Test Report HAC RF Appendix A

FCC ID: MSQI001D

Test Report

Download: PDF
FCCID_4378891

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab       Date: 2019/6/12


HAC_E_Dipole_835

DUT: HAC Dipole 835 MHz

Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: 0 = 0 S/m, & = 1; p = 0 kg/m>
Armbient Temperature : 23.4 °C

DASY5S Configuration:
— Probe: EF3DV3 — SN4047; ConvF(1, 1, 1) @ 835 MHz; Calibrated: 2019/1/30
— Sensor—Surface: (Fix Surface)
— Electronics: DAE4 Sn854; Calibrated: 2019/5/21
— Phantom: HAC Test Arch with AMCC; Type: SD HAC POI BA;
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan — measurement distance from the probe sensor center to CD835 = 10mm & 15mm/Hearing
Aid Compatibility Test at 1 5mm distance (41x361x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, —6.3 mm
Reference Value = 130.1 V/m; Power Drift = 0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E—field emissions = 114.1 V/m
Average value of Total=(114.1+112.3) /2 =113.2 V/m

                                               PMF scaled E—field

                                                Grid 1 M4 Grid 2 M4 Grid 3 M4
                                                114.1 V/m 114.1 V/m 108.9 V/m
                                                Grid 4 M4 Grid 5 M4 Grid 6 M4
                                                62.77 V/m 63.04 V/m 60.41 V/m
                                                Grid 7 M4 Grid 8 M4 Grid 9 M4
                                                112.3 V/m 112.3 V/m 107.3 V/m
                                                                Cursor:
                                                           Total = 114.1 V/m
                                                           E Category: M4
                                                       Location: 3, —72, 9.7 mm




               —2.06


               —4.12


               —6.17


               —8.23


               —10.29
                           —
                          0 dB =114.1 V/m =41.15 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab         Date: 2019/6/12


HAC_E_Dipole_1880
DUT: HAC Dipole 1880 MHz

Communication System: CW; Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.4 ℃

DASY5 Configuration:
- Probe: EF3DV3 - SN4047; ConvF(1, 1, 1) @ 1880 MHz; Calibrated: 2019/1/30
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2019/5/21
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - measurement distance from the probe sensor center to CD1880 = 10mm & 15mm/Hearing
Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 156.6 V/m; Power Drift = 0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 88.18 V/m
Average value of Total=(88.18+86.98) / 2 = 87.58 V/m

                                               PMF scaled E-field
                                                Grid 1 M3 Grid 2 M3 Grid 3 M3
                                                87.86 V/m         88.18 V/m   84.75 V/m
                                                Grid 4 M3         Grid 5 M3   Grid 6 M3
                                                65.32 V/m         65.42 V/m   63.97 V/m
                                                Grid 7 M3         Grid 8 M3   Grid 9 M3
                                                86.26 V/m         86.98 V/m   84.07 V/m
                                                              Cursor:
                                                         Total = 88.18 V/m
                                                           E Category: M3
                                                      Location: 1.5, -33, 9.7 mm




                          0 dB = 88.18 V/m = 38.91 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab        Date: 2019/6/12


HAC_E_Dipole_2450
DUT: HAC Dipole 2450 MHz

Communication System: CW; Frequency: 2450 MHz;Duty Cycle: 1: 1
Medium: Air Medium parameters used: 0 = 0 S/m, & = 1; p = 0 kg/m>
Arabient Temperature : 23.4 °C

DASY5S Configuration:
— Probe: EF3DV3 — SN4047; ConvF(1, 1, 1) @ 2450 MHz; Calibrated: 2019/1/30
— Sensor—Surface: (Fix Surface)
— Electronics: DAE4 Sn854; Calibrated: 2019/5/21
— Phantom: HAC Test Arch with AMCC; Type: SD HAC POI BA;
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan — measurement distance from the probe sensor center to CD2450 = 10mm & 15mm
/Hearing Aid Compatibility Test at 15mm distance (41x181x1):; Interpolated grid: dx=0.5000 mm,
dy=0.5000 mm
Device Reference Point: 0, 0, —6.3 mm
Reference Value = 8$2.90 V/m; Power Drift = 0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E—field emissions = 87.77 V/m
Average value of Total=(86.05+87.77) / 2 = 86.91 V/m

                                               PMF scaled E—field

                                                Grid 1 M3 Grid 2 M3 Grid 3 M3
                                                $5.34 V/m 8$6.05 V/m $2.83 V/m
                                                Grid 4 M3 Grid 5 M3 Grid 6 M3
                                                76.71 V/m 77.17 V/m 75.24 V/m
                                                Grid 7 M3 Grid 8 M3 Grid 9 M3
                                                86.03 V/m $7.77 V/m 8$5.79 V/m
                                                                Cursor:
                                                           Total = 87.77 V/m
                                                            E Category: M3
                                                       Location: 0, 24.5, 9.7 mm




               —1.36


               —2.13


               —4.09


               —5.46


               —6.82
                           —
                          0 dB =8$7.77 V/m = 38.87 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab        Date: 2019/6/12


HAC_E_Dipole_2600

DUT: HAC Dipole 2600 MHz

Communication System: CW ; Frequency: 2600 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: 0 = 0 S/m, & = 1; p = 0 kg/m>
Arabient Temperature : 23.4 °C

DASY5S Configuration:
— Probe: EF3DV3 — SN4047; ConvF(1, 1, 1) @ 2600 MHz; Calibrated: 2019/1/30
— Sensor—Surface: (Fix Surface)
— Electronics: DAE4 Sn854; Calibrated: 2019/5/21
— Phantom: HAC Test Arch with AMCC; Type: SD HAC POI BA;
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E. Scan — measurement distance from the probe sensor center to CD2600 = 10mm & 15mm/Hearing
Aid Compatibility Test at 1 5mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, —6.3 mm
Reference Value = 73.52 V/m; Power Drift = 0.02 dB
PMR not calibrated. PMF = 1.000 is applied.
E—field emissions = 88.59 V/m
Average value of Total=(87.26+88.59) / 2 = 87.925 V/m

                                               PMF scaled E—field

                                                Grid 1 M3 Grid 2 M3 Grid 3 M3
                                                86.22 V/m $7.26 V/m $4.98 V/m
                                                Grid 4 M3 Grid 5 M3 Grid 6 M3
                                                8$0.93 V/m 8$1.50 V/m 79.85 V/m
                                                Grid 7 M3 Grid 8 M3 Grid 9 M3
                                                $7.86 V/m 8$8.59 V/m 8$5.88 V/m
                                                                Cursor:
                                                           Total = 88.59 V/m
                                                            E Category: M3
                                                       Location: 1, 23.5, 9.7 mm




               1.417


               —2.941


               —4.40


               —5.87


               —£.34
                           —
                          0 dB = 8$8.59 V/m = 38.95 dBV/m



Document Created: 2019-07-22 18:08:25
Document Modified: 2019-07-22 18:08:25

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC