DXX Test Report

FCC ID: MSQI01WDX

Test Report

Download: PDF
FCCID_4334069

                                                               FCC Test Report

                                                                   (Spot Check)

                       Report No.: RF190507C02-4

                             FCC ID: MSQI01WDX

               Original FCC ID: MSQI01WD

                       Test Model: ASUS_I01WDX

                 Received Date: May 07, 2019

                         Test Date: May 11 ~ May 16, 2019

                     Issued Date: May 29, 2019


                         Applicant: ASUSTek COMPUTER INC.

                           Address: 4F, No. 150, LI-TE Rd., PEITOU, TAIPEI 112, TAIWAN


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                                 (R.O.C.)
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)
         FCC Registration / 788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to
us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such
notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your
unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the
uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.


Report No.: RF190507C02-4                                             Page No. 1 / 15                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         Summary of Test Results ..................................................................................................................... 5
    2.1      Measurement Uncertainty ................................................................................................................... 5
    2.2      Modification Record ............................................................................................................................ 5
3         General Information .............................................................................................................................. 6
    3.1      General Description of EUT ................................................................................................................ 6
    3.2      Description of Test Modes ................................................................................................................... 6
    3.2.1    Test Mode Applicability and Tested Channel Deta .............................................................................. 7
    3.3      Description of Support Units ............................................................................................................... 7
    3.3.1    Configuration of System under Test .................................................................................................... 7
    3.4      General Description of Applied Standards .......................................................................................... 7
4         Test Types and Results ........................................................................................................................ 8
    4.1      Radiated Emission Measurement ....................................................................................................... 8
    4.1.1    Limits of Radiated Emission Measurement ......................................................................................... 8
    4.1.2    Test Instruments .................................................................................................................................. 9
    4.1.3    Test Procedures................................................................................................................................. 10
    4.1.4    Deviation from Test Standard ............................................................................................................. 11
    4.1.5    Test Set Up ......................................................................................................................................... 11
    4.1.6    EUT Operating Conditions.................................................................................................................. 11
    4.1.7    Test Results ....................................................................................................................................... 12
5         Pictures of Test Arrangements .......................................................................................................... 14
Appendix – Information of the Testing Laboratories ................................................................................. 15




Report No.: RF190507C02-4                                            Page No. 2 / 15                                             Report Format Version: 6.1.1


                                          Release Control Record


Issue No.              Description                                        Date Issued
RF190507C02-4          Original release                                   May 29, 2019




Report No.: RF190507C02-4                    Page No. 3 / 15       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: ASUS Phone

              Brand: ASUS

              Model: ASUS_I01WDX

    Sample Status: Identical Prototype

          Applicant: ASUSTek COMPUTER INC.

          Test Date: May 11 ~ May 16, 2019

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.225)
                        47 CFR FCC Part 15, Subpart C (Section 15.215)
                        ANSI C63.10:2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                              , Date:         May 29, 2019
                            Pettie Chen / Senior Specialist




     Approved by :                                               , Date:         May 29, 2019
                            Bruce Chen / Project Engineer




Report No.: RF190507C02-4                      Page No. 4 / 15                        Report Format Version: 6.1.1


2     Summary of Test Results

                            47 CFR FCC Part 15, Subpart C (Section 15.225, 15.215)
       FCC
                                Test Item                   Result                   Remarks
      Clause
                The field strength of any emissions               Meet the requirement of limit.
    15.225 (d)  appearing outside of the                 Pass     Minimum passing margin is -6.6dB at
                13.110-14.010 MHz band                            30.97MHz.
Note: Determining compliance based on the results of the compliance measurement, not taking into account
      measurement instrumentation uncertainty.

2.1    Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16-4-2:
                                                                                 Expanded Uncertainty
                  Measurement                               Frequency
                                                                                         (k=2) (±)
                                                         9kHz ~ 30MHz                     3.04 dB
        Radiated Emissions up to 1 GHz                  30MHz ~ 200MHz                    3.86 dB
                                                       200MHz ~1000MHz                    3.87 dB


2.2    Modification Record
There were no modifications required for compliance.




Report No.: RF190507C02-4                      Page No. 5 / 15                        Report Format Version: 6.1.1


3     General Information
3.1    General Description of EUT

 Product                     ASUS Phone
 Brand                       ASUS
 Model                       ASUS_I01WDX
 Sample Status               Identical Prototype
                             3.85 Vdc (Battery)
 Power Supply Rating         5 or 9 Vdc (Adapter)
                             5 Vdc (Host equipment)
 Modulation Type             ASK
 Operating Frequency         13.56MHz
 Field Strength              11.1dBuV/m (30m)
 Antenna Type                Loop antenna
 Accessory Device            Refer to Note as below
 Data Cable Supplied         Refer to Note as below
Note:
1. This report is a supplementary report to the original BV CPS report no.: RF190114C07-5. Exhibit prepared
   for FCC Spot Check Verification report, the format, test items and amount of spot-check test data are
   decided by applicant's engineering judgment, for more details please refer to declaration letter exhibit.
   Radiated emission verification worst test refer to original report.
2. The EUT accessories list refers to EUT Photo.pdf.


3.2    Description of Test Modes
1 channel is provided to this EUT
         Channel                                               Freq. (MHz)
              1                                                  13.56




Report No.: RF190507C02-4                    Page No. 6 / 15                        Report Format Version: 6.1.1


3.2.1        Test Mode Applicability and Tested Channel Deta

 EUT Configure                        Applicable to
                                                                                             Description
    Mode                                   RE
         -                                 √                         -
Where         RE: Radiated Emission


Note: The EUT had been pre-tested on the positioned of each 3 axis. The worst case was found when positioned on Z-plane.


Radiated Emission Test:
      Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
      between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
      Following channel(s) was (were) selected for the final test as listed below.
      EUT Configure Mode                 Available Channel               Tested Channel                  Modulation Type
                   -                             1                              1                              ASK


Test Condition:
        Applicable to             Environmental Conditions                Input Power                      Tested by
              RE                       24 deg. C, 64% RH                  120Vac, 60Hz                     Match Tsui




3.3     Description of Support Units
The EUT has been tested as an independent unit.


3.3.1        Configuration of System under Test




                         Earphone (EUT)                                   EUT

                          Adapter (EUT)




3.4     General Description of Applied Standards
The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:

FCC Part 15, Subpart C (15.225)
FCC Part 15, Subpart C (15.215)
ANSI C63.10-2013

All test items have been performed and recorded as per the above standards.




Report No.: RF190507C02-4                              Page No. 7 / 15                                Report Format Version: 6.1.1


4     Test Types and Results
4.1     Radiated Emission Measurement
4.1.1    Limits of Radiated Emission Measurement
The field strength of any emissions within the band 13.553-13.567 MHz shall not exceed 15,848
microvolts/meter at 30 meters.

Within the bands 13.410-13.553 MHz and 13.567-13.710 MHz, the field strength of any emissions shall not
exceed 334 microvolts/meter at 30 meters.

Within the bands 13.110-13.410 MHz and 13.710-14.010 MHz the field strength of any emissions shall not
exceed 106 microvolts/meter at 30 meters.

The field strength of any emissions appearing outside of the 13.110-14.010 MHz band shall not exceed the
general radiated emission limits in § 15.209.


         Frequencies (MHz)           Field Strength (microvolts/meter)   Measurement Distance (meters)

            0.009 ~ 0.490                      2400/F(kHz)                             300
            0.490 ~ 1.705                     24000/F(kHz)                             30
            1.705 ~ 30.0                             30                                30
               30 ~ 88                              100                                 3
              88 ~ 216                              150                                 3
              216 ~ 960                             200                                 3
             Above 960                              500                                 3
Note:
1.    The lower limit shall apply at the transition frequencies.
2.    Emission level (dBuV/m) = 20 log Emission level (uV/m).
3.    For frequencies above 1000MHz, the field strength limits are based on average detector, however, the
      peak field strength of any emission shall not exceed the maximum permitted average limits, specified
      above by more than 20dB under any condition of modulation.




Report No.: RF190507C02-4                    Page No. 8 / 15                       Report Format Version: 6.1.1


4.1.2   Test Instruments
       Description &
                                 Model No.                   Serial No.          Cal. Date          Cal. Due
       Manufacturer
Test Receiver
                                    ESCI                         100424        Jan. 03, 2019     Jan. 02, 2020
ROHDE & SCHWARZ
Spectrum Analyzer
                                   FSU43                         100115        Jan. 21, 2019     Jan. 20, 2020
ROHDE & SCHWARZ
Spectrum Analyzer
                                   FSP40                         100040        Sep. 25, 2018 Sep. 24, 2019
ROHDE & SCHWARZ
BILOG Antenna
                                 VULB9168                    9168-155          Nov. 21, 2018     Nov. 20, 2019
SCHWARZBECK
HORN Antenna
                                BBHA 9120D                  9120D-1170         Nov. 25, 2018 Nov. 24, 2019
SCHWARZBECK
HORN Antenna
                                 BBHA 9170                BBHA9170241          Nov. 25, 2018 Nov. 24, 2019
SCHWARZBECK
Loop Antenna
                                  HLA 6121                       45745         Jun. 14, 2018     Jun. 13, 2019
TESEQ
Preamplifier
Agilent                            8447D                   2944A10631          Aug. 08, 2018 Aug. 07, 2019
(Below 1GHz)
Preamplifier
KEYSIGHT                           83017A                  MY53270295          Jul. 02, 2018     Jul. 01, 2019
(Above 1GHz)
RF signal cable WOKEN              8D-FB                  Cable-CH3-01         Aug. 21, 2018 Aug. 20, 2019
RF signal cable
                              SUCOFLEX 104            MY 13380+295012/04       Aug. 08, 2018 Aug. 07, 2019
HUBER+SUHNER
RF signal cable
                              SUCOFLEX 104          Cable-CH4-03 (250724)      Aug. 08, 2018 Aug. 07, 2019
HUBER+SUHNER
Software                       ADT_Radiated_
                                                                  NA                NA                 NA
BV ADT                          V7.6.15.9.5
Antenna Tower
                                  MA 4000                        010303             NA                 NA
inn-co GmbH
Antenna Tower Controller
                                   AT100                   AT93021703               NA                 NA
BV ADT
Turn Table
                                   TT100                   TT93021703               NA                 NA
BV ADT
Turn Table Controller
                                   SC100                   SC93021703               NA                 NA
BV ADT
Boresight Antenna Fixture          FBA-01                   FBA-SIP01               NA                 NA

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
         to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Chamber 3.




Report No.: RF190507C02-4                      Page No. 9 / 15                         Report Format Version: 6.1.1


4.1.3   Test Procedures
For Radiated emission below 30MHz

a.   The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
     room. The table was rotated 360 degrees to determine the position of the highest radiation.
b.   The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c.   Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the
     measurement.
d.   For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
     from 0 degrees to 360 degrees to find the maximum reading.
e.   The test-receiver system was set to Quasi-Peak Detect Function or except (9-90 kHz, 110-490 kHz) for
     Average Detect Function and Specified Bandwidth with Maximum Hold Mode.
Note:
1.   The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9kHz at frequency
     below 30MHz.
2.   There is a comparison data of both open-field test site and semi-Anechoic chamber, and the result came
     out very similar.

For Radiated emission above 30MHz

a.   The EUT was placed on the top of a rotating table 0.8 meters (for 30MHz ~ 1GHz) / 1.5 meters (for above
     1GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to
     determine the position of the highest radiation.
b.   The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c.   The height of antenna is varied from one meter to four meters above the ground to determine the
     maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
     make the measurement.
d.   For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
     to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to
     find the maximum reading.
e.   The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
     hold mode when the test frequency is below 1 GHz.
f.   The test-receiver system was set to peak and average detect function and specified bandwidth with
     maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
     average limit, measurement with the average detector is unnecessary.
Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
    Quasi-peak detection (QP) at frequency below 1GHz.
2.   The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
     for Peak detection (PK) at frequency above 1GHz.
3.   The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video bandwidth is ≥ 1/T
     (Duty cycle < 98%) or 10Hz (Duty cycle ≥ 98%) for Average detection (AV) at frequency above 1GHz.
4.   All modes of operation were investigated and the worst-case emissions are reported.




Report No.: RF190507C02-4                     Page No. 10 / 15                        Report Format Version: 6.1.1


4.1.4   Deviation from Test Standard
No deviation.

4.1.5   Test Set Up
For Radiated emission below 30MHz


                                                                                   1m
            EUT&                               3m
            Support Units

                                    Turn Table

                80cm


                                           Ground Plane
                                            Test Receiver




For Radiated emission 30MHz to 1GHz

                                                               Ant. Tower
                                                                                      1-4m
                                                                                      Variable
                EUT&
                                               3m
                                                10m
                Support Units

                                         Turn Table

                   80cm


                                              Ground Plane

                                              Test Receiver




For the actual test configuration, please refer to the attached file (Test Setup Photo).

KDB 414788 OATS and Chamber Correlation Justification
- Based on FCC 15.31 (f) (2): measurements may be performed at a distance closer than that specified in
  regulations; however, an attempt should be made to avoid making measurements in the near field.
- Open-field site and chamber correlation testing had been performed and chamber measured test result is
  the worst case test result.

4.1.6   EUT Operating Conditions

a. Set the EUT under transmission condition continuously at specific channel frequency.



Report No.: RF190507C02-4                       Page No. 11 / 15                           Report Format Version: 6.1.1


4.1.7   Test Results


EUT Test Condition                                         Measurement Detail
Channel                     Channel 1                      Frequency Range            Below 1000MHz
Input Power                 120Vac, 60Hz                   Detector Function          Quasi-Peak
Environmental Conditions 24 deg. C, 64% RH                 Tested By                  Match Tsui

                                Antenna Polarity & Test Distance: Horizontal At 3m
                     Emission                                  Antenna       Table        Raw          Correction
          Freq.                       Limit       Margin
No.                    Level                                    Height      Angle         Value         Factor
         (MHz)                      (dBuV/m)       (dB)
                     (dBuV/m)                                     (m)      (Degree)      (dBuV)         (dB/m)
 1       30.97        33.4 QP         40.0         -6.6         1.00 H         5          44.8           -11.4
 2       745.86       31.3 QP         46.0        -14.7         1.49 H         1          30.7            0.6
 3       826.37       31.4 QP         46.0        -14.6         1.00 H        75          29.3            2.1
 4       866.14       31.8 QP         46.0        -14.2         1.00 H        76          29.1            2.7
 5       893.30       32.9 QP         46.0        -13.1         1.49 H        206         30.1            2.8
 6       935.98       32.9 QP         46.0        -13.1         1.49 H        316         29.0            3.9


Remarks:
           1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
           2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
           3. The other emission levels were very low against the limit.
           4. Margin value = Emission Level – Limit value




Report No.: RF190507C02-4                       Page No. 12 / 15                         Report Format Version: 6.1.1


EUT Test Condition                                        Measurement Detail
Channel                     Channel 1                     Frequency Range            Below 1000MHz
Input Power                 120Vac, 60Hz                  Detector Function          Quasi-Peak
Environmental Conditions 24 deg. C, 64% RH                Tested By                  Match Tsui

                                Antenna Polarity & Test Distance: Vertical At 3m
                     Emission                                 Antenna       Table        Raw          Correction
          Freq.                      Limit       Margin
No.                    Level                                   Height      Angle         Value         Factor
         (MHz)                     (dBuV/m)       (dB)
                     (dBuV/m)                                    (m)      (Degree)      (dBuV)         (dB/m)
 1       30.00        33.3 QP        40.0         -6.7         1.50 V        190         44.5           -11.2
 2       66.86        27.1 QP        40.0        -12.9         1.00 V        272         38.1           -11.0
 3       870.02       32.8 QP        46.0        -13.2         1.50 V         91         30.1            2.7
 4       902.03       33.1 QP        46.0        -12.9         1.00 V        204         30.1            3.0
 5       922.40       33.3 QP        46.0        -12.7         1.00 V        156         29.5            3.8
 6       945.68       33.4 QP        46.0        -12.6         1.00 V        352         29.2            4.2


Remarks:
           1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
           2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
           3. The other emission levels were very low against the limit.
           4. Margin value = Emission Level – Limit value




Report No.: RF190507C02-4                      Page No. 13 / 15                         Report Format Version: 6.1.1


5    Pictures of Test Arrangements
Please refer to the attached file (Test Setup Photo).




Report No.: RF190507C02-4                      Page No. 14 / 15   Report Format Version: 6.1.1


Appendix – Information of the Testing Laboratories
We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited and approved according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Lin Kou EMC/RF Lab                                    Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                   Tel: 886-3-6668565
Fax: 886-2-26051924                                   Fax: 886-3-6668323

Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892

Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF190507C02-4                     Page No. 15 / 15                  Report Format Version: 6.1.1



Document Created: 2019-06-17 13:22:10
Document Modified: 2019-06-17 13:22:10

© 2025 FCC.report