Test report HAC part 4

FCC ID: MSQX01AD

Test Report

Download: PDF
FCCID_4083966

Calibration Laboratory of                                                                                   S      Schweizerischer Kalibrierdienst
Schmid & Partner                                                                                                   Service suisse d'etalonnage
 Engineering AG
                                                                                                            C
                                                                                                                   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                s      Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                                          Accreditation No.:     SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client      Sporton                                                                             Certificate No:    CD835V3-1045_Sep18

CALIBRATION CERTIFICATE
 Object                                CD835V3 - SN: 1045


 Calibration procedure(s)              QA CAL-20.v6
                                       Calibration procedure for dipoles in air



 Calibration date:                     September 19, 2018

 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (SI).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 ± 3)°C and humidity < 70%.

 Calibration Equipment used (M&TE critical for calibration)
 Primary Standards                      ID#                        Cal Date (Certificate No.)                           Scheduled Calibration
 Power meter NAP                        SN: 104778                04-Apr-18 (No. 217-02672/02673)                       Apr-19
 Power sensor NRP-Z91                   SN: 103244                04-Apr-18 (No. 217-02672)                             Apr-19
 Power sensor NRP-Z91                   SN: 103245                04-Apr-18 (No. 217-02673)                             Apr-19
 Reference 20 dB Attenuator             SN: 5058 (20k)            04-Apr-18 (No. 217-02682)                             Apr-19
 Type-N mismatch combination            SN: 5047 .2 / 06327       04-Apr-18 (No. 217-02683)                             Apr-19
 Probe EF3DV3                           SN: 4013                  05-Mar-18 (No. EF3-4013_Mar18)                        Mar-19
 DAE4                                   SN: 781                   17-Jan-18 (No. DAE4-781 _Jan18)                       Jan-19



 Secondary Standards                    ID#                       Check Date (in house)                                 Scheduled Check
 Power meter Agilent 44196              SN: GB42420191            09-0ct-09 (in house check Oct-17)                     In house check: Oct-20
 Power sensor HP E4412A                 SN: US38485102            05-Jan-10 (in house check Oct-17)                     In house check: Oct-20
 Power sensor HP 8482A                  SN: US37295597            09-0ct-09 (in house check Oct-17)                     In house check: Oct-20
 RF generator R&S SMT-06                SN: 832283/01 1           27-Aug-12 (in house check Oct-17)                     In house check: Oct-20
 Network Analyzer Agilent E8358A        SN: US41080477            31-Mar-14 (in house check Oct-17)                     In house check: Oct- 18

                                        Name                                   Function                                 Signature
 Calibrated by:                         Leif Klysner                           Laboratory Technician



 Approved by:                           Katja Pokovic                          Technical Manager




                                                                                                                       Issued: September 24, 2018
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: CD835V3-1045_Sep 18                         Page 1 of 5


Calibration Laboratory of
Schmid & Partner
                                                                                           s   Schweizerischer Kalibrierdienst
                                                                                               Service suisse d'etalonnage
                                                                                           C
 Engineering AG                                                                                Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                               s   Swiss Calibration Service

Accredited by the Swiss Accreditation Service (SAS)                                        Accreditation No.:   SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates


References
[1]       ANSI-C63.19-2011
          American National Standard, Methods of Measurement of Compatibility between Wireless Communications
          Devices and Hearing Aids.
Methods Applied and Interpretation of Parameters:
      •   Coordinate System: y-axis is in the direction of the dipole arms. z-axis is from the basis of the antenna
          (mounted on the table} towards its feed point between the two dipole arms. x-axis is normal to the other axes.
          In coincidence with the standards [1 ], the measurement planes (probe sensor center) are selected to be at a
          distance of 15 mm above the top metal edge of the dipole arms.
      •   Measurement Conditions: Further details are available from the hardcopies at the end of the certificate. All
          figures stated in the certificate are valid at the frequency indicated. The forward power to the dipole connector
          is set with a calibrated power meter connected and monitored with an auxiliary power meter connected to a
          directional coupler. While the dipole under test is connected, the forward power is adjusted to the same level.
      •   Antenna Positioning: The dipole is mounted on a HAC Test Arch phantom using the matching dipole
          positioner with the arms horizontal and the feeding cable coming from the floor. The measurements are
          performed in a shielded room with absorbers around the setup to reduce the reflections.
          It is verified before the mounting of the dipole under the Test Arch phantom , that its arms are perfectly in a
          line. It is installed on the HAC dipole positioner with its arms parallel below the dielectric reference wire and
          able to move elastically in vertical direction without changing its relative position to the top center of the Test
          Arch phantom. The vertical distance to the probe is adjusted after dipole mounting with a DASY5 Surface
          Check job. Before the measurement, the distance between phantom surface and probe tip is verified. The
          proper measurement distance is selected by choosing the matching section of the HAC Test Arch phantom
          with the proper device reference point (upper surface of the dipole) and the matching grid reference point (tip
          of the probe) considering the probe sensor offset. The vertical distance to the probe is essential for the
          accuracy.
      •   Feed Point Impedance and Return Loss: These parameters are measured using a HP 8753E Vector Network
          Analyzer. The impedance is specified at the SMA connector of the dipole. The influence of reflections was
          eliminating by applying the averaging function while moving the dipole in the air, at least 70cm away from any
          obstacles.
      •   E-tield distribution: E field is measured in the x-y-plane with an isotropic ER3D-field probe with 100 mW
          forward power to the antenna feed point. In accordance with [1 ], the scan area is 20mm wide, its length
          exceeds the dipole arm length (180 or 90mm). The sensor center is 15 mm (in z) above the metal top of the
          dipole arms. Two 30 maxima are available near the end of the dipole arms. Assuming the dipole arms are
          perfectly in one line, the average of these two maxima (in subgrid 2 and subgrid 8) is determined to
          compensate for any non-parallelity to the measurement plane as well as the sensor displacement. The E-field
          value stated as calibration value represents the maximum of the interpolated 30-E-field, in the plane above
          the dipole surface.




 The reported uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the
 coverage factor k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%.




Certificate No: CD835V3-1045_Sep18                     Page 2 of 5


Measurement Conditions
    DASY svstem confiquration, as far as not aiven on paae 1.
      DASY Version                                               DASY5                        V52.10.1
      Phantom                                                HAC Test Arch
      Distance Dipole Top - Probe Center                         15 mm
      Scan resolution                                        dx, dy= 5 mm
      Frequency                                          835 MHz± 1 MHz
      Input power drift                                         < 0.05 dB



Maximum Field values at 835 MHz

      E-field 15 mm above dipole surface                            condition          Interpolated maximum
      Maximum measured above high end                         100 mW input power      109.3 Vim= 40.77 dBVlm
      Maximum measured above low end                          100 mW input power      108.2 Vim= 40.68 dBVlm
     Averaged maximum above arm                               100 mW input power      108.8 Vim± 12.8 % (k=2)



Appendix (Additional assessments outside the scope of SCS 0108)

Antenna Parameters

      Frequency                                                   Return Loss                Impedance
      800 MHz                                                        16.0 dB               40.8 Q - 11.3 jQ
      835 MHz                                                        32.3 dB               49.4 Q + 2.3 jQ
      880 MHz                                                        18.1 dB               57.9 Q - 11.0 jQ
      900 MHz                                                        18.2 dB               48.3 Q -12.1 jQ
      945 MHz                                                        20.5 dB               49.1 Q + 9.3 jQ



3.2 Antenna Design and Handling

The calibration dipole has a symmetric geometry with a built-in two stub matching network, which leads to the
enhanced bandwidth.
The dipole is built of standard semi rigid coaxial cable. The internal matching line is open ended. The antenna is
therefore open for DC signals.
Do not apply force to dipole arms, as they are liable to bend. The soldered connections near the feedpoint may be
damaged. After excessive mechanical stress or overheating, check the impedance characteristics to ensure that the
internal matching network is not affected.

