emission                   1GHz ~ 26.5GHz                         4.68dB                (1)
    AC Power Line Conducted
                                           0.15MHz ~ 30MHz                         3.45dB                (1)
          Emission
Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%.


Remark: Test according to ANSI C63.4:2009 and ANSI C63.10:2009




Global United Technology Services Co., Ltd.                                        Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 4 of 26


                                                                                 Report No.: GTSE15060103701
5      General Information
5.1 Client Information
      Applicant:                         FLYSKY RC MODEL TECHNOLOGY CO., LTD
      Address of Applicant:              West building3, Huangjianyuan Ind, Park QIAOLI North Gate Changping
                                         Town Dongguan CN.
      Manufacturer:                      FLYSKY RC MODEL TECHNOLOGY CO., LTD
      Address of Manufacturer:           West building3, Huangjianyuan Ind, Park QIAOLI North Gate Changping
                                         Town Dongguan CN.
      Factory:                           FLYSKY RC MODEL TECHNOLOGY CO., LTD
      Address of Factory:                West building3, Huangjianyuan Ind, Park QIAOLI North Gate Changping
                                         Town Dongguan CN.
5.2 General Description of EUT
      Product Name:                      2CH Gun Radio
      Model No.:                         BSD-GT2
      Operation Frequency:               2404MHz~2476.5MHz
      Channel numbers:                   16
      Modulation type:                   GFSK
      Antenna Type:                      Integral
      Antenna gain:                      2dBi
      Power supply:                      DC 6.0V (4*1.5V “AA“ Size Battery)




Global United Technology Services Co., Ltd.                                    Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 5 of 26


                                                                                         Report No.: GTSE15060103701

Operation Frequency each of channel
               Frequency                      Frequency                        Frequency                     Frequency
 Channel                        Channel                        Channel                       Channel
                 (MHz)                          (MHz)                            (MHz)                         (MHz)
    1            2404.0             5           2420.5             9            2440.0          13            2460.5
    2            2405.5             6           2425.5            10            2445.5          14            2465.5
    3            2410.5             7           2430.5            11            2450.5          15            2470.5
    4            2415.5             8           2435.5            12            2455.5          16            2476.5


In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle
frequency, and the highest frequency of channel were selected to perform the test, and the selected channel
see below:


           Channel                        Frequency

     The lowest channel                  2404.0MHz

     The middle channel                  2440.0MHz
    The Highest channel                  2476.5MHz




Global United Technology Services Co., Ltd.                                         Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                   Page 6 of 26


                                                                                 Report No.: GTSE15060103701

5.3 Test mode
      Transmitting mode             Keep the EUT in transmitting mode.
      Remark: During the test, the new battery was used.
5.4 Test Facility
      The test facility is recognized, certified, or accredited by the following organizations:
      ● CNAS —Registration No.: CNAS L5775
      CNAS has accredited Global United Technology Services Co., Ltd. To ISO/IEC 17025 General
      Requirements for the competence of testing and calibration laboratories (CNAS-CL01 Accreditation
      Criteria for the Competence of Testing and Calibration Laboratories) for the competence in the field of
      testing.
      ● FCC —Registration No.: 600491
      Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and fuly
      described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
      from the FCC is maintained in files. Registration 600491, June 28, 2013.
      ● Industry Canada (IC) —Registration No.: 9079A-2
      The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. has been registered by
      Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration
      No.: 9079A-2, June 26, 2013.
5.5 Test Location
       All other tests were performed at:
       Global United Technology Services Co., Ltd.
       Address: Room 301-309, 3th Floor, Block A, Huafeng Jinyuan Business Building, No. 300 Laodong
       Industrial Zone,Xixiang Road, Baoan District, Shenzhen 518102
       Tel: 0755-27798480
       Fax: 0755-27798960
5.6 Other Information Requested by the Customer
      None.
5.7 Description of Support Units
      None.




Global United Technology Services Co., Ltd.                                    Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 7 of 26


                                                                                           Report No.: GTSE15060103701


5.8 Test Instruments list
Radiated Emission:

                                                                               Inventory       Cal.Date     Cal.Due date
Item       Test Equipment           Manufacturer           Model No.
                                                                                 No.         (mm-dd-yy)        (mm-dd-yy)

          3m Semi- Anechoic
 1                                 ZhongYu Electron   9.2(L)*6.2(W)* 6.4(H)    GTS250        Mar. 27 2015   Mar. 26 2016
              Chamber

 2          Control Room           ZhongYu Electron   6.2(L)*2.5(W)* 2.4(H)    GTS251            N/A               N/A

 3        Spectrum Analyzer            Agilent              E4440A             GTS533         Dec. 4 2014      Dec. 3 2015

 4        EMI Test Receiver        Rohde & Schwarz          ESU26              GTS203        July 01 2014   June 30 2015

                                   SCHWARZBECK
 5        BiConiLog Antenna                                VULB9163            GTS214        July 01 2014   June 30 2015
                                  MESS-ELEKTRONIK

       Double -ridged waveguide    SCHWARZBECK
 6                                                         9120D-829           GTS208        June 27 2014   June 26 2015
                 horn             MESS-ELEKTRONIK

 7          Horn Antenna           ETS-LINDGREN               3160             GTS217        Mar. 27 2015   Mar. 26 2016

 8        EMI Test Software            AUDIX                   E3                N/A             N/A               N/A

 9          Coaxial Cable               GTS                   N/A              GTS213        Mar. 27 2015   Mar. 26 2016

10          Coaxial Cable               GTS                   N/A              GTS211        Mar. 28 2015   Mar. 27 2016

11          Coaxial cable               GTS                   N/A              GTS210        Mar. 28 2015   Mar. 27 2016

12          Coaxial Cable               GTS                   N/A              GTS212        Mar. 28 2015   Mar. 27 2016

13     Amplifier(100kHz-3GHz)            HP                  8347A             GTS204        July 01 2014   June 30 2015

14      Amplifier(2GHz-20GHz)            HP                  8349B             GTS206        July 01 2014   June 30 2015

                                                         AFS33-18002
15       Amplifier (18-26GHz)      Rohde & Schwarz                             GTS218        June 27 2014   June 26 2015
                                                         650-30-8P-44

16            Band filter             Amindeon               82346             GTS219        Mar. 28 2015   Mar. 27 2016




General used equipment:

                                                                               Inventory       Cal.Date     Cal.Due date
Item       Test Equipment           Manufacturer           Model No.
                                                                                 No.         (mm-dd-yy)        (mm-dd-yy)

 1            Barometer              ChangChun               DYM3              GTS257        July 08 2014      July 07 2015




Global United Technology Services Co., Ltd.                                            Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                     Page 8 of 26


                                                                                 Report No.: GTSE15060103701


6      Test results and Measurement Data
6.1 Antenna requirement:
      Standard requirement:            FCC Part15 C Section 15.203 /247(c)
       15.203 requirement:
       An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
       responsible party shall be used with the device. The use of a permanently attached antenna or of an
       antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so
       that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical
       connector is prohibited.
       15.247(c) (1)(i) requirement:
       (i) Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed. Point-to-point
       operations may employ transmitting antennas with directional gain greater than 6dBi provided the
       maximum conducted output power of the intentional radiator is reduced by 1 dB for every 3 dB that the
       directional gain of the antenna exceeds 6dBi.
      E.U.T Antenna:
      The antenna is Integral Antenna, the best case gain of the antenna is 2dBi


                                                         Antenna




Global United Technology Services Co., Ltd.                                    Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                           Page 9 of 26


