RF Exposure

FCC ID: MTFSX6TDFWT09

RF Exposure Info

Download: PDF
FCCID_1084701

                   Certification Exhibit



                  FCC ID: MTFSX6TDFWT09

                    FCC Rule Part: 22H, 24E

               ACS Report Number: 09-0077

                 Applicant: Telular Corporation




                         RF Exposure




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


                                          FCC ID: MTFSX6TDFWT09


General Information:
Applicant:                                   Telular Corporation
ACS Project:                                 09-0077
Device Category:                             Mobile
Environment:                                 General Population/Uncontrolled Exposure
Equipment Type:                              GSM/GPRS/EDGE Class 10 Module
Maximum Antenna Gain (800 MHz):              7.82dBi
Maximum Antenna Gain (1900 MHz):             3.01dBi

Power Limitations (Part 22.913 / 24.232):

                                           Peak Conducted Peak Conducted                                Part 22 / 24
 Frequency      Antenna     Antenna Gain                                          ERP       EIRP
                                                 Pwr            Pwr                                    ERP/EIRP Limit
   (MHz)       Gain (dBi)      (Num)                                              (W)        (W)
                                                (dBm)          (mW)                                         (W)

     836.4        7.82          6.05            32.10             1621.81         6.00      --------             7
     1880         3.01          2.00            30.00             1000.00        --------    2.00                2

Source-Based Time-Averaging Power Limitations (Part 2.1091):

This Class 10 GSM/GPRS/EDGE module includes a worst case source-based time-average duty factor of
0.25.

                                                                  Source-Based
               Peak          Peak        Duty Cycle                                                    Part 2.1091
 Frequency                                                        Time-Average      ERP      EIRP
           Conducted Pwr Conducted Pwr GSM/GPRS/EDGE                                                    ERP Limit
   (MHz)                                                               Pwr          (W)      (W)
               (dBm)         (mW)        (Class 10)                                                        (W)
                                                                      (mW)
   836.4         32.10          1621.81            0.25              405.45         1.50    --------       1.5
   1880          30.00          1000.00            0.25              250.00         0.31    --------        3
MPE Calculation:

The Power Density (mW/cm2) is calculated as follows:

      PG
S=
     4πR 2
Where:
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

               Power Density
 Frequency                                           Power Density
                  Limit           Distance (cm)
   (MHz)                                              (mW/cm^2)
                (mW/Cm2)
     836.4          0.56                20                0.488
     1880           1.00                20                0.099




                 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


                                        FCC ID: MTFSX6TDFWT09


Installation Guidelines
The installation manual should contain text similar to the following advising how to install the equipment to
maintain compliance with the FCC RF exposure requirements:

RF Exposure
In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element
shall be installed such that a minimum separation distance of 20 centimeters will be maintained.

Conclusion
This device complies with the MPE requirements by providing adequate separation between the device,
any radiating structure and the general population.




                5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598



Document Created: 2009-03-23 15:15:26
Document Modified: 2009-03-23 15:15:26

© 2024 FCC.report