RF Exposure Info (MPE)_rev.pdf

FCC ID: MSQ-RPACRR00

RF Exposure Info

Download: PDF
FCCID_3801813

                                                           RF Exposure Report

                       Report No.: SA170224C10B

                             FCC ID: MSQ-RPACRR00

                       Test Model: RP-AC55

                   Series Model: RP-AC1200

                 Received Date: Dec. 13, 2017

                         Test Date: Jan. 09 ~ Mar. 06, 2018

                     Issued Date: Mar. 07, 2018



                         Applicant: ASUSTeK COMPUTER INC.

                          Address: 4F, NO. 150,Li-Te Rd. Peitou,Taipei 112, Taiwan



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.


Report No.: SA170224C10B                                             Page No. 1 / 6                                             Report Format Version: 6.1.1
Reference No.: 171213C06


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
3         Calculation Result of Maximum Conducted Power........................................................................... 6




Report No.: SA170224C10B                                             Page No. 2 / 6                                              Report Format Version: 6.1.1
Reference No.: 171213C06


                                          Release Control Record


Issue No.             Description                                         Date Issued
SA170224C10B          Original release.                                   Mar. 07, 2018




Report No.: SA170224C10B                     Page No. 3 / 6        Report Format Version: 6.1.1
Reference No.: 171213C06


1    Certificate of Conformity


            Product: Dual-band Wireless Repeater

              Brand: ASUS

        Test Model: RP-AC55

      Series Model: RP-AC1200

    Sample Status: Engineering sample

          Applicant: ASUSTeK COMPUTER INC.

          Test Date: Jan. 09 ~ Mar. 06, 2018

         Standards: FCC Part 2 (Section 2.1091)
                           KDB 447498 D03 (January 17, 2014)
                           IEEE C95.1



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                               , Date:       Mar. 07, 2018
                                  Polly Chien / Specialist




     Approved by :                                                , Date:       Mar. 07, 2018
                              Bruce Chen / Project Engineer




Report No.: SA170224C10B                         Page No. 4 / 6                      Report Format Version: 6.1.1
Reference No.: 171213C06


2     RF Exposure
2.1 Limits for Maximum Permissible Exposure (MPE)
    Frequency Range          Electric Field     Magnetic Field       Power Density         Average Time
         (MHz)              Strength (V/m)      Strength (A/m)         (mW/cm2)              (minutes)
                             Limits For General Population / Uncontrolled Exposure

       300-1500                   …                    …                  F/1500                  30

     1500-100,000                 …                    …                   1.0                    30
F = Frequency in MHz

2.2 MPE Calculation Formula
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm

2.3 Classification

The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So,
this device is classified as Mobile Device.




Report No.: SA170224C10B                       Page No. 5 / 6                        Report Format Version: 6.1.1
Reference No.: 171213C06


3    Calculation Result of Maximum Conducted Power
    Frequency Band          Max Power       Antenna Gain  Distance           Power Density         Limit
        (MHz)                 (dBm)             (dBi)       (cm)               (mW/cm2)          (mW/cm2)
                                             WLAN: CDD Mode
       2412-2462               23.53             5.60             20              0.163                1
       5180-5240               24.44             7.73             20              0.328                1
       5745-5825               24.91             7.73             20              0.365                1
                                         WLAN: Beamforming Mode
       2412-2462               23.53             5.60             20              0.163                1
       5180-5240               24.25             7.73             20              0.314                1
       5745-5825               24.91             7.73             20              0.365                1
                                                  BT EDR
       2402-2480                7.02             1.75             20              0.001                1
* The WLAN 2.4GHz can transmit with WLAN 5GHz at the same time except BT.

Note:
WLAN 2.4GHz: Directional gain = 2.59dBi + 10log(2)=5.60dBi
WLAN 5GHz: Directional gain = 4.72dBi + 10log(2)=7.73dBi
BT EDR: Antenna gain = 1.75dBi

Conclusion:
The formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density


WLAN 2.4GHz + WLAN 5GHz = 0.163 + 0.365 = 0.528 < 1

Therefore the maximum calculations of above situations are less than the “1” limit.




---END---




Report No.: SA170224C10B                      Page No. 6 / 6                          Report Format Version: 6.1.1
Reference No.: 171213C06



Document Created: 2018-03-30 13:21:11
Document Modified: 2018-03-30 13:21:11

© 2024 FCC.report