                                                                                      Report No.: GTSE15060103701

6.2 Spurious Emission
6.2.1     Radiated Emission Method
        Test Requirement:              FCC Part15 C Section 15.209
        Test Method:                   ANSI C63.10: 2009
        Test Frequency Range:          9kHz to 25GHz
        Test site:                     Measurement Distance: 3m
        Receiver setup:                     Frequency            Detector         RBW        VBW             Value
                                          9KHz-150KHz          Quasi-peak        200Hz       600Hz      Quasi-peak
                                         150KHz-30MHz          Quasi-peak        9KHz        30KHz      Quasi-peak
                                          30MHz-1GHz           Quasi-peak        100KHz     300KHz      Quasi-peak
                                                                   Peak          1MHz        3MHz            Peak
                                           Above 1GHz
                                                                   Peak          1MHz        10Hz           Average
        Limit:                                                                                       Measurement
                                               Frequency             Limit (uV/m)         Value
        (Spurious Emissions)                                                                          Distance
                                         0.009MHz-0.490MHz           2400/F(KHz)           QP               300m
                                         0.490MHz-1.705MHz          24000/F(KHz)           QP               300m
                                          1.705MHz-30MHz                    30             QP               30m
                                            30MHz-88MHz                   100              QP
                                           88MHz-216MHz                   150              QP
                                           216MHz-960MHz                  200              QP
                                                                                                            3m
                                            960MHz-1GHz                   500              QP
                                                                          500           Average
                                             Above 1GHz
                                                                          5000            Peak
        Test setup:                    Below 1GHz




                                       Above 1GHz




Global United Technology Services Co., Ltd.                                         Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 10 of 26


                                                                                       Report No.: GTSE15060103701




      Test Procedure:                  1. The EUT was placed on the top of a rotating table 0.8 meters above the ground
                                          at a 3 meter camber. The table was rotated 360 degrees to determine the
                                          position of the highest radiation.
                                       2. The EUT was set 3 meters away from the interference-receiving antenna, which
                                          was mounted on the top of a variable-height antenna tower.
                                       3. The antenna height is varied from one meter to four meters above the ground to
                                          determine the maximum value of the field strength. Both horizontal and vertical
                                          polarizations of the antenna are set to make the measurement.
                                       4. For each suspected emission, the EUT was arranged to its worst case and then
                                          the antenna was tuned to heights from 1 meter to 4 meters and the rota table
                                          was turned from 0 degrees to 360 degrees to find the maximum reading.
                                       5. The test-receiver system was set to Peak Detect Function and Specified
                                          Bandwidth with Maximum Hold Mode.
                                       6. If the emission level of the EUT in peak mode was 10dB lower than the limit
                                          specified, then testing could be stopped and the peak values of the EUT would
                                          be reported. Otherwise the emissions that did not have 10dB margin would be
                                          re-tested one by one using peak, quasi-peak or average method as specified
                                          and then reported in a data sheet.
      Test Instruments:                Refer to section 5.8 for details
      Test mode:                       Refer to section 5.3 for details
      Test results:                    Pass


Remark:
1. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and found the Y-axis which it is worse case.




Global United Technology Services Co., Ltd.                                          Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                  Page 11 of 26


                                                                                    Report No.: GTSE15060103701

Measurement data:
   9KHz ~ 30MHz
                 Read      Antenna       Cable       Preamp                                     Over
Frequency                                                           Level      Limit Line
                 Level      Factor       Loss         Factor                                    Limit
  (MHz)                                                           (dBuV/m)     (dBuV/m)
                (dBuV)      (dB/m)        (dB)         (dB)                                     (dB)
   0.014        11.53        20.63        0.03         9.71         22.48       124.92        -102.44
   0.051        11.92        21.73        0.12         9.91         23.86       113.37         -89.51
   0.184         8.96        22.40        0.21        10.40         21.17       102.31         -81.14
   0.902        11.87        20.99        0.32        10.29         22.89       68.50          -45.61
   3.496        11.50        21.56        0.41        10.34         23.13       69.54          -46.41
   9.636         9.70        23.45        0.48        10.47         23.16       69.54          -46.38




Global United Technology Services Co., Ltd.                                       Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 12 of 26


GLISs
                      Level (dBuVim}
                130
                120 \
                100                                \\\

                80                                                          L
                                                                                 H______H_           ECC PART15 BEL OW 30M

                60


                40


                20                                          ’


                  0.009         .92         .05    AJ           2           .5        1      2        5      10      20   30
                                                                    Frequency (MHz)
Site                        : Im chamber
Condition                   : FCC PARTIS BELOY 30M 3m LOOP ANTENNA
Job NO.                     : 1037RF
Test Mode     : Operation mode
Test Engineer: Rong
                  ReadAntenna Cable Preamp                                   Limit     Over
          Freq Level Factor     Loss Factor                         Level     Line    Limit Remark

                CThz dbuvy db/m _dB _dB dBu¥/m dBu¥/m —
                       0.014     11.53    20.63   0.03   9.71       22.48 124.92—102.44 Average
 oo one oo no




                       0.051     11.92    21.73   0.12   9.91       23.86 113.37 —89.51 Average
                       0. 184     8.96    22.40   0.21   10.40      21.17 102.31 —81.14 Average
                       0.902     11.87    20.99   0.32   10.29      22.89 68.50 —45.61 QP
                       3.496     11.50    21.56   O.41   10.34      23.13    69.54 —46.41 QP
                       9.636       9.70   23.45   0.48   10.47      23.16    69.54 —46.38 QP
                                                                                                               w


                                                                                    Report No.: GTSE15060103701


     30MHz ~ 1GHz
                 Read      Antenna       Cable       Preamp                                     Over
Frequency                                                           Level      Limit Line
                 Level      Factor       Loss         Factor                                    Limit       Polarization
  (MHz)                                                           (dBuV/m)     (dBuV/m)
                (dBuV)      (dB/m)        (dB)         (dB)                                     (dB)
    56.00       28.31        14.95        0.83        29.95         14.14       40.00          -25.86         Vertical
    143.83      38.79        10.22        1.53        29.44         21.10       43.50          -22.40         Vertical
    159.78      40.95        10.64        1.63        29.36         23.86       43.50          -19.64         Vertical
    176.27      37.57        11.42        1.72        29.29         21.42       43.50          -22.08         Vertical
    365.54      25.59        16.48        2.69        29.66         15.10       46.00          -30.90         Vertical
    605.66      25.75        20.47        3.74        29.30         20.66       46.00          -25.34         Vertical
    47.16       29.23        15.42        0.74        30.01         15.38       40.00          -24.62       Horizontal
    88.03       30.33        13.32        1.09        29.76         14.98       43.50          -28.52       Horizontal
    159.78      38.72        10.64        1.63        29.36         21.63       43.50          -21.87       Horizontal
    216.02      28.10        13.07        1.93        29.36         13.74       46.00          -32.26       Horizontal
    434.07      31.00        17.53        3.02        29.43         22.12       46.00          -23.88       Horizontal
    576.64      28.36        20.03        3.63        29.30         22.72       46.00          -23.28       Horizontal




Global United Technology Services Co., Ltd.                                       Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 14 of 26


                                                                                 Report No.: GTSE15060103701

Vertical:




Global United Technology Services Co., Ltd.                                    Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                          Page 15 of 26


                                                                                 Report No.: GTSE15060103701


Horizontal:




Global United Technology Services Co., Ltd.                                    Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                          Page 16 of 26


                                                                                 Report No.: GTSE15060103701


7      Test Setup Photo
       Radiated Emission




Global United Technology Services Co., Ltd.                                    Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                          Page 17 of 26


                                                                                 Report No.: GTSE15060103701




Global United Technology Services Co., Ltd.                                    Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                          Page 18 of 26


                                                                                 Report No.: GTSE15060103701


8      EUT Constructional Details




Global United Technology Services Co., Ltd.                                    Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                          Page 19 of 26


                                                                                 Report No.: GTSE15060103701




Global United Technology Services Co., Ltd.                                    Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                          Page 20 of 26


                                                                                 Report No.: GTSE15060103701




Global United Technology Services Co., Ltd.                                    Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                          Page 21 of 26


                                                                                 Report No.: GTSE15060103701




Global United Technology Services Co., Ltd.                                    Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                          Page 22 of 26


                                                                                 Report No.: GTSE15060103701




Global United Technology Services Co., Ltd.                                    Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                          Page 23 of 26


                                                                                 Report No.: GTSE15060103701




Global United Technology Services Co., Ltd.                                    Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                          Page 24 of 26


                                                                                 Report No.: GTSE15060103701




Global United Technology Services Co., Ltd.                                    Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                          Page 25 of 26


                                                                                 Report No.: GTSE15060103701




                                                      ------end---




Global United Technology Services Co., Ltd.                                    Project No.: GTSE150601037RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                          Page 26 of 26



Document Created: 2019-11-10 02:09:51
Document Modified: 2019-11-10 02:09:51

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC