Z272S- TestRpt_142kHz_20180822

FCC ID: MSQ-Z272S

Test Report

Download: PDF
FCCID_3974047

Report No.:1860370R-RFUSP20V00




                                         FCC Test Report


                       Product Name ASUS All-in-One PC/Zen AiO
                       Model No.               Z272S,Z272SDK,Z272SDT,Z272SD
                       FCC ID.                 MSQ-Z272S




                    Applicant ASUSTeK COMPUTER INC.
                    Address           4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan




                                  Date of Receipt          Apr. 11, 2018

                                  Issued Date              Aug. 02, 2018

                                  Report No.               1860370R-RFUSP20V00

                                  Report Version           V1.0




 The test results relate only to the samples tested.
 The test results shown in the test report are traceable to the national/international standard through the calibration report of
 the equipment and evaluated measurement uncertainty herein.
 This report must not be used to claim product endorsement by TAF or any agency of the government.
 The test report shall not be reproduced without the written approval of DEKRA Testing and Certification Co., Ltd.




                                                      Page : 1 of 19


Report No.:1860370R-RFUSP20V00



                                         Test Rep o r t
                                                                    Issued Date: Aug. 02, 2018
                                                                    Report No.: 1860370R-RFUSP20V00




     Product Name                ASUS All-in-One PC/Zen AiO

     Applicant                   ASUSTeK COMPUTER INC.

     Address                     4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan

     Manufacturer                ASUSTeK COMPUTER INC.

     Model No.                   Z272S,Z272SDK,Z272SDT,Z272SD

     FCC ID.                     MSQ-Z272S

     EUT Rated Voltage           AC 100-240V, 50-60Hz

     EUT Test Voltage            AC 120V/60Hz

     Trade Name                  ASUS

     Applicable Standard         FCC CFR Title 47 Part 15 Subpart C: 2017

                                 ANSI C63.4: 2014, ANSI C63.10: 2013

     Test Result                 Complied




     Documented By         :


                                            ( Adm. Assistant / Vita Wang )

     Tested By             :



                                               ( Engineer / Anson lu )

     Approved By           :

                                              ( Director / Vincent Lin )




                                              Page : 2 of 19


Report No.:1860370R-RFUSP20V00



                                             TAB L E O F C O N T E N T S
        Description                                                                                                                     Page
1.                 GENERAL INFORMATION ................................................................................................ 4

 1.1.      EUT Description ................................................................................................................... 4
 1.2.      Operational Description ......................................................................................................... 5
 1.3.      Test System Details ............................................................................................................... 6
 1.4.      Configuration of Test System ................................................................................................ 7
 1.5.      EUT Exercise Software ......................................................................................................... 7
 1.6.      Test Facility ........................................................................................................................... 8
 1.7.      List of Test Equipment........................................................................................................... 9
2.                 Conducted Emission ............................................................................................................ 10

 2.1.      Test Setup............................................................................................................................ 10
 2.2.      Limits .................................................................................................................................. 10
 2.3.      Test Procedure ..................................................................................................................... 10
 2.4.      Uncertainty.......................................................................................................................... 10
 2.5.      Test Result of Conducted Emission...................................................................................... 11
3.                 Radiated Emission ............................................................................................................... 13

 3.1.      Test Setup............................................................................................................................ 13
 3.2.      Limits .................................................................................................................................. 14
 3.3.      Test Procedure ..................................................................................................................... 15
 3.4.      Uncertainty.......................................................................................................................... 15
 3.5.      Test Result of Radiated Emission......................................................................................... 16
4.                 EMI Reduction Method During Compliance Testing ......................................................... 19

Attachment 1: EUT Test Photographs
Attachment 2: EUT Detailed Photographs




                                                              Page : 3 of 19


Report No.: 1860370R—RFUSP20V00                                                         5> DEKRA
1.          GENERAL INFORMATION

