Test report

FCC ID: MDZ55LV4400UA

Test Report

Download: PDF
FCCID_1520148

                                                                    Report No: T110714101-D


              FCC 47 CFR PART 15 SUBPART B
                      TEST REPORT
                                           for

                    55” LCD TV, LCD Monitor, LED LCD TV
            MODEL: 55LV4400; 55LV4400XXX (“ X “ may be any
                   alphanumeric character or blank)
                            FCC ID: MDZ55LV4400UA
                                  Test Report Number:
                                    T110714101-D

                                       Issued for

                             Amtran Technology Co., Ltd.
17F., No. 268, Liancheng Rd., Jhonghe District New Taipei City 23553, Taiwan, R.O.C.

                                       Issued By:
                          Compliance Certification Services Inc.
                                   Linkuo Laboratory
                   No.81-1, Lane 210, Bade 2nd Rd., Lujhu Township,
                        Taoyuan County 33841,Taiwan, R.O.C.
                                 TEL: 886-3-324-0332
                                 FAX: 886-3-324-5235
                               E-Mail: service@ccsrf.com
                               Issued Date: July 30, 2011




Note: This report shall not be reproduced except in full, without the written approval of
Compliance Certification Services Inc. This document may be altered or revised by
Compliance Certification Services Inc. personnel only, and shall be noted in the revision
section of the document. The client should not use it to claim product endorsement by TAF,
A2LA, NIST or any government agencies. The test results in the report only apply to the
tested sample.

                                            Page 1 / 28                             Rev.00


                                                                                             Report No: T110714101-D



                                               Revision History
                    Issue                                                                      Effect
Rev.                 Date                                   Revisions                          Page         Revised By
00        July 30, 2011                  Initial Issue                                           All       Landy Huang




                                                          Page 2                                                  Rev.00
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                                             Report No: T110714101-D


                                                  TABLE OF CONTENTS
1        TEST RESULT CERTIFICATION........................................................................................ 4
2        EUT DESCRIPTION ............................................................................................................ 5
3        TEST METHODOLOGY ...................................................................................................... 6
 3.1.    DECISION OF FINAL TEST MODE..................................................................................... 6
 3.2.    EUT SYSTEM OPERATION ................................................................................................ 6
4        SETUP OF EQUIPMENT UNDER TEST............................................................................. 7
 4.1.    DESCRIPTION OF SUPPORT UNITS ................................................................................ 7
 4.2.    CONFIGURATION OF SYSTEM UNDER TEST ................................................................. 8
5        FACILITIES AND ACCREDITATIONS................................................................................ 9
 5.1.    FACILITIES .......................................................................................................................... 9
 5.2.    ACCREDITATIONS ............................................................................................................. 9
 5.3.    MEASUREMENT UNCERTAINTY..................................................................................... 10
6        CONDUCTED EMISSION MEASUREMENT .................................................................... 11
 6.1.    LIMITS OF CONDUCTED EMISSION MEASUREMENT .................................................. 11
 6.2.    TEST INSTRUMENTS ....................................................................................................... 11
 6.3.    TEST PROCEDURES........................................................................................................ 12
 6.4.    TEST SETUP ..................................................................................................................... 13
 6.5.    DATA SAMPLE: ................................................................................................................. 13
 6.6.    TEST RESULTS ................................................................................................................ 14
7        RADIATED EMISSION MEASUREMENT ......................................................................... 16
 7.1.    LIMITS OF RADIATED EMISSION MEASUREMENT ....................................................... 16
 7.2.    TEST INSTRUMENTS ....................................................................................................... 17
 7.3.    TEST PROCEDURES........................................................................................................ 18
 7.4.    TEST SETUP ..................................................................................................................... 19
 7.5.    DATA SAMPLE: ................................................................................................................. 20
 7.6.    TEST RESULTS ................................................................................................................ 21
8        PHOTOGRAPHS OF THE TEST CONFIGURATION ....................................................... 25
APPENDIX 1: PHOTOGRAPHS OF EUT ..................................................................................... 28




                                                                     Page 3                                                           Rev.00
    This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                               Report No: T110714101-D


1 TEST RESULT CERTIFICATION
        Product: 55” LCD TV, LCD Monitor, LED LCD TV
           Model: 55LV4400; 55LV4400XXX (“ X “ may be any alphanumeric character or blank)
           Brand: LG
      Applicant: Amtran Technology Co., Ltd.
                 17F., No. 268, Liancheng Rd., Jhonghe District New Taipei City 23553, Taiwan, R.O.C.
  Manufacturer: 1. Amtran Electronic Co., Ltd.
                No. 225, Jinfeng Road, Suzhou New District, Suzhou, Jiangsu PRC.
                2. SuZhou Raken Technology Co., Ltd.
                No. 278, Mayun Rd., Su Zhou New District, Jiangsu, China
                3. SuZhou Raken Technology Co., Ltd. Jinfeng Branch
                No. 225, Jinfeng Road, Suzhou New District, Suzhou, Jiangsu PRC
          Tested: July 25 ~ 28, 2011
  Test Voltage: 120VAC, 60Hz


                                                      EMISSION
            Standard                                Item                   Result                   Remarks
FCC 47 CFR Part 15 Subpart B           Conducted (Main Port)               PASS          Meet Class B limit

ICES-003 Issue 4
ANSI C63.4                             Radiated                            PASS          Meet Class B limit


Note: 1. The statements of test result on the above are decided by the request of test standard only;
          the measurement uncertainties are not factored into this compliance determination.
      2. The information of measurement uncertainty is available upon the customer’s request.

