RF Test Report

FCC ID: M5LB2000

Test Report

Download: PDF
FCCID_4156766

Report Number: 68.940.16.009.01




                                                              FCC - TEST REPORT


  Report Number                                          : 68.940.16.009.01                               Date of Issue:                   November 08, 2018


 Model                                                   : BUSTER 2000; BUSTER 2000 HL; BUSTER 2000-1;
                                                           BUSTER 2000 HL-1;

 Product Type                                            : Rechargeable LED Bike Light

 Applicant                                               : Sigma Sport USA LLC

 Address                                                 : 1860B Dean St., St. Charles, IL 60174, United States

 Manufacture                                             : SHENZHEN MINJUN ELECTRONIC Technology CO., LTD.

 Address                                                 : Libang technology Park, 3rd Xitian Industrial Zone,

                                                             Guangming, New District, 518106 Shenzhen,

                                                             PEOPLE’S REPUBLIC OF CHINA.


  Test Result                                            :  Positive                    Negative



  Total pages including
  Appendices                                             : 21



TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined
in ISO 17025.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test
conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this
model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe
for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co.,
Ltd. Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and
Testing (China) Co., Ltd. Shenzhen Branch issued reports.

This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be
reproduced except in full without our written approval




 EMC_SZ_FR_23.00 FCC                                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                           Page 1 of 21
                                              Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                          District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 1 Table of Contents

  1 Table of Contents ............................................................................................................................................... 2
  2 Details about the Test Laboratory ...................................................................................................................... 3
  3 Description of the Equipment Under Test .......................................................................................................... 4
  4 Summary of Test Standards ............................................................................................................................... 5
  5 Summary of Test Results ................................................................................................................................... 6
  6 General Remarks................................................................................................................................................ 7
  7 Test setups ......................................................................................................................................................... 8
  8 Technical Requirement ....................................................................................................................................... 9
     8.1 Field strength of emissions and Restricted bands ....................................................................................... 9
     Field strength of emissions and Restricted bands ........................................................................................... 10
     8.2 Out of Band Emissions .............................................................................................................................. 13
     8.3 20dB Bandwidth ......................................................................................................................................... 18
  9 Test equipment lists .......................................................................................................................................... 20
  10 System Measurement Uncertainty ................................................................................................................. 21




 EMC_SZ_FR_23.00 FCC                                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                           Page 2 of 21
                                             Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                         District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 2 Details about the Test Laboratory

 Details about the Test Laboratory

 Test Site 1

 Company name:         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
                       Building 12&13, Zhiheng Wisdomland Business Park,
                       Nantou Checkpoint Road 2, Nanshan District,
                       Shenzhen City, 518052,
                       P. R. China

 FCC Registration      514049
 Number:

 IC Registration       10320A-1
 Number:

 Telephone:            86 755 8828 6998
 Fax:                  86 755 8828 5299




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 3 of 21
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 3 Description of the Equipment Under Test

 Description of the Equipment Under Test

 Product:                          Rechargeable LED Bike Light

 Model no.:                        BUSTER 2000

 FCC ID:                           M5LB2000

 Options and accessories:          NIL

 Ratings:                          DC 3V (1*CR2025 Button battery)

 RF Transmission                   2405MHz
 Frequency:

 Modulation:                       GFSK

 Antenna Type:                     PCB

 Antenna Gain:                     2dBi

 Description of the EUT:           The Equipment Under Test (EUT) is a Bicycle light remote
                                   controller operating at 2.4GHz

Auxiliary Equipment Used during Test:

        DESCRIPTION            MANUFACTURER                              RATINGS                       MODEL NO.(SHIELD)
               ---                         ---                                 ---                                   ---




 EMC_SZ_FR_23.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 4 of 21
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20        District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 4 Summary of Test Standards

                                   Test Standards
 FCC Part 15 Subpart C PART 15 - RADIO FREQUENCY DEVICES
 10-1-2017 Edition     Subpart C - Intentional Radiators

All the test methods were according to ANSI C63.10-2013.




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 5 of 21
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 5 Summary of Test Results

                                         Technical Requirements
 FCC Part 15 Subpart C 15.249
 Test Condition                                                                Pages           Test           Test Result
                                                                                               Site        Pass Fail N/A
 §15.207                                                                           ---          ---
 Conducted emission AC power port
 §15.205(a), §15.209(a), §15.249(a), §15.249(c)                                     9        Site 1
 Field strength of emissions and Restricted bands
 §15.249(d)                                                                        12        Site 1
 Out of band emissions
 FCC §15.215(c)                                                                    17        Site 1
 20dB bandwidth
 §15.203                                                                          See note 1
 Antenna requirement

Remark 1: N/A- Not Applicable;
Note 1: The EUT used an integral PCB antenna, which gain is 2dBi. According to §15.203, it is
considered sufficiently to comply with the provisions of this section.




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 6 of 21
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 6 General Remarks

Remarks
This submittal(s) (test report) is intended for FCC ID:M5LB2000 complies with Section,
15.205, 15.209, 15.249 of the FCC Part 15, Subpart C Rules;

BUSTER 2000-1 and BUSTER 2000 HL-1 are identical to BUSTER 2000 and BUSTER 2000
HL respectively except for battery capacity.

BUSTER 2000 HL is the same as main model: BUSTER 2000 except for mounting accessory.

So the EMC full tests were applied on BUSTER 2000, another model was deemed to fulfil the
EMC requirement without the further test.


SUMMARY:

All tests according to the regulations cited on page 5 were


 - Performed

 - Not Performed

The Equipment Under Test

 - Fulfills the general approval requirements.

 - Does not fulfill the general approval requirements.


 Sample Received Date:                        28 May, 2016

 Testing Start Date:                          28 May, 2016

 Testing End Date:                           27 June, 2016


- TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch -
 Reviewed by:                           Prepared by:                                     Tested by:




   _______________________                   _______________________                            _______________________
       Laurent Yuan                           Henry Chen                                               Louise Liu
    EMC Project Manager                    EMC Project Engineer                                     EMC Test Engineer




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 7 of 21
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 7 Test setups


7.1 Radiated test setups

Below 1GHz




Above 1GHz




 EMC_SZ_FR_23.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 8 of 21
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20        District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 8 Technical Requirement


 8.1 Field strength of emissions and Restricted bands
Test Method

   1: The EUT was place on a turn table which is 1.5m above ground plane for above 1GHz
   and 0.8m above ground for below 1GHz at 3-meter chamber room for test. The table was
   rotated 360 degrees to determine the position of the highest radiation.
   2: The EUT was set 3 meters away from the interference – receiving antenna, which was
   mounted on the top of a variable – height antenna tower.
   3: The height of antenna is varied from one meter to four meters above the ground to
   determine the maximum value of the field strength. Both horizontal and vertical
   polarizations of the antenna are set to make the measurement.
   4: For each suspected emission, the EUT was arranged to its worst case and then the
   antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned
   from 0 degrees to 360 degrees to find the maximum reading.
   5: Use the following spectrum analyzer settings According to C63.10:

   For Above 1GHz
      Span = wide enough to capture the peak level of the in-band emission and all spurious
      RBW = 1MHz, VBW≥RBW for peak measurement and VBW = 10Hz for average
      measurement, Sweep = auto, Detector function = peak, Trace = max hold.

   For Below 1GHz
   Use the following spectrum analyzer settings:
      Span = wide enough to capture the peak level of the in-band emission and all spurious
      RBW = 100 KHz, VBW≥RBW for peak measurement, Sweep = auto, Detector function
      = peak, Trace = max hold.

Note:
        1: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is
        120 KHz for Quasi-peak detection (QP) at frequency below 1GHz.
        2: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
        bandwidth is 3MHz for peak detection (PK) at frequency above 1GHz.
        3: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
        bandwidth is 3MHz for RMS Average ((duty cycle ˂ 98%) for Average detection (AV) at
        frequency above 1GHz, then the measurement results was added to a correction factor
        (20log (1/duty cycle)).
        4: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
        bandwidth is 10Hz (duty cycle ˃ 98%) for Average detection (AV) at frequency above
        1GHz.




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 9 of 21
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 Field strength of emissions and Restricted bands

Limits
According to §15.249 (a), the field strength of emissions from intentional radiators operated
within these frequency bands shall comply with the following:

                                   Field strength of fundamental Field strength of harmonics
   Fundamental frequency
                                   (millivolts/meter)            (microvolts/meter)
   902–928 MHz                     50                                                 500
   2400–2483.5 MHz                 50                                                 500
   5725–5875 MHz                   50                                                 500
   24.0–24.25 GHz                  250                                                2500

According to §15.249 (c), Field strength limits are specified at a distance of 3 meters.
According to §15.249 (d, Emissions radiated outside of the specified frequency bands, except
for harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to
the general radiated emission limits in §15.209, whichever is the lesser attenuation.
According to §15.205 Unwanted emissions falling into restricted bands in §15.205 (a) Table 7
shall comply with the limits specified in §15.209.

            Frequency               Field Strength                  Field Strength                        Detector
               MHz                       uV/m                          dBμV/m
              30-88                       100                             40                                  QP
              88-216                      150                            43.5                                 QP
             216-960                      200                             46                                  QP
             960-1000                     500                             54                                  QP
            Above 1000                    500                             54                                  AV
            Above 1000                   5000                             74                                  PK




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 10 of 21
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 Field strength of emissions and Restricted bands

According to C63.10, if the peak (or quasi-peak) measured value complies with the average limit, it is
unnecessary to perform an average measurement, so AV emission value did not show in
below table if the peak value complies with average limit.

EUT: Rechargeable LED Bike Light
M/N: BUSTER 2000
Operating Condition: Tx; 2405MHz

Below 1GHz
         Frequency      Emission Level          E-Field             Limits          Margin         Value         Corr.        Emission
           (MHz)           (dBμV/m)             Polarity         (dBμV/m)             (dB)         Type          (dB)          Type
        276.002778*          17.81                  H               46.00            28.19           QP          -21.9        Spurious
        274.332222*          17.59                  V               46.00            28.41           QP          -22.0        Spurious
        886.402222           25.71                  H               46.0             20.29           QP          -15.8        Spurious
        862.745000           25.81                  V               46.0             20.19           QP          -16.3        Spurious
      Remark:
      Corrector Factor = Antenna Factor + Cable Loss


Above 1GHz
                          Peak                      AV
         Frequency                    Factor                    E-Field        Limits        Margin       Corr.     Value         Emission
                        Emission                 Emission
                                                 (dBμV/m)       Polarity                                  (dB)      Type           Type
           (MHz)        (dBμV/m)       (dB)                                  (dBμV/m)         (dB)
        2405.000000       80.83       0.00            ---           H          114.00        33.17        -6.5       Peak       Fundamental
        2405.000000       80.83       -40.00        40.83           H           94.00        53.17        -6.5           AV     Fundamental
        2405.000000       74.95       0.00            ---           V          114.00        39.05        -6.5       Peak       Fundamental
        2405.000000       74.95       -40.00        34.95           V           94.00        59.05        -6.5           AV     Fundamental
       14013.500000       40.92       0.00            ---           H           74.00        33.08        15.1       Peak         Spurious
       14013.500000       40.92       -40.00        0.92            H           54.00        53.08        15.1           AV       Spurious
       13483.500000       44.66       0.00            ---           V           74.00        29.34        13.4       Peak         Spurious
       13483.500000       44.66       -40.00        4.66            V           54.00        49.34        13.4           AV       Spurious
       Remark:
       Corrector Factor = Antenna Factor + Cable Loss – Amplifier Gain
       Factor=20log(dutycycle), dutycycle=1.45%

Remark
1: AV Emission Level= PK Emission Level+20log(dutycycle)
2: “*” means the emission(s) appear within the restrict bands shall follow the requirement of section 15.205.
3: Below 1GHz: Corrector factor=Antenna Factor + Cable loss
4: Above 1GHz: Corrector factor=Antenna Factor + Cable loss-Amplifier Gain




 EMC_SZ_FR_23.00 FCC                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 11 of 21
                               Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20           District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01


Duty Cycle =[(0.2*5)/100] (ms) =1%
Duty Cycle Factor =20log (Duty Cycle) =-40.0




 EMC_SZ_FR_23.00 FCC                            TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 12 of 21
                                    Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 8.2 Out of Band Emissions
Test Method

   1 Use the following spectrum analyzer settings:
     Span = wide enough to capture the peak level of the in-band emission and all spurious
     RBW = 100 kHz, VBW≥RBW, Sweep = auto, Detector function = peak, Trace = max
     hold.
   2 Allow the trace to stabilize, use the peak and delta measurement to record the result.
   3 The level displayed must comply with the limit specified in this Section.


Limits
According to §15.249(d) Emissions radiated outside of the specified frequency bands, except
for harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to
the general radiated emission limits in §15.209, whichever is the lesser attenuation.




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 13 of 21
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 Out of Band Emissions

EUT: Rechargeable LED Bike Light
M/N: BUSTER 2000
Operating Condition: Tx; 2405MHz
Polarization: Horizontal


          100


           80


           60


           40


           20


              20
              1000                   1500                        2000                         2500                       3000
       Level in dBµV/m                                   Frequency in MHz


                         Frequency      MaxPeak        Limit     Margin      Height     Pol    Azimuth       Corr.
                           (MHz)        (dBµV/m)      (dBµV       (dB)        (cm)              (deg)        (dB)
                                                        /m)
                         1258.866667         33.25     74.00       40.75       154.0    H            127.0    -12.1
                         2406.200000         80.83     74.00       -6.83       154.0    H             79.0     -6.5
                         2453.866667         39.62     74.00       34.38       154.0    H             73.0     -6.3




 EMC_SZ_FR_23.00 FCC                         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 14 of 21
                                 Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20             District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 Out of Band Emissions

EUT: Rechargeable LED Bike Light
M/N: BUSTER 2000
Operating Condition: Tx; 2405MHz
Polarization: Vertical


              100


               80


               60


               40


               20


                  0
                 1000                     1500                         2000                        2500                        3000
         Level in dBµV/m
                                                                Frequency in MHz


                           Frequency     MaxPeak        Limit     Margin      Height     Pol    Azimuth       Corr.
                             (MHz)       (dBµV/m)      (dBµV       (dB)        (cm)              (deg)        (dB)
                                                         /m)
                       1255.400000            31.13     74.00       42.87       154.0    V          329.0      -12.2
                       2120.933333            28.82     74.00       45.18       154.0    V            0.0       -7.1
                       2405.800000            74.95     74.00       -0.95       154.0    V          315.0       -6.5




 EMC_SZ_FR_23.00 FCC                          TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 15 of 21
                                  Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20              District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 Out of Band Emissions

EUT: Rechargeable LED Bike Light
M/N: BUSTER 2000
Operating Condition: Tx; 2405MHz
Polarization: Horizontal


              100


               80


               60


               40


               20


                  0
                   3G                           5G          6         7       8       9    10G                                 18G
         Level in dBµV/m
                                                                 Frequency in Hz


                           Frequency      MaxPeak        Limit     Margin      Height     Pol    Azimuth       Corr.
                             (MHz)        (dBµV/m)      (dBµV       (dB)        (cm)              (deg)        (dB)
                                                          /m)
                        4811.500000           44.69      74.00       29.31        154.0   H           76.0       1.9
                        7505.000000           39.08      74.00       34.92        154.0   H           76.0       6.4
                       14013.500000           40.92      74.00       33.08        154.0   H          190.0      15.1




 EMC_SZ_FR_23.00 FCC                          TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 16 of 21
                                  Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20              District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 Out of Band Emissions

EUT: Rechargeable LED Bike Light
M/N: BUSTER 2000
Operating Condition: Tx; 2405MHz
Polarization: Vertical


             100


              80


              60


              40


              20


                 0
                  3G                        5G          6         7       8       9    10G                                 18G
          Level in dBµV/m
                                                             Frequency in Hz


                       Frequency      MaxPeak        Limit     Margin      Height     Pol    Azimuth       Corr.
                         (MHz)        (dBµV/m)      (dBµV       (dB)        (cm)              (deg)        (dB)
                                                      /m)
                       4811.500000        46.86      74.00       27.14        154.0   V          312.0       1.9
                       7217.500000        43.39      74.00       30.61        154.0   V          356.0       5.1
                      13483.500000        44.66      74.00       29.34        154.0   V          359.0      13.4




 EMC_SZ_FR_23.00 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 17 of 21
                              Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20          District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 8.3 20dB Bandwidth
Test Method
1.    Check the calibration of the measuring instrument using either an internal calibrator or a
      known signal from an external generator.
2.     Position the EUT without connection to measurement instrument. Turn on the EUT and
      connect it to measurement instrument. Then set it to any one convenient frequency
      within its operating range. Set a reference level on the measuring instrument equal to
      the highest peak value.
3.    Measure the frequency difference of two frequencies that were attenuated 20 dB from
      the reference level. Record the frequency difference as the emission bandwidth.

Limits:
According to 15.215 (c) Intentional radiators operating under the alternative provisions to the
general emission limits, as contained in §§ 15.217 through 15.257 and in Subpart E of this
part, must be designed to ensure that the 20 dB bandwidth of the emission, or whatever
bandwidth may otherwise be specified in the specific rule section under which the equipment
operates, is contained within the frequency band designated in the rule section under which
the equipment is operated. The requirement to contain the designated bandwidth of the
emission within the specified frequency band includes the effects from frequency sweeping,
frequency hopping and other modulation techniques that may be employed as well as the
frequency stability of the transmitter over expected variations in temperature and supply
voltage. If a frequency stability is not specified in the regulations, it is recommended that the
fundamental emission be kept within at least the central 80% of the permitted band in order to
minimize the possibility of out-of-band operation.




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 18 of 21
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 20dB Bandwidth & 99% Occupied Bandwidth

                 Frequency                  20dB Bandwidth                         99% Bandwidth                   Limit
                    MHz                          KHz                                    kHz                        kHz
                    2405                         2706                                    --                          --




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 19 of 21
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 9 Test equipment lists

                                             List of Test Instruments

                                                                                                                      CAL. DUE
             DESCRIPTION              MANUFACTURER                  MODEL NO.              SERIAL NO.
                                                                                                                       DATE
      C     Signal Generator          Rohde & Schwarz                 SMB100A                  108272                 2016-7-24
             Signal Analyzer          Rohde & Schwarz                   FSV40                  101030                 2016-7-24
              Vector Signal           Rohde & Schwarz                                          105324                 2016-7-24
                                                                      SMU 200A
                Generator
                                                                     OSP120/OS            101226/10085
            RF Switch Module          Rohde & Schwarz                                                                 2016-7-24
                                                                      P-B157                   1
            EMI Test Receiver         Rohde & Schwarz                   ESR 26                 101269                 2016-7-24
     RE        Trilog Super
             Broadband Test              Schwarzbeck                 VULB 9163                    707                 2016-8-14
                 Antenna
              Horn Antenna            Rohde & Schwarz                   HF907                  102294                 2016-7-24
              Pre-amplifier           Rohde & Schwarz                   SCU 18                 102230                 2016-7-24
            3m Semi-anechoic                                                                                          2019-5-29
                                                TDK                     9X6X6                     ----
                chamber



C - Conducted RF tests
   20dB bandwidth and 99% Occupied Bandwidth
   Dwell Time




 EMC_SZ_FR_23.00 FCC                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 20 of 21
                               Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20           District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.16.009.01




 10 System Measurement Uncertainty

For a 95% confidence level, the measurement expanded uncertainties for defined systems, in
accordance with the recommendations of ISO 17025 were:

                                  System Measurement Uncertainty
                           Items                                                           Extended Uncertainty
                                                                                       U=4.32dB (30MHz-1GHz)
           RE                  Field strength (dBμV/m)
                                                                                       U=2.27dB (1GHz-25GHz)
         CE                Disturbance Voltage (dBμV)                                         U=2.4dB
    Bandwidth test                     --                                                      1*10-9
  Conducted emission                   --                                                      2.4dB




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 21 of 21
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2019-01-18 10:36:39
Document Modified: 2019-01-18 10:36:39

© 2024 FCC.report