Large Panel 2

FCC ID: M5VG031404

Test Report

Download: PDF
FCCID_843426

                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007




                                                            TEST REPORT
                          Gallagher BR1300 Animal EID Panel Reader
                                  with Large Panel Antenna
                                                                                tested to

                                             47 Code of Federal Regulations

                                        Part 15 - Radio Frequency Devices

                                         Subpart C – Intentional Radiators

                                                                                     for

                                                          Gallagher Group Ltd




     This Test Report is issued with the authority of:
                                                                                                    ______________________________________
                                                                                                         Andrew Cutler - General Manager




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 1 of 23                This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007




                                                         Table of Contents


1.         STATEMENT OF COMPLIANCE                                                                                                                                                    3

2.         RESULTS SUMMARY                                                                                                                                                            3

3.         INTRODUCTION                                                                                                                                                               4

4.         CLIENT INFORMATION                                                                                                                                                         4

5.         DESCRIPTION OF TEST SAMPLE                                                                                                                                                 5

6.         RESULTS                                                                                                                                                                    6

7.         TEST EQUIPMENT USED                                                                                                                                                       18

8.         ACCREDITATIONS                                                                                                                                                            18

9.         PHOTOGRAPH (S)                                                                                                                                                            19




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 2 of 23                This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


1.            STATEMENT OF COMPLIANCE
              The Gallagher BR600 Animal EID Panel Reader with Large Panel Antenna
              complies with FCC Part 15 Subpart C as an Intentional Radiator when the methods,
              as described in ANSI C63.4 - 2003, are applied.



2.            RESULTS SUMMARY
                Clause                   Parameter                                                      Result
                15.201                   Equipment authorisation                                        Certification required.
                                         requirement
                15.203                   Antenna requirement                                            Complies.                Antenna               connector
                                                                                                        unique.

                15.204                   External PA and antenna Not applicable.                                                               No          external
                                         modifications           devices.

                15.205                   Restricted bands of operation                                  Complies. Device transmits on
                                                                                                        134.2 kHz.

                15.207                   Conducted limits                                               Complies with a 15.7 dB margin
                                                                                                        at 190 kHz (Average)

                15.209                   Radiated emission limits -                                     Complies with an 0.4 dB margin
                                         Fundamental                                                    when extrapolated to 300 metres.

                15.209                   Radiated emission limits -                                     Complies with a 20.3 dB margin
                                         Spurious emissions <30 MHz                                     at 671 kHz.

                15.209                   Radiated emission limits –                                     Complies with a 6.0 dB margin at
                                         Spurious emissions >30 MHz                                     43.053 MHz (Vertical) in charge
                                                                                                        mode.




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 3 of 23                This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


3.            INTRODUCTION
              This report describes the tests and measurements performed for the purpose of
              determining compliance with the specification.

              The client selected the test sample.

              This report relates only to the sample tested.

              This report contains no corrections or erasures.

              Measurement uncertainties with statistical confidence intervals of 95% are shown
              below test results. Both Class A and Class B uncertainties have been accounted for,
              as well as influence uncertainties where appropriate.

              NB: This report replaces report number 70626.2 in order to address a number of
              issues raised by the TCB in relation to the certification of this device


4.            CLIENT INFORMATION


              Company Name                                             Gallagher Group Ltd

              Address                                                  Private Bag 3026

              City                                                     Hamilton

              Country                                                  New Zealand

              Contact                                                  Mr Murray Long




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 4 of 23                This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007



5.            DESCRIPTION OF TEST SAMPLE

              Brand Name                                               Gallagher

              Model Number                                             BR600 RFID Panel Reader

              Product                                                  Animal EID Panel Reader with Large Panel Antenna

              Manufacturer                                             Gallagher Group Ltd

              Country of Origin                                        New Zealand

              Serial Number                                            Not serialised

              FCC ID                                                   Not yet determined

              Ancillary Equipment

              - Gallagher Weighscale 700 Animal weighing scale. Device not serialised.

              - FranMar FDF0503-C Switch Mode Power Supply / Battery Charger. Device not
              serialised




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 5 of 23                This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007



6.            RESULTS
              Standard

              The sample was tested in accordance with 47 CFR Part 15 Subpart C.

              Methods and Procedures

              The measurement methods and procedures as described in ANSI C63.4 - 2003 were
              used.

              Section 15.201: Equipment authorisation requirement

              Certification as detailed in Subpart J of Part 2 is required for this device.

              Section 15.203: Antenna requirement

              As can be seen from the attached photographs the device has an internal unique
              connector. The connector type is a Hirschmann CA series part number 932-325-100
              connector.

              Result: Complies.

              Section 15.204: External radio frequency power amplifiers and antenna
              modifications

              From the attached photographs it can be seen that it is not possible to attach an
              external power amplifier to this transmitter.

              Result: Complies.

              Section 15.205: Restricted bands of operation

              The transmitter transmits on 134.2 kHz.

              This falls between the restricted bands of 90 –110 kHz and 495 – 505 kHz.

              Result: Complies.


__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 6 of 23                This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


              Section 15.207: Conducted limits

              Conducted emission testing has been carried out as the device has provisions to allow
              charging of the internal batteries using a 110 Vac charger.

              Testing has been carried out using a representative 110 Vac charger.

              When the device is being charged the transmitter is deactivated and tags cannot be read.

              No provision has been made for the transmitter to operate using an external 110 Vac
              supply with the only provision being made for external and internal battery operations.

              Conducted emissions testing was carried out over the frequency range of 150 kHz
              to 30 MHz at the Laboratory’s MacKelvie Street premises in a 2.4 m x 2.4 m x 2.4
              m screened room.

              Measurements on both the phase and neutral lines were made using either a Quasi
              Peak or an Average detector with a 9 kHz bandwidth.

              The supplied conducted emission plot is a combined plot showing the worst case of
              the Peak, Quasi Peak and Average levels for both phase and neutral.


              Result: Complies with a 15.7 dB margin at 0.190 MHz (Average).

              Measurement uncertainty with a confidence interval of 95% is:
                        - Mains terminal tests        (0.15 - 30 MHz) ± 2.2 dB




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 7 of 23                This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


                                                                        Conducted emissions

    Comments:                 Device tested when powered at 110 Vac charging the transmitter internal batteries with a
                              sample antenna attached.

         Level [dBµV]
        80




        60


                    x
        40          +


                                                                                                            +
        20                                                                                                    +
                                                                                                            xxx

                                                                                                                                               +

           0




      -20
               150k           300k          500k                   1M      2M   3M 4M                                  6M            10M                         30M
                                                                    Frequency [Hz]

           Peak -------                   Average -------                    Quasi Peak        X                      Average +
Quasi-Peak Measurements
      Frequency                            Level                     Limit                     Margin                      Phase                   Rechecks
         MHz                               dBµV                      dBµV                       dB                                                  dBµV
      0.190000                             47.50                     64.0                      16.5                           N
      3.980000                             18.50                     56.0                      37.5                           N
      4.040000                             19.40                     56.0                      36.6                           N
      4.170000                             17.70                     56.0                      38.3                           N
Average Measurements
           Frequency                       Level                     Limit                     Margin                      Phase                   Rechecks
               MHz                         dBµV                      dBµV                       dB                                                  dBµV
            0.190000                       38.30                     54.0                      15.7                         N                        37.5
            4.030000                       25.50                     46.0                      20.5                         L1
            4.220000                       19.80                     46.0                      26.2                         L1
           13.120000                       10.40                     50.0                      39.6                         N
__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                       Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                          E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                   Web Site: www.emctech.com.au
Page 8 of 23                This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


              Section 15.209: Radiated emission limits, general requirements

              Radiated emissions testing was carried out over the frequency range of 100 kHz to
              1000 MHz.

              Testing was carried out at the laboratory’s open area test site - located at Driving
              Creek, Orere Point, Auckland, New Zealand.

              This site conforms to the requirements of CISPR 16, Part 1, Clause 16, and ANSI
              C63.4 - 2003.

              The device was placed on the test tabletop, which is a total of 0.8 m above the test site
              ground plane.

              Testing below 30 MHz was carried out with a large antenna panel attached and testing
              above 30 MHz was carried out with a small panel attached.

              When an emission is located, it is positively identified and its maximum level is
              found by rotating the automated turntable, and by varying the antenna height, where
              appropriate, with an automated antenna tower.

              The emission is measured in both vertical and horizontal antenna polarisations,
              where appropriate.

              The emission level was determined in field strength by taking the following into
              consideration:

                            Level (dBµV/m) = Receiver Reading (dBµV) + Antenna Factor (dB) +
                            Coax Loss (dB)




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 9 of 23                This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


              Fundamental emission:

              Measurements were made using a magnetic loop antenna and a receiver with an average
              detector and a peak detector both using a 9 kHz bandwidth

              Measurements were initially made at a distance of 10 metres then also at 30 metres.

              Using these measurements a 300 metre extrapolated level has been determined as
              detailed in section 15.31(f)(2) as measurements were made at two distances on the radial
              that was determined to give the highest field strength.

              The highest radial was determined during the pre screening of the device when it was
              rotated on the test site using a turntable.

              At this point the measurement antenna was then further adjusted to give the highest field
              strength.

              The maximum field strength was found to be where the transmitting antenna was facing
              the measurement antenna (see attached diagram).

              Measurements were made while the device was being powered at 12 Vdc using an
              external battery that was fully charged.

              Testing was carried out with a large antenna panel attached.

              Previous testing had shown that this power configuration gave the highest field strength.

       Frequency                      Average Level                             Limit                               Margin                            Distance
         (kHz)                         (dBuV/m)                               (dBuV/m)                               (dB)
        134.200                           100.5                                  85.0                                15.5                            10 metres
        134.200                           76.0                                   65.0                                11.0                            30 metres
        134.200                           21.4                                   25.0                                -3.6                           300 metres

       Frequency                           Peak Level                           Limit                               Margin                            Distance
         (kHz)                             (dBuV/m)                           (dBuV/m)                               (dB)
        134.200                              107.1                                -                                    -                             10 metres
        134.200                               82.6                                -                                        -                        30 metres
        134.200                               31.2                               45.0                                 -13.8                         300 metres

              The peak limit is the average limit plus 20 dB
__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 10 of 23               This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


              Sample Calculation (Average detector):
              10 metre to 30 metre roll off = 24.5 dB
              10 metres to 30 metres is 0.477 of a decade
              30 metres to 300 metres is 1 decade.
              Therefore 10 metres to 300 metres is 1.477 of a decade
              10 metres to 300 metres roll off is 24.5 dB x (1.477 / 0.477) = 75.9 dB
              10 metre measurement 100.5 dBuV/m – 75.9 dB = 24.6 dBuV/m at 300 metres

              Highest field strength test set up diagram and photos.




              Result: Complies with a 0.6 dB margin when measured using an average detector.

              Measurement uncertainty with a confidence interval of 95% is:
              - Free radiation tests      (100 kHz – 30 MHz) ± 4.8 dB
__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 11 of 23               This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


              Section 15.209: Spurious Emissions (below 30 MHz)

                       Frequency                          Level                     Limit                      Margin                      Result                  Detector
                          kHz                            dBuV/m                    dBuV/m                       dB
                        268.400                            48.4                      79.0                      -30.6                         Pass                 Average
                        268.400                            58.7                      99.0                      -40.3                         Pass                  Peak
                        402.600                            55.0                      75.5                      -20.5                         Pass                 Average
                        402.600                            62.8                      95.5                      -32.7                         Pass                  Peak
                        536.800                             -                        53.0                        -                           Pass                Quasi Peak
                        671.000                            30.8                      51.1                      -20.3                         Pass                Quasi Peak
                        805.200                             -                        49.5                        -                           Pass                Quasi Peak
                        939.400                             -                        48.1                        -                           Pass                Quasi Peak
                       1073.600                             -                        49.5                        -                           Pass                Quasi Peak
                       1207.800                             -                        49.5                        -                           Pass                Quasi Peak
                       1342.000                             -                        49.5                        -                           Pass                Quasi Peak

              No other emissions detected from the transmitter that were within 20 dB of the
              applicable limit.

              Magnetic loop measurements were made at a distance of 10metres.

              Pre screening of the device of the device was carried on the test site using a turntable
              which showed that the maximum field strength of the spurious emissions was in the
              same radial as for the fundamental emission (see fundamental test set up diagram).

              At each frequency the measurement antenna was further adjusted to give the highest
              field strength.

              Measurements were made while the device was being powered using an external 12 Vdc
              battery that was fully charged.

              Testing was carried out with a large antenna panel attached.

              A receiver with an average detector and a peak detector using a 9 kHz bandwidth was
              used between 110 – 490 kHz and a quasi peak detector with a 9 kHz bandwidth was
              used between 490 kHz – 30.0 MHz.




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 12 of 23               This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


              The 300 metre limit between 125 – 490 kHz has been scaled by a factor of 40 dB per
              decade, as per section 15.31 (f) (2) and the 30 metre limit between 490 – 1705 kHz has
              been scaled by a factor of 40 dB per decade, as per section 15.31 (f) (2).

              The limit between 110 – 490 kHz was increased by 20 dB when the peak detector was
              used.

              The spurious emissions observed do not exceed the level of the fundament emission.

              Result: Complies with a margin of 20.3 dB at 671 kHz.

              Measurement uncertainty with a confidence interval of 95% is:
              - Free radiation tests      (100 kHz – 30 MHz) ± 4.8 dB




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 13 of 23               This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


              Section 15.209: Spurious Emissions (above 30 MHz)

              Measurements between 30 –1000 MHz have been made at a distance of 3 metres.

              Measurements were made while the device was being powered using an external 12 Vdc
              battery that was fully charged.

              A receiver with a quasi peak detector with a 120 kHz bandwidth was used between 30 –
              1000 MHz.

              Measurements were carried out as the device contains several digital devices.

              Attached to the serial port of the device was a weighing instrument that was located
              approximately 10 metres away that was provided to load this port.

              Data was sent to the weighing instrument using a one way link as this is how the device
              would typically be used.

              The weighing instrument was not powered as pre-screening showed that this mode gave
              the worst case levels.

              The transmitter used can operate with either a small or larger antenna attached.

              Testing was carried out with the small antenna attached as previous pre-compliance
              testing had shown that emissions above 30 MHz were coming from the various digital
              devices contained within the product with the observed emission levels not being
              influenced by the type of antenna used which is designed to operate at 134 kHz.

              The limits as described in Section 15.209 have been applied as follows:

              30.0 – 88.0 MHz                            100 uV/m                     40 dBuV/m
              88.0 – 216.0 MHz                           150 uV/m                     43.5 dBuV/m
              216.9 – 960.0 MHz                          200 uV/m                     46.0 dBuV/m


              Result: Complies with an 6.0 dB margin at 43.053 MHz (Vertical) when operating in
              charge mode.

              Measurement uncertainty with a confidence interval of 95% is:
                    - Free radiation tests       (30 – 1000 MHz) ± 4.1 dB

__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 14 of 23               This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


        Spurious Emissions

        Device tested when being powered using an external 12 Vdc battery.

          Frequency                       Level      Recheck Limit Margin Result Worst Case
                                   Vertical    Hort                               Antenna
              MHz                  dBuV/m dBuV/m dBuV/m dBuV/m       dB
             34.353                  20.2                    40.0   19.8   Pass    Vertical
             68.708                  17.0                    40.0   23.0   Pass    Vertical
             85.880                  19.7                    43.5   23.8   Pass    Vertical
             103.063                 20.3                    43.5   23.2   Pass    Vertical
             120.238                 18.4                    43.5   25.1   Pass    Vertical
             137.415                 28.0                    43.5   15.5   Pass    Vertical
             154.593                 24.3       25.6         43.5   17.9   Pass   Horizontal
             174.058                 25.2                    43.5   18.3   Pass    Vertical
             188.950                 29.7                    43.5   13.8   Pass    Vertical
             189.940                 25.5                    43.5   18.0   Pass    Vertical
             202.150                            33.8         43.5    9.7   Pass   Horizontal
             206.120                 22.5                    43.5   21.0   Pass    Vertical
             274.828                 31.2       36.5         46.0   9.5    Pass   Horizontal
             292.010                 21.5       29.6         46.0   16.4   Pass   Horizontal
             300.090                            31.5         46.0   14.5   Pass   Horizontal
             326.354                 26.5       33.5         46.0   12.5   Pass   Horizontal
             343.534                 32.1       38.3  38.3   46.0    7.7   Pass   Horizontal
             412.243                 34.6       35.3         46.0   10.7   Pass   Horizontal
             429.419                 26.7                    46.0   19.3   Pass    Vertical
             472.363                            31.0         46.0   15.0   Pass   Horizontal
             480.950                 26.1       34.0         46.0   12.0   Pass   Horizontal
             489.540                 32.0       31.2         46.0   14.0   Pass    Vertical
             498.128                 31.0       32.6         46.0   13.4   Pass   Horizontal
             755.781                 30.2                    46.0   15.8   Pass    Vertical
             824.488                 32.7                    46.0   13.3   Pass    Vertical


        No further emissions detected within 20 dB of the applicable limit.




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 15 of 23               This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


        Device operating in charge mode when powered using a 110 Vac charger

          Frequency                       Level      Recheck Limit Margin Result Worst Case
                                   Vertical    Hort                               Antenna
              MHz                  dBuV/m dBuV/m dBuV/m dBuV/m       dB
             34.353                  26.4                    40.0   13.6   Pass    Vertical
             43.053                  34.0                    40.0    6.0   Pass    Vertical
             68.708                  27.4                    40.0   12.6   Pass    Vertical
             85.880                  23.8                    40.0   16.2   Pass    Vertical
             103.063                 20.2                    43.5   23.3   Pass    Vertical
             120.238                 22.6                    43.5   20.9   Pass    Vertical
             126.970                 28.0                    43.5   15.5   Pass    Vertical
             137.415                 30.3       26.5         43.5   13.2   Pass    Vertical
             154.593                 23.2       25.6         43.5   17.9   Pass   Horizontal
             159.715                            32.1         43.5   11.4   Pass   Horizontal
             166.100                 33.1                    43.5   10.4   Pass    Vertical
             173.607                            34.1         43.5    9.4   Pass   Horizontal
             174.058                 28.6                    43.5   14.9   Pass    Vertical
             188.950                 29.7                    43.5   13.8   Pass    Vertical
             189.940                 26.6                    43.5   16.9   Pass    Vertical
             193.450                            34.5  34.5   43.5   9.0    Pass   Horizontal
             202.150                            33.8         43.5    9.7   Pass   Horizontal
             206.120                 22.5                    43.5   21.0   Pass    Vertical
             274.828                            33.0         46.0   13.0   Pass   Horizontal
             292.010                 21.5       29.6         46.0   16.4   Pass   Horizontal
             300.090                 19.5       27.0         46.0   19.0   Pass   Horizontal
             326.354                 26.5       29.2         46.0   16.8   Pass   Horizontal
             343.534                 27.8       35.1         46.0   10.9   Pass   Horizontal
             412.243                 32.0       33.1         46.0   12.9   Pass   Horizontal
             429.419                 26.7                    46.0   19.3   Pass    Vertical
             472.363                 30.0       31.0         46.0   15.0   Pass   Horizontal
             480.950                 26.1       34.0         46.0   12.0   Pass   Horizontal
             489.540                 32.0       31.2         46.0   14.0   Pass    Vertical
             498.128                 32.2       34.4         46.0   11.6   Pass   Horizontal


        No further emissions detected within 20 dB of the applicable limit.




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 16 of 23               This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


        Device powered using internal batteries

          Frequency                       Level      Recheck Limit Margin Result Worst Case
                                   Vertical    Hort                               Antenna
              MHz                  dBuV/m dBuV/m dBuV/m dBuV/m       dB
             34.353                  26.4                    40.0   13.6   Pass    Vertical
             42.943                  21.0                    40.0   19.0   Pass    Vertical
             68.708                  22.0                    40.0   18.0   Pass    Vertical
             85.880                  21.0                    40.0   19.0   Pass    Vertical
             103.063                 20.2                    43.5   23.3   Pass    Vertical
             120.238                 24.9                    43.5   18.6   Pass    Vertical
             126.970                 28.0                    43.5   15.5   Pass    Vertical
             137.415                 30.3       30.5         43.5   13.0   Pass   Horizontal
             154.593                 23.2       29.8         43.5   13.7   Pass   Horizontal
             166.100                 24.1                    43.5   19.4   Pass    Vertical
             171.450                 26.3                    43.5   17.2   Pass    Vertical
             188.950                            26.1         43.5   17.4   Pass   Horizontal
             189.210                 26.0                    43.5   17.5   Pass    Vertical
             201.978                            32.6         43.5   10.9   Pass   Horizontal
             206.120                 22.5       30.6         43.5   12.9   Pass   Horizontal
             274.828                            33.2         46.0   12.8   Pass   Horizontal
             292.010                 21.5       30.6         46.0   15.4   Pass   Horizontal
             326.358                            31.3         46.0   14.7   Pass   Horizontal
             343.534                 29.2       35.2         46.0   10.8   Pass   Horizontal
             412.243                 32.0       31.9         46.0   14.0   Pass    Vertical
             480.950                 30.1       33.1         46.0   12.9   Pass   Horizontal
             498.128                 30.0       31.4         46.0   14.6   Pass   Horizontal
             515.278                            31.1         46.0   14.9   Pass   Horizontal
             824.482                 32.9                    46.0   13.1   Pass    Vertical
             893.193                            31.9         46.0   14.1   Pass   Horizontal


        No further emissions detected within 20 dB of the applicable limit.




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 17 of 23               This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007



7.         TEST EQUIPMENT USED
        Instrument                          Manufacturer    Model                                        Serial No               Asset Ref                Cal Due
     Aerial Controller                         EMCO          1090                                       9112-1062                RFS 3710              Not applicable
        Aerial Mast                            EMCO         1070-1                                      9203-1661                RFS 3708              Not applicable
     Biconical Antenna                      Schwarzbeck BBA 9106                                             -                   RFS 3612                7 Feb 2009
         Receiver                              R&S         ESCS 30                                      847124/020                E1595                 21 Dec 2007
         Receiver                              R&S         ESHS 10                                      828404/005               RFS 3728              11 July 2008
       Log Periodic                         Schwarzbeck VUSLP 9111                                       9111-228                  3785                  7 Feb 2009
       Loop Antenna                            EMCO          6502                                       9003-2485                HTS0201               11 July 2008
      Mains Network                            EMCO         3825/2                                      9206-1967                  3774                 8 June 2008
          Variac                            General Radio    1592                                            -                   RFS 3690              Not applicable
         Turntable                             EMCO       1080-1-2.1                                    9109-1578                RFS 3709              Not applicable
        VHF Balun                           Schwarzbeck VHA 9103                                             -                   RFS 3603                7 Feb 2009

8.            ACCREDITATIONS
              Testing was carried out in accordance with EMC Technologies Ltd registration with
              the Federal Communications Commission as a listed facility, registration number:
              90838, which was updated on January 23rd, 2007.

              All testing was carried out in accordance with the terms of EMC Technologies (NZ)
              Ltd International Accreditation New Zealand (IANZ) Accreditation to
              NZS/ISO/IEC 17025, 2005.

              All measurement equipment has been calibrated in accordance with the terms of the
              EMC Technologies (NZ) Ltd International Accreditation New Zealand (IANZ)
              Accreditation to NZS/ISO/IEC 17025, 2005.

              International Accreditation New Zealand has Mutual Recognition Arrangements for
              testing and calibration with 46 accreditation bodies in 34 economies. This includes
              NATA (Australia), UKAS (UK), SANAS (South Africa), NVLAP (USA), A2LA
              (USA), SWEDAC (Sweden). Further details can be supplied on request.




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 18 of 23               This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


9.              PHOTOGRAPH (S)




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 19 of 23               This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


                                                                      Ancillary Equipment




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 20 of 23               This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007


                                         High frequency radiated emissions test set up




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 21 of 23               This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 22 of 23               This report may not be reproduced except in full


                                              EMC Technologies (NZ) Ltd
                                                              Test Report No 70626.2b
                                                           Report date: 11 September 2007

                                  300 Metre Radiated Emission Extrapolation Test Set Up




                                                          Conducted Emissions Test Set Up




__________________________________________________________________________________________________________________________________________________________________________________


EMC Technologies (NZ) Ltd                                                                                      Telephone: +64 9 360 0862 Fax: +64 9 360 0861
STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand                                         E-mail: aucklab@ihug.co.nz
POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand                                                  Web Site: www.emctech.com.au
Page 23 of 23               This report may not be reproduced except in full



Document Created: 2007-09-12 07:27:15
Document Modified: 2007-09-12 07:27:15

© 2025 FCC.report