Cisco RLK190621001-00E FCC Part 15.247 (Radiated)

FCC ID: LDKAX5122118

Test Report

Download: PDF
FCCID_4444280

                        FCC Part 15.247; LP0002-2018

 RSS-247 Issue 2, Feb 2017; RSS-Gen Issue 5, Feb 2019

                                   TEST REPORT
                                                  For

                             Cisco Systems, Inc.
                         125 West Tasman Dr., San Jose, CA 95134, USA


                                 FCC ID: LDKAX5122118
                                  IC : 2461N-AX5122118


 Report Type :                    Original Report

 Product Type :                   Cisco Catalyst 9130AX Series Wi-Fi 6 Access Points

                                  For FCC: C9130AXI-B
 Product Name :                   For Canada: C9130AXI-A
                                  For Taiwan: C9130AXI-T

 Report Number :                  RLK190621001-00E

 Report Date :                    2019/08/30

 Reviewed By :                    Zeus Chen

 Prepared By:
 Bay Area Compliance Laboratories Corp.(Linkou Laboratory)
 No.6, Wende 2Rd., Guishan Dist., Taoyuan City 33382, Taiwan (R.O.C.)
 Tel. (886-3)396-1072
 Fax.(886-3)396-1027
 www.bacl.com.tw

Note: This test report is prepared for the customer shown above and for the device described herein. It
may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories
Corp. (Taiwan).


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                Report No.: RLK190621001-00E




                                           Revision History
    Revision                  Report Number                 Issue Date            Description

       1.0                RLK190621001-00E                  2019/08/30         Original Report




                                                                                       Page 2 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                                                          Report No.: RLK190621001-00E


                                                                   TABLE OF CONTENTS
1     GENERAL INFORMATION ............................................................................................................................... 4
    1.1  PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ................................................................... 4
    1.2  OPERATION CONDITION OF EUT .................................................................................................................. 4
    1.3  OBJECTIVE AND TEST METHODOLOGY ......................................................................................................... 5
    1.4  MEASUREMENT UNCERTAINTY ...................................................................................................................... 5
    1.5  TEST FACILITY ............................................................................................................................................... 5
2     SYSTEM TEST CONFIGURATION .................................................................................................................. 6
    2.1  TEST CHANNELS AND DESCRIPTION OF W ORST TEST CONFIGURATION ..................................................... 6
    2.2  SUPPORT EQUIPMENT LIST AND EXTERNAL CABLE LIST ............................................................................. 7
    2.3  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................. 8
    2.4  DUTY CYCLE .................................................................................................................................................. 9
3       SUMMARY OF TEST RESULTS .................................................................................................................... 10
4     FCC §15.203, RSS-GEN AND LP0002 SEC 2.2- ANTENNA REQUIREMENTS................................... 11
    4.1   APPLICABLE STANDARD .............................................................................................................................. 11
    4.2   ANTENNA LIST AND DETAILS ....................................................................................................................... 11
5   FCC §15.207, §15.407 (B), RSS-GEN SEC 8.8 AND LP0002 SEC 2.3 - AC LINE CONDUCTED
EMISSIONS ................................................................................................................................................................. 12
  5.1   APPLICABLE STANDARD .............................................................................................................................. 12
  5.2   EUT SETUP AND TEST PROCEDURE........................................................................................................... 12
  5.3   TEST EQUIPMENT LIST AND DETAILS .......................................................................................................... 13
  5.4   TEST ENVIRONMENTAL CONDITIONS .......................................................................................................... 13
  5.5   AC LINE CONDUCTED EMISSION TEST PLOT AND DATA ............................................................................ 14
6   FCC §15.209, §15.205, §15.247(D), §2.1053, RSS-GEN SEC 8.9, 8.10, RSS-247 SEC 5.5 AND LP0002
SEC 3.10, 2.7 AND 2.8 – SPURIOUS UNWANTED EMISSIONS ..................................................................... 18
  6.1   APPLICABLE STANDARD .............................................................................................................................. 18
  6.2   EUT SETUP AND TEST PROCEDURE........................................................................................................... 20
  6.3   TEST EQUIPMENT LIST AND DETAILS .......................................................................................................... 22
  6.4   TEST ENVIRONMENTAL CONDITIONS .......................................................................................................... 22
  6.5   RADIATED EMISSION TEST PLOT AND DATA ............................................................................................... 23




                                                                                                                                                            Page 3 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                    Report No.: RLK190621001-00E


1 General Information

1.1    Product Description for Equipment under Test (EUT)
                                                   Cisco Systems, Inc.
Applicant                                          125 West Tasman Dr., San Jose, CA 95134, USA

                                                   Cisco Systems, Inc.
Manufacturer                                       125 West Tasman Dr., San Jose, CA 95134, USA

Brand(Trade) Name                                  Cisco
Product (Equipment)                                Cisco Catalyst 9130AX Series Wi-Fi 6 Access Points

                                                   For FCC: C9130AXI-B
Model Name                                         For Canada: C9130AXI-A
                                                   For Taiwan: C9130AXI-T

                                                   802.11b/g/n HT20/ax HE20: 2412-2462 MHz
Frequency Range                                    BLE: 2402-2480 MHz

Received Date                                      Jun. 21, 2019.
Date of Test                                       Jun. 21, 2019 ~ Aug. 26, 2019

                                                   IEEE 802.11b : DSSS
Modulation Type                                    IEEE 802.11g/n HT20/ax HE20: OFDM
                                                   BLE mode: GFSK

                                                   FCC Part 15.407 UNII with FCC ID: LDKAX5122118
Related Submittal(s)/Grant(s)                      ISEDC RSS-247: UNII IC: 2461N-AX5122118

*All measurement and test data in this report was gathered from production sample serial number: KWC2317002 (Assigned by BACL-

LK)



1.2    Operation Condition of EUT


                                                     DC Type
                                                       PoE: 30W
Power Operation                                          Brand Name: Cisco
                                                         Model: SB-PWR-INJ2
(Voltage Range)
                                                         I/P: 100-240Vac,50/60Hz, 0.67A
                                                         O/P: 55Vdc,0.6A
                                                         By Power Core




                                                                                                               Page 4 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                             Report No.: RLK190621001-00E


1.3   Objective and Test Methodology

The Objective of this Test Report was to document the compliance of the Cisco System, Inc. Appliance
(Model: For FCC: C9130AXI-B; For Canada: C9130AXI-A, For Taiwan: C9130AXI-T) to the requirements of
the following Standards:


-Part 2, Subpart J, Part 15 Subparts A and Part 15 Subparts E of the Federal Communication Commission’s rules.
-ANSI C63.10-2013 “American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.
-KDB 662911 D01 Multiple Transmitter Output v02r01.
-KDB 789033 D02 General U-NII Test Procedures New Rules v02r01.

-RSS-247 Issue 2, Feb 2017 — Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence-
Exempt Local Area Network (LE-LAN) Devices.
-RSS-Gen Issue 5, Feb 2019 — General Requirements for Compliance of Radio Apparatus.

-LP0002 — Low-power Radio-frequency Devices Technical Regulations.


1.4   Measurement Uncertainty

                      Parameter                                     Expanded Measurement uncertainty

         RF output power with Power Meter                                           ± 0.55 dB
             Occupied Channel Bandwidth                                             ± 4.45 %
           RF Conducted test with Spectrum                                          ± 1.45 dB
         AC Power Line Conducted Emission                                           ± 2.66 dB
                Radiated Below 1G                                                   ± 3.57 dB
              Radiated Above 1G-18G                                                 ± 4.29 dB
             Radiated Above 18G-40G                                                 ± 4.67 dB


1.5   Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Taiwan) to collect test data is located on
   No.6, Wende 2Rd., Guishan Dist., Taoyuan City 33382, Taiwan (R.O.C.).


The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public Access
Link (PAL) database. The FCC Registration No.: 0027578244. Designation No.: TW3546. The Test Firm
Registration No.: 181430.




                                                                                                       Page 5 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                     Report No.: RLK190621001-00E


2 System Test Configuration

2.1     Test Channels and Description of Worst Test Configuration
The system was configured for testing in testing mode which was provided by manufacturer.

No special accessory, No modification was made to the EUT and No special equipment used during test.



      For Wi-Fi 2.4G mode:


                                     Frequency                                              Frequency
          Channel                                              Channel
                                       (MHz)                                                  (MHz)
             1                          2412                       8                          2447
             2                          2417                       9                          2452
             3                          2422                       10                         2457
             4                          2427                       11                         2462
             5                          2432                       -                            -
             6                          2437                       -                            -
             7                          2442                       -                            -

For 802.11b/g/n HT20/ax HE20 modes: Channel 1, 6 and 11 were tested.



      For BLE mode:


                                     Frequency                                              Frequency
          Channel                                              Channel
                                       (MHz)                                                  (MHz)
             0                          2402                       20                         2442
             1                          2404                       --                           --
             2                          2406                       --                           --
             3                          2408                       37                         2476
             --                           --                       38                         2478
             12                         2426                       39                         2480

For BLE modes: Channel 0, 12 and 39 were tested.

Radiated below 1G were tested worst output power mode.




                                                                                              Page 6 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                Report No.: RLK190621001-00E


2.2   Support Equipment List and External Cable List

No.      Description          Manufacturer             Model Number      BSMI           FCC ID / DoC
 A      Notebook PC*2              DELL                Latitude E5470    R33002             DoC



No.              Cable Description                          Length (m)   From                To
 1                    LAN Cable                         Non- Shielded     EUT                NB
 2                    LAN Cable                         Non- Shielded     EUT               PoE
 3                    LAN Cable                         Non- Shielded     NB                PoE




                                                                                       Page 7 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                    Report No.: RLK190621001-00E


2.3   Block Diagram of Test Setup


                     Conduction                                             Radiation




                                   Modulation Used for Conformance Test
     Configuration                      NTX                  Data Rate                Worst Data Rate
    802.11b mode                         4                   1-11 Mbps                   1 Mbps
    802.11g mode                   4/1(ChillWave)            6-54 Mbps                   6 Mbps
 802.11n HT 20 mode                      4                    MCS 0-7                     MCS 0
 802.11ax HE 20 mode                     4                    MCS 0-7                     MCS 0
      BLE mode                           1                125 kbps-1 Mbps                 1 Mbps


                                          Worst Case of Power Setting
        EUT Exercise Software                                           Command
     Configuration           NTX                     Low CH              Mid CH             High CH
    802.11b mode              4                        17                  17                  17
    802.11g mode        4/1(ChillWave)                 17                  17                  17
 802.11n HT 20 mode           4                        17                  17                  17
 802.11ax HE 20 mode          4                        17                  17                  17
      BLE mode                1                         5                   5                   5




                                                                                           Page 8 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                         Report No.: RLK190621001-00E


2.4    Duty Cycle
According to KDB 558074 D01 15.247 Meas Guidance v05r02:
All measurements are to be performed with the EUT transmitting at 100% duty cycle at its maximum power
control level; however, if 100% duty cycle cannot be achieved, measurements of duty cycle, x, and maximum
power transmission duration, T, are required for each tested mode of operation.

           Configuration                     On Time (ms)   Period (ms)   Duty Cycle (%)       Duty Factor (dB)

           802.11b mode                          0.96          1.17               92.10              0.36
           802.11g mode                          1.43          1.56               82.26              0.85
       802.11n HT 20 mode                        5.43          5.75               96.11              0.17
       802.11ax HE 20 mode                       5.45          5.74               95.73              0.19
             BLE mode                             -             -                 100                  0
      ChillWave mode 802.11g                      -             -                 100                  0


*Note: Duty Factor = 10*log (1/Duty cycle)




                                                                                                Page 9 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                               Report No.: RLK190621001-00E


3 Summary of Test Results


           FCC/ISEDC/NCC Rules                                Description of Test                     Result


          §15.247(i), §1.1317, §2.1091
               ISEDC RSS-102                          Maximum Permissible Exposure (MPE)               Note1
              LP0002 Sec 5.20.2


                FCC §15.203
           ISEDC RSS-Gen Sec 6.8                               Antenna Requirement                  Compliance
       LP0002-2018 Sec 2.2 and 3.10.1.3


                 FCC §15.207
            ISEDC RSS-Gen Sec 8.8                         AC Line Conducted Emissions               Compliance
              LP0002-2018 Sec 2.3

       FCC §15.205, §15.209, §15.247(d)
       ISEDC RSS-Gen Sec 8.9 and 8.10
                                                           Spurious Unwanted Emission               Compliance
           ISEDC RSS-247 Sec 5.5
       LP0002-2018 Sec 3.10, 2.7 and 2.8

               FCC §15.247(a)(2)
            ISEDC RSS-247 Sec 5.2
                                                               Emission Bandwidth                      Note2
            ISEDC RSS-Gen Sec 6.7
              LP0002 Sec 3.10.1.6

               FCC §15.247(b)(3)
            ISED RSS-247 Sec5.4(d)                           Maximum Output Power                      Note2
              LP0002 Sec 3.10.1.2


            FCC §2.1051, §15.247(d)
            ISEDC RSS-247 Sec 5.5                                   Band Edge                          Note2
              LP0002 Sec 3.10.1.5


                FCC §15.247(e)
           ISEDC RSS-247 Sec 5.2(b)                           Power Spectral Density                   Note2
            LP0002 Sec 3.10.1.6(2)(b)

Note1: RF Exposure evaluation was recorded in a separate report in this filing.
Note2: Compliance test data was recorded in a separate reports, please refer to Test Report: EDCS-17873174, EDCS-
17873187, EDCS-17873175.




                                                                                                      Page 10 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                          Report No.: RLK190621001-00E


4 FCC §15.203, RSS-Gen and LP0002 Sec 2.2- Antenna Requirements

4.1   Applicable Standard

According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or
of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with
the provisions of this section. The manufacturer may design the unit so that a broken antenna can be replaced
by the user, but the user of a standard antenna jack or electrical connector is prohibited.

And according to FCC 47 CFR section 15.247 (b), if the transmitting antennas of directional gain greater than
6dBi are used, the power shall be reduced by the amount in dB that the directional gain of the antenna does not
exceed 6dBi



4.2   Antenna List and Details

            Radio                 Item             Manufacturer        Antenna Type           Antenna Gain
              BLE                 BLE                   Cisco          Internal antenna           4 dBi
                           Wi-Fi 2.4G Chain 0           Cisco          Internal antenna           4 dBi
                           Wi-Fi 2.4G Chain 1           Cisco          Internal antenna           4 dBi
                           Wi-Fi 2.4G Chain 2           Cisco          Internal antenna           4 dBi
                           Wi-Fi 2.4G Chain 3           Cisco          Internal antenna           4 dBi
            XOR
                            Wi-Fi 5G Chain 0            Cisco          Internal antenna           6 dBi
                            Wi-Fi 5G Chain 1            Cisco          Internal antenna           6 dBi
                            Wi-Fi 5G Chain 2            Cisco          Internal antenna           6 dBi
                            Wi-Fi 5G Chain 3            Cisco          Internal antenna           6 dBi
                            Wi-Fi 5G Chain 4            Cisco          Internal antenna           6 dBi
                            Wi-Fi 5G Chain 5            Cisco          Internal antenna           6 dBi
           Regular
                            Wi-Fi 5G Chain 6            Cisco          Internal antenna           6 dBi
                            Wi-Fi 5G Chain 7            Cisco          Internal antenna           6 dBi
                               Wi-Fi 2.4G               Cisco          Internal antenna           5 dBi
          Chillwave
                                Wi-Fi 5G                Cisco          Internal antenna           6 dBi


The EUT has an internal antenna arrangement, which was permanently attached, fulfill the requirement of this
section.




                                                                                                   Page 11 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                Report No.: RLK190621001-00E


5 FCC §15.207, §15.407 (b), RSS-Gen Sec 8.8 and LP0002 Sec 2.3 - AC
  Line Conducted Emissions

5.1    Applicable Standard

According to FCC §15.407(b) (6) , RSS-Gen Sec 8.8 and LP0002 Sec 2.3.

Any U-NII devices using an AC power line are required to comply also with the conducted limits set forth in
§15.207.

For an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio
frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the
band 150 kHz to 30 MHz shall not exceed the limits in the following table, as measured using a 50 µH/50 ohms
line impedance stabilization network (LISN). Compliance with the provisions of this paragraph shall be based
on the measurement of the radio frequency voltage between each power line and ground at the power terminal.
The lower limit applies at the boundary between the frequencies ranges.
                                                                     Conducted Limit (dBuV)
               Channel
                                                       Quasi-Peak                                  Average
               0.15-0.5                                66 to 56 Note 1                           56 to 46 Note 2
                 0.5-5                                       56                                        46
                 5-30                                        60                                        50

Note 1: Decreases with the logarithm of the frequency. Note 2: A linear average detector is required




5.2    EUT Setup and Test Procedure




                                                                                                            Page 12 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                               Report No.: RLK190621001-00E

The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification used was
with the FCC Part 15.207 limits.


The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz. During the conducted
emission test, the EMI test receiver was set with the following configurations


                       Frequency Range                                                Receiver RBW

                       150 kHz - 30 MHz                                                     9 kHz
During the conducted emission test, the adapter was connected to the outlet of the LISN. Maximizing procedure
was performed on the six (6) highest emissions of the EUT. All data was recorded in the Quasi-peak and
average detection mode.


5.3    Test Equipment List and Details
   Description           Manufacture                 Model           Serial No.          Cal. Date.        Cal. Due.
                                                   Conduction Room
       LISN             Rohde & Schwarz             ENV216             101612            2019/02/21       2020/02/20

       LISN             Rohde & Schwarz             ENV216             101248            2019/06/26       2020/06/25

EMI Test Receiver       Rohde & Schwarz              ESR7              101419            2018/10/23       2019/10/22

   Pulse Limiter        Rohde & Schwarz             ESH3Z2           TXZEM104            2018/08/03       2019/08/02

      RF Cable                EMEC                 EM-CB5D               001             2019/07/01       2020/06/30

      Software                AUDIX                    E3              LKCO01              N.C.R             N.C.R

*Statement of Traceability: The testing equipment’s listed above have finished the calibration by Electronics Testing
Center, Taiwan (ETC) or other laboratories which were accredited by TAF or equivalent organizations. The calibration result
could be traceable to the International System of Units (SI).



5.4    Test Environmental Conditions

        Temperature:                       20-25 ℃                Relative Humidity:                   45-55 %
       ATM Pressure:                      1010 hPa                  Test Engineer:                    Ray Huang
         Test Date:                      2019-08-27




                                                                                                         Page 13 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                     Report No.: RLK190621001-00E


5.5     AC Line Conducted Emission Test Plot and Data

Mode: AC 120V/60 Hz, Co-location (2.4G+BLE), Line




Note:

Level = Read Level + Factor

Over Limit (Margin) = Level – Limit Line

Factor = (LISN, ISN, PLC or current probe) Factor + Cable Loss + Attenuator




                                                                                            Page 14 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                     Report No.: RLK190621001-00E




Mode: AC 120V/60 Hz, Co-location (2.4G+BLE), Neutral




Note:

Level = Read Level + Factor

Over Limit (Margin) = Level – Limit Line

Factor = (LISN, ISN, PLC or current probe) Factor + Cable Loss + Attenuator




                                                                                            Page 15 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                     Report No.: RLK190621001-00E



Mode: AC 110V/60 Hz, Co-location (2.4G+BLE), Line




Note:

Level = Read Level + Factor

Over Limit (Margin) = Level – Limit Line

Factor = (LISN, ISN, PLC or current probe) Factor + Cable Loss + Attenuator




                                                                                            Page 16 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                     Report No.: RLK190621001-00E




Mode: AC 110V/60 Hz, Co-location (2.4G+BLE), Neutral




Note:

Level = Read Level + Factor

Over Limit (Margin) = Level – Limit Line

Factor = (LISN, ISN, PLC or current probe) Factor + Cable Loss + Attenuator




                                                                                            Page 17 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                           Report No.: RLK190621001-00E


6 FCC §15.209, §15.205, §15.247(d), §2.1053, RSS-Gen Sec 8.9, 8.10, RSS-
  247 Sec 5.5 and LP0002 Sec 3.10, 2.7 and 2.8 – Spurious Unwanted
  Emissions

6.1   Applicable Standard

According to FCC §15.247 (d), LP0002 Sec 3.10,. ISED RSS-247 Sec 5.5
In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated
intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at
least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired
power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates
compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits
based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the
attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below the general limits
specified in §15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as
defined in §15.205(a), must also comply with the radiated emission limits specified in §15.209(a) (see
§15.205(c). (7) The provisions of §15.205 apply to intentional radiators operating under this section.


As per FCC §15.35(d): Unless otherwise specified, on any frequency or frequencies above 1000 MHz, the
radiated emission limits are based on the use of measurement instrumentation employing an average detector
function. Unless otherwise specified, measurements above 1000 MHz shall be performed using a minimum
resolution bandwidth of 1MHz.




                                                                                                    Page 18 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                      Report No.: RLK190621001-00E

As Per FCC §15.205(a) except as show in paragraph (d) of this section, only spurious emissions are permitted
in any of the frequency bands listed below:
          MHz                           MHz                         MHz                     GHz
       0.090-0.110                  13.36-13.41                399.9-410                  4.5-5.15
       0.495-0.505                 16.42-16.423                 608-614                   5.35-5.46
     2.1735-2.1905              16.69475-16.69525              960-1240                   7.25-7.75
       4.125-4.128                  25.5-25.67                1300-1427                   8.025-8.5
    4.17725-4.17775                 37.5-38.25                1435-1626.5                  9.0-9.2
    4.20725-4.20775                   73-74.6                1645.5-1646.5                 9.3-9.5
       6.215-6.218                   74.8-75.2                1660-1710                   10.6-12.7
    6.26775-6.26825                 108-121.94               1718.8-1722.2               13.25-13.4
    6.31175-6.31225                   123-138                 2200-2300                  14.47-14.5
       8.291-8.294                 149.9-150.05               2310-2390                  15.35-16.2
       8.362-8.366            156.52475-156.52525             2483.5-2500                 17.7-21.4
    8.37625-8.38675                 156.7-156.9               2690-2900                 22.01-23.12
    8.41425-8.41475              162.0125-167.17              3260-3267                   23.6-24.0
      12.29-12.293                 167.72-173.2               3332-3339                   31.2-31.8
   12.51975-12.52025                  240-285                 3345.8-3358                36.43-36.5
   12.57675-12.57725                 322-335.4                3600-4400                  Above 38.6
As per NCC Section 2.7,
              MHz                                      MHz                                MHz
          0.090 - 0.110                           167.72 - 173.20                    3260.0 - 3267.0
          0.490 - 0.510                           240.00 - 285.00                    3332.0 - 3339.0
          2.172 - 2.198                           322.00 - 335.40                    3345.8 - 3358.0
          3.013 - 3.033                           399.90 - 410.00                    3500.0 - 4400.0
          4.115 - 4.198                           608.00 - 614.00                    4500.0 - 5250.0
          5.670 - 5.690                           703.00 - 748.00                    5350.0 - 5460.0
          6.200 - 6.300                           758.00 - 803.00                    7250.0 - 7750.0
          8.230 - 8.400                           825.00 - 915.00                    8025.0 - 8500.0
         12.265 - 12.600                          930.00 - 1240.0                    9000.0 - 9200.0
         13.340 - 13.430                          1300.0 - 1427.0                    9300.0 - 9500.0
         14.965 - 15.020                          1435.0 - 1626.5                     10600 - 12700
         16.700 - 16.755                          1660.0 - 1785.0                     13250 - 13400
         19.965 - 20.020                          1805.0 - 1880.0                     14470 - 14500
         25.500 - 25.700                          1885.0 - 1900.0                     15350 - 16200
         37.475 - 38.275                          1905.0 - 1985.0                     17700 - 21400
         73.500 - 75.400                          2010.0 - 2025.0                     22010 - 23120
         108.00 - 138.00                          2110.0 - 2170.0                     23600 - 24000
         149.90 - 150.05                          2200.0 - 2300.0                     31200 - 31800
         156.70 - 156.90                          2310.0 - 2390.0                     36430 - 36500
         162.01 - 167.17                          2483.5 - 2900.0                      Above 38600


                                                                                              Page 19 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                 Report No.: RLK190621001-00E

As per FCC §15.209(a): Except as provided elsewhere in this Subpart, the emissions from an intentional
radiator shall not exceed the field strength levels specified in the following table:
             Frequency                               Field Strength                        Measurement Distance
               (MHz)                               (micro volts/meter)                           (meters)
            0.009 - 0.490                              2400/F(kHz)                                     300
            0.490 - 1.705                              24000/F(kHz)                                       30
             1.705 - 30.0                                    30                                           30
                30 - 88                                    100**                                          3
               88 - 216                                    150**                                          3
              216 - 960                                    200**                                          3
             Above 960                                      500                                           3


** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this Section shall
not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806MHz. However, operation within

these frequency bands is permitted under other sections of this Part, e.g., Sections 15.231 and 15.241.



6.2    EUT Setup and Test Procedure




                                                                                                               Page 20 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                     Report No.: RLK190621001-00E

Radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance with the
ANSI C63.10-2013. The specification used was the FCC Part 15.209 and FCC 15.247 Limits.

The system was investigated from 30 MHz to 26.5 GHz. During the radiated emission test, the EMI test receiver
was set with the following configurations measurement method 6.3 in ANSI C63.10.


                                                                                             Measurement
 Frequency Range              RBW                VBW        Detector         Duty cycle
                                                                                               method
    30-1000 MHz              120 kHz                /          QP                -                QP
                              1 MHz             3 MHz          PK                -                 PK
    Above 1 GHz               1 MHz             3 MHz         RMS              >98%               Ave
                              1 MHz               1/T          PK              <98%               Ave


Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations. All data was recorded in the Quasi-peak detector mode from 30 MHz to 1 GHz and PK
and average detector modes for frequencies above 1 GHz.




                                                                                             Page 21 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                                Report No.: RLK190621001-00E


6.3      Test Equipment List and Details

   Description            Manufacture                Model            Serial No.          Cal. Date.        Cal. Due.
                                                       966A Room
Active Loop Antenna        ETS-Lindgren               6502              00035796          2019/03/12        2020/03/11

Bilog Antenna with 6
                        Sunol & Mini-Circuits     JB6/UNAT-6+      A050115/15542_01       2018/12/11        2019/12/10
    dB Attenuator

   Horn Antenna                EMCO                 SAS-571               1983            2019/04/30        2020/04/29

   Horn Antenna            ETS-Lindgren               3116               62638            2018/08/29        2019/08/28

      Preamplifier            Sonoma                  310N               130601           2018/09/20        2019/09/19

      Preamplifier      EM Electronics Corp.       EM01G18G              060698           2019/04/12        2020/04/11

       Microware          EM Electronics
                                                   EM18G40G              060656           2019/01/11        2020/01/10
      Preamplifier         Corporatino

 EMI Test Receiver       Rohde & Schwarz              ESR7               101419           2018/10/23        2019/10/22

 Spectrum Analyzer       Rohde & Schwarz              FSV40              101204           2019/07/04        2020/07/03
                                                UFB197C-1-2362-
   Microflex Cable           UTIFLEX                                   225756-001         2019/07/01        2020/06/30
                                                   70U-70U
                                                UFA210A-1-3149-    MFR64639 226389-
   Microflex Cable           UTIFLEX                                                      2018/11/19        2019/11/18
                                                    300300               001
                                                 K1K50-UP0264-
   Microflex Cable           ROSNOL                                     160309-1          2019/03/04        2020/03/03
                                                  K1K50-450CM
                                                 K1K50-UP0264-
   Microflex Cable           ROSNOL                                     160309-2          2019/01/16        2020/01/15
                                                  K1K50-80CM

      Turn Table             Champro                TT-2000             060772-T             N.C.R              N.C.R

   Antenna Tower             Champro             AM-BS-4500-B           060772-A             N.C.R              N.C.R

       Controller            Champro                EM1000               60772               N.C.R              N.C.R

       Software                AUDIX                   E3               LKCO01               N.C.R              N.C.R

*Statement of Traceability: The testing equipment’s listed above have finished the calibration by Electronics Testing
Center, Taiwan (ETC) or other laboratories which were accredited by TAF or equivalent organizations. The calibration result
could be traceable to the International System of Units (SI).


6.4      Test Environmental Conditions

         Temperature:                       20-25 ℃               Relative Humidity:                    45-55 %
        ATM Pressure:                       1014hPa                  Test Engineer:                    Leo Chang
           Test Date:              2019-06-19~2019-08-06                     -                              -




                                                                                                          Page 22 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                  Report No.: RLK190621001-00E



6.5    Radiated Emission Test Plot and Data


Wi-Fi 2.4G mode - 4TX
Transmitting mode (Pre-scan with three orthogonal axis, and worse case as Z axis)
Below 1G (30 MHz-1 GHz) test the output power worst mode


                          Horizontal                                       Vertical




Result = Reading + Correct Factor

Margin = Result – Limit
Correct Factor = Antenna Factor + Cable Loss – Amplifier Gain
Spurious emissions more than 20 dB below the limit were not reported




                                                                                         Page 23 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)         Report No.: RLK190621001-00E


Wi-Fi 2.4G mode - 4TX

Above 1G (1 GHz-26.5 GHz):


                                          802.11b mode: 2412MHz
                      Horizontal                                  Vertical




                                         802.11b mode: 2437 MHz
                      Horizontal                                  Vertical




                                                                                Page 24 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)         Report No.: RLK190621001-00E




                                         802.11b mode: 2462 MHz
                      Horizontal                                  Vertical




                                         802.11g mode: 2412 MHz
                      Horizontal                                  Vertical




                                                                                Page 25 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)         Report No.: RLK190621001-00E




                                         802.11g mode: 2437 MHz
                      Horizontal                                  Vertical




                                         802.11g mode: 2462 MHz
                      Horizontal                                  Vertical




                                                                                Page 26 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)          Report No.: RLK190621001-00E




                                     802.11n HT20 mode: 2412 MHz
                      Horizontal                                   Vertical




                                     802.11n HT20 mode: 2437 MHz
                      Horizontal                                   Vertical




                                                                                 Page 27 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)           Report No.: RLK190621001-00E




                                     802.11n HT20 mode: 2462 MHz
                      Horizontal                                    Vertical




                                     802.11ax HE20 mode: 2412 MHz
                      Horizontal                                    Vertical




                                                                                  Page 28 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)           Report No.: RLK190621001-00E




                                     802.11ax HE20 mode: 2437 MHz
                      Horizontal                                    Vertical




                                     802.11ax HE20 mode: 2462 MHz
                      Horizontal                                    Vertical




                                                                                  Page 29 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)         Report No.: RLK190621001-00E


ChillWave mode -

Above 1G (1 GHz-26.5 GHz):


                                          802.11g mode: 2412MHz
                      Horizontal                                  Vertical




                                         802.11g mode: 2437 MHz
                      Horizontal                                  Vertical




                                                                                Page 30 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)         Report No.: RLK190621001-00E




                                         802.11g mode: 2462 MHz
                      Horizontal                                  Vertical




                                                                                Page 31 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)                  Report No.: RLK190621001-00E


BLE mode
Transmitting mode (Pre-scan with three orthogonal axis, and worse case as Z axis)
Below 1G (30 MHz-1 GHz) test the output power worst mode


                          Horizontal                                       Vertical




Result = Reading + Correct Factor

Margin = Result – Limit

Correct Factor = Antenna Factor + Cable Loss – Amplifier Gain
Spurious emissions more than 20 dB below the limit were not reported




                                                                                         Page 32 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)        Report No.: RLK190621001-00E


Above 1G (1 GHz-26.5 GHz):


                                            BLE mode: 2402 MHz
                      Horizontal                                 Vertical




                                            BLE mode: 2426 MHz
                      Horizontal                                 Vertical




                                                                               Page 33 of 34


Bay Area Compliance Laboratories Corp.(Linkou Laboratory)             Report No.: RLK190621001-00E




                                            BLE mode: 2480 MHz
                      Horizontal                                      Vertical




                                          ----- END OF REPORT -----




                                                                                    Page 34 of 34



Document Created: 2019-09-14 02:47:36
Document Modified: 2019-09-14 02:47:36

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC