Voltage Variation Test

FCC ID: LGYBT261159P

Test Report

Download: PDF
FCCID_755738

             HOW THE EUT MEETS THE REQUIREMENTS OF 15.31 (e)
FOR THE O’NEIL PRODUCT DEVELOPMENT BLUETOOTH MODULE MODEL: BT261159P

The fundamental was maximized on the Lab B test site using a normal test setup with the AC
Adapter for each printer connected directly to the AC public mains (115 Vac).

Next, the AC Adapter for each printer was then connected to the Staco Energy Products Variable
Auto Transformer Model: 3PN1010. The Variable Auto Transformer allows the Vac input to be
varied.

The AC Adapter for each printer was then connected to the Staco Energy Products Variable Auto
Transformer Model: 3PN1010. The AC input was then dropped to 85% (97.75 Vac) and raised to
115% (132.25 Vac). The actual AC input was measured using a calibrated Fluke Multimeter Model:
87, Serial Number: 956410240, Calibration Due Date: Dec. 15, 2006. The fundamental was then
verified again to see that the amplitude did not change.

Test Result: The EUT does NOT change amplitude at the fundamental when the AC input voltage is
varied between 85% and 115% of the input nominal rated supply voltage.



Document Created: 2007-02-01 15:02:28
Document Modified: 2007-02-01 15:02:28

© 2024 FCC.report