Test Report

FCC ID: M5VG0260X

Test Report

Download: PDF
FCCID_3986505

                                            Page 1 of 26

                                                                           EMC Technologies Pty. Ltd.
                                                                                     ABN 82 057 105 549
                                                                    Melbourne                      Sydney
                                                                    176 Harrick Road               Unit 3/87 Station Road
                                                                    Keilor Park, Vic 3042          Seven Hills, NSW 2147
                                                                    Tel: +61 3 9365 1000           Tel: +61 2 9624 2777
                                                                           Email: emc-general@emctech.com.au
                                                                               Web: www.emctech.com.au




               RADIO REPORT FOR CERTIFICATION


                       47 CFR PART 15 SUBPART C



                CLIENT:                                GALLAGHER GROUP LTD.
DEVICE UNDER TEST / PMN:                               WEIGH SCALE AND READER
   MODEL NUMBER / HVIN:                                TWR5
                 FCC ID:                               M5VG02606


           REPORT NUMBER: M171220-1aR1
                                                    (Replacement for report number M171220-1a)
               DATE OF ISSUE: 31 August 2018




 EMC Technologies Pty Ltd reports apply only to the specific samples tested under stated test conditions.
 It is the manufacturer’s responsibility to assure that additional production units of this model are
 manufactured with identical electrical and mechanical components. EMC Technologies Pty Ltd shall
 have no liability for any deductions, inferences or generalisations drawn by the client or others from EMC
 Technologies Pty Ltd issued reports. This report shall not be used to claim, constitute or imply product
 endorsement by EMC Technologies Pty Ltd.




                                                 Accredited for compliance with ISO/IEC 17025 - Testing.
                           The results of tests, calibration and/or measurements included in this document are traceable to
                           Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement
                           for the mutual recognition of the equivalence of testing, medical testing, calibration and inspection
                           reports.

                            This document shall not be reproduced except in full, with the exception of the Certificate
                                                           of Compliance on Page 3


                                                                      Page 2 of 26                             Report Number: M171220-1aR1
                                                                                                                        FCC ID: M5VG02606




Contents
1.0     INTRODUCTION .......................................................................................................................... 4
  1.1      Test Procedure ......................................................................................................................................... 4
  1.2      Summary of 47 CFR Part 15 Subpart C Results ........................................................................................ 4

2.0     GENERAL INFORMATION .......................................................................................................... 5
  2.1      Equipment Under Test (EUT) - Transmitter Details ................................................................................. 5
  2.2      EUT - Host Details .................................................................................................................................... 5
  2.3      Test Configuration ................................................................................................................................... 5
  2.4      Modifications by EMC Technologies ........................................................................................................ 5
  2.5      Test Facility.............................................................................................................................................. 6
  2.6      Test Equipment Calibration ..................................................................................................................... 7

3.0     TEST RESULTS ........................................................................................................................... 8
  3.1      §15.203 Antenna Requirement ............................................................................................................... 8
  3.2      §15.207 Conducted Limits ....................................................................................................................... 8
  3.4      §15.205 Restricted Bands of Operation ................................................................................................ 10
  3.5      §15.209 Radiated emission limits; general requirements ..................................................................... 10
  3.6      §1.1310 Maximum Permissible Exposure .............................................................................................. 25
  3.8      §2.1049 Occupied bandwidth – 99% power .......................................................................................... 25

4.0     COMPLIANCE STATEMENT .................................................................................................... 26

5.0     MEASUREMENT UNCERTAINTY ............................................................................................. 26




                                                                          Accredited for compliance with ISO/IEC 17025 - Testing.
                                                      The results of tests, calibration and/or measurements included in this document are traceable
                                                      to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                                                      Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                                                      and inspection reports.

                                                            This document shall not be reproduced except in full, with the exception of the
                                                                                Certificate of Compliance on Page 3


                                           Page 3 of 26                         Report Number: M171220-1aR1
                                                                                         FCC ID: M5VG02606




                               RADIO REPORT
                        CERTIFICATE OF COMPLIANCE
Device under Test / PMN:   Weigh Scale and Reader
Model Number / HVIN:       TWR5
Manufacturer:              Gallagher Group Ltd.



Tested for:                Gallagher Group Ltd.
Address:                   181 Kahikatea Drive, Melville, Hamilton, 3026, New Zealand
Phone:                     +64 7 838 9800
Contact:                   Menardo Lazaro
Email:                     menardo.lazaro@gallagher.com



Standards:                 47 CFR Part 15 – Radio Frequency Devices
                           Subpart C – Intentional Radiators



Test Dates:                8 January to 21 February 2018
Issue Date:                31 August 2018
Issued by:                 EMC TECHNOLOGIES PTY. LTD.,
                           176 Harrick Road, Keilor Park, VIC 3042, Australia.
                           Phone: +61 3 9365 1000, Web: www.emctech.com.au



Attestation:               I hereby certify that the device(s) described herein were tested as
                           described in this report and that the data included is that which was
                           obtained during such testing




Test Officer:              William Alam




Authorised Signatory:      Chris Zombolas
                           Technical Director
                           EMC Technologies Pty Ltd




                                                  Accredited for compliance with ISO/IEC 17025 - Testing.
                              The results of tests, calibration and/or measurements included in this document are traceable
                              to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                              Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                              and inspection reports.

                                   This document shall not be reproduced except in full, with the exception of the
                                                       Certificate of Compliance on Page 3


                                             Page 4 of 26                         Report Number: M171220-1aR1
                                                                                           FCC ID: M5VG02606



                            RADIO REPORT FOR CERTIFICATION
                                            to
                                 47 CFR Part 15 Subpart C

1.0   INTRODUCTION

      Radio tests were performed on the TWR5 Weigh Scale and Reader in accordance with the
      applicable requirements of 47 CFR, Part 15 Subpart C for a transmitter operating at 134 kHz.

1.1   Test Procedure

      Radio measurements were performed in accordance with the appropriate procedures of
      ANSI C63.10: 2013.

      The measurement instrumentation conformed to the requirements of ANSI C63.2: 2009.

1.2   Summary of 47 CFR Part 15 Subpart C Results

        FCC             Test Performed                                                                          Results
        15.203          Antenna requirement                                                                    Complied
        15.205          Restricted bands of operation                                                          Complied
        15.207          Conducted limits                                                                       Complied
        15.209          Radiated emissions limits; general requirements                                        Complied
        2.1049          Occupied Bandwidth                                                                      163 Hz




                                                    Accredited for compliance with ISO/IEC 17025 - Testing.
                                The results of tests, calibration and/or measurements included in this document are traceable
                                to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                                Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                                and inspection reports.

                                     This document shall not be reproduced except in full, with the exception of the
                                                         Certificate of Compliance on Page 3


                                              Page 5 of 26                         Report Number: M171220-1aR1
                                                                                            FCC ID: M5VG02606



2.0   GENERAL INFORMATION
      (Information supplied by the Client)

2.1   Equipment Under Test (EUT) - Transmitter Details

        Radio:                                        RFID
        Frequency Band:                               134.0 kHz
        Frequency Range:                              134.0 kHz
        Modulation:                                   AM
        Emission Designator:                          K1D
        Antenna type and gain:                        Type 1: 600 x 400 mm Small Panel, inductive loop
                                                      Type 2: 1300 x 600 mm Large Panel, inductive loop

2.2   EUT - Host Details

        Device under Test / PMN:                     Weigh Scale and Reader
        Model Number / HVIN:                         TWR5
        Serial Number:                               1745175111
        Manufacturer:                                Gallagher Group Ltd
        Power Supply:                                12 VDC via power supply
        Highest Frequency:                           600 MHz

2.3   Test Configuration

      Testing was performed with the RFID set to continuously transmit a modulated signal.

2.4   Modifications by EMC Technologies

      No modifications were performed.




                                                     Accredited for compliance with ISO/IEC 17025 - Testing.
                                 The results of tests, calibration and/or measurements included in this document are traceable
                                 to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                                 Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                                 and inspection reports.

                                      This document shall not be reproduced except in full, with the exception of the
                                                          Certificate of Compliance on Page 3


                                               Page 6 of 26                         Report Number: M171220-1aR1
                                                                                             FCC ID: M5VG02606



2.5     Test Facility

2.5.1   General

        EMC Technologies Pty Ltd has also been accredited as a Conformity Assessment Body (CAB)
        by Australian Communications and Media Authority (ACMA) under the APECTEL MRA and is
        designated to perform compliance testing on equipment subject to Declaration of Conformity
        (DoC) and Certification under Parts 15 and 18 of the FCC Commission’s rules – Registration
        Number 494713 & Designation number AU0001.

        EMC Technologies indoor open are test site (iOATS) have been accepted by Industry Canada
        for the performance of radiated measurements in accordance with RSS-Gen, Issue 8 - Industry
        Canada iOATS number - IC 3569B

        Measurements in this report were performed at EMC Technologies' laboratory in Keilor Park,
        Victoria Australia.

2.5.2   NATA Accreditation

        EMC Technologies is accredited in Australia by the National Association of Testing Authorities
        (NATA). All testing in this report has been conducted in accordance with EMC Technologies’
        scope of NATA accreditation.

        NATA is the Australian National laboratory accreditation body and has accredited EMC
        Technologies to IEC/ISO17025. A major requirement for accreditation is the assessment of the
        company and its personnel as being technically competent in testing to the standards. This
        requires documented test procedures, continued calibration of measurement equipment,
        traceable to the National Standard at the National Measurements Institute (NMI) and an internal
        quality system to ISO 9002. NATA has mutual recognition agreements with the National
        Voluntary Laboratory Accreditation Program (NVLAP) and the American Association for
        Laboratory Accreditation (A2LA).

        The current full scope of accreditation can be found on the NATA website: www.nata.com.au




                                                      Accredited for compliance with ISO/IEC 17025 - Testing.
                                  The results of tests, calibration and/or measurements included in this document are traceable
                                  to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                                  Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                                  and inspection reports.

                                       This document shall not be reproduced except in full, with the exception of the
                                                           Certificate of Compliance on Page 3


                                             Page 7 of 26                         Report Number: M171220-1aR1
                                                                                           FCC ID: M5VG02606



2.6   Test Equipment Calibration

      Measurement instrumentation and transducers were calibrated in accordance with the
      applicable standards by an independent NATA registered laboratory such as Agilent
      Technologies (Australia) Pty Ltd or the National Measurement Institute (NMI) or in-house. All
      equipment calibration is traceable to Australian national standards at the National
      Measurements Institute.

      Equipment     Make/Model/Serial Number                                 Last Cal.            Due Date               Cal.
      Type                                                                 dd/mm/yyyy           dd/mm/yyyy             Interval

                    Frankonia SAC-10-2                                     22/03/2017           22/03/2018            1 Year, *1
      Chamber
                    (R-139)

                    R&S ESW26, 2 Hz – 26.5 GHz                             31/03/2017           31/03/2018            1 Year, *2
      EMI           Sn: 101306 (R-143)
      Receiver      R&S ESCI, 9kHz – 3GHz                                  13/06/2017           13/06/2018            1 Year, *2
                    Sn: 100011 (R-028)

                    EMCO 6502 Active Loop                                  20/07/2015           20/07/2018            3 Year, *2
                    9 kHz – 30 MHz
                    Sn. 9311-2801 (A-231)
                    SUNOL JB6 Biconilog                                    26/05/2016           26/05/2018            2 Year, *2
      Antennas
                    30 – 6000 MHz
                    Sn. A012312 (A-363)
                    EMCO 3115 Double Ridge Horn                            15/07/2016           15/07/2019            3 Year, *1
                    1 – 18 GHz
                    Sn: 8908-3282 (A-004)

                    Room 12 inbuilt cable Panel 1 to 10 m                  31/05/2017           31/05/2018            1 Year, *1
                    (C-422)
                    Room 12 inbuilt cable Panel 1 to 3 m                   31/05/2017           31/05/2018            1 Year, *1
                    (C-421)
                    Room 12 Antenna cable                                  31/05/2017           31/05/2018            1 Year, *1
      Cables        (C-437)
                    Sucoflex 104 Huber & Suhner                            31/05/2017           31/05/2018            1 Year, *1
                    18 GHz, 5 m cable (C-337)
                    BNC cable 4 m                                          04/01/2018           04/01/2019            1 Year, *1
                    (C-399)
                    N-type Cable 30m                                       25/10/2017           25/10/2018            1 Year, *1
                    (C-219)

                    EMCO 3810/2NM LISN                                     05/01/2017           05/01/2019            2 Year, *1
      LISN
                    Sn: 9607-1505 (L-019)

                    Hewlett Packard 11947A Limiter                         18/07/2017           18/07/2018            1 Year, *1
      Limiter       Transient
                    Sn: 3107A02888 (L-017)

      Note *1. Internal NATA calibration.
      Note *2. External NATA / A2LA calibration




                                                    Accredited for compliance with ISO/IEC 17025 - Testing.
                                The results of tests, calibration and/or measurements included in this document are traceable
                                to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                                Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                                and inspection reports.

                                     This document shall not be reproduced except in full, with the exception of the
                                                         Certificate of Compliance on Page 3


                                                  Page 8 of 26                         Report Number: M171220-1aR1
                                                                                                FCC ID: M5VG02606



3.0     TEST RESULTS

3.1     §15.203 Antenna Requirement

        The connector for the antenna was a unique type ensuring that only the intended antennas
        could be used.




3.2     §15.207 Conducted Limits

3.2.1   Test Procedure

        The arrangement specified in ANSI C63.10: 2013 was adhered to for the conducted EMI
        measurements. The EUT was placed in the RF screened enclosure and a CISPR EMI Receiver
        as defined in ANSI C63.2: 2009 was used to perform the measurements.

        The EMI Receiver was operated under program control using the Max-Hold function and
        automatic frequency scanning, measurement and data logging techniques. The specified 0.15
        MHz to 30 MHz frequency range was sub-divided into sub-ranges to ensure that all short
        duration peaks were captured.
3.2.2   Peak Maximising Procedure

        The various operating modes of the system were investigated. For each of the sub-ranges, the
        EMI receiver was set to continuous scan with the Peak detector set to Max-Hold mode. The
        Quasi-Peak detector and the Average detector were then invoked to measure the actual Quasi-
        Peak and Average level of the most significant peaks, which were detected.

3.2.3   Calculation of Voltage Levels

        The voltage levels were automatically measured in software and compared to the test limit. The
        method of calculation was as follows:

        VEMI = VRx + L

        Where: VEMI      = The Measured EMI voltage in dBµV to be compared to the limit.
               VRx       = The Voltage in dBµV read directly at the EMI receiver.
               L         = The insertion loss in dB of the LISN, cables and transient Limiter.

3.2.4   Plotting of Conducted Emission Measurement Data

        The measurement data pertaining to each frequency sub-range were concatenated to form a
        single graph of (peak) amplitude versus frequency. This was performed for both Active and
        Neutral lines and the composite graph was subsequently plotted. A list of the highest relevant
        peaks and the respective Quasi-Peak and Average values were also plotted on the graph.

3.2.5   Test Climatic Conditions

        Shielded Room Temperature: 23C
        Relative Humidity: 52%

                                                         Accredited for compliance with ISO/IEC 17025 - Testing.
                                     The results of tests, calibration and/or measurements included in this document are traceable
                                     to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                                     Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                                     and inspection reports.

                                          This document shall not be reproduced except in full, with the exception of the
                                                              Certificate of Compliance on Page 3


                                                Page 9 of 26                         Report Number: M171220-1aR1
                                                                                              FCC ID: M5VG02606



3.2.6    Conclusion

         The sample complied with the applicable spurious emissions of §15.207. Refer to the following
         graphs for the results.




                                                 Quasi-Peak                                             Average
           Frequency
  Peak                    Line       Level          Limit   Margin                       Level            Limit           Margin
             [MHz]
                                    [dBV]         [dBV]   [dB]                       [dBV]           [dBV]           [dB]
    1         0.160      Active       43.8           65.5    -21.7                        24.3             55.5            -31.2
    2         0.774      Active       34.0            56     -22.0                        30.7              46             -15.3
    3         0.151      Active       43.2            66     -22.8                        21.7              56             -34.3
    4         0.622      Active       26.4            56     -29.6                        22.2              46             -23.8
    5         13.56      Active       30.2            60     -29.8                        23.5              50             -26.5
    6         1.994      Active       24.7            56     -31.3                        16.3              46             -29.7
    7         0.775      Active       33.9            56     -22.1                        30.4              46             -15.6
    8         0.155      Neutral      43.5           65.7    -22.2                        24.4             55.7            -31.3
    9         13.45      Neutral      29.1            60     -30.9                        22.7              50             -27.3
   10         2.032      Neutral      23.4            56     -32.6                        16.1              46             -29.9
   11         2.231      Neutral      22.6            56     -33.4                        15.9              46             -30.1
   12         26.27      Neutral      24.9            60     -35.1                        19.4              50             -30.6




                                                       Accredited for compliance with ISO/IEC 17025 - Testing.
                                   The results of tests, calibration and/or measurements included in this document are traceable
                                   to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                                   Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                                   and inspection reports.

                                        This document shall not be reproduced except in full, with the exception of the
                                                            Certificate of Compliance on Page 3


                                              Page 10 of 26                         Report Number: M171220-1aR1
                                                                                             FCC ID: M5VG02606



3.4     §15.205 Restricted Bands of Operation

        The restricted band limits were applied across the applicable spectrum and therefore complied
        with the restricted band requirements.

3.5     §15.209 Radiated emission limits; general requirements

3.5.1   Fundamental emission

        Testing was performed in an open test site at a distance of 10 and 30 metres. Different
        configurations of EUT and antenna polarization were investigated to produce highest emission
        EIRP and the EUT was set to transmit in continuous transmission mode.
        Antenna Type 1 Results:
               Freq.            Average                    Limit                      Margin                    Distance
               (kHz)           (dBμV/m)                  (dBμV/m)                      (dB)                     (metres)
               134.0             104.2                     85.0                        19.2                        10
               134.0              78.4                     65.0                        13.4                        30
               134.0              24.3                     25.0                        -0.7                       300

               Freq.             Peak                      Limit                      Margin                    Distance
               (kHz)           (dBμV/m)                  (dBμV/m)                      (dB)                     (metres)
               134.0             111.0                     105.0                        6.0                        10
               134.0             85.7                      85.0                         0.7                        30
               134.0             31.1                      45.0                        -13.9                      300

        Antenna Type 2 Results:
               Freq.            Average                    Limit                      Margin                    Distance
               (kHz)           (dBμV/m)                  (dBμV/m)                      (dB)                     (metres)
               134.0             103.9                     85.0                        18.9                        10
               134.0              78.8                     65.0                        13.8                        30
               134.0              24.3                     25.0                        -0.7                       300

               Freq.             Peak                      Limit                      Margin                    Distance
               (kHz)           (dBμV/m)                  (dBμV/m)                      (dB)                     (metres)
               134.0             110.6                     105.0                        5.6                        10
               134.0             85.9                      85.0                         0.9                        30
               134.0             31.1                      45.0                        -14.3                      300

        Calculation of extrapolation factor from measurement made at two distances:

        10 m to 30 m rolloff = 25.6 dB
        10 m to 30 m = 0.477 decade
        10 m to 300 m = 1.477 decade
        Extrapolation factor = 53.67 dB/decade
        10m to 300m correction factor = 53.67 dB/decade x 1.477 decade = 79.27 dB

        Add 79.27 dB to convert 10 m measurement value to 300 m measurement value.




                                                      Accredited for compliance with ISO/IEC 17025 - Testing.
                                  The results of tests, calibration and/or measurements included in this document are traceable
                                  to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                                  Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                                  and inspection reports.

                                       This document shall not be reproduced except in full, with the exception of the
                                                           Certificate of Compliance on Page 3


            Page 11 of 26                         Report Number: M171220-1aR1
                                                           FCC ID: M5VG02606




Antenna Type 1 30 metre measurement




Antenna Type 1 10 metre measurement




Antenna Type 2 30 metre measurement




Antenna Type 2 10 metre measurement




                    Accredited for compliance with ISO/IEC 17025 - Testing.
The results of tests, calibration and/or measurements included in this document are traceable
to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
and inspection reports.

     This document shall not be reproduced except in full, with the exception of the
                         Certificate of Compliance on Page 3


                                               Page 12 of 26                          Report Number: M171220-1aR1
                                                                                               FCC ID: M5VG02606



3.5.2   Radiated Spurious Measurements

        Radiated spurious emission measurements were performed in a semi-anechoic chamber
        compliant with ANSI C63.4: 2014.

        The test frequency range was sub-divided into smaller bands with sufficient frequency resolution
        to permit reliable display and identification of emissions.

                                Measurement            Measurement
          Frequency range
                                 Bandwidth               Distance                          Antenna
               [MHz]
                                   [kHz]                    [m]
            0.009 to 0.150          0.2                      10
                                                                                0.6 metre loop antenna
              0.150 to 30            9                       10
              30 to 1000            120                      10                 Biconilog hybrid
            1000 to 18 000         1000                       3                 Standard gain or broad
           18 000 to 40 000        1000                       1                 band horns

        The sample was slowly rotated with the spectrum analyser set to Max-Hold. This was performed
        for at least two antenna heights. When an emission was located, it was positively identified and
        its maximum level found by rotating the automated turntable and by varying the antenna height.
        Devices design for a fixed position were tested in that position, portable devices were tested in
        three orthogonal orientations.

        The measurement data for each frequency range was corrected for cable losses, antenna
        factors and preamplifier gain. This process was performed for both horizontal and vertical
        antenna polarisations.

        Calculation of field strength

        The field strength was calculated automatically by the software using the pre-stored calibration
        data. The method of calculation is shown below:
                                          𝑬 = 𝑽 + 𝑨𝑭 − 𝑮 + 𝑳
        Where: E = Radiated Field Strength in dBµV/m.
                V = EMI Receiver Voltage in dBµV/m.
                AF = Antenna Factor in dB. (stored as a data array)
                G = Preamplifier Gain in dB. (stored as a data array)
                L = Cable loss in dB. (stored as a data array of Insertion Loss versus frequency)

        Field strength conversion over distance

        To convert a limit given at a certain distance to a limit at the measurement distance or vice-
        versa the following equation was applied:
                                                                              𝑬𝒚
                                                                                ⁄
                                                          𝒅𝒚 × 𝟏𝟎                𝟐𝟎
                                          𝑬𝒙 = 𝟐𝟎 × 𝐥𝐨𝐠 (                             )
                                                              𝒅𝒙
        Where: Ex = Electric field at x metres (dBµV/m)
               Ey = Electric field at y metres (dBµV/m)
               dx = Measurement distance of x metres
               dy = Measurement distance of y metres

3.5.3   Spurious Emission Limit

        The EUT emissions were subjected to 15.209 limits over the 9 kHz to 30 MHz range and 15.109
        Class A limit over the 30 MHz to 6 GHz range pursuant to 15.31(k) as the device was considered
        a Class A unintentional radiator.


                                                       Accredited for compliance with ISO/IEC 17025 - Testing.
                                   The results of tests, calibration and/or measurements included in this document are traceable
                                   to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                                   Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                                   and inspection reports.

                                        This document shall not be reproduced except in full, with the exception of the
                                                            Certificate of Compliance on Page 3


                                                Page 13 of 26                         Report Number: M171220-1aR1
                                                                                               FCC ID: M5VG02606



3.5.4   Radiated Spurious Emission Results

        Frequency Band: 9 kHz - 30 MHz
        Measurements were made at a distance of 10 metres. The measurement of emissions between
        9 kHz – 150 kHz were made with a resolution bandwidth (RBW) of 200 Hz and the video
        bandwidth (VBW) of 3 kHz, 150 kHz – 30 MHz were measured with the resolution bandwidth
        (RBW) of 9 kHz and the video bandwidth (VBW) of 30 kHz. Measurements were made with the
        loop antenna oriented perpendicular, parallel and ground-parallel with respect to the sample.

        Limit 15.209 was applied over the full range, 9 kHz to 30 MHz.

   Antenna Type 1: 600 x 400mm (9kHz – 30MHz)
    Frequency       Polarisation    Measured Level                             Limit              Margin            Detector
       MHz                              dBV/m                                dBV/m                dB
       0.536           Parallel          48.0                                  52.1                 -4.1                QP
       0.671           Parallel          45.3                                  50.2                 -4.9                QP
       0.401           Parallel          63.4                                  74.6                -11.2                AV

        21.4        Ground - Parallel                  20.7                      39.5               -18.8               QP
        0.403       Ground - Parallel                  47.4                      74.6               -27.2               AV

        0.538         Perpendicular                    44.7                      52.1                -7.4               QP
        0.669         Perpendicular                    41.6                      50.2                -8.6               QP
        0.403         Perpendicular                    58.9                      74.6               -15.7               AV

   Antenna Type 2: 1300 x 600mm (9kHz – 30MHz)
    Frequency       Polarisation    Measured Level                             Limit              Margin            Detector
       MHz                              dBV/m                                dBV/m                dB
       0.942        Perpendicular         46.3                                 47.2                 -0.9                QP
       0.538        Perpendicular         50.2                                 52.1                 -1.9                QP
       0.672        Perpendicular         47.5                                 50.2                 -2.7                QP
       1.075        Perpendicular         34.7                                 46.1                -11.4                QP
       22.01        Perpendicular         25.7                                 39.5                -13.8                QP
       0.403        Perpendicular         60.6                                 74.6                -14.0                AV
       22.42        Perpendicular         24.8                                 39.5                -14.7                QP
       0.268        Perpendicular         57.3                                 78.1                -20.8                AV

        0.939            Parallel                      43.1                      47.3                -4.2               QP
        0.671            Parallel                      44.3                      50.2                -5.9               QP
        0.539            Parallel                      45.9                      52.1                -6.2               QP
        1.075            Parallel                      34.6                      46.1               -11.5               QP
        21.4             Parallel                      24.9                      39.5               -14.6               QP
        0.403            Parallel                      55.3                      74.6               -19.3               AV

        22.42        Ground-Parallel                   29.0                      39.5               -10.5               QP
        0.521        Ground-Parallel                   41.8                      52.4               -10.6               QP
        0.93         Ground-Parallel                   36.2                      47.3               -11.1               QP
        0.403        Ground-Parallel                   44.7                      74.6               -29.9               AV




                                                        Accredited for compliance with ISO/IEC 17025 - Testing.
                                    The results of tests, calibration and/or measurements included in this document are traceable
                                    to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                                    Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                                    and inspection reports.

                                         This document shall not be reproduced except in full, with the exception of the
                                                             Certificate of Compliance on Page 3


                   Page 14 of 26                         Report Number: M171220-1aR1
                                                                  FCC ID: M5VG02606




   Antenna type 1 – 9kHz to 30MHz Parallel




Antenna type 1 – 9kHz to 30MHz Perpendicular



                           Accredited for compliance with ISO/IEC 17025 - Testing.
       The results of tests, calibration and/or measurements included in this document are traceable
       to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
       Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
       and inspection reports.

            This document shall not be reproduced except in full, with the exception of the
                                Certificate of Compliance on Page 3


                    Page 15 of 26                         Report Number: M171220-1aR1
                                                                   FCC ID: M5VG02606




Antenna type 1 – 9kHz to 30MHz Ground-Parallel




                            Accredited for compliance with ISO/IEC 17025 - Testing.
        The results of tests, calibration and/or measurements included in this document are traceable
        to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
        Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
        and inspection reports.

             This document shall not be reproduced except in full, with the exception of the
                                 Certificate of Compliance on Page 3


                   Page 16 of 26                         Report Number: M171220-1aR1
                                                                  FCC ID: M5VG02606




Antenna type 2 – 9kHz to 30MHz Perpendicular




   Antenna type 2 – 9kHz to 30MHz Parallel




                           Accredited for compliance with ISO/IEC 17025 - Testing.
       The results of tests, calibration and/or measurements included in this document are traceable
       to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
       Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
       and inspection reports.

            This document shall not be reproduced except in full, with the exception of the
                                Certificate of Compliance on Page 3


                Page 17 of 26                         Report Number: M171220-1aR1
                                                               FCC ID: M5VG02606




Antenna type 2 – 9kHz to 30MHz Ground-Parallel




                        Accredited for compliance with ISO/IEC 17025 - Testing.
    The results of tests, calibration and/or measurements included in this document are traceable
    to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
    Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
    and inspection reports.

         This document shall not be reproduced except in full, with the exception of the
                             Certificate of Compliance on Page 3


                                       Page 18 of 26                         Report Number: M171220-1aR1
                                                                                      FCC ID: M5VG02606



Frequency Band: 30 - 1000 MHz
Measurements were made at a distance of 10 metres for antenna type 1 and 3 metres for
antenna type 2. The measurements of emissions between 30 - 1000 MHz were made with
a resolution bandwidth (RBW) of 120 kHz and the video bandwidth (VBW) of 300 kHz.

While digital emissions were evaluated according to 15.109 class A from 30-1000 MHz,
transmitter related emissions were evaluated according to 15.209 up to 172 MHz i.e. the 10th
harmonic of the highest frequency 17.1776 MHz used in the transmitter circuits. There were
no emissions measured in relation to the transmitter circuits for Antenna type 1.

 Antenna Type 2: 1300 x 600mm (30-1000MHz)
   Frequency        Polarisation      Measured Level                            Limit              Margin
      MHz                                dBV/m                                dBV/m                dB
     103.02           Horizontal           27.9                                 43.5                -15.6

The §15.109 Class A limits were applied for the digital emissions.

 Antenna Type 1: 600 x 400mm (30-1000MHz)
   Frequency         Polarisation     Measured Level                            Limit              Margin
      MHz                                 dBV/m                               dBV/m                dB
     100.98             Vertical           38.5                                 43.5                 -5.0
     115.51             Vertical           34.0                                 43.5                 -9.5
     639.42             Vertical           36.9                                 46.4                 -9.5
     107.26             Vertical           33.5                                 43.5                -10.0
     168.29             Vertical           33.4                                 43.5                -10.1
     437.46             Vertical           35.4                                 46.4                -11.0
     168.29           Horizontal           31.6                                 43.5                -11.9
     421.76           Horizontal           34.3                                 46.4                -12.1
     90.77              Vertical           30.6                                 43.5                -12.9
     229.26             Vertical           32.9                                 46.4                -13.5
     50.87              Vertical           25.5                                 39.1                -13.6
     773.67             Vertical           31.1                                 46.4                -15.3
     100.95           Horizontal           28.2                                 43.5                -15.3
     639.61           Horizontal           26.9                                 46.4                -19.5
     224.81           Horizontal           26.7                                 46.4                -19.7
     817.25           Horizontal           25.2                                 46.4                -21.2

 Antenna Type 2: 1300 x 600mm (30-1000MHz)
   Frequency        Polarisation      Measured Level                            Limit              Margin
      MHz                                dBV/m                                dBV/m                dB
     316.80           Horizontal           45.5                                 56.9                -11.4
     404.30           Horizontal           43.3                                 56.9                -13.6
     100.95            Vertical            40.0                                 54.0                -14.0
     315.15           Horizontal           42.1                                 56.9                -14.8
     437.53            Vertical            42.1                                 56.9                -14.8
     410.43           Horizontal           41.6                                 56.9                -15.3
     437.41           Horizontal           41.6                                 56.9                -15.3
     328.27           Horizontal           41.0                                 56.9                -15.9
     706.39            Vertical            40.9                                 56.9                -16.0
     453.82            Vertical            40.7                                 56.9                -16.2
     100.94           Horizontal           37.3                                 54.0                -16.7
     304.96           Horizontal           40.1                                 56.9                -16.8
     90.87             Vertical            36.6                                 54.0                -17.4
     115.68            Vertical            36.5                                 54.0                -17.5
     639.25            Vertical            39.3                                 56.9                -17.6
     168.26           Horizontal           36.2                                 54.0                -17.8
     639.36           Horizontal           38.6                                 56.9                -18.3
     285.85            Vertical            38.3                                 56.9                -18.6
     279.72            Vertical            37.8                                 56.9                -19.1

                                               Accredited for compliance with ISO/IEC 17025 - Testing.
                           The results of tests, calibration and/or measurements included in this document are traceable
                           to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                           Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                           and inspection reports.

                                This document shall not be reproduced except in full, with the exception of the
                                                    Certificate of Compliance on Page 3


                        Page 19 of 26                         Report Number: M171220-1aR1
                                                                       FCC ID: M5VG02606



806.22   Horizontal                      36.5                      56.9              -20.4
224.87    Vertical                       35.8                      56.9              -21.1
221.15    Vertical                       35.6                      56.9              -21.3
50.52     Vertical                       27.6                      49.6              -22.0
206.39   Horizontal                      31.8                      54.0              -22.2
195.68    Vertical                       31.8                      54.0              -22.2
105.62   Horizontal                      31.6                      54.0              -22.4
910.21    Vertical                       30.1                      56.9              -26.8
66.13     Vertical                       21.8                      49.6              -27.8




                                Accredited for compliance with ISO/IEC 17025 - Testing.
            The results of tests, calibration and/or measurements included in this document are traceable
            to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
            Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
            and inspection reports.

                 This document shall not be reproduced except in full, with the exception of the
                                     Certificate of Compliance on Page 3


                   Page 20 of 26                         Report Number: M171220-1aR1
                                                                  FCC ID: M5VG02606




 Antenna type 1 – 30MHz to 1000MHz Vertical




Antenna type 1 – 30MHz to 1000MHz Horizontal



                           Accredited for compliance with ISO/IEC 17025 - Testing.
       The results of tests, calibration and/or measurements included in this document are traceable
       to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
       Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
       and inspection reports.

            This document shall not be reproduced except in full, with the exception of the
                                Certificate of Compliance on Page 3


                   Page 21 of 26                         Report Number: M171220-1aR1
                                                                  FCC ID: M5VG02606




 Antenna type 2 – 30MHz to 1000MHz Vertical




Antenna type 2 – 30MHz to 1000MHz Horizontal



                           Accredited for compliance with ISO/IEC 17025 - Testing.
       The results of tests, calibration and/or measurements included in this document are traceable
       to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
       Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
       and inspection reports.

            This document shall not be reproduced except in full, with the exception of the
                                Certificate of Compliance on Page 3


                                      Page 22 of 26                         Report Number: M171220-1aR1
                                                                                     FCC ID: M5VG02606



Frequency Band: 1 000 – 6 000 MHz

Measurements to 6 GHz were made at a distance of 3 metres. The measurements were
made with a resolution bandwidth (RBW) of 1000 kHz and the video bandwidth (VBW) of
1000 kHz.

The §15.109 Class A limits were applied.

 Antenna Type 1: 600 x 400 mm (1-6 GHz)
  Frequency       Polarisation     Measured Level                              Limit             Margin
     MHz                              dBV/m                                  dBV/m              dB
 Peak Detector
   1234.10          Vertical            52.1                                      80               -27.9
   1271.66         Horizontal           51.1                                      80               -28.9
   3933.54         Horizontal           42.5                                      80               -37.5
   3861.94          Vertical            41.4                                      80               -38.6
 Average Detector
   2119.05         Horizontal           28.8                                      60               -31.2
   3885.55          Vertical            26.6                                      60               -33.4
   3912.93         Horizontal           26.6                                      60               -33.4
   1244.95          Vertical            24.8                                      60               -35.2

 Antenna Type 2: 1300 x 600 mm (1-6 GHz)
  Frequency       Polarisation     Measured Level                              Limit             Margin
     MHz                              dBV/m                                  dBV/m              dB
 Peak Detector
   1160.36         Horizontal            53.2                                     80               -26.8
   1294.15          Vertical             50.4                                     80               -29.6
 Average Detector
   1243.69         Horizontal            25.9                                     60               -34.1
   1311.94          Vertical             25.0                                     60               -35.0




                                              Accredited for compliance with ISO/IEC 17025 - Testing.
                          The results of tests, calibration and/or measurements included in this document are traceable
                          to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                          Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                          and inspection reports.

                               This document shall not be reproduced except in full, with the exception of the
                                                   Certificate of Compliance on Page 3


                             Page 23 of 26                         Report Number: M171220-1aR1
                                                                            FCC ID: M5VG02606




 Antenna type 1 – 1 GHz to 6 GHz Vertical and Horizontal (Peak)




Antenna type 1 – 1 GHz to 6 GHz Vertical and Horizontal (Average)



                                     Accredited for compliance with ISO/IEC 17025 - Testing.
                 The results of tests, calibration and/or measurements included in this document are traceable
                 to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                 Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                 and inspection reports.

                      This document shall not be reproduced except in full, with the exception of the
                                          Certificate of Compliance on Page 3


                             Page 24 of 26                         Report Number: M171220-1aR1
                                                                            FCC ID: M5VG02606




 Antenna type 2 – 1 GHz to 6 GHz Vertical and Horizontal (Peak)




Antenna type 2 – 1 GHz to 6 GHz Vertical and Horizontal (Average)



                                     Accredited for compliance with ISO/IEC 17025 - Testing.
                 The results of tests, calibration and/or measurements included in this document are traceable
                 to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                 Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                 and inspection reports.

                      This document shall not be reproduced except in full, with the exception of the
                                          Certificate of Compliance on Page 3


                                          Page 25 of 26                         Report Number: M171220-1aR1
                                                                                         FCC ID: M5VG02606



3.6   §1.1310 Maximum Permissible Exposure

      The TWR5 complied with the applicable maximum permissible exposure levels. Refer to EMC
      Technologies report M171220-4.

3.8   §2.1049 Occupied bandwidth – 99% power

      The bandwidth containing 99% power of the transmitted signal was measured using the
      procedure from ANSI C63.10 section 6.9.

         Channel     99% Bandwidth           Low Frequency                   High Frequency
          [kHz]          [kHz]                   [kHz]                            [kHz]
          134.0          0.163                  134.128                          134.291




                                 99% Occupied Bandwidth




                                                  Accredited for compliance with ISO/IEC 17025 - Testing.
                              The results of tests, calibration and/or measurements included in this document are traceable
                              to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                              Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                              and inspection reports.

                                   This document shall not be reproduced except in full, with the exception of the
                                                       Certificate of Compliance on Page 3


                                            Page 26 of 26                         Report Number: M171220-1aR1
                                                                                           FCC ID: M5VG02606



4.0   COMPLIANCE STATEMENT

      The Weigh Scale and Reader TWR5 tested on behalf of Gallagher Group Ltd complied with the
      requirements of 47 CFR, Part 15 Subpart C - Rules for Radio Frequency Devices (intentional
      radiators) for a transmitter operating at 134.0 kHz.


5.0   MEASUREMENT UNCERTAINTY

      EMC Technologies has evaluated the equipment and the methods used to perform the
      emissions testing. The estimated measurement uncertainties for emissions tests shown within
      this report are as follows:

      Conducted Emissions:                          9 kHz to 30 MHz                                             ±3.2 dB

      Radiated Emissions:                           9 kHz to 30 MHz                                             ±4.1 dB
                                                    30 MHz to 300 MHz                                           ±5.1 dB
                                                    300 MHz to 1000 MHz                                         ±4.7 dB
                                                    1 GHz to 18 GHz                                             ±4.6 dB

      The above expanded uncertainties are based on standard uncertainties multiplied by a coverage
      factor of k=2, providing a level of confidence of approximately 95%.




                                                    Accredited for compliance with ISO/IEC 17025 - Testing.
                                The results of tests, calibration and/or measurements included in this document are traceable
                                to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition
                                Arrangement for the mutual recognition of the equivalence of testing, medical testing, calibration
                                and inspection reports.

                                     This document shall not be reproduced except in full, with the exception of the
                                                         Certificate of Compliance on Page 3



Document Created: 2019-08-30 06:42:29
Document Modified: 2019-08-30 06:42:29

© 2025 FCC.report