1.1.        EUT Description

         Product Name            ASUS All—in—One PC/Zen AiO

         Trade Name              ASUS

         Model No.               72728,£2728DK,7£2728D1,727285D

         FCC ID.                 MSQ—Z2725

         Frequency Range         110—145kHz

         Type of Modulation      |ASK Modulation

         Type of antenna         Coil Antenna
         Power Adapter           MFR: ASUS, M/N: ADP—180MB—F
                                 Input: AC 100—240V~ 50—60Hz 2.34A
                                 Output: DC 19.5V, 9.23A
                                 Cable Out: Non—shielded, 1.50m




        Frequency of Channel:
           Channel         Frequency
            Channel 1:        142KHz



Note:
1.     The EUT is an ASUS All—in—One PC/Zen AiO with a built—in 110—145kHz transceiver.
2.      The EUT is including four models for different marketing requirement.
3.     These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance
       with Part 15 Subpart C Paragraph 15.209
4.     Only the higher Fundamental Radiated Emission channel was tested and recorded in this report.


        Test Mode              Mode 1: Transmit




                                                  Page : 4 of 19


Report No.:1860370R-RFUSP20V00


1.3.       Test System Details

           The types for all equipment, plus descriptions of all cables used in the tested system (including
           inserted cards) are:


Product                     Manufacturer         Model No.           Serial No.            Power Cord
1      LCD Monitor          ASUS                 VS229HA             F4LMQS135395          Non-Shielded, 1.8m
2      USB 3.0(1T)          Transcend            TS1TSJ25M3          C13890-3746           Non-Shielded, 0.4m
3      Mouse                COMPAQ               M-S69               44J5                  Non-Shielded, 1.8m
4      Keyboard             DELL                 SK-8115             MY-0DJ325-71619-
                                                                                           Non-Shielded, 1.8m
                                                                     79D-0178
5      USB 3.0(1T)          Transcend            TS1TSJ25M3          C13890-3746           Non-Shielded, 0.4m
6      USB 3.0(1T)          Transcend            TS1TSJ25M3          C13890-3746           Non-Shielded, 0.4m
7      Microphone &         Ergotech             ET-E201             N/A
                                                                                           Non-Shielded, 1.65m
       Earphone
8      DVD PLAYER           Pioneer              DV-600AV            GJKD006378LS          Non-Shielded, 1.8m
9      Test Fixture         N/A                  N/A                 N/A                   N/A


Signal Cable Type                                Signal cable Description
A      HDMI Cable                                Non-shielded, 1.80m
B      USB Cable                                 Non-shielded, 0.40m
C      USB Cable                                 Non-shielded, 1.80m
D      USB Cable                                 Non-shielded, 0.40m
E      USB Cable                                 Non-shielded, 0.40m
F      USB Cable                                 Non-shielded, 0.40m
G      Signal Cable                              Non-shielded, 1.65m
H      HDMI Cable                                Non-shielded, 1.80m
I      Network Cable                             Non-shielded, 1.65m




                                                  Page : 6 of 19


Report No.:1860370R-RFUSP20V00

1.4.         Configuration of Test System




1.5.         EUT Exercise Software

       (1)     Setup the EUT as shown in Section 1.4
       (2)     Turn on the power of all equipment.
       (3)     Start the continuous transmitter.
       (4)     Verify that the EUT works properly.




                                                   Page : 7 of 19


Report No.:1860370R-RFUSP20V00




1.6.    Test Facility

        Ambient conditions in the laboratory:
                   Items                  Required (IEC 68-1)                   Actual
        Temperature (C)             15-35                          20-35
        Humidity (%RH)               25-75                          50-65
        Barometric pressure (mbar) 860-1060                         950-1000


       The related certificate for our laboratories about the test site and management system can be downloaded from
       DEKRA Testing and Certification Co., Ltd. Web Site:
       http://www.dekra.com.tw/english/about/certificates.aspx?bval=5
       The address and introduction of DEKRA Testing and Certification Co., Ltd. laboratories can be founded in our
       Web site: http://www.dekra.com.tw/index_en



        Site Description:    Accredited by TAF
                             Accredited Number: 3023


        Site Name:           DEKRA Testing and Certification Co., Ltd.
        Site Address:        No.5-22, Ruishukeng, Linkou Dist., New Taipei City 24451,
                             Taiwan, R.O.C..
                             TEL: 886-2-8601-3788 / FAX : 886-2-8601-3788
                             E-Mail : info.tw@dekra.com


        FCC Accreditation Number: TW3023




                                                 Page : 8 of 19


    Report No.:1860370R-RFUSP20V00




    1.7.       List of Test Equipment

For Conducted measurements /CB3/SR8
     Equipment                     Manufacturer          Model No.         Serial No.         Cali. Date   Due. Date
     Temperature Chamber           WIT GROUP             TH-1S-B           EQ-201-00146 2018/02/12         2019/02/11
X    Spectrum Analyzer             Agilent               N9010A            MY48030495 2017/10/13           2018/10/12
     Peak Power Analyzer           Keysight              8990B             MY51000410 2018/08/01           2019/07/31
     Wideband Power Sensor         Keysight              N1923A            MY56080003 2018/07/25           2019/07/24
     Wideband Power Sensor         Keysight              N1923A            MY56080004 2018/07/25           2019/07/24
X    EMI Test Receiver             R&S                   ESCS 30           100369             2017/11/07   2018/11/06
X    LISN                          R&S                   ESH3-Z5           836679/017         2018/02/09   2019/02/08
X    LISN                          R&S                   ENV216            100097             2018/02/09   2019/02/08
X    Coaxial Cable                 DEKRA                 RG 400            LC018-RG           2018/06/21   2019/06/20
For Radiated measurements /Site3/CB8
     Equipment                     Manufacturer          Model No.         Serial No.         Cali. Date   Due. Date
X    Spectrum Analyzer             R&S                   FSP40             100170             2018/03/12   2019/03/11
X    Loop Antenna                  Teseq                 HLA6121           37133              2017/10/13   2018/10/12
X    Bilog Antenna                 Schaffner Chase       CBL6112B          2707               2018/06/24   2019/06/23
X    Coaxial Cable                 DEKRA                 RG 214            LC003-RG           2018/06/14   2019/06/13
                                                                           170101000330
X    Pre-Amplifier                 Jet-Power             JPA-10M1G33                          2018/06/14   2019/06/13
                                                                           010
     Horn Antenna                  ETS-Lindgren          3117              00135205           2018/05/03   2019/05/02
     Horn Antenna                  SCHWARZBECK           9120D             576                2017/12/07   2018/12/06

     Pre-Amplifier                 EMCI                  EMC012630SE 980210                   2018/04/10   2019/04/09

     Horn Antenna                  Com-Power             AH-840            101043             2018/01/09   2019/01/08
     Amplifier + Cable             EMCI                  EMC184045SE 980370                   2018/03/21   2019/03/20
     Filter                        MicroTRON             BRM50701          019                2017/11/21   2018/11/20
     Filter                        Microwave Circuits N0257881             36681              2018/01/22   2019/01/21
Note:
   1.      All equipments are calibrated every one year.
   2.      The test instruments marked with “X” are used to measure the final test results.
   3.      Test Software version :QuieTek EMI 2.0 V2.1.113.




                                                     Page : 9 of 19


Report No.: 1860370R—RFUSP20V00                                                                             > D E K RA




2.      Conducted Emission


2.1.    Test Setup


                                                                               Rm_fla.u\g

                          Test Receiver                                                                       /
                                                                                                     40cm     /
                                                                                        4                    D/



                                                                                                              /
                                                                                                              /
                                                                                                              /

                                  [|mw____           usn 0                                   L@SN             7/
            1414141414111]414{     144                                                           A
                                                                                 LISN
                                            Ground Plane



2.2.    Limits

                            FCC Part 15 Subpart C Paragraph 15.207 (dBuV) Limit

                             Frequency                                       Limits

                                  MHz                             QP                        AV
                             0.15 — 0.50                       66—56(6»                 56—46(@»
                                 0.50—5.0                          56                       46
                                 5.0 — 30                          60                       50


2.3.    Test Procedure

        The EUT and simulators are connected to the main power through a line impedance stabilization
        network (L.LS.N.). This provides a 50 ohm /50uH coupling impedance for the measuring
        equipment. The peripheral devices are also connected to the main power through a LISN that
        provides a 50ohm /50uH coupling impedance with 50ohm termination. (Please refers to the block
        diagram of the test setup and photographs.)
        Both sides of A.C. line are checked for maximum conducted interference. In order to find the
        maximum emission, the relative positions of equipment and all of the interface cables must be
        changed according to ANSI C€63.4: 2014 on conducted measurement.
        Conducted emissions were invested over the frequency range from 0.1 5MHz to 30MHz using a
        receiver bandwidth of IkHz.


2.4.    Uncertainty

        + 2.26 dB


                                                           Page : 10 of 19


Report No.:1860370R-RFUSP20V00




2.5.      Test Result of Conducted Emission

          Product      :       ASUS All-in-One PC/Zen AiO
          Test Item    :       Conducted Emission Test
          Power Line   :       Line 1
          Test Mode    :       Mode 1: Transmit
          Test Date    :       2018/04/13


   Frequency           Correct            Reading         Measurement    Margin    Limit
                           Factor          Level                Level
        MHz                 dB             dBuV                 dBuV       dB      dBuV
       LINE 1
   Quasi-Peak
        0.220              9.673           34.380               44.053   -19.947   64.000
        0.341              9.681           36.400               46.081   -14.462   60.543
        0.400              9.685           32.900               42.585   -16.272   58.857
        0.576              9.696           32.640               42.336   -13.664   56.000
        0.775              9.719           29.100               38.819   -17.181   56.000
        3.517              9.860           29.970               39.829   -16.171   56.000


       Average
        0.220              9.673           26.280               35.953   -18.047   54.000
        0.341              9.681           26.020               35.701   -14.842   50.543
        0.400              9.685           17.090               26.775   -22.082   48.857
        0.576              9.696           21.110               30.806   -15.194   46.000
        0.775              9.719           18.650               28.369   -17.631   46.000
        3.517              9.860           14.230               24.089   -21.911   46.000


Note:
       1. All Reading Levels are Quasi-Peak and average value.
       2. " " means the worst emission level.
       3. Measurement Level = Reading Level + Correct Factor




                                              Page : 11 of 19


Report No.:1860370R-RFUSP20V00




        Product      :       ASUS All-in-One PC/Zen AiO
        Test Item    :       Conducted Emission Test
        Power Line   :       Line 2
        Test Mode    :       Mode 1: Transmit
        Test Date    :       2018/04/13


   Frequency         Correct            Reading         Measurement    Margin    Limit
                         Factor          Level                Level
     MHz                  dB             dBuV                 dBuV       dB      dBuV
    LINE 2
  Quasi-Peak
     0.205               9.672           27.690               37.362   -27.067   64.429
     0.232               9.674           31.000               40.674   -22.983   63.657
     0.341               9.671           31.430               41.101   -19.442   60.543
     0.892               9.716           28.250               37.966   -18.034   56.000
     1.697               9.777           29.000               38.777   -17.223   56.000
     3.502               9.849           29.440               39.289   -16.711   56.000


    Average
     0.205               9.672           13.820               23.492   -30.937   54.429
     0.232               9.674           20.440               30.114   -23.543   53.657
     0.341               9.671           21.350               31.021   -19.522   50.543
     0.892               9.716           20.050               29.766   -16.234   46.000
     1.697               9.777           15.690               25.467   -20.533   46.000
     3.502               9.849           12.340               22.189   -23.811   46.000


Note:
    1. All Reading Levels are Quasi-Peak and average value.
    2. " " means the worst emission level.
    3. Measurement Level = Reading Level + Correct Factor




                                            Page : 12 of 19


Report No.:1860370R-RFUSP20V00




3.      Radiated Emission

3.1.    Test Setup

 Under 30MHz Test Setup
                                                              3m


                   FRP Dome



                                                         Antenna Mast
                                                         Broadband or Loop
                                                         Antenna
                                                         Antenna height can be
                                                         moved from 1m to 4m.                               1
           Non-Conducted Table
                                   EUT                                                                      m
                                                                                                            or
                                          80cm                                                              10
                                                                                                            m
                                                   Fully soldered Metal Ground
               Test                                                                           To Receiver
             Receiver




 Radiated Emission Below 1GHz

                                                                3m


                        FRP Dome
                                                                                                      1m to 4m




                                                                     The height of broad
                                                                     band antenna was
                                                                     scanned from 1m to 4m.
                                                                     The distance between

                                    EUT                              antenna and turn table
             Non-Conducted Table                                     was 3m..

                                            80cm


                                                     Fully soldered Metal Ground              To Controller
                 Test                                                                             To Receiver
               Receiver




                                            Page : 13 of 19


Report No.:1860370R-RFUSP20V00




3.2.    Limits

                                  FCC Part 15 Subpart B Paragraph 15.209 Limits
                 Frequency                     Field Strength          Measurement Distance
                 (MHz)                         (microvolts/meter)      (meters)
                 0.009 - 0.490                 2,400/F(kHz)            300
                 0.490– 1.705                  24,000/F(kHz)           30
                 1.705 – 30                    30                      30
                 30 – 88                       100                     3
                 88 - 216                      150                     3
                 216 - 960                     200                     3
                 Above 960                     500                     3


        Remarks : 1. RF Voltage (dBuV) = 20 log RF Voltage (uV)
                    2. In the Above Table, the tighter limit applies at the band edges.
                    3. Distance refers to the distance in meters between the measuring instrument
                    antenna and the closed point of any part of the device or system.




                                             Page : 14 of 19


Report No.: 1860370R—RFUSP20V00                                                        > D E K RA




3.3.    Test Procedure

         The EUT was setup according to ANSI C63.10, 2013 and tested compliance to FCC 47CFR 15.209
         requirements.
        The EUT and its simulators are placed on a turn table which is 0.8 meter above ground. The turn
        table can rotate 360 degrees to determine the position of the maximum emission level. The EUT
        was positioned such that the distance from antenna to the EUT was 3 meters.
        The antenna can move up and down between 1 meter and 4 meters to find out the maximum
        emission level.
        Both horizontal and vertical polarization of the antenna are set on measurement. In order to find
        the maximum emission, all of the interface cables must be manipulated according to ANSI
        €63.10: 2013 on radiated measurement.
        The resolution bandwidth below 1GHz setting on the field strength meter is 120 kHz and above 1GHz
        is 1 MHz. Radiated emission measurements below 1GHz are made using broadband Bilog antenna
        and above 1GHz are made using Horn Antennas.
         The measurement is divided into the Preliminary Measurement and the Final Measurement.
         The suspected frequencies are searched for in Preliminary Measurement with the measurement
        antenna kept pointed at the source of the emission both in azimuth and elevation, with the polarization
        of the antenna oriented for maximum response. The antenna is pointed at an angle towards the source
        of the emission, and the EUT is rotated in both height and polarization to maximize the measured
        emission. The emission is kept within the illumination area of the 3 dB bandwidth of the antenna.
         The worst radiated emission is measured on the Final Measurement.

        The measurement frequency range form 9kHz — 10th Harmonic of fundamental was investigated.



3.4.    Uncertainty

             4.08 dB above 1GHz
        I+




        T 4.22 dB below 1GHz
        +




                                              Page : 15 of 19


Report No.:1860370R-RFUSP20V00




3.5.       Test Result of Radiated Emission

           Product     :       ASUS All-in-One PC/Zen AiO
           Test Item   :       Fundamental Radiated Emission
           Test Site   :       No.3 OATS
           Test date   :       2018/04/11
           Test Mode   :       Mode 1: Transmit


   Frequency           Correct             Reading         Measurement    Margin       Limit
                           Factor           Level                 Level
        MHz                 dB              dBuV                 dBuV/m     dB        dBuV/m
   Horizontal
        0.142              19.726          56.900                76.626   -27.932     104.558
       Vertical
        0.142              19.726          43.100                62.826   -41.732     104.558




Note:
     1. Limit=24.558 dBuV/300m + 40*Log (300(m)/3(m))= 104.558dBuV/3m (Quasi-Peak).
     2. All Readings below 1GHz are Quasi-Peak, above are average value.
     3. Measurement Level = Reading Level + Correct Factor.




                                               Page : 16 of 19


Report No.:1860370R-RFUSP20V00



             Product      :       ASUS All-in-One PC/Zen AiO
             Test Item    :       Fundamental Radiated Emission
             Test Site    :       No.3 OATS
             Test date    :       2018/07/28
             Test Mode    :       Mode 1: Transmit (9k-30M)


9kHz~30MHz
   Frequency              Correct             Reading         Measurement         Margin             Limit
                              Factor           Level                 Level
        MHz                    dB              dBuV                 dBuV/m          dB              dBuV/m
  Quasi-Peak
   Horizontal
        0.284             19.690              34.500                54.190        -54.480           108.670
        0.426             19.680              32.200                51.880        -46.540            98.420
        0.568             19.680              25.400                45.080        -28.025            73.105
        0.710             19.680              21.200                40.880        -30.959            71.839
        0.852             19.680              19.500                39.180        -31.393            70.573
        0.994             19.670              20.900                40.570        -28.738            69.308
        1.136             19.680              15.200                34.880        -33.162            68.042
        1.278             19.680              11.200                30.880        -35.896            66.776
        1.420             19.690               7.700                27.390        -38.120            65.510


    Vertical
        0.284             19.690              21.100                40.790        -67.880           108.670
        0.426             19.680              21.100                40.780        -57.640            98.420
        0.568             19.680              16.200                35.880        -37.225            73.105
        0.710             19.680              14.700                34.380        -37.459            71.839
        0.852             19.680               9.100                28.780        -41.793            70.573
        0.994             19.670              13.800                33.470        -35.838            69.308
        1.136             19.680               8.600                28.280        -39.762            68.042
        1.278             19.680               8.500                28.180        -38.596            66.776
        1.420             19.690               6.700                26.390        -39.120            65.510
Note:

        1.   All Readings below 1GHz are Quasi-Peak.
        2.   Measurement Level = Reading Level + Correct Factor.
        3.   “    ” means the worst emission level.
        4.   The average measurement was not performed when the peak measured data under the limit of
             average detection. If the readings given are average, peak measurement should also be supplied.

                                                  Page : 17 of 19


Report No.:1860370R-RFUSP20V00


             Product      :       ASUS All-in-One PC/Zen AiO
             Test Item    :       Fundamental Radiated Emission
             Test Site    :       No.3 OATS
             Test date    :       2018/04/11
             Test Mode    :       Mode 1: Transmit (30M-1G)


9kHz~30MHz
   Frequency              Correct             Reading         Measurement         Margin             Limit
                              Factor           Level                 Level
        MHz                    dB              dBuV                 dBuV/m          dB              dBuV/m
  Quasi-Peak
   Horizontal
        97.900            16.812              16.017                32.829        -10.671            43.500
    227.880               13.351              21.520                34.871        -11.129            46.000
    454.860               22.021              15.640                37.661        -8.339             46.000
    530.520               23.734              17.664                41.398        -4.602             46.000
    741.980               26.199              11.201                37.400        -8.600             46.000
    910.760               26.920              11.634                38.554        -7.446             46.000


    Vertical
        95.960            16.554              19.883                36.437        -7.063             43.500
    227.880               20.321              16.513                36.834        -9.166             46.000
    350.100               17.364              23.046                40.410        -5.590             46.000
    530.520               21.844              20.265                42.109        -3.891             46.000
    741.980               24.429              15.897                40.326        -5.674             46.000
    910.760               28.020               9.906                37.926        -8.074             46.000


Note:

        5.   All Readings below 1GHz are Quasi-Peak.
        6.   Measurement Level = Reading Level + Correct Factor.
        7.   “    ” means the worst emission level.
        8.   The average measurement was not performed when the peak measured data under the limit of
             average detection. If the readings given are average, peak measurement should also be supplied.




                                                  Page : 18 of 19


Report No.:1860370R-RFUSP20V00




4.      EMI Reduction Method During Compliance Testing



        No modification was made during testing.




                                           Page : 19 of 19



Document Created: 2018-08-22 09:20:06
Document Modified: 2018-08-22 09:20:06

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC