Test report

FCC ID: LH8RP-S435

Test Report

Download: PDF
FCCID_128275

                                                                                    FCC ID: LH8RP—S435

    2) EMCC                                                                                     PAGE 1 of 12
   ‘ DR. RASEK


                      TEST REPORT # EMCC—950295A0B, 2000—NOV—21


 EQUIPMENT UNDER TEST:
        Trade Name:                             $435
        Model:                                  RPS435000.0US
        Serial No:                              None
        Equipment Category:                     Receiver
        Manufacturer:                           CARDIN ELETTRONICA SPA
        Address:                                Via Raffaello 36
                                                31020 S. Vendemiano (TV)
                                                Italy

        Phone:                                  +39—0438—401818
        Fax:                                    +39—0438—401831

 RELEVANT STANDARD:                             47 CFR Part 15B — Unintentional Radiators


 MEASUREMENT PROCEDURE USED:

        [X Anisi C63.4—1992              [] FCC/OET MP—4 (1987)          [_] Other


 TEST REPORT PREPARED BY:
        Reinhard Sauerschell
        EMCC DR. RASEK
        Moggast 72—74
        91320 Ebermannstadt
        Germany
        Phone: +49 9194 9016
        Fax: +49 9194 8125
        E—mail: r.sauerschell@emcce.de


 TEST PERSONNEL:                                        SIGNATURE OF THE COMPANY OFFICIAL:
        Reinhard Sauerschell


                                                 M
                                                           Dr. Werner G. RaSsek
                                                           — President—




EMCC DR. RASEK                               RADIO LABORATORIES                   Telephone:        +49—9194—9016
Moggast 72—74                                 EMC LABORATORIES                    Telefax:          +49—9194—8125
91320 Ebermannstadt                                   e                           Mail:        emc.cons@emecc.de
Germany                                               Rat cssz                    Web:          http://www.emee.de

FCC Registration # 90566                        TTI—P—G 094/94
                                                TTI—P—G 074/95
fee_RPS435.doc


                                                                                                                                                         FCC ID: LH8RP-S435
                                                                                                                                     Test Report #EMCC-950295AOB
                                                                                                                                                        Page 2 of 12
                                                                                                                                           Issue Date: 2000-NOV-21
        TEST OF CARDIN ELETTRONICA SPA S435 MODEL RPS435000.0US TO 47 CFR PART 15B - UNINTENTIONAL RADIATORS


CONTENTS                                                                                                                                                                                         Page


1 GENERAL INFORMATION ..................................................................................................................................................................... 3
    1.1 Purpose........................................................................................................................................................................................ 3
    1.2 Limits and Reservations............................................................................................................................................................. 3
    1.3 Test Location............................................................................................................................................................................... 3
    1.4 Manufacturer ............................................................................................................................................................................... 3
    1.5 Dates ............................................................................................................................................................................................ 3
2 PRODUCT DESCRIPTION...................................................................................................................................................................... 4
    2.1 Equipment Under Test (EUT) ..................................................................................................................................................... 4
    2.2 Configuration and Peripherals of EUT ...................................................................................................................................... 4
    2.3 Mode of Operation During Testing ............................................................................................................................................ 4
    2.4 Modifications Required for Compliance.................................................................................................................................... 4
3 TEST RESULTS SUMMARY .................................................................................................................................................................. 5
4 CONDUCTED EMISSIONS TESTS ........................................................................................................................................................ 6
    4.1 Regulation.................................................................................................................................................................................... 6
    4.2 Test Equipment ........................................................................................................................................................................... 6
    4.3 Test Procedures .......................................................................................................................................................................... 6
    4.4 Test Results................................................................................................................................................................................. 7
5 RADIATED EMISSIONS TEST ............................................................................................................................................................... 8
    5.1 Regulation.................................................................................................................................................................................... 8
    5.2 Test Equipment ........................................................................................................................................................................... 9
    5.3 Test Procedures ........................................................................................................................................................................ 10
    5.4 Field Strength Calculation........................................................................................................................................................ 10
    5.5 Test Results............................................................................................................................................................................... 11
6 MISCELLANEOUS COMMENTS AND NOTES.................................................................................................................................... 12
7 LIST OF ANNEXES............................................................................................................................................................................... 12




FCC_RPS435.DOC


                                                                                FCC ID: LH8RP-S435
                                                                      Test Report #EMCC-950295AOB
                                                                                         Page 3 of 12
                                                                            Issue Date: 2000-NOV-21
    TEST OF CARDIN ELETTRONICA SPA S435 MODEL RPS435000.0US TO 47 CFR PART 15B - UNINTENTIONAL RADIATORS



1 GENERAL INFORMATION

1.1 Purpose
The purpose of this report is to show compliance to the FCC regulations for unintentional radiators
operating under section 15.101 ff. of the Code of Federal Regulations title 47.


1.2 Limits and Reservations
The test results in this report apply only to the particular Equipment Under Test (EUT) as declared in this
report.
This test report shall not be reproduced except in full without the written permission of EMCC DR.
RAŠEK.


1.3 Test Location
Company Name:             EMCC DR. RAŠEK
Street:                   Moggast 72-74
City:                     91320 Ebermannstadt
Country:                  Germany
Laboratory:               Test Laboratory of EMCC DR. RAŠEK
                          FCC Registration Number: 90566
                          This site has been fully described in a report submitted to the FCC, and
                          accepted in the letter dated February 09, 2000 Registration Number 90566.
Phone:                    +49-9194-9016
Fax:                      +49-9194-8125
E-Mail:                   emc.cons@emcc.de
Web:                      www.emcc.de


1.4 Manufacturer
Company Name:             CARDIN ELETTRONICA SPA
Street:                   Via Raffaello 36
City:                     31020 S. Vendemiano (TV)
Country:                  Italy

Name for contact purposes:     Mr. Maurizio Terruso
Phone:                  +39-0438-401818
Fax:                    +39-0438-401831
E-mail:                 cert@cardin.it


1.5 Dates
Date of receipt of EUT:   CW 42/2000
Test date:                CW 42-43/2000




FCC_RPS435.DOC


                                                                                 FCC ID: LH8RP-S435
                                                                      Test Report #EMCC-950295AOB
                                                                                         Page 4 of 12
                                                                            Issue Date: 2000-NOV-21
    TEST OF CARDIN ELETTRONICA SPA S435 MODEL RPS435000.0US TO 47 CFR PART 15B - UNINTENTIONAL RADIATORS



2 PRODUCT DESCRIPTION

2.1 Equipment Under Test (EUT)

Device:                   Remote Control (RF) Superheterodyne Receiver for automatic opening
                          systems
Model:                    RPS435000.0US
Serial Number:            None
Power:                    120 VAC
Receive Frequency:        433.92 MHz, one RF channel
Antenna:                  external
Interface ports:          relay output ports for 120VAC switching purposes
FCC ID:                   LH8RP-S435


2.2 Configuration and Peripherals of EUT
The EUT was tested as stand-alone device.
The antenna (16 cm rod antenna) provided by the manufacturer was installed and used during tests.
Cables were attached to the relay output ports.


2.3 Mode of Operation During Testing
The receiver were tested in a typical fashion. During testing the receiver operated with and without its
appropriate receive signal.


2.4 Modifications Required for Compliance
None.




FCC_RPS435.DOC


                                                                                FCC ID: LH8RP-S435
                                                                       Test Report #EMCC-950295AOB
                                                                                          Page 5 of 12
                                                                             Issue Date: 2000-NOV-21
    TEST OF CARDIN ELETTRONICA SPA S435 MODEL RPS435000.0US TO 47 CFR PART 15B - UNINTENTIONAL RADIATORS



3 TEST RESULTS SUMMARY

Summary of Test Results
Receiver, model RPS435000.0US

Requirement                               CFR Section              Report Section      Test Result

Conducted Emissions                       15.107                   4                   Pass

Radiated Spurious Emissions               15.109, 15.205(b)        5                   Pass

The client has made the determination that EUT Condition, Characterization, and Mode of Operation are
representative of production units, and meet the requirements of the specifications referenced herein.

Consistent with Industry practice, measurement and test equipment not directly involved in obtaining
measurement results but having an impact on measurements (such as cable loss, antenna factors, etc.)
are factored into the "Correction Factor" documented in certain test results. Instrumentation employed
for testing meets tolerances consistent with known Industry Standards and Regulations.

The measurements contained in this report were made in accordance with the procedure ANSI C63.4 -
1992 and all applicable Public Notices received prior to the date of testing. All emissions from the device
were found to be within the limits outlined in this report.
The test results in this report apply only to the particular Equipment Under Test (EUT) as declared in this
report.

Test Personnel: Reinhard Sauerschell
Issuance Date: 2000-11-21




FCC_RPS435.DOC


                                                                                  FCC ID: LH8RP-S435
                                                                      Test Report #EMCC-950295AOB
                                                                                         Page 6 of 12
                                                                            Issue Date: 2000-NOV-21
    TEST OF CARDIN ELETTRONICA SPA S435 MODEL RPS435000.0US TO 47 CFR PART 15B - UNINTENTIONAL RADIATORS



4 CONDUCTED EMISSIONS TESTS
Test Requirement: FCC CFR47, Part 15B
Test Procedure: ANSI C63.4:1992

4.1 Regulation
Section 15.107 (a) Except for Class A digital devices, for equipment that is designed to be connected to
the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power
line on any frequency or frequencies within the band 450 kHz to 30 MHz shall not exceed 250
microvolts. Compliance with this provision shall be based on the measurement of the radio frequency
voltage between each power line and ground at the power terminals.

Section 15.107 (f) Measurements to demonstrate compliance with the conducted limits are not required
for devices which only employ battery power for operation and which do not operate from the AC power
lines or contain provisions for operation while connected to the AC power lines. Devices that include, or
make provision for, the use of battery chargers which permit operating while charging, AC adaptors or
battery eliminators or that connect to the AC power lines indirectly, obtaining their power through another
device which is connected to the AC power lines, shall be tested to demonstrate compliance with the
conducted limits.


4.2 Test Equipment

Type                 Manufacturer/        Serial No.           Last Calibration       Next Calibration
                     Model No.
Receiver             Rohde & Schwarz      825132/015           March 2000             March 2001
                     ESS
(30 MHz - 1 GHz)
V-LISN 50        Schwarzbeck              253                  May 2000               May 2002
ohms//(50 µH +   NNLA8119(mod)
5 ohms)          (NSLK8127)


4.3 Test Procedures
For tabletop equipment, the EUT is placed on a 1 meter by 1.5 meters wide and 0.8 meter high
nonconductive table that is placed above the groundplane. Floor standing equipment is placed directly
on the groundplane. Any supplemental grounding mechanisms are connected, if appropriate. The EUT is
connected to its associated peripherals, with any excess I/O cabling bundled to approximately 1 meter.
The EUT is connected to a dedicated LISN and all peripherals are connected to a second separate LISN
circuit. The LISNs are bonded to the groundplane.
Conducted measurements are made on each current carrying conductor with respect to ground.

The EUT was tested as a tabletop equipment. During testing the receiver operated with and without its
appropriate receive signal.
The initial step in collecting conducted data is a peak scan of the measurement range with an EMI test
receiver. The significant peaks are then measured with quasi-peak detector.
Worst case conducted emissions are listed under chapter: test results.




FCC_RPS435.DOC


                                                                                    FCC ID: LH8RP-S435
                                                                            Test Report #EMCC-950295AOB
                                                                                               Page 7 of 12
                                                                                  Issue Date: 2000-NOV-21
     TEST OF CARDIN ELETTRONICA SPA S435 MODEL RPS435000.0US TO 47 CFR PART 15B - UNINTENTIONAL RADIATORS


Conducted Emissions Test Characteristics
Frequency range                                           0.45 MHz - 30.0 MHz
Test instrumentation resolution bandwidth                 9 kHz
Lines Tested                                              Line 1 (L) / Line 2 (N)




4.4 Test Results
Device:                      Remote Control (RF) Superheterodyne Receiver for automatic opening
                             systems
Model:                       RPS435000.0US

                                PRODUCT EMISSIONS QUASI PEAK DATA
No     Tested    Emission       Receiver    Result       Spec            Margin      Remarks
       Line      Frequency      Mode and                 Limit
                                Bandwidth

                 [MHz]          [kHz]       [dBµV]       [dBµV]          [dB]
1      L         10.055         9 / QP      22.3         48.0            25.7




                   all other emissions more than 30 dB below the limit




Same results with and without appropriate receive signal.


Judgment: The EUT meets the requirements of this section.

Test Personnel: Reinhard Sauerschell


Test Date: 2000-10-18




FCC_RPS435.DOC


                                                                                 FCC ID: LH8RP-S435
                                                                         Test Report #EMCC-950295AOB
                                                                                            Page 8 of 12
                                                                               Issue Date: 2000-NOV-21
    TEST OF CARDIN ELETTRONICA SPA S435 MODEL RPS435000.0US TO 47 CFR PART 15B - UNINTENTIONAL RADIATORS



5 RADIATED EMISSIONS TEST
Test Requirement: FCC CFR47, Part 15B
Test Procedure: ANSI C63.4:1992

5.1 Regulation
Section 15.109 Radiated emission limits. (a) Except for Class A digital devices, the field strength of
radiated emissions from unintentional radiators at a distance of 3 meters shall not exceed the following
values:

Frequency of Emission                               Field Strength
(MHz)                                               (microvolts/meter)
30 - 88                                             100
88 - 216                                            150
216 - 960                                           200
Above 960                                           500

(c) In the emission tables above, the tighter limits apply at the band edges. Sections 15.33 and 15.35
which specify the frequency range over which the radiated emissions are to be measured and the
detector functions and other measurement standards apply.
(f) For a receiver which employs terminals for the connection of an external receiving antenna, the
receiver shall be tested to demonstrate compliance with the provisions of this Section with an antenna
connected to the antenna terminals unless the antenna conducted power is measured as specified in
Section 15.111(a). If a permanently attached receiving antenna is used, the receiver shall be tested to
demonstrate compliance with the provisions of this Section.
Section 15.33 Frequency range of radiated measurements:
(b) For unintentional radiators: (1) Except as otherwise indicated in paragraphs (b)(2) or (b)(3), for an
unintentional radiator, including a digital device, the spectrum shall be investigated from the lowest radio
frequency signal generated or used in the device, without going below the lowest frequency for which a
radiated emission limit is specified, up to the frequency shown in the following table:

Highest frequency generated or used in the          Upper frequency of measurement
device or on which the range device operates        (MHz)
or tunes (MHz)
Below 1.705                                         30
1.705 - 108                                         1000
108 - 500                                           2000
500 - 1000                                          5000
Above 1000                                          5th harmonic of the highest frequency or 40 GHz,
                                                    whichever is lower




FCC_RPS435.DOC


                                                                                  FCC ID: LH8RP-S435
                                                                      Test Report #EMCC-950295AOB
                                                                                         Page 9 of 12
                                                                            Issue Date: 2000-NOV-21
    TEST OF CARDIN ELETTRONICA SPA S435 MODEL RPS435000.0US TO 47 CFR PART 15B - UNINTENTIONAL RADIATORS


(3) Except for a CB receiver, a receiver employing superheterodyne techniques shall be investigated
from 30 MHz up to at least the second harmonic of the highest local oscillator frequency generated in the
device. If such receiver is controlled by a digital device, the frequency range shall be investigated up to
the higher of the second harmonic of the highest local oscillator frequency generated in the device or the
upper frequency of the measurement range specified for the digital device in paragraph (b)(1) of this
Section.

Section 15.35 Measurement detector functions and bandwidths.
(a) On any frequency or frequencies below or equal to 1000 MHz, the limits shown are based on
measuring equipment employing a CISPR quasi-peak detector function and related measurement
bandwidths, unless otherwise specified. (...)
(b) On any frequency of frequencies above 1000 MHz, the radiated limits shown are based upon the use
of measurement instrumentation employing an average detector function. When average radiated
emission measurements are specified in the regulations, including emission measurements below 1000
MHz, there is also a limit on the radio frequency emissions, as measured using instrumentation with a
peak detector function, corresponding to 20 dB above the maximum permitted average limit for the
frequency being investigated unless a different peak emission limit is otherwise specified in the rules,
e.g., see Section 15.255. Unless otherwise specified, measurements above 1000 MHz shall be
performed using a minimum resolution bandwidth of 1 MHz.

5.2 Test Equipment

Type                 Manufacturer/        Serial No.           Last Calibration       Next Calibration
                     Model No.
Receiver             Rohde & Schwarz      825132/015           March 2000             March 2001
                     ESS
(30 MHz - 1 GHz)
Antenna          EMCO 3143                9608-1316            Feb. 2000              Feb. 2001
(30 MHz - 1 GHz)
Receiver         Rohde & Schwarz                               June 2000              Dec. 2001
                 ESAI-D                   833771/008
(1 GHz - 2 GHz)
                 ESMI-RF                  833827/002
                 ESMI-B1                  832504/005
Antenna          Schwarzbeck              137                  Oct. 1999              Oct. 2001
(1 GHz - 2 GHz)  BBHA 9120 D




FCC_RPS435.DOC


                                                                                FCC ID: LH8RP-S435
                                                                      Test Report #EMCC-950295AOB
                                                                                       Page 10 of 12
                                                                            Issue Date: 2000-NOV-21
    TEST OF CARDIN ELETTRONICA SPA S435 MODEL RPS435000.0US TO 47 CFR PART 15B - UNINTENTIONAL RADIATORS


5.3 Test Procedures
For tabletop equipment, the EUT is placed on a 1 meter by 1.5 meters wide and 0.8 meter high
nonconductive table that sits on a flush mounted metal turntable. Floor standing equipment is placed
directly on the flush mounted metal turntable [Remark: Not applicable]. The EUT is connected to its
associated peripherals with any excess I/O cabling bundled to approximately 1 meter [Remark: No
peripherals connected].
Preview tests are performed to determine the "worst case" mode of operation. With the EUT operating
in "worst case" mode, emissions from the unit are maximized by adjusting the polarization and height of
the receive antenna and rotating the EUT on the turntable. Manipulating the system cables also
maximizes EUT emissions.
Radiated Emissions Test Characteristics
Frequency range                                       30 MHz - 2,000 MHz
Test distance                                         3m
Test instrumentation resolution bandwidth             120 kHz (30 MHz - 1,000 MHz)
                                                      1 MHz (1,000 MHz - 2,000 MHz)
Receive antenna scan height                           1m-4m
Receive antenna polarization                          Vertical/Horizontal



5.4 Field Strength Calculation
The field strength is calculated by adding the Antenna Factor and Cable Factor. The basic equation with
a sample calculation is as follows:

FS = RA + AF + CF
where
    FS = Field Strength in dB(µV/m)
    RA = Receiver Amplitude in dB(µV)
    AF = Antenna Factor in dB(1/m)
    CF = Cable Attenuation Factor in dB

Assume a receiver reading of 23.5 dB(µV) is obtained. The Antenna Factor of 7.4 dB(1/m) and a Cable
Factor of 1.1 dB are added, giving a field strength of 32 dB(µV/m). The 32 dB(µV/m) value can be
mathematically converted to its corresponding level in µV/m.

FS = 23.5 dB(µV) + 7.4 dB(1/m) + 1.1 dB = 32 dB(µV/m)

FS = 10(32/20) µV/m = 39.8 µV/m




FCC_RPS435.DOC


                                                                                                 FCC ID: LH8RP-S435
                                                                                     Test Report #EMCC-950295AOB
                                                                                                      Page 11 of 12
                                                                                           Issue Date: 2000-NOV-21
     TEST OF CARDIN ELETTRONICA SPA S435 MODEL RPS435000.0US TO 47 CFR PART 15B - UNINTENTIONAL RADIATORS


5.5 Test Results
Device:                      Remote Control (RF) Superheterodyne Receiver for automatic opening
                             systems
Model:                       RPS435000.0US



                                                PRODUCT EMISSIONS
No   Emission    Receiver    Test       Receiver   Correction   Result =     Spec         Antenna    Polari-   Margin
     Frequency   Mode and    Distance   Reading    Factor       Corrected    Limit        Height     zation
                 Bandwidth                                      Reading
                                        RA         AF+CF        FS                                   ANT
     [MHz]       [kHz]       [m]        [dB(µV)]   [dB(1/m)]    [dB(µV/m)]   [dB(µV/m)]   [m]                  [dB]
1    433.39      QP 120      3          13.5       20.5         34           46           1.00       v         12
2    1300        AV, 1000    3          4.3        26.8         31.1         54           1.00       h         22.9
                 Pk, 1000    3          15.6*      26.8         42.4*        54 + 20=     1.00       h         31.6
                                                                             74




Same results with and without appropriate receive signal.
Remark: * noise floor


Judgment: The EUT meets the requirements of this section.




Test Personnel: Reinhard Sauerschell


Test Date: 2000-10-24




FCC_RPS435.DOC


                                                                                FCC ID: LH8RP-S435
                                                                      Test Report #EMCC-950295AOB
                                                                                       Page 12 of 12
                                                                            Issue Date: 2000-NOV-21
    TEST OF CARDIN ELETTRONICA SPA S435 MODEL RPS435000.0US TO 47 CFR PART 15B - UNINTENTIONAL RADIATORS



6 MISCELLANEOUS COMMENTS AND NOTES
None.




7 LIST OF ANNEXES


Following annexes are separated parts to this test report.


Description                                                                       Pages
Annex 1: Photographs of test setups                                               3
Annex 2: Photographs of equipment under test (EUT)                                7




FCC_RPS435.DOC



Document Created: 2000-11-24 16:47:31
Document Modified: 2000-11-24 16:47:31

© 2024 FCC.report