FCC Part 1.1310 Test Report

FCC ID: MTD-0004

RF Exposure Info

Download: PDF
FCCID_3732629

                                                    Test Report
                                     Prepared for: Time Keeping Systems Inc.

                                              Model: Duress Device 10

                      Description: Wireless positioning and duress alarm for prison guards

                                                 Serial Number: N/A

                                                 FCC ID: MTD-0004

                                                          To

                                                  FCC Part 1.1310


                                          Date of Issue: January 29, 2018



On the behalf of the applicant:                   Time Keeping Systems Inc.
                                                  30700 Bainbridge Rd
                                                  Cleveland, OH 44139

Attention of:                                     Dean Chriss, Engineering Consultant
                                                  Ph: (216)595-1026
                                                  Email: dchriss@guard1.com




                                                   Prepared By
                                             Compliance Testing, LLC
                                                1724 S. Nevada Way
                                                  Mesa, AZ 85204
                                     (480) 926-3100 phone / (480) 926-3598 fax
                                            www.compliancetesting.com
                                               Project No: p1810006




                                                                        Kenneth Lee
                                                                        Project Test Engineer



         This report may not be reproduced, except in full, without written permission from Compliance Testing
                              All results contained herein relate only to the sample tested




                                                                                  p1810006_FCC_Part 1.1310_Rev 2.0
                                                                                                        Page 1 of 4


                              Test Report Revision History

Revision   Date               Revised By           Reason for Revision

    1.0    January 16, 2018   Kenneth Lee          Original Document
                                                   Updated Max Power used in calculation to
    2.0    January 29, 2018   Kenneth Lee
                                                   match manufacturer stated worst case.




                                                         p1810006_FCC_Part 1.1310_Rev 2.0
                                                                               Page 2 of 4


                                                 ILAC / A2LA
Compliance Testing, LLC, has been accredited in accordance with the recognized International Standard
ISO/IEC 17025:2005. This accreditation demonstrates technical competence for a defined scope and the
operation of a laboratory quality management system (refer joint ISO-ILAC-IAF Communiqué dated
January 2009)

The tests results contained within this test report all fall within our scope of accreditation, unless below

Please refer to http://www.compliancetesting.com/labscope.html for current scope of accreditation.

Testing Certificate Number: 2152.01




FCC Site Reg. #349717

IC Site Reg. #2044A-2


Non-accredited tests contained in this report:

N/A




EUT Description
Model: Duress Device 10
Description: Wirelss positioning and duress alarm for prison guards
Firmware: N/A
Software: N/A
Serial Number: N/A
Additional Information: The EUT implements a 3.3 dBi antenna.




                                                                       p1810006_FCC_Part 1.1310_Rev 2.0
                                                                                             Page 3 of 4


SAR Exclusion

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm are determined by:

[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,25 where

• f(GHz) is the RF channel transmit frequency in GHz
• Power and distance are rounded to the nearest mW and mm before calculation26
• The result is rounded to one decimal place for comparison
• 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below

The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and
for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test
exclusion.


Max Power in mW = 501 mW
Antenna Gain = 3.3 dB
Power with antenna gain = 1070 mW
                          263.5𝑢𝑠
Duty Cycle Correction =
                          100 𝑚𝑠
                                    = 0.002635 = 0.2635%
Corrected Power = 2.81945 mW
Min. Test Separation Distance = 1 mm
Frequency of Operation = 2402 MHz


2.81945 𝑚𝑊
             X√2.402 = 0.87393854
  5 𝑚𝑚




END OF TEST REPORT




                                                                    p1810006_FCC_Part 1.1310_Rev 2.0
                                                                                          Page 4 of 4



Document Created: 2019-09-06 23:44:50
Document Modified: 2019-09-06 23:44:50

© 2025 FCC.report