RF Test Report-BLE

FCC ID: MSQA006

Test Report

Download: PDF
FCCID_3454709

                                                               FCC Test Report

                       Report No.: RF170428C03-1

                            FCC ID: MSQA006

                       Test Model: ASUS_A006

                 Received Date: Apr. 28, 2017

                         Test Date: May 22, 2017 ~ May 26, 2017

                     Issued Date: Jun. 02, 2017


                         Applicant: ASUSTek COMPUTER INC.

                          Address: 4F, No. 150, LI-TE Rd., PEITOU, TAIPEI 112, TAIWAN



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                                 ( R.O.C )
             Test Location (1): No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan
                                Hsien 333, Taiwan, R.O.C.
             Test Location (2): No.215, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan,
                                R.O.C




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.




Report No.: RF170428C03-1                                                 Page No. 1 / 33                              Report Format Version: 6.1.1


                                                                Table of Contents
Release Control Record .................................................................................................................................. 4
1 Certificate of Conformity ........................................................................................................................... 5
2 Summary of Test Results ........................................................................................................................... 6
    2.1 Measurement Uncertainty ..................................................................................................................... 6
    2.2 Modification Record .............................................................................................................................. 6
3 General Information ................................................................................................................................... 7
    3.1 General Description of EUT .................................................................................................................. 7
    3.2 Description of Test Modes..................................................................................................................... 8
        3.2.1 Test Mode Applicability and Tested Channel Detail .................................................................... 9
    3.3 Description of Support Units ................................................................................................................ 11
        3.3.1 Configuration of System under Test .......................................................................................... 11
    3.4 General Description of Applied Standards ........................................................................................... 11
4 Test Types and ResultsSDR660 .............................................................................................................. 12
    4.1 Radiated Emission and Bandedge Measurement .............................................................................. 12
        4.1.1 Limits of Radiated Emission and Bandedge Measurement ..................................................... 12
        4.1.2 Test Instruments ....................................................................................................................... 13
        4.1.3 Test Procedures ........................................................................................................................ 14
        4.1.4 Deviation from Test Standard ................................................................................................... 14
        4.1.5 Test Set Up ............................................................................................................................... 15
        4.1.6 EUT Operating Conditions ........................................................................................................ 15
        4.1.7 Test Results .............................................................................................................................. 16
    4.2 Conducted Emission Measurement .................................................................................................... 20
        4.2.1 Limits of Conducted Emission Measurement ........................................................................... 20
        4.2.2 Test Instruments ....................................................................................................................... 20
        4.2.3 Test Procedures ........................................................................................................................ 20
        4.2.4 Deviation from Test Standard ................................................................................................... 20
        4.2.5 TEST SETUP............................................................................................................................ 21
        4.2.6 EUT Operating Conditions ........................................................................................................ 21
        4.2.7 Test Results .............................................................................................................................. 22
    4.3 6 dB Bandwidth Measurement ............................................................................................................ 24
        4.3.1 Limits of 6 dB Bandwidth Measurement ................................................................................... 24
        4.3.2 Test Setup ................................................................................................................................. 24
        4.3.3 Test Instruments ....................................................................................................................... 24
        4.3.4 Test Procedure ......................................................................................................................... 24
        4.3.5 Deviation fromTest Standard .................................................................................................... 24
        4.3.6 EUT Operating Conditions ........................................................................................................ 24
        4.3.7 Test Result ................................................................................................................................ 25
    4.4 Conducted Output Power Measurement ............................................................................................ 26
        4.4.1 Limits of Conducted Output Power Measurement.................................................................... 26
        4.4.2 Test Setup ................................................................................................................................. 26
        4.4.3 Test Instruments ....................................................................................................................... 26
        4.4.4 Test Procedures ........................................................................................................................ 26
        4.4.5 Deviation from Test Standard ................................................................................................... 26
        4.4.6 EUT Operating Conditions ........................................................................................................ 26
        4.4.7 Test Results .............................................................................................................................. 26
    4.5 Power Spectral Density Measurement ............................................................................................... 27
        4.5.1 Limits of Power Spectral Density Measurement ....................................................................... 27
        4.5.2 Test Setup ................................................................................................................................. 27
        4.5.3 Test Instruments ....................................................................................................................... 27
        4.5.4 Test Procedure ......................................................................................................................... 27
        4.5.5 Deviation from Test Standard ................................................................................................... 27
        4.5.6 EUT Operating Condition ......................................................................................................... 27
        4.5.7 Test Results .............................................................................................................................. 28

Report No.: RF170428C03-1                                             Page No. 2 / 33                             Report Format Version: 6.1.1


    4.6 Conducted Out of Band Emission Measurement ............................................................................... 29
        4.6.1 Limits of Conducted Out of Band Emission Measurement ....................................................... 29
        4.6.2 Test Setup ................................................................................................................................. 29
        4.6.3 Test Instruments ....................................................................................................................... 29
        4.6.4 Test Procedure ......................................................................................................................... 29
        4.6.5 Deviation from Test Standard ................................................................................................... 29
        4.6.6 EUT Operating Condition ......................................................................................................... 29
        4.6.7 TEST RESULTS ....................................................................................................................... 30
5 Pictures of Test Arrangements................................................................................................................ 32
Appendix – Information on the Testing Laboratories ................................................................................ 33




Report No.: RF170428C03-1                                             Page No. 3 / 33                             Report Format Version: 6.1.1


                                           Release Control Record


 Issue No.              Description                                                Date Issued
 RF170428C03-1          Original Release                                           Jun. 02, 2017




Report No.: RF170428C03-1                        Page No. 4 / 33    Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: ASUS Phone

              Brand: ASUS

        Test Model: ASUS_A006

    Sample Status: Identical Prototype

          Applicant: ASUSTek COMPUTER INC.

          Test Date: May 22, 2017 ~ May 26, 2017

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.247)
                        ANSI C63.10:2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                                ,   Date:    Jun. 02, 2017
                               Ivonne Wu / Supervisor




     Approved by :                                                 ,   Date:    Jun. 02, 2017
                            David Huang / Project Engineer




Report No.: RF170428C03-1                        Page No. 5 / 33               Report Format Version: 6.1.1


                                                                                                                ommert




2      Summary of Test Results

                                 47 CFR FCC Part 15, Subpart C (Section 15.247)

        FCC
                                   Test Item                    Result                     Remarks
       Clause
                                                                             Meet the requirement of limit.
       15.207         AC Power Conducted Emission                Pass        Minimum passing margin is —26.60 dB
                                                                             at 0.69400 MHz.
                                                                             Meet the requirement of limit.
    15.205 & 209              Radiated Emissions                 Pass        Minimum passing margin is —12.11 dB
                                                                             at 2496.80 MHz.
      15.247(d)             Band Edge Measurement                Pass        Meet the requirement of limit.
      15.247(d)              Antenna Port Emission               Pass        Meet the requirement of limit.

    15.247(a)(2)                6 dB Bandwidth                   Pass        Meet the requirement of limit.

      15.247(b)                Conducted power                   Pass        Meet the requirement of limit.

      15.247(e)             Power Spectral Density               Pass        Meet the requirement of limit.

       15.203                Antenna Requirement                 Pass        No antenna connector is used.


2.1      Measurement Uncertainty

Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT:
The listed uncertainties are the worst case uncertainty for the entire range of measurement. Please note that
the uncertainty values are provided for informational purposes only and are not used in determining the
PASS/FAIL results.

                    Messurement                                    F                       Expended Uncertainty
                                                                       requenc
                                                                        quency                      (k=2) (4)
         Conducted Emissions at mains ports                    150 kHz ~ 30 MHz                     244 dB

                                                              30 MHz ~ 200 MHz                     2.0153 dB
            Radiated Emissions up to 1 GHz
                                                             200 MHz ~1000 MHz                     2.0224 dB

                                                                1 GHz ~ 18 GHz                     1.0121 dB
           Radiated Emissions above 1 GHz
                                                               18 GHz ~ 40 GHz                     1.1508 dB


2.2      Modification Record

There were no modifications required for compliance.




Report No.: RF170428C03—1                            Page No. 6 / 33                  Report Format Version: 6.1.1


3      General Information
3.1      General Description of EUT

 Product                         ASUS Phone
 Brand                           ASUS
 Test Model                      ASUS_A006
 Status of EUT                   Identical Prototype
                                 5.0 Vdc (host equipment)
 Power Supply Rating             5.0 Vdc or 9 Vdc (adapter)
                                 3.85 Vdc (Li-ion battery)
 Modulation Type                 GFSK
 Transfer Rate                   1 Mbps
 Operating Frequency             2402 ~ 2480 MHz
 Number of Channel               40
 Output Power                    1.236 mW
 Antenna Type                    PIFA antenna with -2 dBi gain
 Antenna Connector               N/A
 Accessory Device                Refer to Note as below
 Data Cable Supplied             Refer to Note as below
Note:
1. The EUT’s accessories list refers to Ext. Pho.
2. The above EUT information is declared by manufacturer and for more detailed features description,
      please refer to the manufacturer's specifications or User's Manual.




Report No.: RF170428C03-1                              Page No. 7 / 33       Report Format Version: 6.1.1


3.2   Description of Test Modes

40 channels are provided to this EUT:
  Channel      Freq. (MHz)   Channel    Freq. (MHz)    Channel   Freq. (MHz)    Channel       Freq. (MHz)
      0            2402         10         2422           20        2442            30             2462
      1            2404         11         2424           21        2444            31             2464
      2            2406         12         2426           22        2446            32             2466
      3            2408         13         2428           23        2448            33             2468
      4            2410         14         2430           24        2450            34             2470
      5            2412         15         2432           25        2452            35             2472
      6            2414         16         2434           26        2454            36             2474
      7            2416         17         2436           27        2456            37             2476
      8            2418         18         2438           28        2458            38             2478
      9            2420         19         2440           29        2460            39             2480




Report No.: RF170428C03-1                     Page No. 8 / 33              Report Format Version: 6.1.1


3.2.1       Test Mode Applicability and Tested Channel Detail

 EUT Configure                                 Applicable To
                                                                                                         Description
     Mode                RE1G         RE<1G              PLC                  APCM

        -                  √               √                   √                √      -
Where           RE1G: Radiated Emission above 1 GHz                 RE<1G: Radiated Emission below 1 GHz
                PLC: Power Line Conducted Emission                   APCM: Antenna Port Conducted Measurement

Note: The EUT had been pre-tested on the positioned of each 3 axis. The worst case was found when positioned on Y-plane.
Note: “-”means no effect.


Radiated Emission Test (Above 1 GHz):

     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
  EUT Configure
                           Available Channel              Tested Channel               Modulation Type           Data Rate (Mbps)
      Mode
            -                    0 to 39                           0, 19, 39                GFSK                        1



Radiated Emission Test (Below 1 GHz):

     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
  EUT Configure
                           Available Channel              Tested Channel               Modulation Type           Data Rate (Mbps)
      Mode
            -                    0 to 39                              39                    GFSK                        1



Power Line Conducted Emission Test:

     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
  EUT Configure
                           Available Channel              Tested Channel               Modulation Type           Data Rate (Mbps)
      Mode
            -                    0 to 39                              39                    GFSK                        1




Report No.: RF170428C03-1                                           Page No. 9 / 33                 Report Format Version: 6.1.1


Antenna Port Conducted Measurement:

     This item includes all test value of each mode, but only includes spectrum plot of worst value of each
     mode.
     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
  EUT Configure
                     Available Channel              Tested Channel           Modulation Type           Data Rate (Mbps)
      Mode
        -                   0 to 39                    0, 19, 39                    GFSK                       1



Test Condition:
   Applicable To            Environmental Conditions                  Input Power                      Tested by

      RE1G                    25 deg. C, 65 % RH                    120 Vac, 60 Hz                  Charles Hsiao

      RE<1G                    25 deg. C, 65 % RH                    120 Vac, 60 Hz                  Charles Hsiao

       PLC                     25 deg. C, 65 % RH                    120 Vac, 60 Hz                   Getaz Yang

      APCM                     25 deg. C, 65 % RH                      3.85 Vdc                        Anson Lin




Report No.: RF170428C03-1                               Page No. 10 / 33                   Report Format Version: 6.1.1


3.3      Description of Support Units

The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
  No.              Product               Brand              Model No.               Serial No.                     FCC ID
  1.               Earphone            FUNKEY               FK-130102                  N/A                           N/A


 No.                                      Signal Cable Description Of The Above Support Units
 1.     N/A
Note:
1. All power cords of the above support units are non-shielded (1.8m).


3.3.1     Configuration of System under Test




                                                          EUT

                                                 (Power from AC Adapter)
                                                                                Earphone


              *Test Table




3.4      General Description of Applied Standards

The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:


FCC Part 15, Subpart C (15.247)
558074 D01 DTS Meas Guidance v04
ANSI C63.10-2013


All test items have been performed and recorded as per the above standards.


Note: The EUT has been verified to comply with the requirements of FCC Part 15, Subpart B, Class B (DoC).
         The test report has been issued separately.




Report No.: RF170428C03-1                                    Page No. 11 / 33                    Report Format Version: 6.1.1


4     Test Types and Results
4.1     Radiated Emission and Bandedge Measurement
4.1.1    Limits of Radiated Emission and Bandedge Measurement

Radiated emissions which fall in the restricted bands must comply with the radiated emission limits specified
as below table. Other emissions shall be at least 20 dB below the highest level of the desired power:
             Frequencies                          Field Strength               Measurement Distance
                (MHz)                           (microvolts/meter)                   (meters)
             0.009 ~ 0.490                          2400/F (kHz)                           300
             0.490 ~ 1.705                         24000/F (kHz)                            30
             1.705 ~ 30.0                                 30                                30
                30 ~ 88                                  100                                 3
               88 ~ 216                                  150                                 3
              216 ~ 960                                  200                                 3
              Above 960                                  500                                 3
Note:
1.      The lower limit shall apply at the transition frequencies.
2.      Emission level (dBuV/m) = 20 log Emission level (uV/m).
3.      For frequencies above 1000 MHz, the field strength limits are based on average detector, however, the
        peak field strength of any emission shall not exceed the maximum permitted average limits, specified
        above by more than 20 dB under any condition of modulation.




Report No.: RF170428C03-1                            Page No. 12 / 33           Report Format Version: 6.1.1


4.1.2    Test Instruments

        Description &                                                                            Due Date of
                                 Model No.              Serial No.   Date of Calibration
        Manufacturer                                                                             Calibration
Test Receiver
                                  N9038A            MY52260177          Jun. 21, 2016           Jun. 20, 2017
Agilent Technologies
Spectrum Analyzer
                                   FSU43                 101261        Dec. 13, 2016            Dec. 12, 2017
ROHDE & SCHWARZ
BILOG Antenna
                                 VULB9168               9168-472       Dec. 16, 2016            Dec. 15, 2017
SCHWARZBECK
HORN Antenna
                                    3117                00143293       Dec. 29, 2016            Dec. 28, 2017
ETS-Lindgren
HORN Antenna
                                 BBHA 9170              9170-480       Dec. 14, 2016            Dec. 13, 2017
SCHWARZBECK
Fixed Attenuator
                                BW-N10W5+                  NA           Jul. 08, 2016           Jul. 07, 2017
Mini-Circuits
Loop Antenna                      EM-6879                  269         Aug. 11, 2016            Aug. 10, 2017
Preamplifier
                                    310N                 187226         Jun. 24, 2016           Jun. 23, 2017
Agilent
Preamplifier
                                   83017A           MY39501357          Jun. 24, 2016           Jun. 23, 2017
Agilent
Power Meter
                                  ML2495A               1232002        Sep. 08, 2016            Sep. 07, 2017
Anritsu
Power Sensor
                                  MA2411B               1207325        Sep. 08, 2016            Sep. 07, 2017
Anritsu
                                                  Cable-CH1-01(R
RF signal cable                                   FC-SMS-100-SM
                                   5D-FB                                Jun. 24, 2016           Jun. 23, 2017
ETS-LINDGREN                                      S-120+RFC-SMS
                                                   -100-SMS-400)
                                                  Cable-CH1-02(R
RF signal cable
                                   8D-FB          FC-SMS-100-SM         Jun. 24, 2016           Jun. 23, 2017
ETS-LINDGREN
                                                        S-24)
Software                             E3
                                                           NA                NA                       NA
BV ADT                           8.130425b
Antenna Tower
                                     NA                    NA                NA                       NA
MF
Turn Table
                                     NA                    NA                NA                       NA
MF
Antenna Tower &Turn
Table Controller                  MF-7802                  NA                NA                       NA
MF


Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
        2. The test was performed in HsinTien Chamber 1.
        3. The horn antenna and preamplifier (model: 83017A) are used only for the measurement of
           emission frequency above 1GHz if tested.
        4. The FCC Site Registration No. is 149147.
        5. The IC Site Registration No. is IC7450I-1.




Report No.: RF170428C03-1                         Page No. 13 / 33                Report Format Version: 6.1.1


4.1.3   Test Procedures

a.   The EUT was placed on the top of a rotating table 0.8 meters (for below 1 GHz) / 1.5 meters (for above 1
     GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to
     determine the position of the highest radiation.
b.   The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c.   The height of antenna is varied from one meter to four meters above the ground to determine the
     maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
     make the measurement.
d.   For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
     to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to
     find the maximum reading.
e.   The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
     hold mode when the test frequency is below 1 GHz.
f.   The test-receiver system was set to peak and average detected function and specified bandwidth with
     maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
     average limit, measurement with the average detector is unnecessary.


Note:
1.   The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120 kHz & 360 kHz
     for Quasi-peak detection (QP) at frequency below 1 GHz.
2.   The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
     for Peak detection (PK) at frequency above 1 GHz.
3.   The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 1/T for
     Average (Duty cycle < 98 %) detection at frequency above 1 GHz.
4.   The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 10 Hz
     (Duty cycle ≥ 98 %) for Average detection (AV) at frequency above 1 GHz.
5.   All modes of operation were investigated and the worst-case emissions are reported.


4.1.4   Deviation from Test Standard

No deviation.




Report No.: RF170428C03-1                         Page No. 14 / 33               Report Format Version: 6.1.1


4.1.5   Test Set Up


  <Frequency Range below 1 GHz>

                                                               Ant. Tower
                                                                                      1-4m
                                                                                      Variable
                                                 3m
                                                 10m
              EUT&
              Support Units

                                         Turn Table

                  80cm


                                              Ground Plane

                                              Test Receiver




  <Frequency Range above 1 GHz>



                                                            Ant. Tower             1-4m
                                                                                   Variable
            EUT&                              3m
            Support Units

                                    Turn Table
                                                   Absorber

               150cm


                                           Ground Plane
                                           Test Receiver




 For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.1.6   EUT Operating Conditions

a. Placed the EUT on the testing table.
b. Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF170428C03-1                          Page No. 15 / 33                Report Format Version: 6.1.1


                                                                                                                         ommert




4.1.7      Test Results
ABOVE 1 GHz DATA :

EUT Test Condition                                             Measurement Detail
Channel                       Channel 0                        Frequency Range                  1 GHz ~ 25 GHz

Input Power                   120 Vac, 60 Hz                   Detector Function                Peak (PK)
                                                                                                Average (AV)
Environmental
                              25 deg. C, 65 % RH               Tested By                        Charles Hsiao
Conditions


                              Antennal Polarity & Test Distance: Horizontal at 3 m
Frequency Emission        Read         Limit     Margin     Antenna       Cable      Preamp     Ant(Ienna    Table
  (MHz)     Level         Level      (dBuVim)     (aB)       Factor     Loss (dB)     Factor     Height      Angle       Remark
             (dBuV/m)     (dBuV)                             (dB/m)                   (dB)        (cm)      (Degree)

 2361.03       52.48      50.85         74       —21.52       31.76           5.37    35.5        170          354        Peak
 2383.98       41.18      39.49         54       —~12.82      31.78           5.4     35.49       170          354       Average
  2402         92.65      90.92                                31.8           5.4     35.47       170          354       Average
  2402         93.55      91.82                                31.8           5.4     35.47       170          354        Peak
  4804         38.11      30.02         54       —15.89       33.96           8.25    34.12       195          263       Average
  4804         47.55      39.46         74       —26.45       33.96           8.25    34.12       195          263        Peak
                                   Antennal Polarity & Test Distance: Vertical at 3 m

rrequenes| Emso® Pnd uin mage Aient oane TextP BP TE waney
  (MHz)
             (dBuV/m)     (dBuV)
                                     (dBuV/im)    (dB)
                                                             (dB/m)
                                                                        Loss (dB)
                                                                                      (dB)        (cm)      (Degree)

 2342.58       51.82      50.25         74       2218         31.74           5.33    35.5        181          89         Peak
 2386.77       41.46      39.75         54       1254          31.8           5.4     35.49       181          89        Average
  2402         94.78      93.05                                31.8           5.4     35.47       181          89        Average
  2402         95.86      94.13                                31.8           5.4     35.47       181          89         Peak
  4804         39.24      31.15         54       —14.76       33.96           8.25    34.12       195          107       Average
  4804         48.26      40.17         74       —25.74       33.96           8.25    34.12       195          107        Peak

Remarks:
1. Emission Level = Read Level + Antenna Factor + Cable Loss — Preamp Factor
   Margin value = Emission level — Limit value
2. 2402 MHz: Fundamental frequency.




Report No.: RF170428C03—1                                  Page No. 16 / 33                    Report Format Version: 6.1.1


EUT Test Condition                                        Measurement Detail
Channel                     Channel 19                    Frequency Range                1 GHz ~ 25 GHz
                                                                                         Peak (PK)
Input Power                 120 Vac, 60 Hz                Detector Function
                                                                                         Average (AV)
Environmental
                            25 deg. C, 65 % RH            Tested By                      Charles Hsiao
Conditions


                            Antennal Polarity & Test Distance: Horizontal at 3 m
            Emission    Read                            Antenna                Preamp    Antenna       Table
Frequency                           Limit    Margin                  Cable
              Level     Level                            Factor                Factor     Height      Angle      Remark
  (MHz)                           (dBuV/m)    (dB)                 Loss (dB)
            (dBuV/m)   (dBuV)                            (dB/m)                 (dB)       (cm)      (Degree)
 2349.69     51.92      50.35        74      -22.08      31.74       5.33       35.5       170         354         Peak
 2389.38     41.12      39.41        54      -12.88       31.8           5.4   35.49       170         354       Average
   2440      93.63      91.78                            31.85       5.46      35.46       170         354       Average
   2440      94.89      93.04                            31.85       5.46      35.46       170         354         Peak
   2489      52.34      50.33        74      -21.66       31.9       5.53      35.42       170         354         Peak
 2495.84     41.78      39.76        54      -12.22       31.9       5.53      35.41       170         354       Average
                                Antennal Polarity & Test Distance: Vertical at 3 m
            Emission    Read                            Antenna                Preamp    Antenna       Table
Frequency                           Limit    Margin                  Cable
              Level     Level                            Factor                Factor     Height      Angle      Remark
  (MHz)                           (dBuV/m)    (dB)                 Loss (dB)
            (dBuV/m)   (dBuV)                            (dB/m)                 (dB)       (cm)      (Degree)
 2331.96     51.79      50.25        74      -22.21      31.73       5.33      35.52       181          89         Peak
 2389.29     41.12      39.41        54      -12.88       31.8           5.4   35.49       181          89       Average
   2440      95.71      93.86                            31.85       5.46      35.46       181          89       Average
   2440      96.78      94.93                            31.85       5.46      35.46       181          89         Peak
  2492.2     41.75      39.73        54      -12.25       31.9       5.53      35.41       181          89       Average
 2495.84     52.28      50.26        74      -21.72       31.9       5.53      35.41       181          89         Peak

Remarks:
1. Emission Level = Read Level + Antenna Factor + Cable Loss - Preamp Factor
   Margin value = Emission level – Limit value
2. 2440 MHz: Fundamental frequency.




Report No.: RF170428C03-1                             Page No. 17 / 33                  Report Format Version: 6.1.1


EUT Test Condition                                        Measurement Detail
Channel                     Channel 39                    Frequency Range                1 GHz ~ 25 GHz
                                                                                         Peak (PK)
Input Power                 120 Vac, 60 Hz                Detector Function
                                                                                         Average (AV)
Environmental
                            25 deg. C, 65 % RH            Tested By                      Charles Hsiao
Conditions


                               Antennal Polarity & Test Distance: Horizontal at 3 m
            Emission    Read                            Antenna                Preamp    Antenna       Table
Frequency                           Limit    Margin                  Cable
              Level     Level                            Factor                Factor     Height      Angle      Remark
  (MHz)                           (dBuV/m)    (dB)                 Loss (dB)
            (dBuV/m)   (dBuV)                            (dB/m)                 (dB)       (cm)      (Degree)
   2480      92.79      90.83                            31.88           5.5   35.42       170         354       Average
   2480      93.92      91.96                            31.88           5.5   35.42       170         354         Peak
 2493.28     52.03      50.01        74      -21.97       31.9       5.53      35.41       170         354         Peak
  2496.8     41.89      39.87        54      -12.11       31.9       5.53      35.41       170         354       Average
   4960      38.13      29.86        54      -15.87      33.99       8.29      34.01       196         153       Average
   4960      47.57      39.3         74      -26.43      33.99       8.29      34.01       196         153         Peak
                                Antennal Polarity & Test Distance: Vertical at 3 m
            Emission    Read                            Antenna                Preamp    Antenna       Table
Frequency                           Limit    Margin                  Cable
              Level     Level                            Factor                Factor     Height      Angle      Remark
  (MHz)                           (dBuV/m)    (dB)                 Loss (dB)
            (dBuV/m)   (dBuV)                            (dB/m)                 (dB)       (cm)      (Degree)
   2480      94.66      92.7                             31.88           5.5   35.42       181          89       Average
   2480      96.02      94.06                            31.88           5.5   35.42       181          89         Peak
  2497.6     51.58      49.56        74      -22.42       31.9       5.53      35.41       181          89         Peak
  2498.2     41.63      39.61        54      -12.37       31.9       5.53      35.41       181          89       Average
   4960      38.43      30.16        54      -15.57      33.99       8.29      34.01       127         166       Average
   4960      47.84      39.57        74      -26.16      33.99       8.29      34.01       127         166         Peak

Remarks:
1. Emission Level = Read Level + Antenna Factor + Cable Loss - Preamp Factor
   Margin value = Emission level – Limit value
2. 2480 MHz: Fundamental frequency.




Report No.: RF170428C03-1                             Page No. 18 / 33                  Report Format Version: 6.1.1


9 kHz ~ 30 MHz DATA:
The amplitude of spurious emissions attenuated more than 20 dB below the permissible value is not required
to be report.


30 MHz ~ 1 GHz WORST-CASE DATA:
EUT Test Condition                                        Measurement Detail
Channel                     Channel 39                    Frequency Range                30 MHz ~ 1 GHz
                                                                                         Peak (PK)
Input Power                 120 Vac, 60 Hz                Detector Function
                                                                                         Quasi-peak (QP)
Environmental
                            25 deg. C, 65 % RH            Tested By                      Charles Hsiao
Conditions


                               Antennal Polarity & Test Distance: Horizontal at 3 m
            Emission    Read                            Antenna                Preamp    Antenna       Table
Frequency                           Limit    Margin                  Cable
              Level     Level                            Factor                Factor     Height      Angle      Remark
  (MHz)                           (dBuV/m)    (dB)                 Loss (dB)
            (dBuV/m)   (dBuV)                            (dB/m)                 (dB)       (cm)      (Degree)
  81.57       5.78      28.36        40      -34.22       8.47       1.11      32.16       185         124         Peak
  144.75      12.7      33.86       43.5     -30.8        9.73       1.38      32.27       163         234         Peak
  250.59     11.38      28.63        46      -34.62        13        1.85       32.1       148         107         Peak
  428.8      16.34      28.36        46      -29.66      17.75       2.41      32.18       169         134         Peak
  521.2      19.38      28.31        46      -26.62      20.51           2.7   32.14       185         127         Peak
  743.1      22.75      28.46        46      -23.25      23.27       3.16      32.14       142         108         Peak
                                Antennal Polarity & Test Distance: Vertical at 3 m
            Emission    Read                            Antenna                Preamp    Antenna       Table
Frequency                           Limit    Margin                  Cable
              Level     Level                            Factor                Factor     Height      Angle      Remark
  (MHz)                           (dBuV/m)    (dB)                 Loss (dB)
            (dBuV/m)   (dBuV)                            (dB/m)                 (dB)       (cm)      (Degree)
  55.11      23.15      47.21        40      -16.85       7.27           0.9   32.23       177         153         Peak
  143.94      6.81      28.09       43.5     -36.69       9.61       1.38      32.27       196         148         Peak
  234.93      9.71      27.66        46      -36.29      12.36       1.85      32.16       187         113         Peak
  413.4      15.82      27.73        46      -30.18      17.88       2.41       32.2       159         137         Peak
  638.1      21.94      29.07        46      -24.06       22.1       2.93      32.16       195         142         Peak
  822.2      23.84      28.9         46      -22.16       23.5       3.38      31.94       138         109         Peak

Remarks:
1. Emission Level = Read Level + Antenna Factor + Cable Loss - Preamp Factor
   Margin value = Emission level – Limit value




Report No.: RF170428C03-1                             Page No. 19 / 33                  Report Format Version: 6.1.1


4.2      Conducted Emission Measurement
4.2.1     Limits of Conducted Emission Measurement

                                                           Conducted Limit (dBuV)
        Frequency (MHz)
                                            Quasi-peak                                 Average
             0.15 - 0.5                         66 - 56                                 56 - 46
             0.50 - 5.0                           56                                       46
             5.0 - 30.0                           60                                       50


4.2.2     Test Instruments

        Description &                                                  Date Of               Due Date Of
                                Model No.           Serial No.
        Manufacturer                                                  Calibration            Calibration
Test Receiver
                                   ESCI                100613        Nov. 21, 2016          Nov. 20, 2017
ROHDE & SCHWARZ
RF signal cable (with
10dB PAD)                         5D-FB          Cable-cond1-01      Dec. 22, 2016          Dec. 21, 2017
Woken
LISN
ROHDE & SCHWARZ                  ESH3-Z5           835239/001        Mar. 10, 2017           Mar. 09, 2018
(EUT)
LISN
ROHDE & SCHWARZ                  ESH3-Z5               100311        Jul. 28, 2016           Jul. 27, 2017
(Peripheral)
Software                      BV ADT_Cond_
                                                          NA              NA                       NA
ADT                              V7.3.7.3

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
         to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Shielded Room 1.
      3. The VCCI Site Registration No. is C-2040.


4.2.3     Test Procedures

a. The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being connected
      to the power mains through a line impedance stabilization network (LISN). Other support units were
      connected to the power mains through another LISN. The two LISNs provide 50 ohm/50 uH of coupling
      impedance for the measuring instrument.
b. Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
c. The frequency range from 150 kHz to 30 MHz was searched. Emission levels under (Limit – 20 dB) was
      not recorded.


Note: All modes of operation were investigated and the worst-case emissions are reported.


4.2.4     Deviation from Test Standard

No deviation.




Report No.: RF170428C03-1                         Page No. 20 / 33               Report Format Version: 6.1.1


                                                                                                                   ooocc



4.2.5     TEST SETUP
                                Vertical Ground
                                 Reference Plane                                 /Test Receiver




                                 EUT                                              M
                                                                                          5ooo
                                                                                         E___

                                                                                          c   6   o   o




                                               | |       80cm                    | |



                                               L1                                L1
                                                         \               N
                                                                        Ho
                                                                                                          T
                                                                         rizontal
                                                                                       Ground
                                                                        Refere         Plane
                                                                              nce

                       Note: 1.Suppo     units were connect   t s     L
                                    rt                      ed o econd ISN.
                            2.Both of LISNs (AMN) are 80 cm from EUT and at least 80
                              from other units and other metal planes




4.2.6    EUT Operating Conditions

a.   Placed the EUT on the testing table.
b.   Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF170428C03—1                            Page No. 21 / 33                    Report Format Version: 6.1.1


                                                                                                                      ommert
                                                                                                                      [vexiras)]



4.2.7   Test Results
                                                               Detector Function & Quasi—Peak (QP) /
Frequency Range             150kHz ~ 30MHz                     g:iglwultm                Average (AV), 9kHz


Input Power                 120Vac, 60Hz                       Eg‘r’]';‘i’fi”omnima'      25°C, 65%RH
Tested by                   Getaz Yang                         Test Date                 2017/5/23


                                             Phase Of Power : Line (L)
        Frequency      |Correction|   Reading Value          Emission Level                Limit                Margin
 No                         Factor         (dBuV)                (dBuV)                    (dBuV)                (dB)
          (MHz)              (dB)      Q.P.      AV.          QP.       LVA            Q.P.       AV.      QP.         AV.
  1      0.15800            10.35     23.91     10.76        34.26    21.11           65.57     55.57     —31.31     —34.46
  2      0.17801            10.36     22.38     9.34         82.74    19.70           64.58     54.58     —31.84     —34.88
  3      0.51000            10.40      6.45     —2.26        16.85     8.14           56.00     46.00     —39.15     —37.86
  4      0.69400            10.40     19.00     7.91         2940     18.31           56.00     46.00     —26.60     —27.69
  5      9.04600            10.79      6.68     —1.30        17.47     9.49           60.00     50.00     —42.53     —40.51
  6      12.59000           10.96      243      —8.24        13.39     7.72           60.00     50.00     —46.61     —42.28
Remarks:
          1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
         2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value
                            #f8
                              &
                              8
                              d
                              8
                              60B
                              8
                              B
                              s
                              a9




                                                  1ho                                        sale
                              &




                                                                                              mie




Report No.: RF170428C03—1                               Page No. 22 / 33                    Report Format Version: 6.1.1


                                                                                                                          ommert
                                                                                                                          [vexiras)]



                                                             Detectolr Function & Quasi—Peak (QP) /
Frequency Range             150kHz ~ 30MHz                   g:iglwultm                    Average (AV), OkHz


Input Power                 120Vac, 60Hz                     Eg‘r’]'é‘i’fi”omnima'          25°C, 65%RH
Tested by                   Getaz Yang                       Test Date                     2017/5/23


                                           Phase Of Power : Neutral (N)
        Frequency      |Correction|   Reading Value        Emission Level                     Limit                 Margin
 No                         Factor         (dBuV)               (dBuV)                      (dBuV)                   (dB)
           (MHz)             (dB)      a.P.      AV.        Q.P.      AV.               Q.P.       AV.         Q.P.        AV.
  1       0.19400           10.14     15.59     3.74       25.73     13.88             63.86     53.86        —38.13     —39.98
  2       0.68200           10.16     21.95     13.52      32.11     23.68             56.00     46.00        —23.89     —22.32
  3       1.22138           10.18     15.01     5.39       25.19     15.57             56.00     46.00        —30.81     —30.43
  4       1.75800           10.22     13.64     5.27       23.86     1549              56.00     46.00        —32.14     —30.51
  5       4.37400           10.35     12.63     5.19       22.98     15.54             56.00     46.00        —33.02     —30.46
  6       8.07400           10.48     13.73     8.05       24.21     18.53             60.00     50.00        —35.79     —31.47
Remarks:
          1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
         2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value


                                                                                    io Trace _
                                                                                    ar timit |.=—
                                                                                    Cay Limit |.o—




Report No.: RF170428C03—1                             Page No. 23 / 33                          Report Format Version: 6.1.1


4.3     6 dB Bandwidth Measurement
4.3.1    Limits of 6 dB Bandwidth Measurement

The minimum of 6 dB Bandwidth Measurement is 0.5 MHz.


4.3.2    Test Setup



                EUT                                              SPECTRUM
                                                                 ANALYZER
                                       10 dB ATTENUATION
                                       PAD

4.3.3    Test Instruments

Refer to section 4.1.2 to get information of above instrument.


4.3.4    Test Procedure

a.    Set resolution bandwidth (RBW) = 100 kHz
b.    Set the video bandwidth (VBW) ≥ 3 x RBW, Detector = Peak.
c.    Trace mode = max hold.
d.    Sweep = auto couple.
e.    Measure the maximum width of the emission that is constrained by the frequencies associated with the
      two amplitude points (upper and lower) that are attenuated by 6 dB relative to the maximum level
      measured in the fundamental emission


4.3.5    Deviation fromTest Standard

No deviation.


4.3.6    EUT Operating Conditions

The software provided by client to enable the EUT under transmission condition continuously at lowest,
middle and highest channel frequencies individually.




Report No.: RF170428C03-1                         Page No. 24 / 33           Report Format Version: 6.1.1


4.3.7    Test Result

                                              6 dB Bandwidth        Minimum Limit
        Channel             Frequency (MHz)                                                   Pass / Fail
                                                   (MHz)                (MHz)
           0                     2402                0.70                0.5                      Pass
          19                     2440                0.70                0.5                      Pass
          39                     2480                0.70                0.5                      Pass

                                        Spectrum Plot of Worst Value




Report No.: RF170428C03-1                        Page No. 25 / 33              Report Format Version: 6.1.1


4.4     Conducted Output Power Measurement
4.4.1        Limits of Conducted Output Power Measurement

For systems using digital modulation in the 2400–2483.5 MHz bands: 1 Watt (30 dBm)


4.4.2        Test Setup




               EUT                                  Power Sensor                    Power Meter
                                   ATTENUATION
                                   PAD




4.4.3        Test Instruments

Refer to section 4.1.2 to get information of above instrument.


4.4.4        Test Procedures

A peak / average power sensor was used on the output port of the EUT. A power meter was used to read the
response of the peak / average power sensor. Record the power level.


4.4.5        Deviation from Test Standard

No deviation.


4.4.6        EUT Operating Conditions

The software provided by client to enable the EUT under transmission condition continuously at lowest,
middle and highest channel frequencies individually.


4.4.7        Test Results

                      Frequency             Peak Power               Peak Power        Limit
  Channel                                                                                               Pass / Fail
                        (MHz)                  (mW)                    (dBm)          (dBm)
        0                   2402                 0.9795                  -0.09           30                Pass
        19                  2440                 1.236                       0.92        30                Pass
        39                  2480                 1.119                       0.49        30                Pass




Report No.: RF170428C03-1                                 Page No. 26 / 33           Report Format Version: 6.1.1


4.5     Power Spectral Density Measurement
4.5.1     Limits of Power Spectral Density Measurement

The Maximum of Power Spectral Density Measurement is 8 dBm.


4.5.2     Test Setup



                EUT                                              SPECTRUM
                                         10dB ATTENUATION        ANALYZER
                                         PAD



4.5.3     Test Instruments

Refer to section 4.1.2 to get information of above instrument.


4.5.4     Test Procedure

a. Set the RBW = 3 kHz, VBW =10 kHz, Detector = peak.
b. Sweep time = auto couple, Trace mode = max hold, allow trace to fully stabilize.
c. Use the peak marker function to determine the maximum power level in any 100 kHz band segment within
      the fundamental EBW.


4.5.5     Deviation from Test Standard

No deviation.


4.5.6     EUT Operating Condition

The software provided by client to enable the EUT under transmission condition continuously at lowest,
middle and highest channel frequencies individually.




Report No.: RF170428C03-1                         Page No. 27 / 33             Report Format Version: 6.1.1


4.5.7     Test Results

                            Frequency            PSD                   Limit
        Channel                                                                            Pass / Fail
                              (MHz)           (dBm/3 kHz)           (dBm/3 kHz)
           0                  2402               -14.82                 8                      Pass
          19                  2440               -13.63                 8                      Pass
          39                  2480               -14.15                 8                      Pass


                                        Spectrum Plot of Worst Value




Report No.: RF170428C03-1                        Page No. 28 / 33             Report Format Version: 6.1.1


4.6     Conducted Out of Band Emission Measurement
4.6.1    Limits of Conducted Out of Band Emission Measurement

Below –20 dB of the highest emission level of operating band (in 100 kHz Resolution Bandwidth).


4.6.2    Test Setup



                 EUT                                             SPECTRUM
                                        10dB ATTENUATION         ANALYZER
                                        PAD



4.6.3    Test Instruments

Refer to section 4.1.2 to get information of above instrument.


4.6.4    Test Procedure

MEASUREMENT PROCEDURE REF
1.    Set the RBW = 100 kHz.
2.    Set the VBW ≥ 300 kHz.
3.    Detector = peak.
4.    Sweep time = auto couple.
5.    Trace mode = max hold.
6.    Allow trace to fully stabilize.
7.    Use the peak marker function to determine the maximum power level in any 100 kHz band segment
      within the fundamental EBW.


MEASUREMENT PROCEDURE OOBE
1.    Set RBW = 100 kHz.
2.    Set VBW ≥ 300 kHz.
3.    Detector = peak.
4.    Sweep = auto couple.
5.    Trace Mode = max hold.
6.    Allow trace to fully stabilize.
7.    Use the peak marker function to determine the maximum amplitude level.


4.6.5    Deviation from Test Standard

No deviation.


4.6.6    EUT Operating Condition

The software provided by client to enable the EUT under transmission condition continuously at lowest,
middle and highest channel frequencies individually.




Report No.: RF170428C03-1                         Page No. 29 / 33             Report Format Version: 6.1.1


4.6.7   TEST RESULTS
                               Ch 0




                              Ch 19




                              Ch 39




Report No.: RF170428C03-1   Page No. 30 / 33   Report Format Version: 6.1.1


                    Ch 0 Band Edge                      Ch 39 Band Edge




Report No.: RF170428C03-1            Page No. 31 / 33        Report Format Version: 6.1.1


5    Pictures of Test Arrangements

Please refer to the attached file (Test Setup Photo).




Report No.: RF170428C03-1                         Page No. 32 / 33   Report Format Version: 6.1.1


Appendix – Information on the Testing Laboratories


We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are accredited and
approved according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Linko EMC/RF Lab                                      Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                   Tel: 886-3-6668565
Fax: 886-2-26051924                                   Fax: 886-3-6668323


Hwa Ya EMC/RF/Safety
Tel: 886-3-3183232
Fax: 886-3-3270892


Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF170428C03-1                        Page No. 33 / 33             Report Format Version: 6.1.1



Document Created: 2017-06-05 15:45:34
Document Modified: 2017-06-05 15:45:34

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC