RF Exposure Info.pdf

FCC ID: MQT-XAPT103PU

RF Exposure Info

Download: PDF
FCCID_2108854

                                     RF EXPOSURE REPORT
                                         REPORT NO.: SA130902E05
                                           MODEL NO.: xAPT-103PU
                                                    FCC ID: MQT-XAPT103PU

                                              RECEIVED: Sep. 02, 2013

                                                  TESTED: Sep. 24, 2013

                                                   ISSUED: Oct. 09, 2013



                                            APPLICANT: XAC AUTOMATION CORP.

                                              ADDRESS: 4F, No. 30, INDUSTRY E. RD. IX,
                                                       SCIENCE-BASED INDUSTRIAL
                                                       PARK,HSINCHU,TAIWAN

                                  ISSUED BY : Bureau Veritas Consumer Products Services
                                               (H.K.) Ltd., Taoyuan Branch Hsin Chu
                                               Laboratory
                               LAB ADDRESS : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung
                                               Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307,
                                               Taiwan, R.O.C.
                            TEST LOCATION (1): No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung
                                               Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307,
                                               Taiwan, R.O.C.
                            TEST LOCATION (2): No. 49, Ln. 206, Wende Rd., Shangshan Tsuen,
                                               Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan,
                                               R.O.C.
 This report should not be used by the client to claim
 product certification, approval, or endorsement by any
 government agencies.




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is
permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set
forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or
identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the
information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our
negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue
within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the
report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or
non-compliance to the specification

 Report No.: SA130902E05                                               1 of 10                                             Report Format Version 5.0.0


                                   TABLE OF CONTENTS
RELEASE CONTROL RECORD ..................................................................................... 3
1 CERTIFICATION ...................................................................................................... 4
2 EVALUATION RESULT ............................................................................................ 5
3 SAR TEST EXCLUSION THRESHOLDS ................................................................. 6
3.1 SAR TEST EXCLUSION THRESHOLDS - RFID ...................................................... 6
3.2 SAR TEST EXCLUSION THRESHOLDS - GSM AND WCDMA............................... 8




Report No.: SA130902E05                              2 of 10                                Report Format Version 5.0.0


                            RELEASE CONTROL RECORD

 ISSUE NO.                REASON FOR CHANGE               DATE ISSUED
 SA130902E05              Original release                Oct. 09, 2013




Report No.: SA130902E05                      3 of 10   Report Format Version 5.0.0


1     CERTIFICATION


              PRODUCT:        Terminal
         BRAND NAME:          XAC
            MODEL NO.:        xAPT-103PU
        TEST SAMPLE:          ENGINEERING SAMPLE
            APPLICANT:        XAC AUTOMATION CORP.
        TESTED DATE:          Sep. 24, 2013
           STANDARDS:         FCC Part 2 (Section 2.1091)
                              FCC OET Bulletin 65, Supplement C (01-01)
                              IEEE C95.1


The above equipment (Model: xAPT-103PU) has been tested by Bureau Veritas
Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance
with the requirement of the above standards. The test record, data evaluation &
Equipment Under Test (EUT) configurations represented herein are true and accurate
accounts of the measurements of the sample’s EMC characteristics under the
conditions specified in this report.




    PREPARED BY           :                                  , DATE: Oct. 09, 2013
                               ( Claire Kuan, Specialist )


    APPROVED BY           :                                  , DATE: Oct. 09, 2013
                                ( May Chen, Manager )




Report No.: SA130902E05                    4 of 10                    Report Format Version 5.0.0


2     EVALUATION RESULT

Following FCC KDB 447498 D01 “General SAR test exclusion guidance”

The corresponding SAR Exclusion Threshold condition, listed below:

1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test
  separation distances ≤ 50 mm are determined by:
  [(max. power of channel, including tune-up tolerance, mW)/(min. test separation
  distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR where
       f(GHz) is the RF channel transmit frequency in GHz
       Power and distance are rounded to the nearest mW and mm before calculation
       The result is rounded to one decimal place for comparison
  The test exclusions are applicable only when the minimum test separation distance is
  ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the
  minimum test separation distance is < 5 mm, a distance of 5 mm is applied to
  determine SAR test exclusion.

2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test
  exclusion threshold is determined according to the following:
  a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)]
    mW, at 100MHz to 1500 MHz
  b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at >
    1500 MHz and ≤ 6 GHz

3) At frequencies below 100 MHz, the following may be considered for SAR test
  exclusion.
  a) The threshold at the corresponding test separation distance at 100 MHz in step 2)
    is multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and <
    200 mm.
  b) The threshold determined by the equation in a) for 50 mm and 100 MHz is
    multiplied by ½ for test separation distances ≤ 50 mm.
  c) SAR measurement procedures are not established below 100 MHz. When SAR test
    exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation
    requirements for any test results to be acceptable.




Report No.: SA130902E05                5 of 10                      Report Format Version 5.0.0


3     SAR TEST EXCLUSION THRESHOLDS

3.1 SAR TEST EXCLUSION THRESHOLDS - RFID

Smallest distance from the antenna and radiating structures or outer surface of
the device
The minimum test separation distance is determined by the smallest distance from the
antenna and radiating structures or outer surface of the device, according to the host
form factor, exposure conditions and platform requirements, to any part of the body or
extremity of a user or bystander. (See below figure)




Report No.: SA130902E05                6 of 10                     Report Format Version 5.0.0


Power table

                               Frequency                Electric field           EIRP
          Mode
                                 (MHz)                (dBuV/m) @3m              (dBm)

          RFID                    13.56                    69.9                  -25.3

Field strength is then converted to EIRP as follows:
(i) EIRP = ((E*d)^2) / 30
where:
E is the field strength in V/m;
d is the measurement distance in meters;
EIRP is the equivalent isotropically radiated power in watts.
(ii) Working in dB units, the above equation is equivalent to: EIRP[dBm] = E[dBμV/m] + 20
log(d[meters]) - 104.77
(iii) Or, if d is 10 meters: EIRP[dBm] = E[dBμV/m] – 84.8
          If d is 3meters: EIRP[dBm] = E[dBμV/m] – 95.2

SAR Test Exclusion Thresholds
                                             Min. test  SAR test exclusion
    Frequency             Max. Power
                                            separation  power thresholds *2           Result
      (MHz)                (mW)*1
                                          distance (mm)       (mW)
       13.56               0.002951         ≤ 50 mm                 593                Pass

*1 Max. power obtained from maximum EIRP.
*2 Calculate SAR test exclusion thresholds from “ 3) ” formulas. (base on 10-g extremity
    SAR exclusion thresholds)

Conclusion
Since maximum EIRP is below SAR test exclusion power thresholds, the SAR
evaluation is not required.

Report No.: SA130902E05                     7 of 10                       Report Format Version 5.0.0


3.2 SAR TEST EXCLUSION THRESHOLDS - GSM AND WCDMA
Smallest distance from the antenna and radiating structures or outer surface of
the device
The minimum test separation distance is determined by the smallest distance from the
antenna and radiating structures or outer surface of the device, according to the host
form factor, exposure conditions and platform requirements, to any part of the body or
extremity of a user or bystander. (See below figure)




Report No.: SA130902E05                8 of 10                     Report Format Version 5.0.0


Source-base time average power table

GPRS Mode:
                                                                   Source-based
                                                                   time-averaged
     Frequency          Conducted power        Conducted power
                                                                  conducted output
        (MHz)                 (dBm)                    (mW)
                                                                       power
                                                                        (mW)
        848.8                  32.6                   1819.7             455
       1850.2                   29                    794.32           198.61
Note: Calculations for RF Exposure compliance in the cellular and PCS bands are base
on the maximum source based time-average power obtained from 2-Slot GPRS
operation. The resulting duty cycle factor is 2/8, or 6.02dB.

SAR Test Exclusion Thresholds
                                          Min. test  SAR test exclusion
                          Max. Power
    Frequency                            separation  power thresholds *2        Result
                           (mW)*1
                                       distance (mm)       (mW)
      848.8            455               80                576.74     Pass
     1850.2           198.61             80                575.67     Pass
 1
* Max. power obtained from maximum source based time average power.
*2 Calculate SAR test exclusion thresholds from “ 1) & 2) ” formulas.
   (base on 10-g extremity SAR exclusion thresholds)




Report No.: SA130902E05                  9 of 10                    Report Format Version 5.0.0


Conclusion
Since Source-base time average power is below SAR test exclusion power thresholds,
the SAR evaluation is not required.