                              Cisco Systems Inc
                              170 West Tasman
                              San Jose, CA 95134
                                     USA




This report shall not be reproduced except in full without written permission by Cisco Systems Inc
1.


Cisco Systems Inc                                                                EDCS # EDCS-838699

Model Number: CP-9951 series




08/05/2009

1.0: Attestation Statement of Compliance

 The Cisco Systems Inc CP-9951 Series IP Phone with Bluetooth Ver 2.1 has been
 evaluated for Maximum Permissible Exposure in compliance with 47 Code of Federal
 Regulations 2.1093. The evaluation was in accordance with methodology as referenced
 in FCC Bulletin OET 65C (rev 01-01)


 This report serves as the technical analysis of Cisco of the radios in the CP-9951 series.
 The technical information referenced for this study was derived from the FCC / Canada
 test report on the product.

 For purposes of this study, the evaluation was only done with the worse case antennae
 for each programmable power level.

 The limits used for this evaluation are in line with the recommendations of the World
 Health Organizations (WHO) International Committee on Non Ionizing Radiation
 Protection (ICNIRP) as well as the American National Standards Institute (ANSI)
 C95.1.

 This analysis also complies with the requirements stated in Industry Canada RSS-102 as
 well as the applicable Australian and New Zealand regulations.



_______________________________________________
 Phillip Carranco
Compliance Engineer
Cisco Systems Inc
170 W Tasman Dr
San Jose, CA 93727
Phone: 408.525.2635
Email: pcarranc@cisco.com




This report shall not be reproduced except in full without written permission by Cisco Systems Inc
2.


Cisco Systems Inc                                                                  EDCS # EDCS-838699

Model Number: CP-9951 series



2.0 EUT Description.
This is a Cisco IP Phone with 802.15 Bluetooth Ver. 2.1 Radio.


3.0 Methodology
All calculations were made in accordance with ANSI C95.1, and FCC OET 65C.


4.0 Technical Requirements

        4.1 Single Band Operation – Limits

     As referenced by OET 65C / RSS-102

(B) Limits for General Population/Uncontrolled Exposure


   Frequency            Electric Field        Magnetic Field        Power Density         Averaging Time
     Range              Strength (E)          Strength (H)              (S)                |E|2, |H|2 or S
     (MHz)                 (V/m)                  (A/m)               (mW/cm2)               (minutes)

    0.3-1.34                 614                   1.63                 (100)*                   30
    1.34-30                 824/f                 2.19/f               (180/f2)*                 30
    30-300                  27.5                  0.073                   0.2                   30
    300-1500                  --                    --                  f/1500                   30
  1500-100,000                --                    --                    1.0                    30

                     f = frequency in MHz      *Plane-wave equivalent power density

NOTE 1: See Section 1 for discussion of exposure categories.

NOTE 2: The averaging time for General Population/Uncontrolled exposure to fixed
        transmitters is not applicable for mobile and portable transmitters. See 47 CFR
        §§2.1091 and 2.1093 on source-based time-averaging requirements for mobile and
        portable transmitters.




This report shall not be reproduced except in full without written permission by Cisco Systems Inc
3.


Cisco Systems Inc                                                                    EDCS # EDCS-838699

Model Number: CP-9951 series


 Excerpt from Australian Radiation Protection Standard

  REFERENCE LEVELS FOR TIME AVERAGED EXPOSURE TO
  RMS ELECTRIC AND MAGNETIC FIELDS (UNPERTURBED
                      FIELDS)
Exposure         Frequency                 E-field          H-field          Equivalent plane
category         range                    strength         strength          wave power flux
                                         (V/m rms)        (A/m rms)            density Seq
                                                                                 (W/m2)


Occupational     100 kHz – 1 MHz        614               1.63 / f          —
                 1 MHz – 10 MHz         614 / f           1.63 / f          1000 / f 2 (see note 5)
                 10 MHz – 400 MHz       61.4             0.163                    10      (see note 5)
                 400 MHz – 2 GHz          3.07 × f 0.5    0.00814 × f 0.5   f/ 40
                 2 GHz – 300 GHz        137              0.364                  50


General public   100 kHz – 150 kHz      86.8             4.86                     —
                 150 kHz – 1 MHz        86.8              0.729 / f                  —
                    1 MHz – 10 MHz        86.8 / f 0.5    0.729 / f                  —
                 10 MHz – 400 MHz       27.4              0.0729                     2   (see note 6)
                                                                            f/
                 400 MHz – 2 GHz          1.37 × f 0.5    0.00364 × f 0.5
                                                                            200
                 2 GHz – 300 GHz        61.4             0.163                    10




5.0 Calculations
Given

E=         (30*P*G)/d

Where E = field strength in Volts per meter
      P = Power in Watts
      G = Antenna Gain in dBi
      D = distance in cm




This report shall not be reproduced except in full without written permission by Cisco Systems Inc
4.


Cisco Systems Inc                                                                EDCS # EDCS-838699

Model Number: CP-9951 series

Changing units of power to mW and meters to cm

     P = mW = P (W) /1000 and
     d(cm)= 100 *d(m)




Yields


E = 100*        (30*(P / 1000*G)/d)
E=    17.32      (P*G)/d

Using the logarithmic formula for power and gain

P(mW) = 10^ ((P +G)/20)/d
G (numeric) = 10^(G (dBi) /10)




6.0 Results

                 Table 2



   Frequency               TX Power            Antenna Gain              Distance            mW/cm^2      Limit

     2402 MHz              4.63 dBm                0.44 dBi                20cm                 0.0006   1mW/m^2