Test Report Part 1 Revised

FCC ID: MOZF02RG

Test Report

Download: PDF
FCCID_896793

                                                                                 Test report No.    : 28EE0022-HO-01-B-R1
                                                                                 Page               : 1 of 14
                                                                                 Issued date        : January 15, 2008
                                                                                 Revised date       : January 23, 2008
                                                                                 FCC ID             : MOZF02RG



                                  EMI TEST REPORT
                         Test Report No. : 28EE0022-HO-01-B-R1
          Applicant                         :         Tokai Rika Co., Ltd.

          Type of Equipment                 :         Receiver

          Model No.                         :         F02RG

          Test standard                     :         FCC Part 15 Subpart B 2007

          FCC ID                            :         MOZF02RG

          Test Result                       :         Complied
          1. This test report shall not be reproduced in full or partial, without the written approval of
             UL Japan, Inc.
          2. The results in this report apply only to the sample tested.
          3. This sample tested is in compliance with the above regulation.
          4. The test results in this report are traceable to the national or international standards.
          5. Original test report number of this report is 28EE0022-HO-01-B.

                       Date of test:
                                                         December 23, 2007
                                                   ______________________________

                       Tested by:
                                                   ______________________________
                                                            Makoto Kosaka
                                                            EMC Services

                       Approved by :               ______________________________
                                                           Mitsuru Fujimura
                                                         Assistant Manager of
                                                            EMC Services

                                                          This laboratory is accredited by the NVLAP LAB CODE
                                                          200572-0, U.S.A. The tests reported herein have been
                                                          performed in accordance with its terms of accreditation.
                                                          *As for the range of Accreditation in NVLAP, you may
                                                          refer to the WEB address,
          NVLAP LAB CODE: 200572-0                        http://uljapan.co.jp/emc/nvlap.htm


UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN                                                MF060b (18.06.07)
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                                       Test report No.         : 28EE0022-HO-01-B-R1
                                                                                                       Page                    : 2 of 14
                                                                                                       Issued date             : January 15, 2008
                                                                                                       Revised date            : January 23, 2008
                                                                                                       FCC ID                  : MOZF02RG




CONTENTS                                                                                                                                  PAGE

SECTION 1: Customer information ...................................................................................... 3
SECTION 2: Equipment under test (E.U.T.) ........................................................................ 3
SECTION 3: Test specification, procedures & results ......................................................... 4
SECTION 4: Operation of E.U.T. during testing ................................................................. 7
SECTION 5: Radiated Emission ............................................................................................ 8
APPENDIX 1: Photographs of test setup............................................................................... 9
     Radiated Emission ......................................................................................................................... 9
     Worst Case Position..................................................................................................................... 10
APPENDIX 2: Data of EMI test ........................................................................................... 12
     Radiated Emission ....................................................................................................................... 12
APPENDIX 3: Test instruments ........................................................................................... 14




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                Test report No.   : 28EE0022-HO-01-B-R1
                                                                                Page              : 3 of 14
                                                                                Issued date       : January 15, 2008
                                                                                Revised date      : January 23, 2008
                                                                                FCC ID            : MOZF02RG




SECTION 1: Customer information
Company Name                       :        Tokai Rika Co., Ltd.
Address                            :        3-260 Toyota, Oguchi-cho, Niwa-gun, Aichi-ken, 480-0195 Japan
Telephone Number                   :        +81-587-95-0093
Facsimile Number                   :        +81-587-95-5471
Contact Person                     :        Toshihito Kunii



SECTION 2: Equipment under test (E.U.T.)
2.1     Identification of E.U.T.

Type of Equipment                  :        Receiver
Model No.                          :        F02RG
Serial No.                         :        4
Country of Manufacture             :        Japan
Receipt Date of Sample             :        December 20, 2007
Condition of EUT                   :        Production model
Modification of EUT                :        No modification by the test lab.


2.2     Product Description

Model No: F02RG is the Receiver.

Clock frequency in the system      :        CPU:4.981MHz
Type of Receiver                   :        Super Heterodyne
Receiving Frequency                :        312.15MHz
Local Oscillator Frequency         :        308.55MHz (102.85MHz x 3)
Intermediate Frequency             :        3.6MHz
Method of Frequency Generation     :        Crystal
Power Supply                       :        DC12.0V


FCC15.111(b)
The receiving antenna (of this EUT) is installed inside the vehicle in which the EUT is installed, and cannot be removed by
the user. Therefore, this EUT complies with the requirement in section 15.111(b).




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                  Test report No.   : 28EE0022-HO-01-B-R1
                                                                                  Page              : 4 of 14
                                                                                  Issued date       : January 15, 2008
                                                                                  Revised date      : January 23, 2008
                                                                                  FCC ID            : MOZF02RG


SECTION 3: Test specification, procedures & results
3.1     Test specification

Test Specification           : FCC Part 15 Subpart B 2007
Title                        : FCC 47CFR Part15 Radio Frequency Device
                               Subpart B Unintentional Radiators


3.2     Procedures and results

 Item                    Test Procedure                      Limits         Deviation Worst margin                      Result
                         FCC: ANSI C63.4: 2003
                         7. AC powerline
 Conducted emission conducted emission                       Receiver       N/A          N/A *1)                        N/A
                         measurements
                         IC: RSS-Gen 7.2.2
                         FCC: ANSI C63.4: 2003
                                                                                         19.5B
                         8. Radiated
 Radiated emission                                           Receiver       N/A          925.650MHz                     Complied
                         emission measurements
                                                                                         Horizontal/Vertical
                         IC: RSS-Gen 4.10
 *Note: UL Japan, Inc’s EMI Work Procedure QPM05.
 *1) The test is not applicable since the EUT is not the device that is designed to be connected to the public utility (AC) power
 line.
*These tests were performed without any deviations from test procedure except for additions or exclusions.


3.3     Additions or deviations to standards

No addition nor deviation has been made from standards.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                    Test report No.     : 28EE0022-HO-01-B-R1
                                                                                    Page                : 5 of 14
                                                                                    Issued date         : January 15, 2008
                                                                                    Revised date        : January 23, 2008
                                                                                    FCC ID              : MOZF02RG



3.4      Uncertainty

EMI
The following uncertainties have been calculated to provide a confidence level of 95% using a coverage factor k=2.

                  Conducted              Radiated emission                 Radiated emission                   Radiated
                   emission                   (10m*)                            (3m*)                          emission
   Test room                                                                                                    (3m*)
                   150kHz-       9kHz-      30MHz-      300MHz-      9kHz-      30MHz-        300MHz-      1GHz-     18GHz-
                   30MHz        30MHz       300MHz        1GHz      30MHz       300MHz          1GHz       18GHz      40GHz
 No.1               ±3.7dB      ±3.1dB       ±4.7dB      ±4.4dB     ±3.2dB       ±3.7dB        ±4.4dB      ±5.9dB     ±6.1dB
 semi-anechoic
 chamber
 No.2               ±3.7dB         -            -            -      ±3.2dB      ±4.3dB         ±3.9dB      ±5.9dB     ±6.1dB
 semi-anechoic
 chamber
 No.3               ±3.7dB         -            -            -      ±3.2dB      ±4.2dB         ±4.4dB      ±5.9dB     ±6.1dB
 semi-anechoic
 chamber
 No.4               ±3.7dB         -            -            -      ±3.2dB      ±4.2dB         ±4.4dB      ±5.9dB     ±6.1dB
 semi-anechoic
 chamber
*10m/3m = Measurement distance

Radiated emission test(3m and/or 10m)
The data listed in this test report has enough margin, more than the site margin.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                       Test report No.     : 28EE0022-HO-01-B-R1
                                                                                       Page                : 6 of 14
                                                                                       Issued date         : January 15, 2008
                                                                                       Revised date        : January 23, 2008
                                                                                       FCC ID              : MOZF02RG



3.5      Test Location

UL Japan, Inc. Head Office EMC Lab. *NVLAP Lab. code: 200572-0
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8116          Facsimile : +81 596 24 8124
                        FCC           IC Registration    Width x Depth x         Size of                        Other
                        Registration Number              Height (m)              reference ground plane (m) /   rooms
                        Number                                                   horizontal conducting plane
 No.1 semi-anechoic     313583        IC4247             19.2 x 11.2 x 7.7m      7.0 x 6.0m                     No.1 Power
 chamber                                                                                                        source room
 No.2 semi-anechoic     655103        IC4247-2           7.5 x 5.8 x 5.2m        4.0 x 4.0m                     -
 chamber
 No.3 semi-anechoic     148738        IC4247-3           12.0 x 8.5 x 5.9m       6.8 x 5.75m                    No.3
 chamber                                                                                                        Preparation
                                                                                                                room
 No.3 shielded room     -              -                   4.0 x 6.0 x 2.7m      N/A                            -
 No.4 semi-anechoic     134570         IC4247-4            12.0 x 8.5 x 5.9m     6.8 x 5.75m                    No.4
 chamber                                                                                                        Preparation
                                                                                                                room
 No.4 shielded room     -              -                   4.0 x 6.0 x 2.7m      N/A                            -
 No.5 semi-anechoic     -              -                                                                        -
                                                           6.0 x 6.0 x 3.9m      6.0 x 6.0m
 chamber
 No.6 shielded          -              -                   4.0 x 4.5 x 2.7m      4.75 x 5.4 m                   -
 room
 No.6 measurement       -              -                   4.75 x 5.4 x 3.0m     4.75 x 4.15 m                  -
 room
 No.7 shielded room     -              -                   4.7 x 7.5 x 2.7m      4.7 x 7.5m                     -
 No.8 measurement         -               -                3.1 x 5.0 x 2.7m         N/A                           -
 room
 No.9 measurement         -               -                8.0 x 4.5 x 2.8m         N/A                           -
 room
 No.10 measurement        -               -                2.6 x 2.8 x 2.5m         2.4 x 2.4m                    -
 room
 No.11 measurement        -               -                3.1 x 3.4 x 3.0m         2.4 x 3.4m                    -
 room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 x 2.0m for No.1, No.2, No.3, and No.4 semi-anechoic chambers
and No.3 and No.4 shielded rooms.

3.6    Test set up, Data of EMI, and Test instruments

Refer to APPENDIX 1 to 3.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                 Test report No.   : 28EE0022-HO-01-B-R1
                                                                                 Page              : 7 of 14
                                                                                 Issued date       : January 15, 2008
                                                                                 Revised date      : January 23, 2008
                                                                                 FCC ID            : MOZF02RG




SECTION 4: Operation of E.U.T. during testing
4.1     Operating modes

The mode is used              :   Receiving mode:
                                  When you press each switch (unlock/lock) on RKE Transmitter, the Transmitter transmits
                                  a radio wave to Receiver. When you press lock switch, “Lock” LED is turned ON
                                  immediately.
                                  When you press unlock switch, “Unlock 1” LED is turned ON immediately.
                                  “Unlock 2” is not used for testing purpose.

                                  *RKE Transmitter(F01TG) was operated manually by a test engineer and the test was
                                   performed with the EUT receiving 312.15MHz.

4.2     Configuration and peripherals

                                      1                                                                  C
                     E

                                       D                                               A
                                                         2              3                            4           B

                                                     Unlock 2
                              Lock Unlock 1

                                                                                                   : Connector

                                                                                                   : LED
*Cabling and setup were taken into consideration and test data was taken under worse case conditions.

Description of EUT and Support equipment
 No. Item                Model number    Serial number              Manufacturer            Remark
  A Receiver             F02RG           4                          Tokai Rika Co.,         EUT
                                                                    Ltd.
  B    Antenna                -                  -                  Tokai Rika Co.,         EUT
                                                                    Ltd.
  C    RKE Transmitter        F01TG              2                  Tokai Rika Co.,         -
                                                                    Ltd.
  D    Test Box               -                  -                  -                       -
  E    Car Battery            40B19L             A030402            YUASA                   -

List of cables used
 No. Name                                        Length (m)                           Shield
                                                                    Cable                  Connector
  1    DC Cable                                  2.5                Unshielded             Unshielded
  2    Signal & Power Cable                      0.18               Unshielded             Unshielded
  3    Signal & Power Cable                      0.13               Unshielded             Unshielded
  4    Antenna Cable                             0.95               Shielded               Shielded

UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                               Test report No.   : 28EE0022-HO-01-B-R1
                                                                               Page              : 8 of 14
                                                                               Issued date       : January 15, 2008
                                                                               Revised date      : January 23, 2008
                                                                               FCC ID            : MOZF02RG




SECTION 5: Radiated Emission
5.1   Operating environment

Test place                 : No.3 semi anechoic chamber
Temperature                : See data
Humidity                   : See data


5.2   Test configuration

EUT was placed on a urethane platform of nominal size, 1.0m by 0.5m, raised 80cm above the conducting ground plane.
The EUT was set on the edge of the tabletop.
Test was made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement antenna
was varied in height above the conducting ground plane to obtain the maximum signal strength.
A drawing of the set up is shown in the photos of APPENDIX 1.

5.3   Test conditions

Frequency range           : 30MHz – 300MHz (Biconical antenna) / 300MHz – 1000MHz (Logperiodic antenna)
                            1000-2000MHz (Horn antenna)
Test distance             : 3m
EUT position              : Table top
EUT operation mode        : See Clause 4.1


5.4   Test procedure

The height of the measuring varied between 1 and 4m and EUT was rotated a full revolution in order to obtain the
maximum value of the electric field intensity.
The measurements were performed for both vertical and horizontal antenna polarization with the Test Receiver, or the
Spectrum Analyzer (in linear mode).
The test was made with the detector (RBW/VBW) in the following table.
When using Spectrum analyzer, the test was made with adjusting span to zero by using peak hold.
  Frequency            Below 1GHz                     Above 1GHz
  Instrument used      Test Receiver                  Spectrum Analyzer
  IF Bandwidth         QP: BW 120kHz                  PK: RBW:1MHz/VBW: 1MHz
                                                      AV: RBW:1MHz/VBW:10Hz

- The noise levels were confirmed at each position of X, Y and Z axes of EUT to see the position of maximum noise, and the test
was made at the position that has the maximum noise.


5.5   Test result

Summary of the test results: Pass

Date: December 23, 2007                                       Test engineer: Makoto Kosaka



UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124



Document Created: 2008-01-24 09:01:45
Document Modified: 2008-01-24 09:01:45

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC