Test Report

FCC ID: M45-46066

Test Report

Download: PDF
FCCID_2086460

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




                                                   FCC TEST REPORT

                                                                FOR

                          Estes-Cox Corporation d/b/a Estes Industries and Cox

                                                              Proto X

                                                   Model No.: ESTE4606



Prepared for                            :    Estes-Cox Corporation d/b/a Estes Industries and Cox
Address                                 :    1295 H Street, Penrose, Colorado 81240 United States


Prepared by                             : Shenzhen LCS Compliance Testing Laboratory Ltd
Address                                 : 1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue,
                                          Bao’an District, Shenzhen, Guangdong, China


Date of receipt of test sample          :    September 16, 2013
Number of tested samples                :    1
Serial number                           :    Prototype
Date of Test                            :    September 16, 2013 - September 26, 2013
Date of Report                          :    September 26, 2013




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 1 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F



                                                     FCC TEST REPORT
                                         FCC CFR 47 PART 15 C(15.249): 2012

 Report Reference No. ............... : LCS130916414F
 Date of Issue ................................. : September 26, 2013
 Testing Laboratory Name.......... : Shenzhen LCS Compliance Testing Laboratory Ltd.
 Address ......................................... : 1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue,
                                                     Bao’an District, Shenzhen, Guangdong, China
 Testing Location/ Procedure......... : Full application of Harmonised standards ■
                                                 Partial application of Harmonised standards □
                                                 Other standard testing method □
 Applicant’s Name ....................... : Estes-Cox Corporation d/b/a Estes Industries and Cox
 Address ......................................... : 1295 H Street, Penrose, Colorado 81240 United States
 Test Specification
 Standard ........................................ : FCC CFR 47 PART 15 C(15.249): 2012 / RSS-210 Issue 8 /
                                                 RSS-Gen Issue 3
 Test Report Form No.................... : LCSEMC-1.0
 TRF Originator ............................. : Shenzhen LCS Compliance Testing Laboratory Ltd.
 Master TRF .................................. : Dated 2011-03
 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
 This publication may be reproduced in whole or in part for non-commercial purposes as long as the
 Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source
 of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and
 will not assume liability for damages resulting from the reader's interpretation of the reproduced
 material due to its placement and context.

 Test Item Description. ................ : Proto X
 Trade Mark ................................... : N/A
 Model/ Type reference.................. : ESTE4606
 Ratings .......................................... : DC 3.0V by 2*AAA batteries
 Result ......................................... : Positive

           Compiled by:                                   Supervised by:                                 Approved by:


    Leo Lee/ File administrators                 Fox Zhang/ Technique principal                       Gavin Liang/ Manager

   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 2 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




                                             FCC -- TEST REPORT

                                                                                                September 26, 2013
     Test Report No. : LCS130916414F                                                                  Date of issue




     Type / Model........................... : ESTE4606


     EUT......................................... : Proto X

     Applicant............................... : Estes-Cox Corporation d/b/a Estes Industries and Cox

     Address..................................    : 1295 H Street, Penrose, Colorado 81240 United States

     Telephone............................... : /
     Fax.......................................... : /

     Manufacturer........................ : Shenzhen Hubsan Technology Co., Ltd.
     Address................................... : Rm407, Municipal Service Building, Hong Li Road west, Futian
                                                  District, Shenzhen, China

     Telephone............................... : /
     Fax.......................................... : /


     Factory................................... : Shenzhen Hubsan Technology Co., Ltd.
     Address................................... : Rm407, Municipal Service Building, Hong Li Road west, Futian
                                                  District, Shenzhen, China
     Telephone............................... : /
     Fax.......................................... : /




                            Test Result                                                           Positive
     The test report merely corresponds to the test sample.
     It is not permitted to copy extracts of these test result without the written permission of the test
     laboratory.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 3 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                            FCC ID: M45-46066                      Report No.: LCS130916414F




                                                           TABLE OF CONTENTS
  1. GENERAL INFORMATION ..................................................................................................... 5
     1.1. Description of Device (EUT) .............................................................................................................. 5
     1.2. Host System Configuration List and Details ....................................................................................... 5
     1.3. External I/O ......................................................................................................................................... 5
     1.4. Description of Test Facility ................................................................................................................. 6
     1.5. Statement of the measurement uncertainty .......................................................................................... 6
     1.6. Measurement Uncertainty.................................................................................................................... 6
     1.7. Description Of Test Modes ................................................................................................................. 7
  2. TEST METHODOLOGY ........................................................................................................... 8
     2.1. EUT Configuration .............................................................................................................................. 8
     2.2. EUT Exercise ....................................................................................................................................... 8
     2.3. General Test Procedures ...................................................................................................................... 8
  3. CONNECTION DIAGRAM OF TEST SYSTEM ................................................................... 9
     3.1. Justification ......................................................................................................................................... 9
     3.2. EUT Exercise Software ....................................................................................................................... 9
     3.3. Special Accessories ............................................................................................................................. 9
     3.4. Block Diagram/Schematics ................................................................................................................. 9
     3.5. Equipment Modifications .................................................................................................................... 9
     3.6. Test Setup ............................................................................................................................................ 9
  4. SUMMARY OF TEST RESULTS ........................................................................................... 10
  5. ANTENNA REQUIREMENT .................................................................................................. 11
     5.1. Standard Applicable .......................................................................................................................... 11
     5.2. Antenna Connected Construction ...................................................................................................... 11
  6. RADIATED EMISSION MEASUREMENT .......................................................................... 12
     6.1. Standard Applicable .......................................................................................................................... 12
     6.2. Measuring Instruments and Setting ................................................................................................... 12
     6.3. Test Procedure ................................................................................................................................... 13
     6.4. Test Equipment List and Details ....................................................................................................... 14
     6.5. Block Diagram of Test Setup ............................................................................................................ 14
     6.6. Test Results ....................................................................................................................................... 15
  7. BAND EDGES MEASUREMENT .......................................................................................... 23
     7.1. Standard Applicable .......................................................................................................................... 23
     7.2. Test Equipment List and Details ....................................................................................................... 23
     7.3. Block Diagram of Test Setup ............................................................................................................ 23
     7.4. Test Procedure ................................................................................................................................... 23
     7.5. Test Results ....................................................................................................................................... 24
  8. 20 DB BANDWIDTH MEASUREMENT ............................................................................... 26
     8.1. Standard Applicable .......................................................................................................................... 26
     8.2. Test Equipment List and Details ....................................................................................................... 26
     8.3. Block Diagram of Test Setup ............................................................................................................ 26
     8.4. Test Procedure ................................................................................................................................... 26
     8.5. Test Results ....................................................................................................................................... 27
  9. MANUFACTURER/ APPROVAL HOLDER DECLARATION ......................................... 29




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 4 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




      1. GENERAL INFORMATION
            1.1. Description of Device (EUT)

              EUT                               : Proto X


              Model Number                      : ESTE4606

              Power Supply                      : DC 3.0V by 2*AAA batteries

              Frequency Range                   : 2410.00-2465.00MHz, (Channel Number: 12, Channel
                                                  Frequency=2410+5*(K-1), K=1, 2, 3 ……12)


              Modulation Technology : GFSK

              Channel Number                    : 12


              Channel Spacing                   : 5MHz

              Antenna Type and Gain : PCB Antenna, 1.8dBi(Max.)


            1.2. Host System Configuration List and Details

          Manufacturer            Description               Model             Serial Number                Certificate

                  --                     --                    --                     --                         --


            1.3. External I/O

               I/O Port Description                             Quantity                                 Cable

                            --                                       --                                     --




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 5 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




            1.4. Description of Test Facility
                 Site Description
                 EMC Lab.                     : Accredited by CNAS, June 04, 2010
                                                 The Certificate Registration Number. is L4595.
                                                 Accredited by FCC, July 14, 2011
                                                 The Certificate Registration Number. is 899208.
                                                 Accredited by Industry Canada, May. 02, 2011
                                                 The Certificate Registration Number. is 9642A-1

            1.5. Statement of the measurement uncertainty
                   The data and results referenced in this document are true and accurate. The reader is
                   cautioned that there may be errors within the calibration limits of the equipment and
                   facilities. The measurement uncertainty was calculated for all measurements listed in
                   this test report acc. To CISPR 16 – 4 “Specification for radio disturbance and immunity
                   measuring apparatus and methods – Part 4: Uncertainty in EMC Measurements” and is
                   documented in the LCS quality system acc. To DIN EN ISO/IEC 17025. Furthermore,
                   component and process variability of devices similar to that tested may result in
                   additional deviation. The manufacturer has the sole responsibility of continued
                   compliance of the device.

            1.6. Measurement Uncertainty
                                Test Item                      Frequency Range                      Uncertainty                Note
                                                                 9KHz~30MHz                          ±3.10dB                    (1)
                                                               30MHz~200MHz                          ±2.96dB                    (1)
                        Radiation Uncertainty :
                                                              200MHz~1000MHz                         ±3.10dB                    (1)
                                                                1GHz~26.5GHz                         ±4.00dB                    (1)
                      Conduction Uncertainty :                 150kHz~30MHz                          ±1.63dB                    (1)
                        Power disturbance    :                 30MHz~300MHz                          ±1.60dB                    (1)

                  (1). This uncertainty represents an expanded uncertainty expressed at approximately the
                     95% confidence level using a coverage factor of k=2.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 6 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




            1.7. Description Of Test Modes
                   The EUT operates in the unlicensed ISM band at 2.4GHz. The following operating
                   modes were applied for the related test items. And the new battery is used during the
                   measurement.
                   The EUT received DC 3.0V power from 2*AAA batteries which are new and full
                   power.
                   All test modes were tested, only the result of the worst case was recorded in the report.

                   The EUT is considered a portable unit; it was pre-tested on the positioned of each 3 axis.
                   The worst case was found positioned on X-plane. Therefore only the test data of this
                   X-plane was used for radiated emission measurement test.

                                 Mode of Operations                   Transmitting Frequency
                                                                             (MHz)
                                                                               2410
                                   GFSK                                        2435
                                                                               2465
                                                 For Conducted Emission
                                Test Mode                                      N/A
                                                  For Radiated Emission
                                Test Mode                                   TX Mode
                   Note: The EUT is designed to use DC 3.0V 2*AAA batteries for power supply, so the
                   conducted emission testing is not applicable.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 7 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




      2. TEST METHODOLOGY
                   All measurements contained in this report were conducted with ANSI C63.4-2003,
                   American National Standard for Methods of Measurement of Radio-Noise Emissions
                   from Low-Voltage Electrical and Electronic Equipment in the range of 9 kHz to 40
                   GHz.
                   The radiated testing was performed at an antenna-to-EUT distance of 3 meters. All
                   radiated and conducted emissions measurement was performed at Shenzhen LCS
                   Compliance Testing Laboratory Ltd..

            2.1. EUT Configuration
                   The EUT configuration for testing is installed on RF field strength measurement to meet
                   the Commissions requirement and operating in a manner that intends to maximize its
                   emission characteristics in a continuous normal application.

            2.2. EUT Exercise
                   The EUT was operated in the engineering mode to fix the TX frequency that was for the
                   purpose of the measurements.
                   According to its specifications, the EUT must comply with the requirements of the
                   Section 15.203, 15.205, 15.207, 15.209 and 15.249 under the FCC Rules Part 15
                   Subpart C and RSS-210.

            2.3. General Test Procedures
                   2.3.1 Conducted Emissions(N/A)
                   The EUT is placed on the turntable, which is 0.8 m above ground plane. According to
                   the requirements in Section 13.1.4.1 of ANSI C63.4 Conducted emissions from the
                   EUT measured in the frequency range between 0.15 MHz and 30MHz using Quasi-peak
                   and average detector modes.
                   2.3.2 Radiated Emissions
                   The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable
                   shall rotate 360 degrees to determine the position of maximum emission level. EUT is
                   set 3m away from the receiving antenna, which varied from 1m to 4m to find out the
                   highest emission. And also, each emission was to be maximized by changing the
                   polarization of receiving antenna both horizontal and vertical. In order to find out the
                   maximum emissions, exploratory radiated emission measurements were made according
                   to the requirements in Section 13.1.4.1 of ANSI C63.4




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 8 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




      3. CONNECTION DIAGRAM OF TEST SYSTEM

            3.1. Justification
                   The system was configured for testing in a continuous transmit condition.


            3.2. EUT Exercise Software
                   N/A


            3.3. Special Accessories
                   N/A


            3.4. Block Diagram/Schematics
                   Please refer to the related document


            3.5. Equipment Modifications
                   Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on
                   the EUT.


            3.6. Test Setup
                   Please refer to the test setup photo.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 9 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




      4. SUMMARY OF TEST RESULTS

                FCC Rules                       IC Rules                     Description Of Test                  Result

                  §15.203                      RSS-Gen                   Antenna Requirement                   Compliant

                §15.207(a)                     RSS-Gen                   Conduction Emissions                      N/A
                §15.205(a),
                §15.209(a),                    RSS-210                    Radiated Emissions
                                                                                                               Compliant
                §15.249(a),                  (A2.9&A8.4)                    Measurement
                §15.249(c)
                  §15.249                  RSS-210(A8.5)              Band Edges Measurement                   Compliant

            §15.249, §15.215                   RSS-210                      20 dB Bandwidth                    Compliant




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 10 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




      5. ANTENNA REQUIREMENT

            5.1. Standard Applicable
                   According to §15.203 & RSS-Gen, Antenna requirement.
                   An intentional radiator shall be designed to ensure that no antenna other than that
                   furnished by the responsible party shall be used with the device. The use of a
                   permanently attached antenna or of an antenna that uses a unique coupling to the
                   intentional radiator shall be considered sufficient to comply with the provisions of this
                   Section. The manufacturer may design the unit so that a broken antenna can be
                   re-placed by the user, but the use of a standard antenna jack or electrical connector is
                   prohibited. This requirement does not apply to carrier current devices or to devices
                   operated under the provisions of Sections 15.211, 15.213, 15.217, 15.219, or 15.221.
                   Further, this requirement does not apply to intentional radiators that must be
                   professionally installed, such as perimeter protection systems and some field
                   disturbance sensors, or to other intentional radiators which, in accordance with Section
                   15.31(d), must be measured at the installation site. However, the installer shall be
                   responsible for ensuring that the proper antenna is employed so that the limits in this
                   Part are not exceeded.


            5.2. Antenna Connected Construction
                   The directional gains of antenna used for transmitting is 1.8dBi(Max.), and EUT is
                   equipped with an onboard PCB antenna and no consideration of replacement. Please see
                   EUT photo for details.

                   Result: Compliance.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 11 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




      6. RADIATED EMISSION MEASUREMENT

            6.1. Standard Applicable
                1.     Emissions radiated outside of the specified frequency bands, except for harmonics,
                       shall be attenuated by at least 50 dB below the level of the fundamental or to the
                       general radiated emission limits in §15.209, whichever is the lesser attenuation.
                2.     20dBc in any 100 kHz bandwidth outside the operating frequency band. In case the
                       emission fall within the restricted band specified on 15.205(a), then the 15.209(a) and
                       15.249 limit in the table below has to be followed.

                      Fundamental            Field Strength of fundamental               Field Strength of harmonics
                       Frequency                    (millivolts/meter)                        (microvolts/meter)
                      902-928MHz                             50                                        500
                  2400-2483.5MHz                             50                                        500

                     5725-5875MHz                            50                                        500

                     24.0-24.25GHz                          250                                       2500

                         Frequencies                       Field Strength                    Measurement Distance
                            (MHz)                        (microvolts/meter)                        (meters)
                         0.009~0.490                        2400/F(KHz)                                  300
                         0.490~1.705                        24000/F(KHz)                                 30
                          1.705~30.0                               30                                    30
                             30~88                                100                                     3
                            88~216                                150                                     3
                           216~960                                200                                     3
                          Above 960                               500                                     3



            6.2. Measuring Instruments and Setting
                     Please refer to section 5 of equipments list in this report. The following table is the
                     setting of spectrum analyzer and receiver.

                 Spectrum Parameter                                 Setting
                 Attenuation                                        Auto
                 Start ~ Stop Frequency                             9kHz~150kHz / RB 200Hz for QP
                 Start ~ Stop Frequency                             150kHz~30MHz / RB 9kHz for QP

                 Start ~ Stop Frequency                             30MHz~1000MHz / RB 120kHz for QP




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 12 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F


               Spectrum Parameter                                      Setting
               Attenuation                                             Auto
               Start Frequency                                         1000 MHz
               Stop Frequency                                          10th carrier harmonic
               RB / VB (Emission in restricted band)                   1MHz / 1MHz for Peak, 1 MHz / 10Hz for Average
               RB / VB (Emission in non-restricted band)               1000KHz / 1000KHz for peak



            6.3. Test Procedure
                1. Configure the EUT according to ANSI C63.4. The EUT was placed on the top of the
                   turntable 0.8 meter above ground. The phase center of the receiving antenna mounted on
                   the top of a height-variable antenna tower was placed 3 meters far away from the
                   turntable.

                2. Power on the EUT and all the supporting units. The turntable was rotated by 360
                   degrees to determine the position of the highest radiation.

                3. The height of the broadband receiving antenna was varied between one meter and four
                   meters above ground to find the maximum emissions field strength of both horizontal
                   and vertical polarization.

                4. For each suspected emissions, the antenna tower was scan (from 1 m to 4 m) and then
                   the turntable was rotated (from 0 degree to 360 degrees) to find the maximum reading.

                5. Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with
                   specified bandwidth under Maximum Hold Mode.

                6. For emissions above 1GHz, use 1MHz VBW and RBW for peak reading. Then 1MHz
                   RBW and 10Hz VBW for average reading in spectrum analyzer.

                7. When the radiated emissions limits are expressed in terms of the average value of the
                   emissions, and pulsed operation is employed, the measurement field strength shall be
                   determined by averaging over one complete pulse train, including blanking intervals, as
                   long as the pulse train does not exceed 0.1 seconds. As an alternative (provided the
                   transmitter operates for longer than 0.1 seconds) or in cases where the pulse train
                   exceeds 0.1 seconds, the measured field strength shall be determined from the average
                   absolute voltage during a 0.1 second interval during which the field strength is at its
                   maximum value.

                8. If the emissions level of the EUT in peak mode was 3 dB lower than the average limit
                   specified, then testing will be stopped and peak values of EUT will be reported,
                   otherwise, the emissions which do not have 3 dB margin will be repeated one by one
                   using the quasi-peak method for below 1GHz.

                9. For testing above 1GHz, the emissions level of the EUT in peak mode was lower than
                   average limit (that means the emissions level in peak mode also complies with the limit
                   in average mode), then testing will be stopped and peak values of EUT will be reported,
                   otherwise, the emissions will be measured in average mode again and reported.
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 13 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




            6.4. Test Equipment List and Details

                   Equipment               Manufacturer             Model No.           Serial No.         Last Cal.       Next Cal.
                    Spectrum
                                               Agilent               E4407B           MY41440754          2013-07-16 2014-07-15
                     Analyzer
                  Test Receiver         Rohde & Schwarz              ESCI                101142           2013-06-18      2014-06-17
                  Loop antenna               EMCO                    6502               0042963           2013-06-18      2014-06-17
                 Log per Antenna          Schwarzbeck              VULB9163            9163-470           2013-06-10      2014-06-09
                  Horn-antenna          ETS.LINDGREN                 3115              00034771           2013-06-10      2014-06-09
                  Horn Antenna          SCHWARZBECK                BBHA9170          BBHA9170154          2013-06-10      2014-06-09




            6.5. Block Diagram of Test Setup
                   For radiated emissions below 30MHz




                   For radiated emissions above 30MHz
                                                                                                     Antenna
                                                                                                      tower


                                          3m                                                         Bi-log
                                                                                                    antenna
                 EUT
                                                 4m
                                                                                                   Spectrum
                                                                                                   analyzer


                         Turntable                     1m
                                       0.8m




            Reference ground plane




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 14 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F


                                                                                             Antenna
                                                                                              tower


                                   3m                                                       Horn
                                                                                           antenna
              EUT
                                           4m
                                                                                            Spectrum
                                                                                            analyzer


                   Turntable                    1m
                                  0.8m
                                                                                                Pre-amp



                    Above 10 GHz shall be extrapolated to the specified distance using an extrapolation
                    factor of 20 dB/decade form 3m to 1.5m.
                    Distance extrapolation factor = 20 log (specific distanc [3m] / test distance [1.5m])
                    (dB);
                    Limit line = specific limits (dBuV) + distance extrapolation factor [6 dB].



            6.6. Test Results
                    Results of Radiated Emissions (9kHz~30MHz)

                   Frequency                  Level                Over Limit             Over Limit
                                                                                                                   Remark
                     (MHz)                   (dBuV)                  (dB)                  (dBuV)
                                                                                                                  See Note

                    Note:
                    The amplitude of spurious emissions which are attenuated by more than 20 dB below
                    the permissible value has no need to be reported.
                    Distance extrapolation factor = 40 log (specific distance / test distance) (dB);
                    Limit line = specific limits (dBuV) + distance extrapolation factor.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 15 of 29




,tontaniae


£ kb d P k dg




                4   —}~

                     }/::
                          ‘   <_uen

                              Fromencyaite
                                             =r27
©oull


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F

                   Results for Radiated Emissions (Above 1GHz)




                                         Field Strength Of Fundamental
  Frequency                  Measure Result    Measure Result    Peak Limit                           AVG Limit
                   Pol.                                                                                                     Result
    (MHz)                    (PK, dBuV/m)     (AVG, dBuV/m)      (dBuV/m)                             (dBuV/m)
     2410            H           86.29              81.61           114                                  94                   Pass
     2410            V           85.22              80.43           114                                  94                   Pass


   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 19 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




                                         Field Strength Of Fundamental
  Frequency                  Measure Result    Measure Result    Peak Limit                           AVG Limit
                   Pol.                                                                                                     Result
    (MHz)                    (PK, dBuV/m)     (AVG, dBuV/m)      (dBuV/m)                             (dBuV/m)
     2435            H           84.12              79.86           114                                  94                   Pass
     2435            V           83.97              79.19           114                                  94                   Pass



   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 20 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




                                         Field Strength Of Fundamental
  Frequency                  Measure Result    Measure Result    Peak Limit                           AVG Limit
                   Pol.                                                                                                     Result
    (MHz)                    (PK, dBuV/m)     (AVG, dBuV/m)      (dBuV/m)                             (dBuV/m)
     2465            H           84.93              79.05           114                                  94                   Pass
     2465            V           83.90              78.43           114                                  94                   Pass



   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 21 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F



      Notes:
            1. Measuring frequencies from 9k~10th harmonic (ex. 26GHz), No emission found between
               lowest internal used/generated frequency to 30MHz.
            2. Radiated emissions measured in frequency range from 9k~10th harmonic (ex. 26GHz)
               were made with an instrument using Peak detector mode.
            3. No emission was be recorded above 18GHz means the reading of emissions are attenuated
               more than 20dB below the permissible limits or the field strength is too small to be
               measured.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 22 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                             FCC ID: M45-46066             Report No.: LCS130916414F




      7. BAND EDGES MEASUREMENT

            7.1. Standard Applicable
                     Emissions radiated outside of the specified frequency bands, except for harmonics,
                     shall be attenuated by at least 50 dB below the level of the fundamental or to the
                     general radiated emission limits in Section 15.209, whichever is the lesser attenuation.

            7.2. Test Equipment List and Details
                 Equipment              Manufacturer              Model No.           Serial No.        Last Cal.      Next Cal.
                  Spectrum
                                            Agilent                E4407B           MY41440754 2013-07-16 2014-07-15
                  Analyzer
               Test Receiver         Rohde & Schwarz                 ESCI               101142        2013-06-18 2014-06-17
               Test Receiver         Rohde & Schwarz                 ESPI               101840        2013-06-18 2014-06-17
               Loop antenna                 EMCO                     6502              0042963        2013-06-18 2014-06-17
             Log per Antenna            Schwarzbeck              VULB9163             9163-470        2013-06-10 2014-06-09
               Horn-antenna           ETS.LINDGREN                   3115             00034771        2013-06-10 2014-06-09
                                                                                   BBHA917015
               Horn Antenna          SCHWARZBECK                 BBHA9170                             2013-06-10 2014-06-09
                                                                                           4
            7
            .3. Block Diagram of Test Setup

                                                                                                    Antenna
                                                                                                     tower


                                         3m                                                         Horn
                                                                                                   antenna
                   EUT
                                                 4m
                                                                                                   Spectrum
                                                                                                   analyzer


                        Turntable                     1m
                                       0.8m
                                                                                                      Pre-amp




            7.4. Test Procedure
                     The EUT is placed on a turntable, which is 0.8m above the ground plane. The turntable
                     shall be rotated for 360 degrees to determine the position of maximum emission level.
                     EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find
                     out the highest emission. Set the spectrum analyzer in the following setting in order to
                     capture the lower and upper band-edges of the emission:
                                   Peak: RBW=VBW=1MHz / Sweep=AUTO
                      Repeat the procedures until the peak versus polarization are measured.
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 23 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F



            7.5. Test Results




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 24 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 25 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




      8. 20 DB BANDWIDTH MEASUREMENT

            8.1. Standard Applicable
                     According to §15.215 & RSS-210.

            8.2. Test Equipment List and Details

                 Equipment              Manufacturer              Model No.           Serial No.        Last Cal.      Next Cal.
                  Spectrum
                                            Agilent                E4407B           MY41440754 2013-07-16 2014-07-15
                  Analyzer
                 DC Filter                   MPE                   23872C                N/A          2013-06-10 2014-06-09

            8.3. Block Diagram of Test Setup

                                                                                     Spectrum Analyzer



                                   EUT


                                               DC Filter

            8.4. Test Procedure
                     Use the following spectrum analyzer settings:
                     Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping
                     channel
                     RBW  1% of the 20 dB bandwidth
                     VBW  RBW
                     Sweep = auto
                     Detector function = peak
                     Trace = max hold
                     The EUT should be transmitting at its maximum data rate. Allow the trace to stabilize.
                     Use the marker-to-peak function to set the marker to the peak of the emission. Use the
                     marker-delta function to measure 20 dB down one side of the emission. Reset the
                     marker-delta function, and move the marker to the other side of the emission, until it is
                     (as close as possible to) even with the reference marker level. The marker-delta
                     reading at this point is the 20 dB bandwidth of the emission. If this value varies with
                     different modes of operation (e.g., data rate, modulation format, etc.), repeat this test
                     for each variation. The limit is specified in one of the subparagraphs of this Section.
                     Submit this plot(s).


   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 26 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F



            8.5. Test Results




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 27 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 28 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: M45-46066              Report No.: LCS130916414F




      9. MANUFACTURER/ APPROVAL HOLDER DECLARATION

           The following identical model(s):

                              --                                      --                                      --

           Belong to the tested device:

            Product description                     : Proto X
           Model name                               : ESTE4606

            Remark: No additional models were tested.




                                   ------------THE END OF REPORT----------


   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 29 of 29



Document Created: 2013-09-29 14:31:17
Document Modified: 2013-09-29 14:31:17

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC