MPE

FCC ID: LDKDPC3939DECT

RF Exposure Info

Download: PDF
FCCID_1975856

FCC ID: LDKDPC3939DECT                                                                          Sheet 29 of 89 Sheets
                                                                                       ETC Report No.: 13-03-MAS-074


6.11 Safety exposure levels

6.11.1 Standard Applicable: FCC 15.319(i)

UPCS devices are subject to the radio frequency radiation exposure requirements specified in FCC
parts 1.1307 (b), 2.1091 and 2.1093, as appropriate. All equipment shall be considered to operate in
a “general population / uncontrolled environment. For portable devices tests according to IEEE 1528
are requested, if applicable.

6.11.2 Measurement procedure

Consideration of radio frequency radiation exposure for EUT is done as


                          SAR test according IEEE1528 (for PP)

                       MPE calculation as below (for FP, Repeater)


SAR test results: not applicable



MPE calculation:


The EUT is considered as a mobile device according to OET Bulletin 65, Edition -97-01. Therefore
distance to human body of min. 20 cm is determined.


The limit of Power density for General Population / Umcontrolled Exposure is 1.0 mW/cm².
Formula:


                 S = EIRP / 4πR²


Calculation:


              EIRP                Radiated Power (dBm)                                   23.39
              EIRP                 Radiated Power (mW)                                   218.3
               R                        Distance (cm)                                      20
               S                 Power Density (mW/cm²)                                  0.0434




                                         Electronics Testing Center, Taiwan
               No.8, Lane 29, Wenming RD., LeShan Tsuen, GuiShan Shiang, Taoyuan County 33383, Taiwan, R.O.C.
Rev. No 1.0


FCC ID: LDKDPC3939DECT                                                                         Sheet 30 of 89 Sheets
                                                                                      ETC Report No.: 13-03-MAS-074




 Simultaneous Evaluation:

   WLAN 2.4GHz, 5GHz and DECT radio can transmit simultaneously.
   The formula of calculated MPE is:
       CPD1/LPD1+CPD2/LPD2+…etc. < 1
         CPD=Calculated Power Density
         LPD=Limit of Power Density



              Radio Technology                                    Worse CPD (mW/cm2)
                 WiFi 2.4 GHz                                               0.4246
                  WiFi 5 GHz                                                0.2071
                      DECT                                                  0.0434



   The MPE evaluation is 0.4246/1+0.2071/1+0.0434/1=0.6751<1, which confirm the
   device comply the MPE limit.




6.11.3 Results:Complies




                                        Electronics Testing Center, Taiwan
              No.8, Lane 29, Wenming RD., LeShan Tsuen, GuiShan Shiang, Taoyuan County 33383, Taiwan, R.O.C.
Rev. No 1.0



Document Created: 2013-05-24 16:04:18
Document Modified: 2013-05-24 16:04:18

© 2024 FCC.report