Gallagher
T10 Reader
Installation Note

T10 Mifare Reader Black: C300400
T10 Mifare Reader White: C300401
T10 PIV Reader Black: C305400
T10 PIV Reader White: C305401




3E4288 Gallagher T10 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited                     Page 1


Disclaimer

This document gives certain information about products and/or services provided by Gallagher Group Limited
or its related companies (referred to as "Gallagher Group").

The information is indicative only and is subject to change without notice meaning it may be out of date at any
given time. Although every commercially reasonable effort has been taken to ensure the quality and accuracy
of the information, Gallagher Group makes no representation as to its accuracy or completeness and it should
not be relied on as such. To the extent permitted by law, all express or implied, or other representations or
warranties in relation to the information are expressly excluded.

Neither Gallagher Group nor any of its directors, employees or other representatives shall be responsible
for any loss that you may incur, either directly or indirectly, arising from any use or decisions based on the
information provided.

Except where stated otherwise, the information is subject to copyright owned by Gallagher Group and you may
not sell it without permission. Gallagher Group is the owner of all trademarks reproduced in this information.
All trademarks which are not the property of Gallagher Group, are acknowledged.

Copyright © Gallagher Group Ltd 2016. All rights reserved.




3E4288 Gallagher T10 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited                                                                              Page 2


Contents

        1       Introduction...................................................................................................................................... 4
        2       Before you begin............................................................................................................................... 4
        3       Distance between readers................................................................................................................ 7
        4       Installation........................................................................................................................................ 7
        5       LED indications.................................................................................................................................. 9
        6       Accessories..................................................................................................................................... 10
        7       Technical specifications................................................................................................................... 10
        8       Approvals and standards................................................................................................................. 11
        9       Mounting dimensions..................................................................................................................... 12




3E4288 Gallagher T10 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited                                                                                                                           Page 3


1       Introduction

        The Gallagher T10 Reader is a smart card proximity reader. It can be installed as either an entry reader
        or exit reader. The reader sends information to the Gallagher Controller and acts upon information sent
        from the Gallagher Controller. The reader itself does not make any access decisions.
        The reader is available in four variants. The card technologies for each variant are shown below.

         Reader                                         Product codes    Supported card technologies
         T10 Mifare Reader Black                        C300400          Mifare DESFire EV1, Mifare Plus and
         T10 Mifare Reader White                        C300401          Mifare Classic
         T10 PIV Reader Black                           C305400          PIV, PIV-I, Mifare DESFire EV1, Mifare
         T10 PIV Reader White                           C305401          Plus and Mifare Classic

        The reader can be connected as an HBUS Reader or Cardax IV Reader. An HBUS Reader uses the HBUS
        communications protocol to communicate with the Gallagher Controller. A Cardax IV Reader uses the
        Cardax IV Reader communications protocol to communicate with the Gallagher Controller.
        IMPORTANT: HBUS compatibility
        HBUS communications are supported with sites running Gallagher Command Centre vEL7.00 software
        (or later).
        IMPORTANT: PIV readers
        Gallagher PIV readers connect to the Gallagher Controller 6000 High Spec PIV (C305101) only (referred
        to as the Controller). Gallagher PIV readers can only be used with sites running Gallagher Command
        Centre vEL7.10 software (or later). Gallagher PIV readers are connected as HBUS Readers only.




2       Before you begin



        2.1     Shipment contents
                Check the shipment contains the following items:
                  •      1 x Gallagher T10 Reader facia assembly
                  •      1 x Gallagher T10 Reader bezel
                  •      1 x M3 Torx Post Security screw
                  •      2 x 25 mm No.6 self tapping, pan head, Phillips drive fixing screws
                  •      2 x 40 mm No.6 self tapping, pan head, Phillips drive fixing screws



        2.2     Power supply
                The Gallagher T10 Reader is designed to operate over a supply voltage range of 9 - 16 Vdc
                measured at the reader terminals. The operating current draw is dependant on the supply
                voltage at the reader. The power source should be linear or a good quality switched-mode
                power supply. The performance of the reader may be affected by a low quality, noisy power
                supply.



3E4288 Gallagher T10 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited                                                                               Page 4


        2.3     Cabling
                The Gallagher T10 Reader requires a minimum cable size of 4 core 24 AWG (0.2 mm2) stranded
                security cable. This cable allows the transmission of data (2 wires) and power (2 wires). When
                using a single cable to carry both power supply and data, both the power supply voltage drop
                and data requirements must be considered. Although the reader is specified to operate at 9
                Vdc, for good engineering design it is recommended that the voltage at the reader should be
                approximately 12 Vdc.



                HBUS cabling topology
                The HBUS communications protocol is based on the RS485 standard and allows the reader to
                communicate over a distance of up to 500 m (1640 ft).

                The cabling between HBUS devices should be done in a "daisy chain" topology, (i.e. A "T" or
                "Star" topology should not be used between devices). Should "Star" or "Home-Run" wiring be
                required, the HBUS 4H/8H Modules and the HBUS Door Module allow multiple HBUS devices to
                be individually wired to the one physical location.

                The end devices on the HBUS cable should be terminated using 120 ohms resistance. To
                terminate the Gallagher Controller 6000, connect the supplied on-board termination jumpers
                to the Controller. To terminate a reader, connect the orange (termination) wire to the green
                (HBUS A) wire. Termination is already included at the HBUS Module, (i.e. each HBUS port is
                permanently terminated at the module).


                                                                  HBUS           "T" or "Star" circuits are
                                                                  Device         not permitted between
                                                                                      HBUS devices




                                                                                                                  RS485 1
                  HBUS                   HBUS                      HBUS                     HBUS
                  Device                 Device                    Device                   Device               Controller 6000

                 Terminate                                                                                    Connect the on-board
                                                                                                               termination jumper



                                         HBUS           "T" or "Star" circuits are
                                         Device         not permitted between
                                                             HBUS devices




                                                                RS485 1
                  HBUS                   HBUS                                               HBUS                  HBUS
                  Device                 Device                Controller 6000              Device                Device

                 Terminate                                 Remove the on-board                                  Terminate
                                                            termination jumper




3E4288 Gallagher T10 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited                                                                                                  Page 5


                                                        "T" or "Star" circuits are
                                             HBUS
                                                        not permitted between
                                             Device
                                                             HBUS devices



                                                               Controller 6000

                                                                    H1     H4
                       HBUS                  HBUS                   H5     H8                 HBUS             HBUS
                       Device                Device                                           Device           Device
                                                                  HBUS Module
                      Terminate                                                                               Terminate


                                                         HBUS                    HBUS
                                                         Device                  Device

                                                        Terminate               Terminate



                Cable distance

                  Cable type            Cable format*          HBUS                         Cardax IV         HBUS/Cardax IV
                                                               single reader                single reader     single reader
                                                               connected using              connected using   connected using
                                                               data only in a               data only in a    power and data
                                                               single cable                 single cable      in a single cable
                 CAT 5e or             4 twisted pair   500 m (1640 ft)                   200 m (650 ft)      100 m (330 ft)
                 better**              Each 2 x 0.2 mm2
                                       (24 AWG)
                 BELDEN 9842** 2 twisted pair   500 m (1640 ft)                           200 m (650 ft)      100 m (330 ft)
                 (shielded)    Each 2 x 0.2 mm2
                               (24 AWG)
                 SEC472                4 x 0.2 mm2            400 m (1310 ft)             200 m (650 ft)      100 m (330 ft)
                                       Not twisted
                                       pairs (24 AWG)
                 SEC4142               4 x 0.4 mm2            400 m (1310 ft)             200 m (650 ft)      150 m (500 ft)
                                       Not twisted
                                       pairs (21 AWG)
                * The matching of wire sizes to equivalent wire gauges are only approximate.
                ** Recommended cable types for optimal HBUS RS485 performance.
                Notes:
                  •       Shielded cable may reduce the obtainable cable length. Shielded cable should be
                          grounded at the Controller end only.
                  •       If other cable types are used, operating distances and performance may be reduced
                          depending on the cable quality.
                  •       HBUS allows up to 20 readers to be connected to a single cable. Each reader requires at
                          least 9 Vdc to function correctly. The cable length and the number of readers connected
                          will have an impact on the voltage at each reader.




3E4288 Gallagher T10 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited                                                                                        Page 6


3       Distance between readers

        The distance separating any two proximity readers must not be less than 200 mm (8 in) in all directions.
        When mounting a proximity reader on an internal wall, check that any reader fixed to the other side of
        the wall is not less than 200 mm (8 in) away.




                        200 mm



                                                                              200
                                                                                    mm




4       Installation

                           ATTENTION: This equipment contains components that can be damaged by
                           electrostatic discharge. Ensure both you and the equipment are earthed before
                           beginning any servicing.


        The Gallagher T10 Reader is designed to be mounted on any solid flat surface. However installation on
        metal surfaces, particularly those with a large surface area will reduce read range. The extent to which
        the range is reduced will depend upon the type of metal surface.
        The recommended mounting height for the reader is 1.1 m (3.6 ft) from the floor level to the centre of
        the reader device. However this may vary in some countries and you should check local regulations for
        variations to this height.
        1.      Use the reader bezel as a guide to drill all three holes. Drill the 13 mm (1/2 inch) diameter centre
                hole (this is the centre hole for which the building cable will exit the mounting surface) and the
                two fixing holes.
        2.      Run the building cabling out through the centre hole and through the reader bezel.
        3.      Secure the bezel to the mounting surface using the two fixing screws provided. It is important
                the bezel of the reader is flush with and tight against the mounting surface.
                Note: It is strongly recommended that you use the screws provided. If an alternative screw is
                used, the head must be no larger nor deeper than that of the screw provided.
                Note: Ensure the centre hole allows the cable to run freely out through the mounting surface, so
                that the reader facia can clip into the bezel.




3E4288 Gallagher T10 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited                                                                           Page 7


                No. 6 pan head screw
                                                                     Bezel




                               Building cable




                No. 6 pan head screw




        4.      Connect the reader tail extending from the facia assembly to the building cable. Connect the
                wires for the appropriate reader you wish to interface, either an HBUS Reader or a Cardax IV
                Reader, as shown.
                Note: Gallagher PIV readers must be connected as HBUS Readers. Gallagher PIV readers connect
                to the Gallagher Controller 6000 High Spec PIV (C305101) only.
                An HBUS Reader connects to a Gallagher Controller 6000, Gallagher 4H/8H Module (attached to
                a Controller 6000) or a Gallagher HBUS Door Module (connected to a Controller 6000).
                A Cardax IV Reader connects to a Gallagher Controller 6000, Gallagher 4R/8R Module (attached
                to a Controller 6000), Gallagher GBUS Universal Reader Interface (Gallagher GBUS URI), Gallagher
                Controller 3000-8R or 3000-4R, Gallagher Local Bus Universal Reader Interface (Gallagher URI) or
                a Gallagher Local Bus Reader I/O Interface.

                HBUS Reader connection:			                           HBUS Reader terminated:

                                        Positive              Red                      Positive              Red
                                        Negative             Black                     Negative             Black
                     HBUS Reader




                                                                         HBUS Reader




                                        HBUS Termination   Orange                      HBUS Termination   Orange
                                        HBUS A              Green                      HBUS A              Green
                                        HBUS B             Brown                       HBUS B             Brown
                                        CDXIV TX            White                      CDXIV TX            White
                                        CDXIV RX              Blue                     CDXIV RX              Blue


                Note: To terminate an HBUS Reader, connect the Orange (HBUS Termination) wire to the Green
                (HBUS A) wire.		

                Cardax IV Reader connection:

                                        Positive              Red
                     Cardax IV Reader




                                        Negative             Black
                                        HBUS Termination   Orange
                                        HBUS A              Green
                                        HBUS B             Brown
                                        CDXIV TX            White
                                        CDXIV RX              Blue




3E4288 Gallagher T10 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited                                                                                 Page 8


        5.      Fit the facia assembly into the bezel by clipping the small lip, into the top of the bezel and holding
                the top, press the bottom of the facia assembly down into the bezel.
        6.      Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the
                hole at the bottom of the bezel to secure the facia assembly.
                Note: The Torx Post Security screw needs only to be lightly tightened.




                                            Reader tail    Building cable




                                           Facia
                                                               Connection




                                              Fit screw to secure facia to bezel

        7.      Removal of the facia assembly is a simple reversal of these steps.
        8.      Configure the reader in Command Centre. If the reader is connected as an HBUS Reader, refer to
                the topic "Configuring HBUS Devices" in the Command Centre Configuration Client Online Help.
                If the reader is connected as a Cardax IV Reader, refer to the topic "Creating Readers" in the
                Command Centre Configuration Client Online Help.




5       LED indications

         LED (squiggle)            HBUS indication
         3 Flash (Amber)           No communications with the Controller.
         2 Flash (Amber)           Communications with the Controller, but reader is not configured.
         1 Flash (Amber)           Configured to a Controller, but reader is not assigned to a door or elevator car.
         On (Green or Red)         Fully configured and functioning normally.
                                   Green = Access mode is Free
                                   Red = Access mode is Secure
         Flashes Green             Access has been granted.
         Flashes Red               Access has been denied.
         Flashes (Blue)            Reading and validating a PIV card.



3E4288 Gallagher T10 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited                                                                               Page 9


            LED (squiggle)           Cardax IV indication
            3 Flash (Amber)          No communications with the Controller.
            On (Green or Red)        Fully configured and functioning normally.
                                     Green = Access mode is Free
                                     Red = Access mode is Secure
            Flashes Green            Access has been granted.
            Flashes Red              Access has been denied.




6       Accessories

            Accessory                                Product Code   Accessory                          Product Code
            T10 Dress Plate, Black, Pk 10            C300320        T10 Spacer, Black, Pk 10           C300300
            T10 Bezel, Black, Pk 10                  C300280        T10 Spacer, White, Pk 10           C300301
            T10 Bezel, White, Pk 10                  C300281        T10 Protective Cover Spacer        C300310
            T10 Bezel, Silver, Pk 10                 C300282        T10 Protective Cover               C300270
            T10 Bezel, Gold, Pk 10                   C300283        T10 Dress Plate Black - Pack 10    C300320




7       Technical specifications

            Routine maintenance:                Not applicable for this reader
            Cleaning:                           This reader should only be cleaned with a clean, lint free, damp cloth
            Voltage:                            9 Vdc - 16 Vdc
            Current:                                                              Idle 1              Maximum 2
                                                at 9 Vdc                         110 mA                158 mA
                                                at 13.6 Vdc                      74 mA                 105 mA
            Temperature range:                  -35 °C to +70 °C Note: Direct sunlight may increase the internal
                                                reader temperature above the ambient temperature level
            Humidity:                           0 - 95% non-condensing 3
            Environmental protection:           IP68
            Impact rating:                      IK07
            Unit dimensions:                    Height 115 mm (4.5 inches)
                                                Width 35 mm (1.4 inches)
                                                Depth 12 mm (0.5 inches)
            Maximum number of readers           20
            on one HBUS cable:
        1
             The reader is idle.
        2
             Peak current during card read.
        3
             Gallagher T Series readers are UL humidity tested and certified to 85% and have been independently
             verified to 95%.
        Note: The current values stated above have been reported using the default configuration for a reader
        in Command Centre. Changing the configuration may vary the current value.

3E4288 Gallagher T10 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited                                                                                Page 10


8       Approvals and standards

                          This symbol on the product or its packaging indicates that this product must not be disposed
                          of with other waste. Instead, it is your responsibility to dispose of your waste equipment by
                          handing it over to a designated collection point for the recycling of waste electrical and electronic
                          equipment. The separate collection and recycling of your waste equipment at the time of disposal
                          will help conserve natural resources and ensure that it is recycled in a manner that protects human
                          health and the environment. For more information about where you can drop off your waste
                          equipment for recycling, please contact your local city recycling office or the dealer from whom
                          you purchased the product.


         FCC              This device complies with part 15 of the FCC Rules. Operation is subject to the following two
                          conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
                          interference received, including interference that may cause undesired operation.
                          Note: Changes or modifications not expressly approved by Gallagher Limited could void the user's
                          authority to operate this equipment.
                          Note: This equipment has been tested and found to comply with the limits for a Class B digital
                          device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
                          protection against harmful interference in a residential installation. This equipment generates,
                          uses and can radiate radio frequency energy and, if not installed and used in accordance with
                          the instructions, may cause harmful interference to radio communications. However, there is no
                          guarantee that interference will not occur in a particular installation. If this equipment does cause
                          harmful interference to radio or television reception, which can be determined by turning the
                          equipment off and on, the user is encouraged to try to correct the interference by one or more of
                          the following measures:
                          •      Reorient or relocate the receiving antenna.
                          •      Increase the separation between the equipment and receiver.
                          •      Connect the equipment into an outlet on a circuit different from that to which the receiver is
                                 connected.
                          •      Consult the dealer or an experienced radio/TV technician for help.

         Industry         This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to
         Canada           the following two conditions: (1) this device may not cause interference, and (2) this device must
                          accept any interference, including interference that may cause undesired operation of the device.

         Industrie        Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
         Canada           exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil
                          ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
                          radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.


                  ETSI EN 300 330-2 V1.5.1:2011
                  EN50130-4:2011

                                  US - Equipment: com, burg and acc reader
                                  CA - Equipment: com, burg reader


        Please refer to the document “3E2793 Gallagher Command Centre UL Configuration Requirements” for a guide
        to configuring the Gallagher system to the appropriate UL Standard.




3E4288 Gallagher T10 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited                                                                                     Page 11


9       Mounting dimensions




                                                                                                               13 mm (1/2") diameter
                                                                                                               hole for cable
                                         40 mm (1.57")
                    115 mm (4.53")




                                                                                               40 mm (1.57")
                                         44 mm (1.73")




                                                                 22.5 mm (0.89")




                                                                  35 mm (1.38")


                                                                     IMPORTANT
                                     This picture is not to scale, therefore use the measurements provided.




3E4288 Gallagher T10 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited                                                                                                    Page 12



Document Created: 2016-08-23 12:06:34
Document Modified: 2016-08-23 12:06:34

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC