Setup Photos for 1532E_DFS_USA_Report

FCC ID: LDK102089P

Test Setup Photos

Download: PDF
FCCID_2129587

Custom EMC Test Report No: EDCS- 1277546




     DFS Setup

     The test setup is constructed of the following equipment:

     Radar Test Signal Generator
       National Instruments NI PXI-1042 8-Slot 3U Chassis
       National Instruments NI PXI-5422 16-Bit 200MS/s Arbitrary Waveform Generator (Qty. 2)
       Agilent N5182A MXG Signal Generator
     Agilent E4448A Spectrum Analyzer
     Mini-Circuits ZFSC-2-9G Splitter/Combiner (Qty. 1)
     Weinschel 1594 4 to 1 power Splitter/Combiner (Qty. 1)
     Ditom Microwave D3C-4080-11 Circulator/Isolator (Qty. 1)
     Mini-Circuits BW-S30W2 30dB Attenuator (Qty. 4)
     Mini-Circuits BW-S6W2 30dB Attenuator (Qty. 5)
     Megaphase SF26 S1S1 36” Coaxial Cable (Qty. 2)
     MicroCoax 18” Coaxial Cable (Qty. 3)
     Dell 600M Laptop (Qty. 2: 1 for wireless client, 1 for MPEG server)
     Cisco-Linksys WPC600N 802.11n NIC card (wireless client)

     The waveform parameters from within the bounds of the signal type are selected randomly using
     uniform distribution.

                                                Page No: 13 of 64

  This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                    Cisco Systems, Inc. Company Confidential



Document Created: 2013-11-27 10:15:10
Document Modified: 2013-11-27 10:15:10