Users Manual

FCC ID: M5VC30047XA

Users Manual

Download: PDF
FCCID_3096897

Gallagher
T15 Terminal
Installation Note

T15 Mifare Reader Black: C300470                      T15 PIV Mifare Reader Black: C305470
T15 Mifare Reader White: C300471                      T15 PIV Mifare Reader White: C305471
T15 Multi Tech Reader Black: C300480                  T15 PIV Multi Tech Reader Black: C305480
T15 Multi Tech Reader White: C300481                  T15 PIV Multi Tech Reader White: C305481




3E4237 Gallagher T15 Reader | Edition 1 | June 2016
Copyright © Gallagher Group Limited                                                              Page 1


Disclaimer

This document gives certain information about products and/or services provided by Gallagher Group Limited
or its related companies (referred to as "Gallagher Group").

The information is indicative only and is subject to change without notice meaning it may be out of date at any
given time. Although every commercially reasonable effort has been taken to ensure the quality and accuracy
of the information, Gallagher Group makes no representation as to its accuracy or completeness and it should
not be relied on as such. To the extent permitted by law, all express or implied, or other representations or
warranties in relation to the information are expressly excluded.

Neither Gallagher Group nor any of its directors, employees or other representatives shall be responsible
for any loss that you may incur, either directly or indirectly, arising from any use or decisions based on the
information provided.

Except where stated otherwise, the information is subject to copyright owned by Gallagher Group and you may
not sell it without permission. Gallagher Group is the owner of all trademarks reproduced in this information.
All trademarks which are not the property of Gallagher Group, are acknowledged.

Copyright © Gallagher Group Ltd 2016. All rights reserved.




3E4237 Gallagher T15 Reader | Edition 1 | June 2016
Copyright © Gallagher Group Limited                                                                              Page 2


Contents

        1       Introduction...................................................................................................................................... 4
        2       Before you begin............................................................................................................................... 4
        3       Distance between proximity readers................................................................................................ 7
        4       Installation........................................................................................................................................ 8
        5       LED indications................................................................................................................................ 10
        6       Accessories..................................................................................................................................... 10
        7       Technical specifications................................................................................................................... 11
        8       Approvals and standards................................................................................................................. 12
        9       Mounting dimensions..................................................................................................................... 13




3E4237 Gallagher T15 Reader | Edition 1 | June 2016
Copyright © Gallagher Group Limited                                                                                                                           Page 3


1       Introduction

        The Gallagher T15 Reader is a smart card proximity reader. It can be installed as either an entry reader
        or exit reader. The reader contains an NXP chip for improved read range performance and supports
        Bluetooth® technology for hands-free access.
        The reader sends information to the Gallagher Controller and acts upon information sent from the
        Gallagher Controller. The reader itself does not make any access decisions.
        The reader is available in eight variants. The card technologies for each variant are shown below.

         Reader                                       Product code Supported card technologies
         T15 Mifare Reader Black                      C300470      Mifare DESFire EV1, Mifare Plus and Mifare Classic
         T15 Mifare Reader White                      C300471
         T15 Multi Tech Reader Black                  C300480      Mifare DESFire EV1, Mifare Plus, Mifare Classic and
         T15 Multi Tech Reader White                  C300481      125 KHz cards
         T15 PIV Mifare Reader Black                  C305470      PIV, PIV-I, Mifare DESFire EV1, Mifare Plus and
         T15 PIV Mifare Reader White                  C305471      Mifare Classic
         T15 PIV Multi Tech Reader Black C305480                   PIV, PIV-I, Mifare DESFire EV1, Mifare Plus, Mifare
         T15 PIV Multi Tech Reader White C305481                   Classic and 125 KHz cards

        The reader can be connected as an HBUS Reader or Cardax IV Reader. An HBUS Reader uses the HBUS
        communications protocol to communicate with the Gallagher Controller 6000. A Cardax IV Reader uses
        the Cardax IV communications protocol to communicate with a Gallagher Controller.
        HBUS Reader Compatibility
        HBUS communications are only supported for sites running Command Centre v7.00 software (or later).
        Gallagher Multi Tech Readers
        Gallagher strongly recommends against using dual technology 125/Mifare cards with Gallagher Multi
        Tech readers for sites running pre-Command Centre v7.00 software. From Command Centre v7.00, a
        site may specify which technology a Multi Tech reader should read off a dual technology card.
        Gallagher PIV Readers
        Gallagher PIV Readers connect to the Gallagher Controller 6000 High Spec PIV (C305101) only (referred
        to as the Controller). Gallagher PIV Readers can only be used with sites running Gallagher Command
        Centre vEL7.10 software (or later). Gallagher PIV Readers are connected as HBUS Readers only.




2       Before you begin



        2.1     Shipment contents
                Check the shipment contains the following items:
                  •      1 x Gallagher T15 Reader facia assembly
                  •      1 x Gallagher T15 Reader base
                  •      1 x M3 Torx Post Security screw
                  •      2 x 25 mm No.6 self tapping, pan head, Phillips drive fixing screws
                  •      2 x 40 mm No.6 self tapping, pan head, Phillips drive fixing screws


3E4237 Gallagher T15 Reader | Edition 1 | June 2016
Copyright © Gallagher Group Limited                                                                                  Page 4


        2.2     Power supply
                The Gallagher T15 Reader is designed to operate over a supply voltage range of 9 - 16 Vdc
                measured at the reader terminals. The operating current draw is dependant on the supply
                voltage at the reader. The power source should be linear or a good quality switched-mode
                power supply. The performance of the reader may be affected by a low quality, noisy power
                supply.



        2.3     Cabling
                The Gallagher T15 Reader requires a minimum cable size of 4 core 24 AWG (0.2 mm2) stranded
                security cable. This cable allows the transmission of data (2 wires) and power (2 wires). When
                using a single cable to carry both power supply and data, both the power supply voltage drop
                and data requirements must be considered. Although the reader is specified to operate at 9
                Vdc, for good engineering design it is recommended that the voltage at the reader should be
                approximately 12 Vdc.



                HBUS cabling topology
                The HBUS communications protocol is based on the RS485 standard and allows the reader to
                communicate over a distance of up to 500 m (1640 ft).

                The cabling between HBUS devices should be done in a "daisy chain" topology, (i.e. A "T" or
                "Star" topology should not be used between devices). Should "Star" or "Home-Run" wiring be
                required, the HBUS 4H/8H Modules and the HBUS Door Module allow multiple HBUS devices to
                be individually wired to the one physical location.

                The end devices on the HBUS cable should be terminated using 120 ohms resistance. To
                terminate the Gallagher Controller 6000, connect the supplied on-board termination jumpers
                to the Controller. To terminate a reader, connect the orange (termination) wire to the green
                (HBUS A) wire. Termination is already included at the HBUS Module, (i.e. each HBUS port is
                permanently terminated at the module).


                                                      HBUS      "T" or "Star" circuits are
                                                      Device    not permitted between
                                                                     HBUS devices




                                                                                                 RS485 1
                  HBUS                   HBUS         HBUS                 HBUS
                  Device                 Device       Device               Device               Controller 6000

                 Terminate                                                                   Connect the on-board
                                                                                              termination jumper




3E4237 Gallagher T15 Reader | Edition 1 | June 2016
Copyright © Gallagher Group Limited                                                                                 Page 5


                                         HBUS         "T" or "Star" circuits are
                                         Device       not permitted between
                                                           HBUS devices




                                                              RS485 1
                  HBUS                   HBUS                                                HBUS                HBUS
                  Device                 Device              Controller 6000                 Device              Device

                 Terminate                               Remove the on-board                                  Terminate
                                                          termination jumper



                                                         "T" or "Star" circuits are
                                             HBUS
                                                         not permitted between
                                             Device
                                                              HBUS devices



                                                                 Controller 6000

                                                                    H1      H4
                      HBUS                   HBUS                   H5      H8                   HBUS               HBUS
                      Device                 Device                                              Device             Device
                                                                   HBUS Module
                    Terminate                                                                                      Terminate


                                                          HBUS                      HBUS
                                                          Device                    Device

                                                        Terminate                  Terminate



                Cable distance

                  Cable type            Cable format*           HBUS                           Cardax IV           HBUS/Cardax IV
                                                                single reader                  single reader       single reader
                                                                connected using                connected using     connected using
                                                                data only in a                 data only in a      power and data
                                                                single cable                   single cable        in a single cable
                  CAT 5e or             4 twisted pair   500 m (1640 ft)                     200 m (650 ft)       100 m (330 ft)
                  better**              Each 2 x 0.2 mm2
                                        (24 AWG)
                  BELDEN 9842** 2 twisted pair   500 m (1640 ft)                             200 m (650 ft)       100 m (330 ft)
                  (shielded)    Each 2 x 0.2 mm2
                                (24 AWG)
                  SEC472                4 x 0.2 mm2             400 m (1310 ft)              200 m (650 ft)       100 m (330 ft)
                                        Not twisted
                                        pairs (24 AWG)
                  SEC4142               4 x 0.4 mm2             400 m (1310 ft)              200 m (650 ft)       150 m (500 ft)
                                        Not twisted
                                        pairs (21 AWG)
                * The matching of wire sizes to equivalent wire gauges are only approximate.
                ** Recommended cable types for optimal HBUS RS485 performance.

3E4237 Gallagher T15 Reader | Edition 1 | June 2016
Copyright © Gallagher Group Limited                                                                                             Page 6


                Notes:
                  •      Shielded cable may reduce the obtainable cable length. Shielded cable should be
                         grounded at the Controller end only.
                  •      If other cable types are used, operating distances and performance may be reduced
                         depending on the cable quality.
                  •      HBUS allows up to 20 readers to be connected to a single cable. Each reader requires at
                         least 9 Vdc to function correctly. The cable length and the number of readers connected
                         will have an impact on the voltage at each reader.




3       Distance between proximity readers

        The distance separating any two proximity readers must not be less than 200 mm (8 in) in all directions.




                      200 mm




        When mounting a proximity reader on an internal wall, check that any reader fixed to the other side of
        the wall is not less than 200 mm (8 inches) away.


                                               200
                                                      mm




3E4237 Gallagher T15 Reader | Edition 1 | June 2016
Copyright © Gallagher Group Limited                                                                          Page 7


4       Installation


                            ATTENTION: This equipment contains components that can be damaged by
                            electrostatic discharge. Ensure both you and the equipment are earthed before
                            beginning any servicing.


        The Gallagher T15 Reader is designed to be mounted on any solid flat surface. However installation on
        metal surfaces, particularly those with a large surface area will reduce read range. The extent to which
        the range is reduced will depend upon the type of metal surface.
        The recommended mounting height for the reader is 1.1 m (3.6 ft) from the floor level to the centre of
        the reader device. However this may vary in some countries and you should check local regulations for
        variations to this height.
        1.      Use the reader base as a guide to drill all three holes. Drill the 13 mm (1/2 inch) diameter centre
                hole (this is the centre hole for which the building cable will exit the mounting surface) and the
                two fixing holes.
        2.      Run the building cabling out through the centre hole and through the reader base.
        3.      Secure the base to the mounting surface using the two fixing screws provided. It is important the
                base of the reader is flush with and tight against the mounting surface. Three screw locations
                have been provided. Gallagher recommend using the outer screw locations.
                Note: It is strongly recommended that you use the screws provided. If an alternative screw is
                used, the head must be no larger nor deeper than that of the screw provided.
                Note: Ensure the centre hole allows the cable to run freely out through the mounting surface, so
                that the reader facia can clip into the base.



                No. 6 pan head screw                            Base




                          Building cable




                No. 6 pan head screw




        4.      Connect the reader tail extending from the facia assembly to the building cable. Connect the
                wires for the appropriate reader you wish to interface, either an HBUS Reader or a Cardax IV
                Reader, as shown. T15 PIV Readers must be connected as HBUS Readers.
                An HBUS Reader connects to a Gallagher Controller 6000, Gallagher 4H/8H Module (attached to
                a Controller 6000) or a Gallagher HBUS Door Module (connected to a Controller 6000).



3E4237 Gallagher T15 Reader | Edition 1 | June 2016
Copyright © Gallagher Group Limited                                                                           Page 8


                A Cardax IV Reader connects to a Gallagher Controller 6000, Gallagher 4R/8R Module (attached
                to a Controller 6000), Gallagher GBUS Universal Reader Interface (Gallagher GBUS URI), Gallagher
                Controller 3000-8R or 3000-4R, Gallagher Local Bus Universal Reader Interface (Gallagher URI) or
                a Gallagher Local Bus Reader I/O Interface.

                HBUS Reader connection:			                                            HBUS Reader terminated:

                                        Positive              Red                                        Positive              Red
                                        Negative             Black                                       Negative             Black
                     HBUS Reader




                                                                                           HBUS Reader
                                        HBUS Termination   Orange                                        HBUS Termination   Orange
                                        HBUS A              Green                                        HBUS A              Green
                                        HBUS B             Brown                                         HBUS B             Brown
                                        CDXIV TX            White                                        CDXIV TX            White
                                        CDXIV RX              Blue                                       CDXIV RX              Blue


                Note: To terminate an HBUS Reader, connect the Orange (HBUS Termination) wire to the Green
                (HBUS A) wire.		

                Cardax IV Reader connection:

                                        Positive              Red
                     Cardax IV Reader




                                        Negative             Black
                                        HBUS Termination   Orange
                                        HBUS A              Green
                                        HBUS B             Brown
                                        CDXIV TX            White
                                        CDXIV RX              Blue


        5.      Fit the facia assembly into the base by clipping the small lip, into the top of the base and holding
                the top, press the bottom of the facia assembly down into the base.
        6.      Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the
                hole at the bottom of the base to secure the facia assembly.
                Note: The Torx Post Security screw needs only to be lightly tightened.




                                                     Reader tail          Building cable




                                                      Facia
                                                                           Connection




                                                              Fit screw to secure facia to base




3E4237 Gallagher T15 Reader | Edition 1 | June 2016
Copyright © Gallagher Group Limited                                                                                                   Page 9


        7.      Removal of the facia assembly is a simple reversal of these steps.
        8.      Configure the reader in Command Centre. If the reader is connected as an HBUS Reader, refer to
                the topic "Configuring HBUS Devices" in the Command Centre Configuration Client Online Help.
                If the reader is connected as a Cardax IV Reader, refer to the topic "Creating Readers" in the
                Command Centre Configuration Client Online Help.




5       LED indications

         LED (squiggle)            HBUS indication
         3 Flash (Amber)           No communications with the Controller.
         2 Flash (Amber)           Communications with the Controller, but reader is not configured.
         1 Flash (Amber)           Configured to a Controller, but reader is not assigned to a door or elevator car.
         On (Green or Red)         Fully configured and functioning normally.
                                   Green = Access mode is Free
                                   Red = Access mode is Secure
         Flashes Green             Access has been granted.
         Flashes Red               Access has been denied.
         Flashes (Blue)            Reading and validating a PIV card.

         LED (squiggle)            Cardax IV indication
         3 Flash (Amber)           No communications with the Controller.
         On (Green or Red)         Fully configured and functioning normally.
                                   Green = Access mode is Free
                                   Red = Access mode is Secure
         Flashes Green             Access has been granted.
         Flashes Red               Access has been denied.




6       Accessories

         Accessory                                                                    Product code
         T15 Bezel, Black, Pk 10
         T15 Bezel, White, Pk 10
         T15 Bezel, Silver, Pk 10
         T15 Bezel, Gold, Pk 10
         T10 Dress Plate, Black, Pk 10                                                C300320
         T10 Spacer, Black, Pk 10                                                     C300300
         T10 Spacer, White, Pk 10                                                     C300301
         T10 Protective Cover Spacer                                                  C300310


3E4237 Gallagher T15 Reader | Edition 1 | June 2016
Copyright © Gallagher Group Limited                                                                              Page 10


7       Technical specifications

            Routine maintenance:                Not applicable for this reader
            Cleaning:                           This reader should only be cleaned with a clean, lint free, damp cloth
            Voltage:                            9 Vdc - 16 Vdc
            Current:                                                Mifare Reader               Multi Tech Reader
                                                                  Idle   1
                                                                             Maximum   2
                                                                                            Idle 1      Maximum 2
                                                at 9 Vdc         124 mA       175 mA       115 mA        164 mA
                                                at 13.6 Vdc      84 mA        113 mA       100 mA        124 mA
            Temperature range:                  -35 °C to +70 °C
                                                Note: Direct sunlight may increase the internal reader temperature
                                                above the ambient temperature level
            Humidity:                           0 - 95% non-condensing 3
            Environmental protection:           IP68
            Impact rating:                      IK07
            Unit dimensions:                    Height 139 mm (5.47 inches)
                                                Width 44 mm (1.73 inches)
                                                Depth 23 mm (0.9 inches)
            Maximum number of readers           20
            on one HBUS cable:
        1
             The reader is idle.
        2
             Peak current during card read.
        3
             Gallagher T Series readers are UL humidity tested and certified to 85% and have been independently
             verified to 95%.
        Note: The current values stated above have been reported using the default configuration for a reader
        in Command Centre. Changing the configuration may vary the current value.




3E4237 Gallagher T15 Reader | Edition 1 | June 2016
Copyright © Gallagher Group Limited                                                                                 Page 11


8       Approvals and standards

                          This symbol on the product or its packaging indicates that this product must not be disposed
                          of with other waste. Instead, it is your responsibility to dispose of your waste equipment by
                          handing it over to a designated collection point for the recycling of waste electrical and electronic
                          equipment. The separate collection and recycling of your waste equipment at the time of disposal
                          will help conserve natural resources and ensure that it is recycled in a manner that protects human
                          health and the environment. For more information about where you can drop off your waste
                          equipment for recycling, please contact your local city recycling office or the dealer from whom
                          you purchased the product.

                          This product complies with the environmental regulations for the Restriction of Hazardous
                          Substances in electrical and electronic equipment (RoHS). The RoHS directive prohibits the use of
                          electronic equipment containing certain hazardous substances in the European Union.


         FCC              This device complies with part 15 of the FCC Rules. Operation is subject to the following two
                          conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
                          interference received, including interference that may cause undesired operation.
                          Note: Changes or modifications not expressly approved by Gallagher Limited could void the user's
                          authority to operate this equipment.
                          Note: This equipment has been tested and found to comply with the limits for a Class B digital
                          device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
                          protection against harmful interference in a residential installation. This equipment generates,
                          uses and can radiate radio frequency energy and, if not installed and used in accordance with
                          the instructions, may cause harmful interference to radio communications. However, there is no
                          guarantee that interference will not occur in a particular installation. If this equipment does cause
                          harmful interference to radio or television reception, which can be determined by turning the
                          equipment off and on, the user is encouraged to try to correct the interference by one or more of
                          the following measures:
                          •      Reorient or relocate the receiving antenna.
                          •      Increase the separation between the equipment and receiver.
                          •      Connect the equipment into an outlet on a circuit different from that to which the receiver is
                                 connected.
                          •      Consult the dealer or an experienced radio/TV technician for help.

         Industry         This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to
         Canada           the following two conditions: (1) this device may not cause interference, and (2) this device must
                          accept any interference, including interference that may cause undesired operation of the device.

         Industrie        Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
         Canada           exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil
                          ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
                          radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.


                      ETSI EN 300 330-2 V1.5.1:2010
                      EN50130-4:1996

                                   US - Equipment: com, burg and acc reader
                                   CA - Equipment: com, burg reader


        Please refer to the document “3E2793 Gallagher Command Centre UL Configuration Requirements” for a guide
        to configuring the Gallagher system to the appropriate UL Standard.


3E4237 Gallagher T15 Reader | Edition 1 | June 2016
Copyright © Gallagher Group Limited                                                                                     Page 12


9       Mounting dimensions


                        67 mm (2.64")




                                                                                        139 mm (5.47")
                                        44 mm (1.73")




                                                        13 mm (1/2") diameter
                                                        hole for cable
                        16 mm (0.63")




                                                            44 mm (1.73")



                                                         IMPORTANT
                         This picture is not to scale, therefore use the measurements provided.