            FCC ID                 : MXF-WSMS-140
            Equipment              : Telemetry Unit
            Model No.              : WSMS-140_C
                                     (Refer to item 1.1 for more details.)
            Brand Name             : Gemtek/Linde
            Applicant              : Gemtek Technology Co., Ltd.
            Address                : No. 15-1 Zhonghua Road, Hsinchu Industrial
                                     Park, Hukou, Hsinchu, Taiwan, 30352.
            Standard               : 47 CFR FCC Part 2.1091
            Received Date          : Jul. 09, 2018
            Tested Date            : Jul. 25 ~ Aug. 03, 2018


      We, International Certification Corp., would like to declare that the tested sample has been
      evaluated and in compliance with the requirement of the above standards. The test results
      contained in this report refer exclusively to the product. It may be duplicated completely for
      legal use with the approval of the applicant. It shall not be reproduced except in full without
      the written approval of our laboratory.



      Reviewed by:                        Approved by:




      Along Chen / Assistant Manager      Gary Chang / Manager




Report No.: FA870901                                                                  Page : 1 of 6
Report Version: Rev. 01


                                                       Table of Contents
1        INFORMATION ...................................................................................................................................... 4

1.1      PRODUCT DETAILS .............................................................................................................................. 4

2        MPE EVALUATION OF MOBILE DEVICES ......................................................................................... 4

2.1      LIMITS FOR GENERAL POPULATION/UNCONTROLLED EXPOSURE............................................. 5
2.2      MPE EVALUATION FORMULA ............................................................................................................. 5
2.3      MPE EVALUATION RESULTS .............................................................................................................. 5

3        TEST LABORATORY INFORMATION ................................................................................................. 6




Report No.: FA870901                                                                                                          Page : 2 of 6
Report Version: Rev. 01


                                    Release Record
     Report No.           Version                   Description      Issued Date
      FA870901            Rev. 01   Initial issue                   Aug. 21, 2018




Report No.: FA870901                                              Page : 3 of 6
Report Version: Rev. 01


1         INFORMATION
1.1       PRODUCT DETAILS
The following models are provided to this EUT.

        Brand Name               Model Name      Product Name           Description
                                 WSMS-140_C                       4-20mA current sense
                                                                  Modbus RS-485
                                 WSMS-140_B
       Gemtek/Linde                              Telemetry Unit   communication
                                                                  Hall sensor for magnet
                                WSMS-140_G
                                                                  sense




Report No.: FA870901                                                   Page : 4 of 6
Report Version: Rev. 01


2         MPE EVALUATION OF MOBILE DEVICES
Human exposure to RF emissions from mobile devices (47 CFR §2.1091) may be evaluated based on the
MPE limits adopted by the FCC for electric and magnetic field strength and/or power density, as appropriate,
since exposures are assumed to occur at distances of 20 cm or more from persons.



2.1       LIMITS FOR GENERAL POPULATION/UNCONTROLLED EXPOSURE
                                                                   2
      Frequency Range (MHz)                   Power Density (mW /cm )        Averaging Time (minutes)
               300~1500                               F/1500                              30
             1500~100000                                1.0                               30


2.2       MPE EVALUATION FORMULA
                                Pt
                 Pd =
                           4 * Pi * R 2
Where
                                   2
Pd=   Power density in mW/cm
Pt=   EIRP in mW
Pi=   3.1416
R=    Measurement distance


2.3       MPE EVALUATION RESULTS
MPE Evaluation of Single Transmission
                    Maximum                                                       Power
  Frequency                    Rated Power          Antenna       Distance                         Limit
                    Conducted                                                    Density                 2
 Range (MHz)                      (dBm)             Gain (dBi)      (cm)                2        (mW/cm )
                   Power (dBm)                                                  (mW/cm )
 2402 ~ 2480              0.59            1.00          3.5             20        0.001                 1
 902.3 ~ 914.9            18.94           19.00         0               20        0.016             0.602

MPE Evaluation of Simultaneous Transmission
MPE Evaluation = Maximum MPE of BT LE + Maximum MPE of LoRa = 0.001 / 1 + 0.016 / 0.602 = 0.028 < 1

Conclusion
MPE evaluations of single and simultaneous transmission meet the requirement of standard.




Report No.: FA870901                                                                    Page : 5 of 6
Report Version: Rev. 01


C          Infernational
           Certification
           Corp.




3          Test laboratory information
Established in 2012, ICC provides foremost EMC & RF Testing and advisory consultation services by our
skilled engineers and technicians. Our services employ a wide variety of advanced edge test equipment and
one of the widest certification extents in the business.


International Certification Corp (EMC and Wireless Communication Laboratory), it is our definitive objective is
to institute long term, trust—based associations with our clients. The expectation we set up with our clients is
based on outstanding service, practical expertise and devotion to a certified value structure. Our passion is to
grant our clients with best EMC / RF services by oriented knowledgeable and accommodating staff.


Our Test sites are located at Linkou District and Kwei Shan District. Location map can be found on our
website http://www.icertifi.com.tw.


Linkou                                 Kwei Shan                            Kwei Shan Site II
Tel: 886—2—2601—1640                   Tel: 886—3—271—8666                  Tel: 886—3—271—8640
No. 30—2, Ding Fwu Tsuen, Lin          No. 3—1, Lane 6, Wen San 3rd St.,    No. 14—1, Lane 19, Wen San 3rd
Kou District, New Taipei City,         Kwei Shan District, Tao Yuan City    St., Kwei Shan District, Tao Yuan
Taiwan, R.0.C.                         333, Taiwan, R.O.C.                  City 333, Taiwan, R.O.C.

If you have any suggestion, please feel free to contact us as below information.

Tel: 886—3—271—8666
Fax: 886—3—318—0155
Email: ICC_Service@icertifi.com.tw




==END=




Report No.: FA870901                                                                       Page : 6 of 6
Report Version: Rev. 01



Document Created: 2018-08-21 15:19:39
Document Modified: 2018-08-21 15:19:39

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC