MPE Report

FCC ID: MG3-I05020

RF Exposure Info

Download: PDF
FCCID_4322007

                                               FCC MPE REPORT
                                                                   Certification

Applicant Name:                                                                   Date of Issue:
Universal Electronics Inc                                                         May 22, 2019
                                                                                  Test Site/Location:
Address:                                                                          EMCE Engineering
201 East Sandpointe Ave 8th Floor                                                 1726 Ringwood Avenue San Jose, California USA
Santa Ana, CA 92707, U.S.A.
                                                                                  Report No.: EMCE-R-1905-F004-1

FCC ID:                                    MG3-I05020
IC:                                        2575A-I05020
APPLICANT:                                 Universal Electronics Inc

Model:                                     I05020

Additional Model:                          N/A

EUT Type:                                  Smart Home Hub




   The measurements shown in this report were made in accordance with the procedures specified in §2.947. I assume full


   responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them.

   EMCE Engineering, Inc. Certifies that no party to this application has subject to a denial of Federal benefits that includes FCC benefits


   pursuant to section 5301 of the Anti-Drug Abuse Act of 1998,21 U.S. C.853(a)




   Steve.In                                                                       Billy Kim
   Test Engineer                                                                  Technical Manager
   Certification Division                                                         Certification Division
   This report only responds to the tested sample and may not be reproduced, except in full, without written approval of the EMCE Engineering, Inc..




Report No.: EMCE-R-1905-F004-1
                                                                                                                                                       1/5

     This document may not be copied or reproduced (reprinted) without written consent by EMCE Engineering, Inc.
                     EMCE Engineering, Inc., 1726 Ringwood Avenue, San Jose, CA 95131, USA
                                  TEL: +1-510-933-8848 FAX: +1-510-933-8849


                                                Version
     TEST REPORT NO.                    DATE                                    DESCRIPTION

     EMCE-R-1905-F004               May 22, 2019                            - First Approval Report

    EMCE-R-1905-F004-1               June 17, 2019                           - Revised antenna gain




Report No.: EMCE-R-1905-F004-1
                                                                                                                   2/5

     This document may not be copied or reproduced (reprinted) without written consent by EMCE Engineering, Inc.
                     EMCE Engineering, Inc., 1726 Ringwood Avenue, San Jose, CA 95131, USA
                                  TEL: +1-510-933-8848 FAX: +1-510-933-8849


   RF Exposure Statement
   1. LIMITS
   According to §1.1310 and §2.1091 RF exposure is calculated.


                            (B) Limits for General Population/Uncontrolled Exposures

            Frequency range                  Electric field       Magnetic field      Power density   Averaging time
                 (MHz)                      Strength (V/m)      Strength (A/m)           (mW/cm²)       (minutes)




 0.3 - 1.34…………………………………                             614                  1.63             *(100)                  30
 1.34 - 30…………………………………                             824/f               2.19/f          *(180/ f²)                 30
 30 - 300…………………………………                               27.5               0.073                 0.2                  30
 300 - 1500………………………………                           …………...             …………...              f/1500                  30
 1500 - 100.000……………………………                        …………...             …………...                 1.0                  30



       F = frequency in MHz
       * = Plane-wave equivalent power density


   2. MAXIMUM PERMISSIBLE EXPOSURE Prediction
   Prediction of MPE limit at a given distance


   S = PG/4πR²

   S = Power density
   P = power input to antenna
   G = power gain of the antenna in the direction of interest relative to an isotropic radiator
   R = distance to the center of radiation of the antenna




Report No.: EMCE-R-1905-F004-1
                                                                                                                   3/5

     This document may not be copied or reproduced (reprinted) without written consent by EMCE Engineering, Inc.
                     EMCE Engineering, Inc., 1726 Ringwood Avenue, San Jose, CA 95131, USA
                                  TEL: +1-510-933-8848 FAX: +1-510-933-8849


   3. RESULTS

   3-1. Bluetooth
   Average output Power at antenna input terminal                              8.77       dBm
   Average output Power at antenna input terminal                             7.534        mW
   Prediction distance                                                       20.000        cm
   Prediction frequency                                                2402 ~ 2480        MHz
   Antenna Gain(typical)                                                       5.96        dBi
   Antenna Gain(numeric)                                                      3.945         -
   Power density at prediction frequency( S)                              0.005912      mW/cm2
   MPE limit for uncontrolled exposure at prediction frequency                1.000     mW/cm2

   3-2. Zigbee
   Average output Power at antenna input terminal                              8.72       dBm
   Average output Power at antenna input terminal                             7.447        mW
   Prediction distance                                                       20.000        cm
   Prediction frequency                                                2402 ~ 2480        MHz
   Antenna Gain(typical)                                                       5.96        dBi
   Antenna Gain(numeric)                                                      3.945         -
   Power density at prediction frequency( S)                              0.005844      mW/cm2
   MPE limit for uncontrolled exposure at prediction frequency                1.000     mW/cm2

   3-3. DTS

   Average output Power at antenna input terminal                             13.55       dBm

   Average output Power at antenna input terminal                            22.646        mW

   Prediction distance                                                       20.000        cm

   Prediction frequency                                              2 412 ~ 2 472        MHz

   Antenna Gain(typical)                                                       5.96        dBi

   Antenna Gain(numeric)                                                      3.945         -

   Power density at prediction frequency( S)                              0.017772      mW/cm2

   MPE limit for uncontrolled exposure at prediction frequency                1.000     mW/cm2




Report No.: EMCE-R-1905-F004-1
                                                                                                                   4/5

     This document may not be copied or reproduced (reprinted) without written consent by EMCE Engineering, Inc.
                     EMCE Engineering, Inc., 1726 Ringwood Avenue, San Jose, CA 95131, USA
                                  TEL: +1-510-933-8848 FAX: +1-510-933-8849


   -> Worst Case: Simultaneous MPE 20cm is

   Simultaneous MPE 20cm is WLAN(2.4 GHz) (0.017772/1.0) + Bluetooth (0.005912/1.0) = 0.023684 < 1


   Simultaneous MPE 20cm is WLAN(2.4 GHz) (0.017772/1.0) + Zigbee (0.005844/1.0) = 0.023616 < 1




Report No.: EMCE-R-1905-F004-1
                                                                                                                   5/5

     This document may not be copied or reproduced (reprinted) without written consent by EMCE Engineering, Inc.
                     EMCE Engineering, Inc., 1726 Ringwood Avenue, San Jose, CA 95131, USA
                                  TEL: +1-510-933-8848 FAX: +1-510-933-8849



Document Created: 2019-06-17 17:41:26
Document Modified: 2019-06-17 17:41:26

© 2025 FCC.report