After long term use with 40W radiated power, only a slight warming of the dipole near the feedpoint can be measured.




Certificate No: CD835V3-1045_Sep18             Page 3 of 5


Impedance Measurement Plot




      File         View   Channel    Sweep     Calibration   Trace       Scale   Marker—      System        Window     Help

        10.00             811                                                                                                         dpooo0 M            958 d8
        s.00                                                                                                                   ;     5—000000—MH        30.31548
                                                                                                                                   200 (PODGO MHz      —18.10448
        0.00                                        ==—i———                                                            T           sotopooot hhie      "To T990F)
        s on                                                         Bs                                                    s       _____§a5 00000 We     i 52208
        F10.00                                                                                                     (
        H15.00                                                                                                     “

        L20.00                                                                      BA                _Lesx34—[/
                                                                                         \I       /          6
        25.00                                                                                                +
             f                                                                                T
                                                                                              [
        F20.00
        F35.00
        H0.00        Ch 1 Aug= 20
            Ch1: Start 395.000 MHe        ——                                                                                                     Stop 1.33500 GHz


                                                                                                                           1       500 000000 MHz        40753 0
                                                                                                                                          17 £80 pF
                                                                                                                           2       #35 000000 MHz
                                                                                                                                         442 05 pH
                                                                                                                                   @80 000000 MHz
                                                                                                                                          16 511 pF
                                                                                                                           4       400 000000 MHz
                                                                                                                                          14 6R4pF
                                                                                                                           5       245 000000 MHz
                                                                                                                                         15710 nH




                          Ch1Aug= 20
                 Ch1: Start 395.000 MHa   ——                                                                                                     Stop 1.33500 GHz

        Status            CH 1:     ETI                      C* 1—Port                            Avg=20 Delay                                         LCL




Certificate No: CD835V3—1045_Sep18                               Page 4 of 5


DASY5 E-field Result

                                                                                              Date: 19.09.20 18

Test Laboratory: SPEAG Lab2

DUT: HAC-Dipole 835 MHz; Type: CD835V3; Serial: CD835V3 - SN: 1045

Communication System: UID O - CW ; Frequency: 835 MHz
Medium parameters used: cr = 0 Sim, e, = I ; p = 0 kg/m3
Phantom section: RF Section
Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-20 1 l )

DASY52 Configuration:

    •   Probe : EF3DV3 - SN4013; ConvF(l, 1, 1) @ 835 MHz; Calibrated : 05.03.2018
    •   Sensor-Surface: (Fix Surface)
    •   Electronics: DAE4 Sn781; Calibrated: 17.01.2018
    •   Phantom : HAC Test Arch with AMCC; Type: SD HAC POl BA; Serial : 1070
    •   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)



Dipole E-Field measurement@ 835MHz/E-Scan - 835MHz d=15mm/Hearing Aid Compatibility Test (41x361xl):
Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value= 132.0 V/m; Power Drift= 0.00 dB
Applied MIF = 0.00 dB
RF audio interference level= 40.77 dBV/m
Emission category: M3
                                         MIF scaled E-field

                                          Grid 1 M3      Grid 2 M3    Grid 3 M3
                                          40.25 dBV/m 40.68 dBV/m 40.63 dBV/m

                                          Grid 4 M4      Grid 5 M4    Grid 6 M4
                                          35.68 dBV/m 35.97 dBV/m 35.93 dBV/m

                                          Grid 7 M3      Grid 8 M3    Grid 9 M3
                                          40.47 dBV/m 40.77 dBV/m 40.67 dBV/m



             dB
             D


              -1.92


              -3.84


              -5.77


              -7.69


              -9.61
                        0 dB = 109.3 V/m = 40.77 dBV/m




Certificate No: CD835V3-1045_Sep18              Page 5 of 5


Calibration Laboratory of
Schmid & Partner
                                                                                                            s
                                                                                                            C
                                                                                                                   Schweizerischer Kalibrierdienst
                                                                                                                   Service suisse d'etalonnage
 Engineering AG                                                                                                    Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                s      Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                                          Accreditation No.:     SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client      Sporton                                                                             Certificate No:    CD1880V3-1038_Sep18

!CALIBRATION CERTIFICATE
 Object                                CD1880V3 - SN: 1038


 Calibration procedure(s)              QA CAL-20.v6
                                       Calibration procedure for dipoles in air




 Calibration date:                     September 19, 2018

 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (SI).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 ± 3)°C and humidity < 70%.

 Calibration Equipment used (M&TE critical for calibration)
 Primary Standards                      ID#                       Cal Date (Certificate No.)                            Scheduled Calibration
 Power meter NAP                        SN: 104778                04-Apr-18 (No. 217-02672/02673)                       Apr-19
 Power sensor NRP-291                   SN: 103244                04-Apr-18 (No. 217-02672)                             Apr-1 9
 Power sensor NRP-291                   SN: 103245                04-Apr-1 8 (No. 217-02673)                            Apr-19
 Reference 20 dB Attenuator             SN: 5058 (20k)            04-Apr-18 (No. 217-02682)                             Apr-1 9
 Type-N mismatch combination            SN: 5047.2 / 06327        04-Apr-18 (No. 217-02683)                             Apr-19
 Probe EF3DV3                           SN: 4013                  05-Mar-18 (No. EF3-4013_Mar18)                        Mar-19
 DAE4                                   SN: 781                    17-Jan-18 (No. DAE4-781_Jan18)                      Jan-19



 Secondary Standards                    ID#                       Check Date (in house)                                 Scheduled Check
 Power meter Agilent 4419B              SN: GB42420191            09-0ct-09 (in house check Oct-17)                     In house check: Oct-20
 Power sensor HP E4412A                 SN: US38485102            05-Jan-10 (in house check Oct-17)                     In house check: Oct-20
 Power sensor HP 8482A                  SN: US37295597            09-0ct-09 (in house check Oct-17)                     In house check: Oct-20
 RF generator R&S SMT-06                SN: 832283/011            27-Aug-12 (in house check Oct-17)                     In house check: Oct-20
 Network Analyzer HP 8358A              SN: US41080477            31-Mar-14 (in house check Oct-17)                     In house check: Oct-18

                                        Name                                   Function                                 Signature
 Calibrated by:                         Leif Klysner                           Laboratory Technician



 Approved by:                           Katja Pokovic                          Technical Manager




                                                                                                                       Issued: September 24, 2018
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: CD1880V3-1038_Sep18                         Page 1 of 7


Calibration Laboratory of
Schmid & Partner
                                                                                           s   Schweizerischer Kalibrierdienst
                                                                                               Service suisse d'etalonnage
                                                                                           C
 Engineering AG                                                                                Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                               s   Swiss Calibration Service

Accredited by the Swiss Accreditation Service (SAS)                                        Accreditation No.:   SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates


References
[1]       ANSI-C63.19-2011
          American National Standard, Methods of Measurement of Compatibility between Wireless Communications
          Devices and Hearing Aids.
Methods Applied and Interpretation of Parameters:
      •   Coordinate System: y-axis is in the direction of the dipole arms. z-axis is from the basis of the antenna
          (mounted on the table) towards its teed point between the two dipole arms. x-axis is normal to the other axes.
          In coincidence with the standards [1], the measurement planes (probe sensor center) are selected to be at a
          distance of 15 mm above the top metal edge of the dipole arms.
      •   Measurement Conditions: Further details are available from the hardcopies at the end of the certificate. All
          figures stated in the certificate are valid at the frequency indicated. The forward power to the dipole connector
          is set with a calibrated power meter connected and monitored with an auxiliary power meter connected to a
          directional coupler. While the dipole under test is connected, the forward power is adjusted to the same level.
      •   Antenna Positioning: The dipole is mounted on a HAC Test Arch phantom using the matching dipole
          positioner with the arms horizontal and the feeding cable coming from the floor. The measurements are
          performed in a shielded room with absorbers around the setup to reduce the reflections.
          It is verified before the mounting of the dipole under the Test Arch phantom, that its arms are perfectly in a
          line. It is installed on the HAC dipole positioner with its arms parallel below the dielectric reference wire and
          able to move elastically in vertical direction without changing its relative position to the top center of the Test
          Arch phantom. The vertical distance to the probe is adjusted after dipole mounting with a DASY5 Surface
          Check job. Before the measurement, the distance between phantom surface and probe tip is verified. The
          proper measurement distance is selected by choosing the matching section of the HAC Test Arch phantom
          with the proper device reference point (upper surface of the dipole) and the matching grid reference point (tip
          of the probe) considering the probe sensor offset. The vertical distance to the probe is essential tor the
          accuracy.
      •   Feed Point Impedance and Return Loss: These parameters are measured using a HP 8753E Vector Network
          Analyzer. The impedance is specified at the SMA connector of the dipole. The influence of reflections was
          eliminating by applying the averaging function while moving the dipole in the air, at least 70cm away from any
          obstacles.
      •   E-field distribution: E field is measured in the x-y-plane with an isotropic ER3D-field probe with 100 mW
          forward power to the antenna feed point. In accordance with [1 J, the scan area is 20mm wide, its length
          exceeds the dipole arm length (180 or 90mm). The sensor center is 15 mm (in z) above the metal top of the
          dipole arms. Two 3D maxima are available near the end of the dipole arms. Assuming the dipole arms are
          perfectly in one line, the average of these two maxima (in subgrid 2 and subgrid 8) is determined to
          compensate for any non-parallelity to the measurement plane as well as the sensor displacement. The E-field
          value stated as calibration value represents the maximum of the interpolated 3D-E-field, in the plane above
          the dipole surface.




 The reported uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the
 coverage factor k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%.




Certificate No: CD1880V3-1038_Sep18                    Page 2 of 7


Measurement Conditions
    DA SY svstem configuration, as far as not aiven on page 1.
      DASY Version                                               DASY5                    V52.10.1
      Phantom                                                HAC Test Arch
      Distance Dipole Top - Probe Center                         15 mm
     Scan resolution                                         dx, dy=5 mm
                                                         1730 MHz± 1 MHz
      Frequency
                                                         1880 MHz± 1 MHz
      Input power drift                                        < 0.05 dB



Maximum Field values at 1730 MHz

      E-field 15 mm above dipole surface                           condition       Interpolated maximum
      Maximum measured above high end                         100 mW input power   97.0 Vim= 39.74 dBV/m
      Maximum measured above low end                          100 mW input power   96.0 Vim= 39.65 dBV/m
     Averaged maximum above arm                               100 mW input power   96.5 Vim± 12.8 % (k=2)



Maximum Field values at 1880 MHz

      E-field 15 mm above dipole surface                           condition       Interpolated maximum
     Maximum measured above high end                          100 mW input power   90.3 Vim= 39.11 dBV/m
     Maximum measured above low end                           100 mW input power   88.8 Vim= 38.97 dBV/m
     Averaged maximum above arm                               100 mW input power   89.5 Vim ± 12.8 % (k=2)




Certificate No: CD1880V3-1038_Sep18            Page 3 of 7


Appendix (Additional assessments outside the scope of SCS 0108)

Antenna Parameters

Nominal Frequencies

      Frequency                                              Return Loss                     Impedance
      1730 MHz                                                  22.9 dB                    55.7 Q + 5.1 jQ
      1880 MHz                                                  21.2 dB                    59.3 Q + 2.0 jQ
      1900 MHz                                                  21.6 dB                     59.1 Q-1.1 jQ
      1950 MHz                                                  25.9 dB                     50.7 Q -5.0 jQ
      2000 MHz                                                  20.7 dB                    43.8 Q + 6.1 jQ

Additional Frequencies

      Frequency                                              Return Loss                     Impedance
      1730 MHz                                                  22.9 dB                    55.7 Q + 5.1 jQ



3.2 Antenna Design and Handling

The calibration dipole has a symmetric geometry with a built-in two stub matching network, which leads to the
enhanced bandwidth.
The dipole is built of standard semirigid coaxial cable. The internal matching line is open ended. The antenna is
therefore open for DC signals.
Do not apply force to dipole arms, as they are liable to bend. The soldered connections near the feedpoint may be
damaged. After excessive mechanical stress or overheating, check the impedance characteristics to ensure that the
internal matching network is not affected.

After long term use with 40W radiated power, only a slight warming of the dipole near the feedpoint can be measured.




Certificate No: CD1880V3-1038_Sep18          Page 4 of 7


Impedance Measurement Plot




     File     Yiew    Channel     Sweep     Calibration   Trace       Scale Marker   System    Window     Help
       7 0                                                                                                                   000                  6 dB
       200                                                                                                   a      1 4e0000.544             212g548
        5            _                                                                                           __—+        notorz          2T 3940E
       [**"                  ==E——                                                                          3       —rfamorone              se
       s on                            >                                                                  _4—s      > 100000 nite            on79048

       F13.00
       Fis.00                                                                                         /
                                                                                                 lj
       es oo                                                    +               e    B    LC
                                                                  1                       y
       Lze.00                                                         >                   z7
       F33.00
       F38.00
       F43.00                 = |20
             Ch1: Start 1.38000 GHa—   ——                                                                                            Stop 2.38000 GHz


                                                                                                             1          30                   55 664 0
                                                                                                                        465 71 pH
                                                                                                             2      1 ©80000 GHz                 66
                                                                                                                            b4pH             2 0038 0
                                                                                                                    1900000 GHz              59 058 0
                                                                                                                         79        539 pF     110531 0
                                                                                                             4      1 $50000 GHz             50 704 0
                                                                                                                         16 182 pF           3      a
                                                                                                             5     2000000 GHe
                                                                                                                         481.73pH            6,0536 0




                      Ch1 Aug= 20
             Chi: Start 1.38000 GHe    ——                                                                                           Stop 2.38000 GHz

       Status        CH 1:                                C* 1—Port                  Avg=20 Delay                                           LCL




Certificate No: CD1880V3—1038_Sep18                           Page 5 of 7


DASY5 E-field Result

                                                                                                        Date: 19.09.2018

Test Laboratory: SPEAG Lab2

DUT: HAC Dipole 1880 MHz; Type: CD1880V3; Serial: CD1880V3 - SN: 1038

Communication System: UID O - CW ; Frequency: 1880 MHz, Frequency: 1730 MHz
Medium parameters used: cr = 0 Sim,£,= I; p = 0 kg/m 3
Phantom section: RF Section
Measurement Standard: DASY5 (IEEE/IEC/ ANSI C63.I9-2011 )

DASY52 Configuration:

    •   Probe: EF3DV3 - SN4013; ConvF(l, 1, 1)@ 1880 MHz, ConvF{l, 1, 1)@ 1730 MHz; Calibrated: 05.03.2018
    •   Sensor-Surface: {Fix Surface)
    •   Electronics: DAE4 Sn781; Calibrated: 17.01.2018
    •   Phantom: HAC Test Arch with AMCC; Type: SD HAC POl BA; Serial: 1070
    •   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)



Dipole E-Field measurement@ 1880MHz/E-Scan - 1880MHz d=l5mm/Hearing Aid Compatibility Test (4lxl8lxl):
Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Re ference Point: 0, 0, -6.3 mm
Reference Value = 155.2 V/m; Power Drift= -0.03 dB
Applied MlF = 0.00 dB
RF audio interference level = 39. 11 dBV/m
Emission category: M2
                                        MIF scaled E-field

                                        Grid 1 M2      Grid 2 M2    Grid 3 M2
                                        38.75 dBV/m 39.11 dBV/m 39.05 dBV/m

                                        Grid 4 M2      Grid 5 M 2   Grid 6 M2
                                        36.11 dBV/m 36.24 dBV/m 36.17 dBV/m

                                        Grid 7 M2      Grid 8 M2    Grid 9 M2
                                        38.77 dBV/m 38.97 dBV/m 38.81dBV/m




Certificate No: CD1880V3-1038_ Sep18          Page 6 of 7


Dipole E-Field measurement@ 1730MHz/E-Scan - 1730MHz d=15mm/Hearing Aid Compatibility Test (41x181xl):
Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0 , -6.3 mm
Reference Value= 168.4 V/m; Power Drift= 0.00 dB
Applied MIF = 0.00 dB
RF audio interference level= 39.74 dBV/m
Emission category: M2
                                      MIF scaled E-field

                                       Grid 1 M2       Grid 2 M2   Grid 3 M2
                                       39.27 dBV/m 39.65 dBV/m 39.59dBV/m
                                       Grid 4 M2       Grid 5 M2   Grid 6 M2
                                       36.98dBV/m 37.17 dBV/m 37.12 dBV/m

                                       Grid 7 M2       Grid 8 M2   Grid 9 M2
                                       39.5 dBV/m      39.74 dBV/m 39.61 dBV/m




             dB
              0


             -0.97


             -1.95


             -2.92


             -3.90


             -4.87
                       0 dB= 90.29 V/m = 39.11 dBV/m




Certificate No: CD1880V3-1038_Sep18         Page 7 of 7


Calibration Laboratory of                                         Dz+
                                                                  SA                                        S      Schweizerischer Kalibrierdienst
          &                                                      &              *
Schmid & Partner                                                ili‘\\—//mfi—‘:                              ( Service suisse d‘étalonnage
   Engmeenng AG                                                  2 Z4z                                             Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                     7 4ޤ                                      S      Swiss Calibration Service
                                                                     Torlet S

Accredited by the Swiss Accreditation Service (SAS)                                                          Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client        Sporton                                                                           Certificate No: CD2600V3—1018_Aug18

ICALIBRATION CERTIFICATE                                                                                                                             |
 Object                                CD2600V3 — SN: 1018


 Calibration procedure(s)              QA CAL—20.v6
                                       Calibration procedure for dipoles in air




 Calibration date:                     August 22, 2018


 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)

 Primary Standards                      ID #                       Cal Date (Certificate No.)                           Scheduled Calibration
 Power meter NRP                        SN: 104778                 04—Apr—18 (No. 217—02672/02673)                      Apr—19
 Power sensor NRP—Z91                   SN: 103244                 04—Apr—18 (No. 217—02672)                            Apr—19
 Power sensor NRP—Z91                   SN: 103245                 04—Apr—18 (No. 217—02673)                            Apr—19
 Reference 20 dB Attenuator             SN:    5058 (20k)          04—Apr—18 (No. 217—02682)                            Apr—19
 Type—N mismatch combination            SN:    5047.2 / 06327      04—Apr—18 (No. 217—02683)                            Apr—19
 Probe EF3DV3                           SN:    4013                05—Mar—18 (No. EF3—4013_Mar18)                       Mar—19
 DAE4                                   SN:    781                 17—Jan—18 (No. DAE4—781_Jan18)                       Jan—19



 Secondary Standards                    ID #                       Check Date (in house)                                Scheduled Check
 Power meter Agilent 4419B              SN: GB42420191             09—Oct—09 (in house check Oct—17)                    in house check: Oct—20
 Power sensor HP E4412A                 SN: US38485102            05—Jan—10 (in house check Oct—17)                     in house check: Oct—20
 Power sensor HP 8482A                  SN: US37205597            09—Oct—09 (in house check Oct—17)                     In house check: Oct—20
 RF generator R&S SMT—06                SN: 832283/011            27—Aug—12 (in house check Oct—17)                     in house check: Oct—20
 Network Analyzer HP 8358A              SN: US41080477            31—Mar—14 (in house check Oct—17)                     In house check: Oct—18


                                        Name                                    Function                                Signature
 Calibrated by:                         Jeton Kastrati                          Laboratory Technician

                                                                                                                            (ZGe
 Approved by:                           KatJa Pokovic                           Technical Manager
                                                                                                                   C—
                                                                                                                       Issued: August 23, 2018
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: CD2600V3—1018_Aug18                         Page 1 of 5


Calibration Laboratory of
Schmid & Partner
                                                                                           s   Schweizerischer Kalibrierdienst
                                                                                               Service suisse d'etalonnage
 Engineering AG
                                                                                           C
                                                                                               Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                               s   Swiss Calibration Service

Accredited by the Swiss Accreditation Service (SAS)                                        Accreditation No.:   SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates


References
[1]       ANSI-C63.19-2011
          American National Standard , Methods of Measurement of Compatibility between Wireless Communications
          Devices and Hearing Aids .
Methods Applied and Interpretation of Parameters:
      •   Coordinate System: y-axis is in the direction of the dipole arms. z-axis is from the basis of the antenna
          (mounted on the table) towards its feed point between the two dipole arms. x-axis is normal to the other axes.
          In coincidence with the standards [1 ], the measurement planes (probe sensor center) are selected to be at a
          distance of 15 mm above the top metal edge of the dipole arms.
      •   Measurement Conditions: Further details are available from the hardcopies at the end of the certificate. All
          figures stated in the certificate are valid at the frequency indicated. The forward power to the dipole connector
          is set with a calibrated power meter connected and monitored with an auxiliary power meter connected to a
          directional coupler. While the dipole under test is connected, the forward power is adjusted to the same level.
      •   Antenna Positioning: The dipole is mounted on a HAC Test Arch phantom using the matching dipole
          positioner with the arms horizontal and the feeding cable coming from the floor. The measurements are
          performed in a shielded room with absorbers around the setup to reduce the reflections.
          It is verified before the mounting of the dipole under the Test Arch phantom, that its arms are perfectly in a
          line. It is installed on the HAC dipole positioner with its arms parallel below the dielectric reference wire and
          able to move elastically in vertical direction without changing its relative position to the top center of the Test
          Arch phantom. The vertical distance to the probe is adjusted after dipole mounting with a DASY5 Surface
          Check job. Before the measurement, the distance between phantom surface and probe tip is verified. The
          proper measurement distance is selected by choosing the matching section of the HAC Test Arch phantom
          with the proper device reference point (upper surface of the dipole) and the matching grid reference point (tip
          of the probe) considering the probe sensor offset. The vertical distance to the probe is essential for the
          accuracy.
      •   Feed Point Impedance and Return Loss: These parameters are measured using a HP 8753E Vector Network
          Analyzer. The impedance is specified at the SMA connector of the dipole. The influence of reflections was
          eliminating by applying the averaging function while moving the dipole in the air, at least 70cm away from any
          obstacles.
      •   E-field distribution: E field is measured in the x-y-plane with an isotropic ER3D-field probe with 100 mW
          forward power to the antenna feed point. In accordance with [1 J, the scan area is 20mm wide, its length
          exceeds the dipole arm length (180 or 90mm). The sensor center is 15 mm (in z) above the metal top of the
          dipole arms. Two 3D maxima are available near the end of the dipole arms. Assuming the dipole arms are
          perfectly in one line, the average of these two maxima (in subgrid 2 and subgrid 8) is determined to
          compensate for any non-parallelity to the measurement plane as well as the sensor displacement. The E-field
          value stated as calibration value represents the maximum of the interpolated 3D-E-field, in the plane above
          the dipole surface.




 The reported uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the
 coverage factor k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%.




Certificate No: CD2600V3-1018_Aug18                    Page 2 of 5


Measurement Conditions
    DASY svstem configuration, as far as not Qiven on paQe 1.
      DASY Version                                              DASY5                         V52.10.1
      Phantom                                               HAC Test Arch
      Distance Dipole Top - Probe Center                        15 mm
      Scan resolution                                       dx, dy=5 mm
      Frequency                                         2600 MHz± 1 MHz
      Input power drift                                       < 0.05 dB



Maximum Field values at 2600 MHz

      E-field 15 mm above dipole surface                          condition            Interpolated maximum
      Maximum measured above high end                        100 mW input power        86.0 V/m = 38.69 dBV/m
      Maximum measured above low end                         100 mW input power        85.7 V/m = 38.66 dBV/m
      Averaged maximum above arm                             100 mW input power        85.8 Vim± 12.8 % (k=2)



Appendix (Additional assessments outside the scope of SCS 0108)

Antenna Parameters

      Frequency                                                 Return Loss                  Impedance
      2450 MHz                                                     19.4 dB                 43.5 Q - 7.6 jQ
     2550 MHz                                                      28.9 dB                 47.1 Q+ 1.9jQ
      2600 MHz                                                     32.9 dB                 49.8 Q + 2.2 jQ
     2650 MHz                                                      33.6 dB                 52.0 Q + 0.8 jQ
     2750 MHz                                                      22.1 dB                 50.9 Q - 7.9 jQ



3.2 Antenna Design and Handling

The calibration dipole has a symmetric geometry with a built-in two stub matching network, which leads to the
enhanced bandwidth.
The dipole is built of standard semirigid coaxial cable. The internal matching line is open ended. The antenna is
therefore open for DC signals.
Do not apply force to dipole arms, as they are liable to bend. The soldered connections near the feedpoint may be
damaged. After excessive mechanical stress or overheating, check the impedance characteristics to ensure that the
internal matching network is not affected.

After long term use with 40W radiated power, only a slight warming of the dipole near the feedpoint can be measured.




Certificate No: CD2600V3-1018_Aug18           Page 3 of 5


Impedance Measurement Plot




     File       View     Channel     Sweep    Calibration    Trace       Scale   Marker—   System   Window    Help
       7.00            dBsi                                                                                          1           2 450000 GHe        1944206
       200                                                                                                                       2 dsa008.o4           so248
       he                                                                                                         4              2400000 Ghz
       L3 o0           h=                                                                                         T              TSUOQEane
       s.00                      .                                                                                &              popmtiinn ake      >> no8 ar
            e                            \\__7                                                                               "
       F13.00                                      ———                                                                   <
                                                            ie
       HMs.00                                                    >                                            z
                                                                      >
       Les.on                                                         A.._——
                                                                                                          5
       Les.0n                                                                    e
       Las.00                                                                          sk _
       Las.on                                                                                 4
       L4s.00       Ch 1 Aug= [20
           Chi: Start 2.10000 GHz        ——                                                                                                  Stop 3.10000 GHez
                                                                                                                                            se

                                                                                                                  1              2450000 GHz
                                                                                                                                     2 5436 pF

                                                                                                                                     11941 pH
                                                                                                                  2              2600000 GHz
                                                                                                                                        37 69 pH
                                                                                                                  4              2 £50000 GHe


                                                                                                                  5              2750000 GHz
                                                                                                                                     7.3100 pF




                           18ug= 20
            Ch1: Start      210000 GHa   ——                                                                                                  Stop 3.10000 GHz

                         CH 1:                              C* 1—Port                      Ava=20 Delay                                            LCL




Certificate No: CD2600V3—1018_Aug18                                  Page 4 of 5


DASYS E-field Result

                                                                                               Date: 22.08.2018

Test Laboratory: SPEAG Lab2

DUT: HAC Dipole 2600 MHz; Type: CD2600V3; Serial: CD2600V3. SN: 1018

Communication System: UID O • C W ; Frequency: 2600 MHz
Medium para meters used: o = 0 Sim, s, = I ; p = O kg/m3
Phantom section: RF Section
Measure ment Standard: DAS Y5 (IEEE/IEC/ANSI C63. I9-2011 )

DASY52 Configuration:

    •   Probe: EF3DV3 - SN4013; ConvF(l, 1, 1)@ 2600 MHz; Calibrated: 05.03.2018
    •   Sensor-Surface: (Fix Surface)
    •   Electronics: DAE4 Sn781; Calibrated: 17.01.2018
    •   Phantom: HAC Test Arch with AMCC; Type: SD HAC POl BA; Serial: 1070
    •   DASYS2 52.10.1(1476); SEMCAD X 14.6.11(7439)



Dipole E-Field measurement @ 2600MHz/E-Scan · 2600MHz d=15mm/Hearing Aid Compatibility Test (41xl81xl):
Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0 , 0, -6.3 mm
Reference Value = 64.13 V /m; Power Ori ft = 0.00 dB
Applied MIF = 0.00 dB
RF audio interference level= 38.69 dBV/m
Emission category: M2
                                        MIF scaled E-field

                                        Grid 1 M2        Grid 2 M2   Grid 3 M2
                                        38.4 dBV/m       38.69 dBV/m 38.62 dBV/m

                                        Grid 4 M2        Grid 5 M2   Grid 6 M2
                                        37.92 dBV/m 38.1 dBV/m       38.04dBV/m

                                        Grid 7 M2        Grid 8 M2   Grid 9 M2
                                        38.47 dBV/m 38.66dBV/m 38 .53 dBV/m



             dB
              0


             -1.42


             -2.84


             -4.25


             -5.67


             -7.09
                        0 dB = 86.00 V/m = 38.69 dBV/m




Certificate No: CD2600V3-1018_Aug18           Page 5 of 5


Calibration Laboratory of                                                                                          Schweizerischer Kalibrierdienst
Schmid & Partner                                                                                                   Service suisse d‘étalonnage
   Engineering AG                                                                                                  Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                       Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                             Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Muitilateral Agreement for the recognition of calibration certificates

Client       Sporton                                                                            Certificate No: DAE4—854_Jun18

CALIBRATION CERTIFICATE                                                                                                                              I
 Object                                DAE4 — SD 000 DO4 BM — SN: 854


 Calibration procedure(s)              QA CAL—06.v29
                                       Calibration procedure for the data acquisition electronics (DAE)



 Calibration date:                     June 14, 2018




 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


 Primary Standards                      ID #                      Cal Date (Certificate No.)                           Scheduled Calibration
 Keithley Multimeter Type 2001          SN: 0810278               31—Aug—17 (No:21092)                                 Aug—18

 Secondary Standards                    ID #                      Check Date (in house)                                Scheduled Check
 Auto DAE Calibration Unit              SE UWS 053 AA 1001        04—Jan—18 (in house check)                           In house check: Jan—19
 Calibrator Box V2.1                    SE UMS 006 AA 1002        04—Jan—18 (in house check)                           In house check: Jan—19




                                        Name                                   Function
 Calibrated by:                         Eric Hainfeld                          Laboratory Technician




                                                                                                                          \ N ./&me
 Approved by:                           Sven Kiuhn                             Deputy Manager



                                                                                                                        Issued: June 14, 2018
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: DAE4—854_Jun18                                        Page 1 of 5


Calibration Laboratory of                                                     $   Schweizerischer Kalibrierdienst
Schmid & Partner                                                              C   Service suisse d'etalonnage
 Engineering AG                                                                   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                  S   Swiss Calibration Service


 Accredited by the Swiss Accreditation Se Nice (SAS)                          Accreditation No.:   SCS 0108
 The Swiss Accreditation Service is one of the signatories to the EA
 Multilateral Agreement for the recognition of calibration certificates



Glossary
DAE                          data acquisition electronics
Connector angle              information used in DASY system to align probe sensor X to the robot
                             coordinate system.

Methods Applied and Interpretation of Parameters
  •   DC Voltage Measurement: Calibration Factor assessed for use in DASY system by
     comparison with a calibrated instrument traceable to national standards. The figure given
     corresponds to the full scale range of the voltmeter in the respective range.
     •    Connector angle: The angle of the connector is assessed measuring the angle
          mechanically by a tool inserted. Uncertainty is not required.
     •    The following parameters as documented in the Appendix contain technical information as a
          result from the performance test and require no uncertainty.
         •     DC Voltage Measurement Linearity: Verification of the Linearity at +10% and -10% of
               the nominal calibration voltage. Influence of offset voltage is included in this
               measurement.
         •     Common mode sensitivity: Influence of a positive or negative common mode voltage on
               the differential measurement.
         •     Channel separation: Influence of a voltage on the neighbor channels not subject to an
               input voltage.
         •     AD Converter Values with inputs shorted: Values on the internal AD converte r
               corresponding to zero input voltage
         •     Input Offset Measurement Output voltage and statistical results over a large number of
               zero voltage measurements.
         •     Input Offset Current: Typical value for information; Maximum channel input offset
               current, not considering the input resistance.
         •     Input resistance: Typical value for information: DAE input resistance at the connector,
               during internal auto-zeroing and during measurement.
         •     Low Battery Alarm Voltage: Typical value for information. Below this voltage, a battery
               alarm signal is generated.
         •     Power consumption: Typical value for information. Supply currents in various operating
               modes.




Certificate No: DAE4-854_Jun18                                  Page 2 of 5


DC Voltage Measurement
    AID - Converter Resolution nominal
        High Range:          1LS8 =     6.1µV,        full range= -100 ... +300 mV
        Low Range:           1LS8 =     61nV,         full range= -L ..... +3mV
    DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec

      Calibration Factors              X                           y                       z
      High Range             404.937 ± 0.02% (k=2)    404. 730± 0.02% (k=2)   405.829 ± 0.02% (k=2)
      Low Range              3.97284 ± 1.50% (k=2)    3.94535 ± 1.50% (k=2)   3.99553 ± 1 .50% (k=2)


Connector Angle

      Connector Angle to be used in DASY system                                    325.0   °±1 °




Certificate No: DAE4-854_Jun18                       Page 3 of 5


Appendix (Additional assessments outside the scope of SCS0108)

1. DC Voltaae Linearitv
      High Range                               Reading (µV)         Difference (µV)               Error(%)
      Channel X       + Input                   200033.40                   -4.54                  -0.00
      ChannelX        + Input                   20004.28                    -1.77                  -0.01
      ChannelX        - Input                   -20002.65                   2.58                  -0.01
      Channel Y       + Input                   200036.32                   -2.03                 -0.00
      Channel Y       + Input                   20002.05                    -3.86                 -0.02
      ChannelY        - Input                   -20005.10                   0.28                  -0.00
      ChannelZ        + Input                   200036.91                  -1.46                  -0.00
      ChannelZ        + Input                   20003.85                   -2.05                  -0.01
      ChannelZ        - Input                   -20005.17                   0.36                  -0.00


      Low Range                                Reading (µV)         Difference (µV)               Error{%)
      ChannelX        + Input                    2002.16                    0.22                   0.01
      ChannelX        + Input                    202.15                     0.38                   0.19
      Channel X       - Input                    -198.29                   -0.31                   0.16
      Channel Y       + Input                    2001.95                    0.27                   0.01
      ChannelY        + Input                    201.01                    -0.63                  -0.31
      Channel Y       - Input                    -198.91                   -0.79                   0.40
      Channel Z       + Input                    2001.73                   -0.08                  -0.00
      Channel Z       + Input                    200.57                    -1.12                  -0.56

      ChannelZ        - Input                    -199.68                   -1.47                   0.74



2. Common mode sensitivity
    DASY measurement parameters: Auto Zero Time: 3 sec; Measunno time: 3 sec

                        Common mode                       High Range                           Low Range
                        Input Voltage (mV)            Average Reading (µV)                Average Reading (µV)

     ChannelX                           200                     -11.94                         -13.63
                                       -200                     15.47                           13.71
     Channel Y                          200                     -8.45                           -8.32
                                       - 200                     7.64                           7.27
     ChannelZ                           200                     16.23                          16.03
                                       - 200                    -18.86                         -19.07



3. Channel separation
    DASY measurement parameters: Auto Zero Time: 3 sec; Measurina time: 3 sec
                       Input Voltage (mV)         Channel X (µV)         Channel Y (µV)       Channel Z (µV)
     Channel X                   200                       -                  1.45                 -3.45
     Channel Y                   200                   7.54                     -                  3.39
    ChannelZ                     200                   9.04                   5.14                      -

Certificate No: DAE4-854_Jun18                             Page 4 of 5


 4. AD-Converter Values with inputs shorted
     DASY measurement parameters: Auto Zero Time: 3 sec; Measurina time: 3 sec

                                                     High Range (LSB)                      Low Range (LSB)

     Channel X                                               16138                              16479

     ChannelY                                               16030                               14603

     Channel Z                                              15846                               16180



5. Input Offset Measurement
    DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec
    Input 10MQ
                                                                                                 Std. Deviation
                            Average (µV)        min. Offset (µV)         max. Offset (µ V)
                                                                                                      (µV)
     ChannelX                    0.51                 -0.22                       1.41                 0.30
     Channel Y                   1.02                 -0.44                       1.87                 0.35
     Channel Z                   0.62                 -0.69                       1.46                 0.38



6. Input Offset Current .
     Nominal Input circuitry offset current on all channels: <25fA


7. In out Resistance        (Tvoical values for information)
                                                  Zeroing (kOhm)                          Measuring (MOhm)
     ChannelX                                              200                                  200
     Channel Y                                             200                                  200
     Channel Z                                             200                                  200



8. Low Batterv Al arm VI
                       o taae            (Typical values for information)
     Typical values                               Alarm Level (VDC)
     Supply(+ Vee)                                                                 +7.9
     Supply(· Vee)                                                                 -7.6



9. Power Consumot1on             (Typical values for information)
     Typical values                         Switched off (mA)        Stand by (mA)           Transmitting (mA)
     Supply(+ Vee)                                 +0.01                    +6                     +14
     Supply (- Vee)                                -O.Q1                     -8                       -9




Certificate No: DAE4-854_Jun18                             Page 5 of 5


Calibration Laboratory of                                                                                   S       Schweizerischer Kalibrierdienst
Schmid & Partner                                                                                                    Service suisse d'etalonnage
 Engineering AG                                                                                             C
                                                                                                                    Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                s       Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                                         Accreditation No.:     SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client      Sporton (Auden                                                                     Certificate No:


CALIBRATION CER't-lFICATE
 Object                               ER30V6 - SN:2358


 Calibration procedure(s)             QA CAL-02.v8, QA CAL-25.v6
                                      Calibration procedure for E-field probes optimized for close near field
                                      evaluations in air

 Calibration date:                     JanuarY 19, 2018

 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (SI).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 ± 3)°C and humidity< 70% .


 Calibration Equipment used (M&TE critical for calibration)



  Primary Standards                   ID                                 Cal Date (Certificate No.)                     Scheduled Calibration
  Power meter NRP                     SN : 104778                        04-Apr-17 (No. 217-02521/02522)                Apr-18
  Power sensor NRP-291                SN: 103244                         04-Apr-17 (No. 217-02521)                      Apr-18
  Power sensor NRP-291                SN: 103245                         04-Apr-17 (No. 217-02525)                      Apr-18
  Reference 20 dB Attenuator          SN : S5277 (20x)                   07-Apr-17 (No. 217-02528)                      Apr-18
  Reference Probe ER3DV6              SN: 2328                           1O-Oct-17 (No. ER3-2328_ 0ct17)                Oct-18
  DAE4                                SN : 789                           2-Aug-17 (No. DAE4-789 Aug17)                  Aug-18


  Secondary Standards                 ID                                 Check Date (in house)                          Scheduled Check
  Power meter E4419B                  SN: GB41293874                     06-Apr-16 (in house check Jun-16)              In house check: Jun-18
  PowersensorE4412A                   SN: MY41498087                     06-Apr-16 (in house check Jun-16)              In house check: Jun-18
  PowersensorE4412A                   SN: 000110210                      06-Apr-16 (in house check Jun-16)              In house check: Jun-18
  RF generator HP 8648C               SN: US3642U01700                   04-Aug-99 (in house check Jun-16)              In house check: Jun- 18
  Network Analyzer HP 8753E           SN : US37390585                    18-0ct-01 (in house check Oct-17)              In house check: Oct-18

                                           Name                                 Function
  Calibrated by:                           Michael Weber                        Laboratory Technician


  Approved by:




                                                                                                                          Issued: January 24, 2018
  This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




 Certificate No: ER3-2358_Jan18                                        Page 1 of 10


Calibration Laboratory of                        «U                                    Sehvezcschr Kalbrinaieost
Schmid & Partner                                 §                               8. Simiammecsoomge
  Engineering AG                                 fecsen                          § simicontizns 6 wraten
Zrogronntami5  A006 murcn,Suinetacd              zww                                Bvem Gatraton Servcn
Acerndtoo tSutes Acrtaicn Surve (808)                                             sconttaionns: SCS 0108
Te Ssn Accndtrion Service in oot n gnatore o eA
MutitrnAgrvemantfor hn ecoqnton afcatbraton cntthcnen
Glossary:
NoRMxy.z                sensitiy in roe spece
DoP                     diode compression pont
c                       crestfacto(1/duty_cxle) of the REF signal
A.8,G.D                 modulation dependontinsarization parameters
Polazation 0            s retation around probe axis
Polaricaton 8           8 rotaion around an axs tatis in the plane normal o probe ax‘s (emeesuement conta)
                        te, $ «0 is normaito probe sxis
Connector Argle         Infomation used in DASY system to algn probe sensorX to therobot coottinats systom
Callbration is Performed According to the Following Standards:
    a) 1EEE Sid 1900—200,° IEEE Standard or caibration of electromagnatlsfeld sensors and probes, exctiding
        antennas, rom 9 kiz to 40 GHz, December 2005
    8}. TA Test Plan for Hoaring Ald Compatibiy, Rev 20, Novermber 2013
M'mods Applied and Interprotation of Parameters:
      NORMry.z:Assessed foE—teld polatzaion & = 0 for XY sensors and = 90 forZ sensor(f s $00 Mz in
      TElcel1 > 1800 Miiz: RZ2 waveguide)
    + NORM(Meyce= NORMbcy.z * fuquency_response (see Freaency Response Char}
    +    0CPry.a: DOP are numedical ncarzation paremetere assossebased on the date of power sweep with CW
         signal (no uncerisinlyrequires). DCP does not degend on freguency nor media
    + PARPAR is the Peak to Average Ratlo thais not caltraled but deternined based on the signal
      characterstis
      +0ABuyiz: Coy.z; DaVRky,2. A, B C, D are numercalincarizaton paramrelers assessed based on
       the data o power sweep for peciic mouiaton sgral. The marametars do not epend on requency nor
       madia. VR s the maximum calteation range sxpressed in RNMG votage across t clode.
      * Spherca! soty (3D deviaton rom isotropy};in a localy homageneous feldreatzed usingan open
         wavequde sotup.
      + Sensor Offset The sensor ffset correspondl to the offset o vriual measurement center rom the probe tp
        (oprobe ax‘s. No tolrance requred
      + ComectorArgle: The angle is assessed using ths information gained by determinin the NOR(no
         uncerainy requirec)




 Confcate No: ER32382.anto                           Page 2t to


ER3DV6 - SN :2358                                                                January 19, 2018




                     Probe ER3DV6

                                          SN:2358

                                   Manufactured:            July 7, 2005
                                   Calibrated:              January 19, 2018



                                  Calibrated for DASY/EASY Systems
                                     (Note: non-compatible with DASY2 system!)




 Certificate No: ER3-2358_Jan18                     Page 3 of 10


ER3DV6 - SN :2358                                                                                                          January 19, 2018




DASY/EASY - Parameters of Probe: ER3DV6 - SN:2358

Basic Calibration Parameters
                                               Sensor X                          SensorY                    SensorZ               Unc (k=2)
 Norm (µV/(V/m)°'")                               1.66                            1.51                        1.54                ± 10.1 %
 DCP (mV) 0                                       99.2                            100.2                       100.5



Modulation Calibration Parameters
 UID          Communication System Name                                    A           B            C          D          VR          Unct:
                                                                           dB        dBv'µV                   dB          mV          (k=2)
 0            cw                                                 X         0.0        0.0          1.0        0.00       226.7       ±3.3 %
                                                                 y         0.0        0.0          1.0                   199.5
                                                                 z         0.0        0.0          1.0                   190.1
 10021-       GSM-FDD (TDMA, GMSK)                               X        19.82       99.3        27.8        9.39       121 .6      ±2.2%
 DAC
                                                                 y        14.37       93.3        26.1                   106.4
                                                                 z        12.91       89.7        24 .8                  137.0
 10172-        LTE-TDD (SC-FDMA, 1 RB , 20 MHz,                  X        10.00       85.0        32 .5       9.21       147.1       ±2.2%
 CAD           QPSK)
                                                                 y        8.48        79.0        29 .0                  126.2
                                                                 z        7.90        75.6        26.6                   117.5
    10173-     LTE-TDD (SC-FDMA, 1 RB , 20 MHz,                   X       10.28       85 .1       32.5        9.48       147.0       ±2.2%
    CAD        16-QAM)
                                                                  y       8.76        79 .2        29 .0                 125.8
                                                                  z       8.31        76.5         27.1                  117.3
    10174-     LTE-TDD (SC-FDMA, 1 RB , 20 MHz,                   X       10.72       84.7         33.4       10.25      147.7       ±2.5%
    CAD        64-QAM)
                                                                  y       9.41         79 .5       30.2                  126.5
                                                                  z       8.84         76.3        27.8                  117.9
    10295-     CDMA2000, RC1 , S03, 118th Rate 25 fr.             X       14.87        99 .4       41 .3      12.49      110.4       ±1 .9 %
    AAB
                                                                  y       15.41        99 .6       41.0                   95.8
                                                                  z       11.45        87 .5       34.5                   87.4



    The reported uncertainty of measurement is stated as the standard uncertainty of measurement
    multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
    probability of approximately 95%.

8
  Numerical linearization parameter: uncertainty not required .
E Uncertainty is determined using the max. deviation from linear response applying rectangular distribution and is expressed for the square of the
field value .




 Certificate No: ER3-2358_Jan18                                       Page 4 of 10


ersove— swzoss                                                                                                  danuary19, 2018

                                              Frequency Response of E—Field
                                                   (TEM—Cellifi110 EXX, Waveguide: R22)




                                        15
                                        16
                                        134
       Frequeney response (normaized)




                                                             Daggccucaa
                                                             t     1    i                    oc           aul          :
                                                                         1e             2%        25‘00         2000
                                                                         uooo
                                                                     )             Te
                                              Uncertainty of Frequency Responise of E—feld: £6.3% (=2)




 Cerifcale No ERS2080.Jnto                                           Page Sot to


sxsove— snzase                                                                   Janvary 19, 2018



                              Receiving Pattern (§), 9 = 0°

                  £—600 MHz, TEM,0°                              £=2500 Miz,R22.0°




            /£C                                             &1                        A

           f                      .     :                  $




          To+                      f
                               * k“.;
                                        f
                                        +
                                                          Tn«


                              Receiving Pattern (§), 9 = 90°

                  (2800 MHz.TEM.90°                              1=2500 MHz,R22,00°




 Gorifeme No ER:—2388_Jmnte                 Page set to


eraove— suzose                                                                           Jandary 1o,2018

                               Receiving Pattern (§), 9 = 0°



          E.
     €E   oo


          ashecd
               E5   E3                      4C                      #4 B
                                                       nor
                 wfi                        «fls                   mfths                witth
                             Uncertainty of AxtalIsotropy Assessment: £0.5% (ke)



                               Receiving Pattern (¢), 9 = 90°




      &            ;                                      t
      © vepmagor
           eonnceis prieag 6.5c0.5+

          s                                  :                      i
                   io           Te C        4            t
                                                       mam
                                                                    44A    ob
                       «Bd                  ob                   nafth  wotth
                              Uncertalnt of Axtal Ieotropy Assonsmant: % 0.5% (ke2)




 Certfcate No: ER—2050.onte                        Paget o 10


ensove— uzse                                                                                        Janoaryto, 2018



                                            Dynamic Range f(E—field)
                                                    (TEM cell , f 00 Miz)


                               10e
                               ¢
               tnput Sgnalo)




                                     io                  to                                    10
                                                                 Ettal Vin)
                                                    ce
                                              rot eimpensated                  whies
                                                                                 s




                                                                     AEERT T


                                      oe                  for                 3               10
                                                                 Eout NWm
                                                                              conporisins
                                                     i




                                           Uncertainty of Linearity Assessment: £0.6% (c ~a



 Cortfcate No RG—2388_ionta                                     Page8ot 10


ER3DV6- SN :2358                                                                                    January 19, 2018


                                  Deviation from Isotropy in Air
                                                  Error (cl>, S), f = 900 MHz



                           1.0
                           0.8
                           0.6
                       c:: 0.4
                        0
                       16 0.2
                       -~ 0 .0
                        O -0.2
                            -0.4
                            -0 .6
                             -0.8




                                                                      0




                         -1.0       -0.8   -0.6   -0.4   -0.2   0.0   0.2   0.4   0.6   0.8   1.0

                             Uncertainty of Spherical Isotropy Assessment: ± 2.6% (k=2)




 Certificate No: ER3-2358_Jan18                             Page 9 of 10


ER3DV6 - SN :2358                                          January 19, 2018




DASY/EASY - Parameters of Probe: ER3DV6 - SN:2358

Other Probe Parameters
 Sensor Arrangement                                          Rectangular
                     0
 Connector Angle (       )                                          118.7
 Mechanical Surface Detection Mode                               enabled
 Optical Surface Detection Mode                                  disabled
 Probe Overall Length                                            337 mm
 Probe Body Diameter                                               10 mm
 Tip Length                                                        10 mm
 Tip Diameter                                                       8mm
 Probe Tip to Sensor X Calibration Point                          2.5mm
 Probe Tip to Sensor Y Calibration Point                          2.5mm
 Probe Tip to Sensor Z Calibration Point                          2.5mm




 Certificate No: ER3-2358_Jan18            Page 10 of 10



Document Created: 2019-03-27 07:56:50
Document Modified: 2019-03-27 07:56:50