RF Exposure Report (MPE)

FCC ID: MCQ-CCIMX6UL

RF Exposure Info

Download: PDF
FCCID_4224749

MPE/RF EXPOSURE EVALUATION REPORT
                                FROM




 Evaluation of: Digi International ConnectCore i.MX6UL
                                  to
 To: FCC CFR 47 Part 15 RF Exposure Requirements
    Test Report Serial No.: DIGI79-U2 MPE Rev A
              This report supersedes: NONE
                    Applicant:         Digi International Inc.
                                       11001 Bren Road East
                                       Minnetonka, MN 55343
                                       USA
         Product Function:             Embedded ARM Module.
                  Issue Date:          14th December 2018

    This Test Report is Issued Under the Authority of:

        MiCOM Labs, Inc.
        575 Boulder Court
        Pleasanton California 94566
        USA
        Phone: +1 (925) 462-0304
        Fax: +1 (925) 462-0306
        www.micomlabs.com

    MiCOM Labs is an ISO 17025 Accredited Testing Laboratory


                                                                        Title:       Digi International ConnectCore i.MX6UL
                                                                          To:        FCC CFR 47 Part 1.1310
                                                                     Serial #:       DIGI79-U2 Rev A FCC MPE
                                                                                       th
                                                                  Issue Date:        14 December 2018
                                                                       Page:         2 of 4



1. MAXIMUM PERMISSABLE EXPOSURE
Calculations for Maximum Permissible Exposure Levels
                             2           2
Power Density = Pd (mW/cm ) = EIRP/(4*π*d )
EIRP = P * G
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)

Because the EUT belongs to the General Population/Uncontrolled Exposure the limit of power density is 1
      2
mW/cm

These calculations represent worst case in terms of the exposure levels for the device operating in the
5000 MHz band.
                                                                     Calculated
                Frequency                       Peak       Peak                     Power
                              Ant   Numeric                            Power                Min Calculated
  Freq. Band        of                         Output     Output                   Density
                             Gain     Gain                            Density                 safe distance
    (MHz)       Calculation                    Power      Power                     Limit
                             (dBi) (numeric)                        (mW/cm2) @               for Limit (cm)
                  (MHz)                        (dBm)       (mW)                   (mW/cm2)
                                                                       20cm
  4900-5900       5240        5.5    3.55       11.4      13.80       0.010          1.0          1.97


Note: for mobile or fixed location transmitters the minimum separation distance is 20cm, even if
calculations indicate the MPE distance to be less.




Specification
Maximum Permissible Exposure Limits



                                       2
FCC §1.1310 Limit = 1 mW/cm from 1.310 Table 1 for devices operating in the 5000 MHz band




              This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.

  MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


                                                                        Title:       Digi International ConnectCore i.MX6UL
                                                                          To:        FCC CFR 47 Part 1.1310
                                                                     Serial #:       DIGI79-U2 Rev A FCC MPE
                                                                                       th
                                                                  Issue Date:        14 December 2018
                                                                       Page:         3 of 4




Specification - Maximum Permissible Exposure Limits

                            TABLE 1—LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
 Frequency range           Electric field strength         Magnetic field strength          Power density        Averaging time
      (MHz)                         (V/m)                          (A/m)                      (mW/cm2)             (minutes)

                                      (A) Limits for Occupational/Controlled Exposure

      0.3-3.0                       614                              1.63                        *100                    6
                                                                                                        2
      3.0-30                       1842/f                           4.89/f                     *900/f                    6
      30-300                        61.4                            0.163                         1.0                    6
    300-1,500                         --                               --                       f/300                    6
 1,500-100,000                        --                               --                          5                     6
                                 (B) Limits for General Population/Uncontrolled Exposure

     0.3-1.34                       614                              1.63                        *100                   30
                                                                                                        2
     1.34-30                        824/f                           2.19/f                     *180/f                   30
      30-300                        27.5                            0.073                         0.2                   30
    300-1,500                         --                               --                       f/1500                  30
 1,500-100,000                        --                               --                         1.0                   30

                                      f = frequency in MHz * = Plane-wave equivalent power density




              This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                         personnel. All changes will be noted in the Document History section of the report.

  MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


       575 Boulder Court
Pleasanton, California 94566, USA
     Tel: +1 (925) 462 0304
     Fax: +1 (925) 462 0306
      www.micomlabs.com



Document Created: 2019-04-07 14:40:46
Document Modified: 2019-04-07 14:40:46

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC