5180-5240 Report Setup Photos

FCC ID: LDK102091

Test Setup Photos

Download: PDF
FCCID_2128003

Custom EMC Test Report No: EDCS - 1325300




                           Test Setup for Conducted Measurements




                             Test Setup for Radiated Measurements

                                              Page No: 584 of 591

  This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                    Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 1325300




Conducted Emissions




Test Result Table
Frequency                                    Level       Measurement
            Raw dBuV Cable Loss Factors dB                             Line   Limit dBuV Margin dB Pass /Fail Comments
MHz                                          dBuV        Type
0.168       29.9      21.2      0.2          51.3        Qp            L      65.1      -13.7     Pass
0.256       21.3      20.7      0.1          42.1        Qp            L      61.6      -19.5     Pass
0.222       23.9      20.9      0.1          44.9        Qp            L      62.7      -17.9     Pass
2.695       19        20        0            39          Qp            L      56        -17       Pass
0.826       16.7      20        0            36.7        Qp            L      56        -19.3     Pass
0.618       14.2      20        0            34.3        Qp            L      56        -21.7     Pass
0.293       17.7      20.6      0            38.3        Qp            N      60.4      -22.1     Pass
1.07        18.4      20        0            38.4        Qp            N      56        -17.6     Pass
2.834       17.2      20        0            37.2        Qp            N      56        -18.8     Pass
0.166       30.8      21.3      0.2          52.3        Qp            N      65.2      -12.9     Pass
2.221       18.6      20        0            38.7        Qp            N      56        -17.3     Pass
4.111       15.3      20        0            35.4        Qp            N      56        -20.6     Pass
0.168       17        21.2      0.2          38.4        Av            L      55.1      -16.7     Pass
0.256       -0.4      20.7      0.1          20.4        Av            L      51.6      -31.2     Pass
0.222       1.4       20.9      0.1          22.4        Av            L      52.7      -30.3     Pass
2.695       7         20        0            27.1        Av            L      46        -18.9     Pass
0.826       5.5       20        0            25.6        Av            L      46        -20.4     Pass
0.618       0.9       20        0            21          Av            L      46        -25       Pass
0.293       8         20.6      0            28.6        Av            N      50.4      -21.8     Pass
1.07        7         20        0            27          Av            N      46        -19       Pass
2.834       4         20        0            24          Av            N      46        -22       Pass
0.166       18.2      21.3      0.2          39.6        Av            N      55.2      -15.5     Pass
2.221       6.5       20        0            26.5        Av            N      46        -19.5     Pass
4.111       3.5       20        0            23.6        Av            N      46        -22.4     Pass




                                                     Page No: 585 of 591

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 1325300




                           Test Setup for Conducted Measurements




                                              Page No: 586 of 591

  This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                    Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 1325300




Radiated emissions




Test Result Table
Frequency Raw     Cable             Level    Measurement                           Limit    Margin   Pass
                           AF dB                         Pol      Hgt cm Azt Deg                             Comments
MHz       dBuV    Loss              dBuV/m   Type                                  dBuV/m   dB       /Fail
30.449    22.5    0.7      -6.8     16.3     Qp          V        149     290      30       -13.7    Pass
63.207    38.4    1        -20.2    19.2     Qp          V        197     87       30       -10.8    Pass
144.011 34        1.4      -14.9    20.5     Qp          V        119     255      30       -9.5     Pass
77.91     35.5    1.1      -19.8    16.8     Qp          V        119     19       30       -13.2    Pass
853.084 20.6      3.3      -6.4     17.5     Qp          V        274     6        37       -19.5    Pass
168.944 27.9      1.5      -15.7    13.7     Qp          V        115     34       30       -16.3    Pass




                                               Page No: 587 of 591

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 1325300




                                              Page No: 588 of 591

  This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                    Cisco Systems, Inc. Company Confidential



Document Created: 2013-11-26 09:17:22