MPE Revised

FCC ID: LDKXSCLCR14

RF Exposure Info

Download: PDF
FCCID_558359

                                                                   MPE Calculations (Mobile)

The device is not a portable device (i.e. intended to be worn on the body or be hand-held), so it is classified as being either a mobile device or a
fixed mounted device. The userís manual specifies a minimum separation distance of at least 20cm, consistent with this classification.

FCC part 1.1310, Table 1 limits the power density for uncontrolled exposure. The power density, Pd (mW/cm2 ) calculated from the maximum
EIRP, Pt (mW) and the distance, d (m), between the transmitting antenna and the closest person, can be calculated using:

                             Formula is:
                                             Pd = Pt / (4*pi*d2)

                                           MPE Limit                    Pd at 20cm     Distance where Pd
                    Frequency (MHz)                    Eirp (mW)
                                           (mW/cm 2)                    (mW/cm 2)         = Limit (cm)
                       2400 - 4990            1         1406.52            0.28               10.6


                                  Output Power    Antenna gain            EIRP                                                        Total EIRP
      Band           Mode                                                             Channels Available      Channels Used
                                 Peak     Average    (Max)            dBm      W                                                     W         dBm
 2400 - 2483.5       CCK           -       20.0       7.5             27.5 0.562               11                    1             0.562       27.50
 2400 - 2483.5       CCK           -       20.0       7.5             27.5 0.562               11                    1             0.562       27.50
  4940 - 4990       OFDM           -       17.0       7.5             24.5 0.282               10                    1             0.282       24.50
                                                                                                    Totals:          3             1.407       31.48

MPE exposure is based on two 2.4GHz pre-approved modules with one 4.9GHz transmitter. Device can be programmed to transmitt
simultaneously.



                             Formula is:
                                             Pd = Pt / (4*pi*d2)

                                           MPE Limit                    Pd at 20cm     Distance where Pd
                    Frequency (MHz)                    Eirp (mW)
                                           (mW/cm 2)                    (mW/cm 2)         = Limit (cm)
                       2400 - 4990            1         1687.02            0.34               11.6


                                  Output Power    Antenna gain            EIRP                                                        Total EIRP
      Band           Mode                                                             Channels Available      Channels Used
                                 Peak     Average    (Max)            dBm      W                                                     W         dBm
 2400 - 2483.5       CCK           -       20.0       7.5             27.5 0.562               11                    1             0.562       27.50
 2400 - 2483.5       CCK           -       20.0       7.5             27.5 0.562               11                    1             0.562       27.50
 2400 - 2483.5       CCK           -       20.0       7.5             27.5 0.562               11                    1             0.562       27.50
                                                                                                    Totals:          3             1.687       32.27

MPE exposure is based on three 2.4GHz transmitter. Device can be programmed to transmitt simultaneously.


                             Formula is:
                                                              2
                                             Pd = Pt / (4*pi*d )

                                           MPE Limit                    Pd at 20cm     Distance where Pd
                    Frequency (MHz)                    Eirp (mW)
                                           (mW/cm 2)                    (mW/cm 2)         = Limit (cm)
                       2400 - 4990            1         1126.02            0.22               9.5


                                  Output Power    Antenna gain            EIRP                                                        Total EIRP
      Band           Mode                                                             Channels Available      Channels Used
                                 Peak     Average    (Max)            dBm      W                                                     W         dBm
 2400 - 2483.5       CCK           -       20.0       7.5             27.5 0.562               11                    1             0.562       27.50
  4940 - 4990       OFDM           -       17.0       7.5             24.5 0.282               10                    1             0.282       24.50
  4940 - 4990       OFDM           -       17.0       7.5             24.5 0.282               10                    1             0.282       24.50
                                                                                                    Totals:          3             1.126       30.52

MPE exposure is based on two 4.9GHz transmitter and one 2.4GHz radio. Device can be programmed to transmitt simultaneously.


                                                              MPE Calculations (Fixed Location)

The device is not a portable device (i.e. intended to be worn on the body or be hand-held), so it is classified as a fixed mounted device. The userís
manual specifies a minimum separation distance of at least 35cm, consistent with this classification.

FCC part 1.1310, Table 1 limits the power density for uncontrolled exposure. The power density, Pd (mW/cm2 ) calculated from the maximum EIRP,
Pt (mW) and the distance, d (m), between the transmitting antenna and the closest person, can be calculated using:

                              Formula is:
                                               Pd = Pt / (4*pi*d2)

                                            MPE Limit                   Pd at 20cm    Distance where Pd
                     Frequency (MHz)                     Eirp (mW)
                                            (mW/cm2)                    (mW/cm2)          = Limit (cm)
                       2400 - 4990             1         11333.35          2.25               30.0


                                  Output Power          Antenna gain      EIRP                                                         Total EIRP
      Band           Mode                                                         Channels Available         Channels Used
                                 Peak     Average          (Max)       dBm     W                                                     W          dBm
 2400 - 2483.5       CCK           -       13.0             21.0       34.0 2.512        11                         1              2.512        34.00
 2400 - 2483.5       CCK           -       13.0             21.0       34.0 2.512        11                         1              2.512        34.00
  4940 - 4990       OFDM           -       17.0             21.0       38.0 6.310        10                         1              6.310        38.00
                                                                                             Totals:                3              11.333       40.54


MPE exposure is based on two 2.4GHz pre-approved modules with one 4.9GHz transmitter. Device can be programmed to transmitt simultaneously.



                              Formula is:
                                                                2
                                               Pd = Pt / (4*pi*d )

                                            MPE Limit                   Pd at 20cm    Distance where Pd
                     Frequency (MHz)                     Eirp (mW)
                                            (mW/cm2)                    (mW/cm2)          = Limit (cm)
                       2400 - 4990             1          7535.66          1.50               24.5


                                  Output Power          Antenna gain      EIRP                                                        Total EIRP
      Band           Mode                                                         Channels Available         Channels Used
                                 Peak     Average          (Max)       dBm     W                                                     W         dBm
 2400 - 2483.5       CCK           -       13.0             21.0       34.0 2.512        11                         1              2.512       34.00
 2400 - 2483.5       CCK           -       13.0             21.0       34.0 2.512        11                         1              2.512       34.00
 2400 - 2483.5       CCK           -       13.0             21.0       34.0 2.512        11                         1              2.512       34.00
                                                                                             Totals:                3              7.536       38.77

MPE exposure is based on three 2.4GHz transmitter. Device can be programmed to transmitt simultaneously.


                              Formula is:
                                               Pd = Pt / (4*pi*d2)

                                            MPE Limit                   Pd at 20cm    Distance where Pd
                     Frequency (MHz)                     Eirp (mW)
                                            (mW/cm2)                    (mW/cm2)          = Limit (cm)
                       2400 - 4990             1         15131.03          3.01               34.7


                                  Output Power          Antenna gain      EIRP                                                         Total EIRP
      Band           Mode                                                         Channels Available         Channels Used
                                 Peak     Average          (Max)       dBm     W                                                     W          dBm
 2400 - 2483.5       CCK           -       13.0             21.0       34.0 2.512        11                         1              2.512        34.00
  4940 - 4990       OFDM           -       17.0             21.0       38.0 6.310        10                         1              6.310        38.00
  4940 - 4990       OFDM           -       17.0             21.0       38.0 6.310        10                         1              6.310        38.00
                                                                                             Totals:                3              15.131       41.80

MPE exposure is based on two 4.9GHz transmitter and one 2.4GHz radio. Device can be programmed to transmitt simultaneously.



Document Created: 2005-06-09 13:56:54
Document Modified: 2005-06-09 13:56:54

© 2024 FCC.report