Test Report_MPE Study

FCC ID: LDK102094

RF Exposure Info

Download: PDF
FCCID_2749409

Custom EMC Test Report No: EDCS - 1514660




             Maximum Permissible Exposure (MPE) Calculations

                            For AIR-RM3010l-B-K9

                                FCC ID: LDK102094

                                    Also Covers:

                              AIR-AP1572xy-C-K9
                              AIR-AP1572xy-N-K9
                              AIR-AP1572xy-S-K9
                              AIR-AP1572xy-T-K9
                              AIR-AP1572xy-Z-K9


                         Data for 5.15-5.25GHz is for –B domain only




                         Testing - Certificate Number: 1178-01




Revision 2


Custom EMC Test Report No: EDCS - 1514660




Devices are subject to the radio frequency radiation exposure requirements specified in Sec. 1.1307(b),
Sec. 2.1091 and Sec. 2.1093 of this chapter, as appropriate. All equipment shall be considered to operate
in a ``general population/uncontrolled'' environment. Applications for equipment authorization of devices
operating under this section must contain a statement confirming compliance with these requirements for
both fundamental emissions and unwanted emissions. Technical information showing the basis for this
statement must be submitted to the Commission upon request.

        Given
                E=√(30*P*G)/d and       S=E^2/3770
        where
                E=Field Strength in Volts/meter
                P=Power in Watts
                G=Numeric Antenna Gain
                d=Distance in meters
                S=Power Density in mW/cm^2

        Combine equations and rearrange the terms to express the distance as a function of the
        remaining variables:
                d=√((30*P*G)/(3770*S))

        Changing to units of power in mW and distance in cm, using:
               P(mW)=P(W)/1000                 d(cm)=100*d(m)
        yields
               d=100*√((30*(P/1000)*G)/(3770*S))
               d=0.282*√(P*G/S)
        where
               d=Distance in cm
               P=Power in mW
               G=Numerica Antenna Gain
               S=Power Density in mW/cm^2

        Substituting the logarithmic form of power and gain using:
                P(mW)=10^(P(dBm)/10)             G(numeric)=10^(G(dBi)/10)
        yields
                d=0.282*10^((P+G)/20)/√S                                                 Equation (1)
        and
                s=((0.282*10^((P+G)/20))/d)^2                                            Equation (2)
        where
                d=MPE distance in cm
                P=Power in dBm
                G=Antenna Gain in dBi
                S=Power Density in mW/cm^2


Custom EMC Test Report No: EDCS - 1514660




      Equation (1) and the measured peak power are used to calculate the MPE distance. Note that for
      mobile or fixed location transmitters such as an access point, the minimum separation distance is
      20 cm even if the calculations indicate that the MPE distance may be less.

      S=1mW/cm^2 maximum. Using the peak power levels recorded in the test report along with
      Equation 1 above, the MPE distances are calculated as follows.


                             Peak
                   Power   Transmit Antenna   MPE
       Frequency   Density  Power    Gain   Distance Limit                                         Margin
         (MHz)   (mW/cm^2)  (dBm)    (dBi)    (cm)   (cm)                                           (cm)
          2412       1       21.0      4      5.01    20                                           14.99
          2437       1       26.4      4      9.34    20                                           10.66
          2462       1       23.0      4      6.31    20                                           13.69
          5180       1       22.0      4      5.63    20                                           14.37
          5240       1       23.0      4      6.31    20                                           13.69
          5260       1        22       4      5.63    20                                           14.37
          5320       1        21       4      5.01    20                                           14.99
          5500       1        16       4      2.82    20                                           17.18
          5580       1        22       4      5.63    20                                           14.37
          5720       1        21       4      5.01    20                                           14.99
          5745       1        19       4      3.98    20                                           16.02
          5785       1        23       4      6.31    20                                           13.69




       To maintain compliance, installations will assure a separation distance of at least 20cm.

      Using Equation 2, the MPE levels (s) at 20 cm are calculated as follows:

                                         Peak
                           MPE                        Power             Limit
                                       Transmit                                        Margin
         (MHz)           Distance                     Density        Frequency
                                        Power                                        (mW/cm^2)
                           (cm)                     (mW/cm^2)        (mW/cm^2)
                                        (dBm)
       2437+5785            20           28.04          0.32              1              0.68



Document Created: 2015-09-03 09:30:23
Document Modified: 2015-09-03 09:30:23

© 2024 FCC.report