                                      Deviation from Applicable Standard

                                                           None


The above equipment has been tested by Compliance Certification Services Inc., and found
compliance with the requirements set forth in the technical standards mentioned above. The
results of testing in this report apply only to the product/system, which was tested. Other
similar equipment will not necessarily produce the same results due to production tolerance
and measurement uncertainties.



Approved by:                                                     Reviewed by:




Bill Cheng                                                       Jill Shiau
Section Manager                                                  Section Manager



                                                            Page 4                                                  Rev.00
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                               Report No: T110714101-D


2 EUT DESCRIPTION
Product                                 55” LCD TV, LCD Monitor, LED LCD TV
                                        55LV4400; 55LV4400XXX (“ X “ may be any alphanumeric
Model
                                        character or blank)
Brand                                   LG

Applicant                               Amtran Technology Co., Ltd.

Serial Number                           T110714101

Received Date                           July 14, 2011

EUT Power Rating                        100-240VAC, 50/60Hz

AC Power Cord Type                      Unshielded, 1.8m (Detachable)
                                        LG Display or
LCD Panel Manufacturer                                          Model     LC550EUH
                                        Suzhou Raken
                                                                          DPS-159CP XX (“X” can be any
Power Board Manufacturer                Delta                   Model
                                                                          alphanumeric character or blank)
I/O Port
       I/O PORT TYPES                                    Q’TY                                 TESTED WITH
1. D-SUB Port                                               1                                          1
2. Audio Port                                               2                                          2
3. HDMI Port                                                3                                          3
4. Component Port (Y/Pb/Pr)                              1 Set                                      1 Set
5. Audio Port (R/L)                                      1 Set                                      1 Set
6. Optical Port                                             1                                          1
7. Coaxial Port                                             1                                          1
8. USB Port                                                 1                                          1
Note: 1. The EUT include one Remote Control for sale only.
      2. The means of “X” (“ X “ may be any alphanumeric character or blank) on model number are
        identical, just for marketing purpose only..
      3. Client consigns only one model sample (Model number: 55LV4400) to test. Therefore, testing Lab.
        just guarantees the units, which have been tested.




                                                            Page 5                                                  Rev.00
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                                 Report No: T110714101-D


3 TEST METHODOLOGY
3.1. DECISION OF FINAL TEST MODE
1.     The following test mode(s) were scanned during the preliminary test:
            Mode                 D-SUB                        Power Board                    LCD Panel
             1            1920 x 1080 / 60Hz                                                LG Display or
                                                          Delta / DPS-159CP
             2             1280 x 768 / 75Hz                                               Suzhou Raken /
                                                                   XX
             3              800 x 600 / 60Hz                                                 LC550EUH

2.      After the preliminary scan, the following test mode was found to produce the highest
        emission level.

       Final Test Mode
                         Conducted
                                             Mode 1
                         Emission
       Emission
                         Radiated
                                             Mode 1
                         Emission

        Then, the above highest emission mode of the configuration of the EUT and cable
        was chosen for all final test items.

3.2. EUT SYSTEM OPERATION
       1 EMI test program was loaded and executed in “Windows XP” mode.
       2 Data was sent to EUT filling the screen with upper case of “H” patterns.
           Test program sequentially exercised all related I/O’s of Host PC and sent “H”
       3
           patterns to all applicable output ports of Host PC.
       4 Repeat 2 to 3.
           Note: Test program is self-repeating throughout the test.




                                                              Page 6                                                  Rev.00
     This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                                  Report No: T110714101-D

4 SETUP OF EQUIPMENT UNDER TEST
4.1. DESCRIPTION OF SUPPORT UNITS
The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.

No.       Equipment        Model No.       Serial No.       FCC ID       Trade Name          Data Cable            Power Cord
                                                                                        D-SUB Cable:
                                                                                        Shielded, 1.8m
                                                                                        with two cores
                                                                                        HDMI Cable:
 1            PC           PRO 2000      SGH008RRNY        FCC DoC            HP                               Unshielded, 1.8m
                                                                                        Unshielded, 1.8m
                                                                                        Audio Cable:
                                                                                        Unshielded, 1.8m
                                                                                        with one core
 2          Modem          DM-1414         304012264      IFAXDM1414        ACEEX       Shielded, 1.8m         Unshielded, 1.8m
 3          Printer       STYLUS C60      DR3K041737       FCC DoC          EPSON       Shielded, 1.8m         Unshielded, 1.8m
 4      PS/2 Keyboard       Y-SJ17       SY520U00571       FCC DoC         Logitech     Unshielded, 1.8m                N/A
 5       PS/2 Mouse        M-CAA43       LZE03257395       FCC DoC         Logitech     Unshielded, 1.8m                N/A
                                                                                        Optical Cable:
                                                                                        Unshielded, 1.8m
 6       5.1 Amplifier      Z-5400          S-0180B        FCC DoC         Logitech                            Unshielded, 1.8m
                                                                                        Audio Cable:
                                                                                        Unshielded, 1.8m
                                                                                        HDMI Cable:
                                                                                        Unshielded, 1.8m
                                                                                        Component Cable:
 7        DVD Player       BDP-S360         1006160        FCC DoC          SONY                               Unshielded, 1.8m
                                                                                        Unshielded, 1.8m x 3
                                                                                        Audio Cable:
                                                                                        Unshielded, 1.8m x 2
                                                                                        HDMI Cable:
 8        DVD Player       BDP-S360         1005981        FCC DoC          SONY                               Unshielded, 1.8m
                                                                                        Unshielded, 1.8m
                                                                           SILICON
 9      Traveling Disk    LuxMini 720         N/A          FCC DoC                      Shielded, 0.8m                  N/A
                                                                           POWER
        Analog TV S.G.                                                                  Coaxial Cable
                           PT-5820         DM735003        FCC DoC          Phililps                           Unshielded, 1.8m
          (Remote)                                                                      Unshielded, 1.5m
 10
        Digital TV S.G.                                                                 Coaxial Cable
                           DSG300A        CA06204385       FCC DoC           DiTV                              Unshielded, 1.8m
          (Remote)                                                                      Unshielded, 1.5m
Note: Grounding was established in accordance with the manufacturer’s requirements and conditions for
the intended use.




                                                               Page 7                                                  Rev.00
      This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                                    Report No: T110714101-D


4.2. CONFIGURATION OF SYSTEM UNDER TEST
1. PC                                    2. Modem                                   3. Printer
4. PS/2 Keyboard                         5. PS/2 Mouse                              6. 5.1 Amplifier
7. DVD Player                            8. DVD Player                              9. Traveling Disk
10. TV S.G.                              ---                                        ---




                                                                                          6
                           1
                                                                 (EUT)




                      2         3         4        5         7         8        9             Remote Control
                                                                                                 (EUT)


                                                                                                Test table



                                                                                     (Remote)
                                                                                                       10




                                                            Page 8                                                  Rev.00
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                              Report No: T110714101-D


5 FACILITIES AND ACCREDITATIONS
5.1. FACILITIES
All measurement facilities used to collect the measurement data are located at
No.81-1, Lane 210, Bade 2nd Rd., Lujhu Township, Taoyuan County 33841,Taiwan, R.O.C.

The sites are constructed in conformance with the requirements of ANSI C63.4 and
CISPR Publication 22. All receiving equipment conforms to CISPR 16-1-1, CISPR 16-1-2,
CISPR 16-1-3, CISPR 16-1-4, CISPR 16-1-5 and CISPR 16-2-3.

5.2. ACCREDITATIONS
Our laboratories are accredited and approved by the following approval agencies
according to ISO/IEC 17025.

                                 Taiwan                    TAF
                                 USA                       A2LA


The measuring facility of laboratories has been authorized or registered by the following
approval agencies.
                          Canada             Industry Canada
                          Norway             Nemko
                          Japan              VCCI
                          Taiwan             BSMI
                          USA                FCC

Copies of granted accreditation certificates are available for downloading from our web
site, http:///www.ccsrf.com




                                                           Page 9                                                  Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                              Report No: T110714101-D




5.3. MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for
tests performed on the EUT as specified in CISPR 16-4-2:


            Measurement                                Frequency                             Uncertainty
       Conducted emissions                            9kHz~30MHz                               ± 2.0878
                                                       30~200MHz                               ± 3.8856
                                                     200~1000MHz                               ± 3.8721
                                                          1~8GHz                               ± 1.7947
         Radiated emissions
                                                         8~18GHz                               ± 1.9019
                                                        18~26GHz                               ± 2.1599
                                                        26~40GHz                               ± 2.6612
       This uncertainty represents an expanded uncertainty expressed at approximately the 95%
       confidence level using a coverage factor of k=2.
       Consistent with industry standard (e.g. CISPR 22: 2006, clause 11, Measurement Uncertainty)
       determining compliance with the limits shall be base on the results of the compliance
       measurement. Consequently the measure emissions being less than the maximum allowed
       emission result in this be a compliant test or passing test.
       The acceptable measurement uncertainty value without requiring revision of the compliance
       statement is base on conducted and radiated emissions being less than UCISPR which is 3.6dB
       and 5.2dB respectively. CCS values (called ULab in CISPR 16-4-2) is less than UCISPR as shown
       in the table above. Therefore, MU need not be considered for compliance.




                                                           Page 10                                                 Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                               Report No: T110714101-D


6 CONDUCTED EMISSION MEASUREMENT
6.1. LIMITS OF CONDUCTED EMISSION MEASUREMENT
                                           Class A (dBuV)                                   Class B (dBuV)
 FREQUENCY (MHz)
                                 Quasi-peak                Average               Quasi-peak                Average
       0.15 - 0.5                     79                       66                   66 - 56                  56 - 46
       0.50 - 5.0                     73                       60                      56                      46
       5.0 - 30.0                     73                       60                      60                      50
NOTE:
(1) The lower limit shall apply at the transition frequencies.
(2) The limit decreases in line with the logarithm of the frequency in the range 0.15 to 0.50 MHz.
(3) All emanations from a class A/B digital device or system, including any network of conductors and
    apparatus connected thereto, shall not exceed the level of field strengths specified above.

6.2. TEST INSTRUMENTS
                                        Conducted Emission Room # 3
Name of Equipment Manufacturer                            Model               Serial Number           Calibration Due
  EMI Test Receiver                R&S                  ESCS30                  845552/030               05/31/2012
         LISN                      R&S               ENV216                        100069                06/20/2012
                                                FCC-LISN-50/250-16
         LISN                      FCC                                              06013                11/21/2011
                                                       -2-07
          ISN                      FCC           FCC-TLISN-T2-02                    20587                06/21/2012
          ISN                      FCC            FCC-TLISN-T8-02                   20148                05/12/2012
    Current Probe                  FCC                     F-35                       506                07/05/2012
          ISN                      FCC            FCC-TLISN-T4-02                   20396                06/23/2012
       Test S/W                                                       EZ-EMC
NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
      2. N.C.R = No Calibration Request.




                                                            Page 11                                                 Rev.00
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                              Report No: T110714101-D



6.3. TEST PROCEDURES (please refer to measurement standard or CCS SOP PA-031)
Procedure of Preliminary Test
      The EUT and support equipment, if needed, were set up as per the test
    configuration to simulate typical usage per the user’s manual. When the EUT is a
    tabletop system, a wooden table with a height of 0.8 meters is used and is placed on
    the ground plane as per ANSI C63.4 (see Test Facility for the dimensions of the
    ground plane used). When the EUT is a floor standing equipment, it is placed on the
    ground plane, which has a 3-12 mm non-conductive covering to insulate the EUT
    from the ground plane.
       All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4.
      The test equipment EUT installed by AC 120VAC/60Hz main power, through a Line
    Impedance Stabilization Network (LISN), which was supplied power source and was
    grounded to the ground plane.
       All support equipment power by from a second LISN.
      The test program of the EUT was started. Emissions were measured on each
    current carrying line of the EUT using an EMI Test Receiver connected to the LISN
    powering the EUT.
     The Receiver scanned from 150kHz to 30MHz for emissions in each of the test
    modes.
       During the above scans, the emissions were maximized by cable manipulation.
       The test mode(s) described in Item 3.1 were scanned during the preliminary test.
      After the preliminary scan, we found the test mode described in Item 3.1 producing
    the highest emission level.
      The worst configuration of EUT and cable of the above highest emission level were
    recorded for reference of the final test.
Procedure of Final Test
     EUT and support equipment were set up on the test bench as per the configuration
    with highest emission level in the preliminary test.
      A scan was taken on both power lines, Line 1 and Line 2, recording at least the six
    highest emissions. Emission frequency and amplitude were recorded into a computer
    in which correction factors were used to calculate the emission level and compare
    reading to the applicable limit.
       The test data of the worst-case condition(s) was recorded.




                                                           Page 12                                                 Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                                   Report No: T110714101-D




6.4. TEST SETUP

                                                    Vert. reference plane

                                                                                                      EMI receiver




                        40cm
                                       EUT




                                                             80cm




               LISN
                                                                    Reference ground plane



       For the actual test configuration, please refer to the related item – Photographs of
     the Test Configuration.



6.5. DATA SAMPLE:
            QuasiPeak   Average   Correctrion   QuasiPeak     Average       QuasiPeak.   Average   QuasiPeak   Average
Frequency
             reading    reading     factor        result       result         limit       limit     margin     margin    Remark
  (MHz)
             (dBuV)     (dBuV)       (dB)        (dBuV)       (dBuV)         (dBuV)      (dBuV)      (dB)        (dB)

  x.xx       43.95      33.00       10.00        53.95        43.00          56.00       46.00      -2.05      -3.00     Pass

Frequency (MHz)                = Emission frequency in MHz
Reading (dBuV)                 = Uncorrected Analyzer/Receiver reading + Insertion loss of LISN, if it > 0.5 dB
Correction Factor (dB)         = LISN Factor + Cable Loss
Result (dBuV)                  = Raw reading converted to dBuV and CF added
Limit (dBuV)                   = Limit stated in standard
Margin (dB)                    = Result (dBuV) – Limit (dBuV)




                                                             Page 13                                                     Rev.00
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                                  Report No: T110714101-D


6.6. TEST RESULTS


Model No.                      55LV4400                             6dB Bandwidth               9 kHz
Environmental
                               25oC, 57% RH                         Test Mode                   Mode 1
Conditions
Tested by                      Kaily Chuang                         Line                        L1




                   QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average
NO. Frequency                                                                                                         Remark
                     reading    reading    factor      result     result     limit      limit    margin     margin

         (MHz)       (dBuV)     (dBuV)      (dB)      (dBuV)     (dBuV)     (dBuV)     (dBuV)      (dB)      (dB)    (Pass/Fail)

 1*      0.1773      40.40      37.70      9.70        50.10      47.40     64.61      54.61      -14.51     -7.21      Pass

 2       0.8961      14.31       9.01      9.19        23.50      18.20     56.00      46.00      -32.50    -27.80      Pass

 3       1.6773       0.03       0.03      9.17        9.20       9.20      56.00      46.00      -46.80    -36.80      Pass

 4       4.6148       2.30       0.00      9.50        11.80      9.50      56.00      46.00      -44.20    -36.50      Pass

 5       7.9000      15.04       6.14      9.86        24.90      16.00     60.00      50.00      -35.10    -34.00      Pass

 6      11.7867      19.03       5.13      10.27       29.30      15.40     60.00      50.00      -30.70    -34.60      Pass

REMARKS: L1 = Line One (Live Line)




                                                                Page 14                                                Rev.00
      This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                                  Report No: T110714101-D




Model No.                      55LV4400                             6dB Bandwidth               9 kHz
Environmental
                               25oC, 57% RH                         Test Mode                   Mode 1
Conditions
Tested by                      Kaily Chuang                         Line                        L2




                   QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average
NO. Frequency                                                                                                         Remark
                     reading    reading    factor      result     result     limit      limit    margin     margin

         (MHz)       (dBuV)     (dBuV)      (dB)      (dBuV)     (dBuV)     (dBuV)     (dBuV)      (dB)      (dB)    (Pass/Fail)

 1*      0.1773      39.99      36.79      9.71        49.70      46.50     64.61      54.61      -14.91     -8.11      Pass

 2       0.5328      19.59      14.09      9.61        29.20      23.70     56.00      46.00      -26.80    -22.30      Pass

 3       0.8844      16.38       9.08      9.62        26.00      18.70     56.00      46.00      -30.00    -27.30      Pass

 4       1.2398      14.76       7.66      9.64        24.40      17.30     56.00      46.00      -31.60    -28.70      Pass

 5       8.2711      15.19       4.89      10.01       25.20      14.90     60.00      50.00      -34.80    -35.10      Pass

 6      12.0289      17.37       3.37      10.23       27.60      13.60     60.00      50.00      -32.40    -36.40      Pass

REMARKS: L2 = Line Two (Neutral Line)




                                                                Page 15                                                Rev.00
      This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                               Report No: T110714101-D


7 RADIATED EMISSION MEASUREMENT
7.1. LIMITS OF RADIATED EMISSION MEASUREMENT
          FREQUENCY (MHz)                                                  dBuV/m (At 10m)
                                                                Class A                              Class B
                    30 ~ 230                                        40                                   30
                   230 ~ 1000                                       47                                   37


        Frequency                   Class A (dBuV/m) (At 3m)                      Class B (dBuV/m) (At 3m)
          (MHZ)                       Average                  Peak                Average                    Peak
       Above 1000                         60                     80                    54                      74
NOTE: (1) The lower limit shall apply at the transition frequencies.
       (2) Emission level (dBuV/m) = 20 log Emission level (uV/m).

According to FCC Part 15.33 (b), for an unintentional radiator, including a digital device, the spectrum shall
be investigated from the lowest radio frequency signal generated or used in the device, without going below
the lowest frequency for which a radiated emission limit is specified, up to the frequency shown in the
following table:
Highest frequency generated or used in the device                     Upper frequency of measurement range
or in which the device operated or tunes (MHz)                                              (MHz)
                         Below 1.75                                                           30
                          1.75-108                                                          1000
                           108-500                                                          2000
                          500-1000                                                          5000
                                                                   5th harmonic of the highest frequency or 40GHz,
                         Above 1000
                                                                                  whichever is lower




                                                            Page 16                                                 Rev.00
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                               Report No: T110714101-D


7.2. TEST INSTRUMENTS
                                            Open Area Test Site # 1
Name of Equipment Manufacturer                           Model               Serial Number           Calibration Due
  Spectrum Analyzer           ADVANTEST                 R3261C                  81720301                    N.C.R
  EMI Test Receiver                R&S                  ESVS20                 838804/004                03/28/2012
     Pre-Amplifier                  HP                   8447D                 2944A09173                04/13/2012
    Bilog Antenna            SCHAFFNER                CBL 6112D                    23189                 10/06/2011
      Turn Table                   CCS                  CC-T-1F                     N/A                     N.C.R
    Antenna Tower                  CCS                  CC-A-1F                     N/A                     N.C.R
       Controller                  CCS                  CC-C-1F                     N/A                     N.C.R
      RF Switch                   Anritsu                MP59B                    M54367                    N.C.R
       Test S/W                                   LabVIEW 6.1 (CCS OATS EMI SW V2.7)

                                                 3 Meter Chamber
 Name of Equipment             Manufacturer                  Model              Serial Number Calibration Due
  Spectrum Analyzer                 Agilent                 E4446A               MY48250064              12/29/2011
     Pre-Amplifier                    HP                  8449B                  3008A00965              04/17/2012
                                                     AMF-6F-260400-40
     Pre-Amplifier                  MITEQ                                            985646              05/23/2012
                                                            -8P
     Horn Antenna                   EMCO                   3115                   9602-4659              05/09/2012
     Horn Antenna                   EMCO                      3116                 00026370              10/12/2011
   Low Loss Cable              Huber+Suhner                 104PEA               24815/4PEA              08/13/2011
   Low Loss Cable              Huber+Suhner                 104PEA               30956/4PEA              04/17/2012
      Turn Table                     CCS                    CC-T-1F                    N/A                   N.C.R
    Antenna Tower                    CCS                    CC-A-1F                    N/A                   N.C.R
     Controller                      CCS                   CC-C-1F                     N/A                   N.C.R
 Bore-Sight Antenna
                                     CCS             CCS-BORESIGHT                     001                   N.C.R
       Tower
      Test S/W                                                      CCS-3A1RE
NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
      2. N.C.R = No Calibration Request.




                                                            Page 17                                                 Rev.00
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                              Report No: T110714101-D




7.3. TEST PROCEDURES (please refer to measurement standard or CCS SOP PA-031)
Procedure of Preliminary Test
       The equipment was set up as per the test configuration to simulate typical usage
    per the user’s manual. When the EUT is a tabletop system, a wooden turntable with a
    height of 0.8 meters is used which is placed on the ground plane. When the EUT is a
    floor standing equipment, it is placed on the ground plane which has a 3-12 mm
    non-conductive covering to insulate the EUT from the ground plane.
       Support equipment, if needed, was placed as per ANSI C63.4.
       All I/O cables were positioned to simulate typical usage as per ANSI C63.4.
      The EUT received AC power source from the outlet socket under the turntable. All
    support equipment power received from another socket under the turntable.
      The antenna was placed at 3 or 10 meter away from the EUT as stated in ANSI
    C63.4. The antenna connected to the Spectrum Analyzer via a cable and at times a
    pre-amplifier would be used.
      The Analyzer / Receiver quickly scanned from 30MHz to 40GHz. The EUT test
    program was started. Emissions were scanned and measured rotating the EUT to
    360 degrees and positioning the antenna 1 to 4 meters (For Below 1GHz) or 1 meter
    (For Above 1GHz) above the ground plane, in both the vertical and the horizontal
    polarization, to maximize the emission reading level.
       The test mode(s) described in Item 3.1 were scanned during the preliminary test:
      After the preliminary scan, we found the test mode described in Item 3.1 producing
    the highest emission level.
      The worst configuration of EUT and cable of the above highest emission level were
    recorded for reference of the final test.
Procedure of Final Test
     EUT and support equipment were set up on the turntable as per the configuration
    with highest emission level in the preliminary test.
     The Analyzer / Receiver scanned from 30MHz to 40GHz. Emissions were scanned
    and measured rotating the EUT to 360 degrees, varying cable placement and
    positioning the antenna 1 or 1 to 4 meters above the ground plane, in both the vertical
    and the horizontal polarization, to maximize the emission reading level.
      Recording at least the six highest emissions. Emission frequency, amplitude,
    antenna position, polarization and turntable position were recorded into a computer in
    which correction factors were used to calculate the emission level and compare
    reading to the applicable limit and Q.P. (For Below 1GHz) or Peak/Average (For
    Above 1GHz) reading is presented.
       The test data of the worst-case condition(s) was recorded.


                                                           Page 18                                                 Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                              Report No: T110714101-D




7.4. TEST SETUP
Below 1GHz




                                              Test table &
                                              Turntable
                                                                                                    1m ~ 4m
                                Boundary of
                                   EUT
                                                                            Coaxial
                                                                            Cable
     Power                                             0.8 m
     Cable


                                                             3 or 10 m
                                                                                                  Ground Plane
                Filter                 To Power
                                                                                              EMI
                                                                                            Receiver


Above 1GHz


                                                                               Antenna
                                                                                tower



                          3m                                                   Horn
                                                                              antenna
   EUT
                                 4m
                                                                                Spectrum
                                                                                analyzer



         Turntable
                         0.8m         1-4m
                                                30cm
                                                                                  Pre-amp
                     ▲▲▲▲▲▲▲▲



      For the actual test configuration, please refer to the related item – Photographs of
    the Test Configuration.




                                                               Page 19                                             Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                                Report No: T110714101-D

7.5. DATA SAMPLE:
Below 1GHz
                          Correction
Frequency Reading                             Result          Limit         Margin       Degree       Height
                           Factor                                                                                 Remark
  (MHz)   (dBuV)                            (dBuV/m)        (dBuV/m)         (dB)         (。)          (cm)
                           (dB/m)

  xx.xx        16.49          9.86            26.35           30.00          -3.65       116.00       101.00         QP

Above 1GHz
Frequency     Reading        Correct         Result         Limit        Margin        Height        Degree        Remark

  (MHz)       (dBuV/m)      Factor(dB)     (dBuV/m)       (dBuV/m)         (dB)         (cm)           ( ° )

   XX           54.08         -11.80         42.28          74.00        -27.72          100           185          peak
   XX           34.80         -11.80         23.00          54.00        -27.00          100           185          AVG

Frequency (MHz)                      = Emission frequency in MHz
Reading (dBuV)                       = Uncorrected Analyzer / Receiver reading
Correction Factor (dB/m)             = Antenna factor + Cable loss – Amplifier gain
Result (dBuV/m)                      = Reading (dBuV) + Corr. Factor (dB/m)
Limit (dBuV/m)                       = Limit stated in standard
Margin (dB)                          = Result (dBuV/m) – Limit (dBuV/m)
Q.P.                                 = Quasi-Peak




                                                            Page 20                                                 Rev.00
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                                 Report No: T110714101-D


7.6. TEST RESULTS
Below 1GHz

Model No.                  55LV4400                                 Test Mode                 Mode 1
Environmental
                           25oC, 56% RH                             6dB Bandwidth             120 kHz
Conditions
Antenna Pole               Vertical                                 Antenna Distance 10m

Detector Function: Quasi-peak.                                      Tested by                 Gordon Lai




 No.    Frequency       Reading       Correction      Result        Limit      Margin       Degree       Height      Remark
           (MHz)        (dBuV)      Factor(dB/m) (dBuV/m) (dBuV/m)               (dB)          (°)        (cm)
 1         119.10        37.66          -11.34        26.32        30.00        -3.68        23.50       100.00         QP
 2        133.49         36.25          -11.53        24.72        30.00        -5.28       163.90       100.00         QP
 3        148.01         38.66          -12.06        26.60        30.00        -3.40       249.50       100.00         QP
 4        153.68         37.69          -12.37        25.32        30.00        -4.68        72.40       100.00         QP
 5        192.32         38.70          -13.30        25.40        30.00        -4.60       294.90       100.00         QP
 6        223.96         37.27          -12.22        25.05        30.00        -4.95        38.80       100.00         QP
 7        297.50         32.81          -8.26         24.55        37.00        -12.45      297.80       400.00         QP
 8        375.30         29.46          -5.86         23.60        37.00        -13.40      356.50       200.00         QP
 9        491.90         29.82          -3.27         26.55        37.00        -10.45      357.60       140.00         QP
 10       602.70         32.17          -0.35         31.82        37.00        -5.18        87.70       120.10         QP
REMARKS:            The other emission levels were very low against the limit.




                                                               Page 21                                                Rev.00
     This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                                 Report No: T110714101-D




Model No.                  55LV4400                                 Test Mode                 Mode 1
Environmental
                           25oC, 56% RH                             6dB Bandwidth             120 kHz
Conditions
Antenna Pole               Horizontal                               Antenna Distance 10m

Detector Function: Quasi-peak.                                      Tested by                 Gordon Lai




 No.    Frequency       Reading      Correction       Result        Limit      Margin       Degree       Height      Remark
           (MHz)        (dBuV)      Factor(dB/m) (dBuV/m) (dBuV/m)               (dB)          (°)        (cm)
 1         119.24        36.08          -11.33        24.75        30.00        -5.25       184.30       400.00         QP
 2        133.27         32.27          -11.52        20.75        30.00        -9.25       212.80       400.00         QP
 3        149.27         36.90          -12.13        24.77        30.00        -5.23       159.70       400.00         QP
 4        160.14         35.56          -12.71        22.85        30.00        -7.15       162.20       400.00         QP
 5        188.50         34.59          -13.37        21.22        30.00        -8.78         1.40       400.00         QP
 6        223.10         36.45          -12.25        24.20        30.00        -5.80       217.60       400.00         QP
 7        297.50         32.73          -8.26         24.47        37.00        -12.53      290.10       400.00         QP
 8        381.40         29.37          -5.70         23.67        37.00        -13.33       61.30       299.80         QP
 9        596.70         29.97          -0.45         29.52        37.00        -7.48       294.60       129.80         QP
REMARKS:            The other emission levels were very low against the limit.




                                                               Page 22                                                Rev.00
     This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                              Report No: T110714101-D



Above 1GHz
Model No.               55LV4400                            Test Mode                    Mode 1
Environmental
                        18oC, 60% RH                        Upper frequency              6000MHz
Conditions
Antenna Pole            Vertical                            Antenna Distance             3m

Detector Function: Peak/Average                             Tested By                    Rick Lu


 No.   Frequency       Reading        Correct        Result         Limit       Margin     Height      Degree     Remark

         (MHz)        (dBuV/m)      Factor(dB)      (dBuV/m)      (dBuV/m)       (dB)         (cm)      ( ° )

  1    1575.000         64.27          -8.44          55.83         74.00       -18.17        125        162        peak
  2    1575.000         42.13          -8.44          33.69         54.00       -20.31        125        162        AVG
  3    1866.667         67.94          -6.86          61.08         74.00       -12.92        118        176        peak
  4    1866.667         52.28          -6.86          45.42         54.00        -8.58        118        176        AVG
  5    2791.667         65.22          -3.61          61.61         74.00       -12.39        105        213        peak
  6    2791.667         47.36          -3.61          43.75         54.00       -10.25        105        213        AVG
  7    3108.333         60.28          -2.49          57.79         74.00       -16.21        110        221        peak
  8    3108.333         41.89          -2.49          39.40         54.00       -14.60        110        221        AVG
  9    3416.667         61.01          -1.68          59.33         74.00       -14.67        122        148        peak
 10    3416.667         44.69          -1.68          43.01         54.00       -10.99        122        148        AVG
 11    4033.333         56.18           1.07          57.25         74.00       -16.75        130        222        peak
 12    4033.333         36.96           1.07          38.03         54.00       -15.97        130        222        AVG
 13    4350.000         54.96           1.60          56.56         74.00       -17.44        130        164        peak
 14    4350.000         39.81           1.60          41.41         54.00       -12.59        130        164        AVG


REMARKS:         1. The other emission levels were very low against the limit.
                 2. “--”, means the average measurement was not performed when the measured peak data
                   under the limit of average detection.




                                                           Page 23                                                 Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                              Report No: T110714101-D




Model No.               55LV4400                            Test Mode                    Mode 1
Environmental
                        18oC, 60% RH                        Upper frequency              6000MHz
Conditions
Antenna Pole            Horizontal                          Antenna Distance             3m

Detector Function: Peak/Average                             Tested By                    Rick Lu


 No.   Frequency       Reading        Correct        Result         Limit       Margin     Height      Degree     Remark

         (MHz)        (dBuV/m)      Factor(dB)      (dBuV/m)      (dBuV/m)       (dB)         (cm)      ( ° )

  1    1866.667         70.64          -6.86          63.78         74.00       -10.22        124        186        peak
  2    1866.667         57.69          -6.86          50.83         54.00        -3.17        124        186        AVG
  3    2175.000         63.51          -5.66          57.85         74.00       -16.15        118        189        peak
  4    2175.000         42.36          -5.66          36.70         54.00       -17.30        118        189        AVG
  5    2791.667         61.74          -3.61          58.13         74.00       -15.87        125        174        peak
  6    2791.667         43.58          -3.61          39.97         54.00       -14.03        125        174        AVG
  7    2900.000         58.17          -3.18          54.99         74.00       -19.01        115        220        peak
  8    2900.000         39.14          -3.18          35.96         54.00       -18.04        115        220        AVG
  9    3108.333         69.18          -2.49          66.69         74.00        -7.31        132        213        peak
 10    3108.333         53.45          -2.49          50.96         54.00        -3.04        132        213        AVG
 11    3416.667         64.80          -1.68          63.12         74.00       -10.88        122        216        peak
 12    3416.667         45.02          -1.68          43.34         54.00       -10.66        122        216        AVG
 13    4350.000         53.56           1.60          55.16         74.00       -18.84        105        220        peak
 14    4350.000         39.89           1.60          41.49         54.00       -12.51        105        220        AVG


REMARKS:         1. The other emission levels were very low against the limit.
                 2. “--”, means the average measurement was not performed when the measured peak data
                   under the limit of average detection.




                                                           Page 24                                                 Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                              Report No: T110714101-D


APPENDIX 1: PHOTOGRAPHS OF EUT
Refer to T110714101 External Photographs.




                                                           Page 28                                                 Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.



Document Created: 2011-08-10 15:57:21
Document Modified: 2011-08-10 15:57:21

© 2024 FCC.report