Appendix B:      Emission Test Results
Testing Laboratory: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134, USA

Radiated Spurious Emissions
Radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), must also
comply with the radiated emission limits specified in Section 15.209(a) (see Section 15.205(c)).

        Using Vasona, configure the spectrum analyzer as shown below (be sure to enter all losses between the
        transmitter output and the spectrum analyzer). Place the radio in continuous transmit mode.

                 Span:                    1GHz – 18 GHz
                 Reference Level:         80 dBuV
                 Attenuation:             10 dB
                 Sweep Time:              Coupled
                 Resolution Bandwidth:    1MHz
                 Video Bandwidth:         1 MHz for peak, 10 Hz for average
                 Detector:                Peak

        Maximize Turntable (find worst case table angle), Maximize Antenna (find worst case height)

         Save 2 plots:    1) Average Plot (Vertical and Horizontal), Limit= 54dBuV @3m
                          2) Peak plot (Vertical and Horizontal), Limit = 74dBuV @3m


        Place a marker at the end of the restricted band closest to the transmit frequency to show compliance.
        Also measure any emissions in the restricted bands.

This report represents the worst case data for all supported operating modes and antennas.
There are no measurable emissions above 18 GHz.




                                               Page No: 240 of 252

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 1250399




                                                                              Spurious
                                                                  Data        Emission
Frequency                                                         Rate          Level          Limit
  (MHz)                        Mode                              (Mbps)       (dBuV/m)       (dBuV/m)
              Non HT-20, 6 to 54 Mbps                              6             <54            54
              Non HT-20 Beam Forming, 6 to 54 Mbps                 6             <54            54
  5500        HT-20, M0 to M23                                     m0            <54            54
              HT-20 STBC, M0 to M7                                 m0            <54            54
              HT-20 Beam Forming, M0 to M23                        m0            <54            54

              Non HT-20, 6 to 54 Mbps                               6             <54            54
              Non HT-20 Beam Forming, 6 to 54 Mbps                  6             <54            54
  5700        HT-20, M0 to M23                                      m0            <54            54
              HT-20 STBC, M0 to M7                                  m0            <54            54
              HT-20 Beam Forming, M0 to M23                         m0            <54            54

              Non HT-40 Duplicate, 6-54 Mbps                                      <54            54
              HT-40, M0 to M23                                      6             <54            54
5500/5520
              HT-40 STBC, M0 to M7                                  m0            <54            54
              HT-40 Beam Forming, M0 to M23                         m0            <54            54

              Non HT-40 Duplicate, 6-54 Mbps                        6             <54            54
              HT-40, M0 to M23                                      m0            <54            54
5660/5680
              HT-40 STBC, M0 to M7                                  m0            <54            54
              HT-40 Beam Forming, M0 to M23                         m0            <54            54




                                              Page No: 241 of 252

  This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                    Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 1250399




Radiated Transmitter Spurs, 5500 MHz, All Rates, All Modes, Average




Radiated Transmitter Spurs, 5700 MHz, All Rates, All Modes, Average




Radiated Transmitter Spurs, 5500 MHz, All Rates, All Modes, Peak

                                               Page No: 242 of 252

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 1250399




Radiated Transmitter Spurs, 5700 MHz, All Rates, All Modes, Peak




                                               Page No: 243 of 252

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 1250399




Receiver Radiated Spurious Emissions

Radiated Receiver Spurs, All Rates, All Modes, Average




Radiated Receiver Spurs, All Rates, All Modes, Peak




                                               Page No: 244 of 252

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 1250399




Radiated Test Setup Photo




                                               Page No: 245 of 252

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 1250399




Conducted Emissions




Test Results Table
Frequency Raw       Cable Factors Level       Measureme Line     Limit      Margin Pass /Fail Comments
MHz         dBuV    Loss      dB     dBuV     nt Type            dBuV       dB
    0.15736      24      21.3    0.1     45.4         Av       N       55.6    -10.2   Pass
   0.15736     32.8     21.3     0.1     54.2        Qp        N     65.6    -11.4     Pass
   0.15288       32     21.4     0.1     53.5        Qp        N     65.8    -12.4     Pass
      3.424    22.7      20        0     42.8        Qp        N       56    -13.2     Pass
   0.15288       21     21.4     0.1     42.4        Av        L     55.8    -13.4     Pass
      3.351    22.5      20      0.1     42.6        Qp        N       56    -13.4     Pass
      3.351    11.1      20      0.1     31.2        Av        N       46    -14.8     Pass
      3.351    10.9      20      0.1     30.9        Av        L       46    -15.1     Pass
      3.424    20.3      20        0     40.3        Qp        L       56    -15.7     Pass
      3.424    10.2      20        0     30.3        Av        N       46    -15.7     Pass
   0.15288     28.1     21.4     0.1     49.6        Qp        L     65.8    -16.3     Pass
      3.424     9.4      20        0     29.5        Av        L       46    -16.5     Pass
      2.158     9.4      20        0     29.5        Av        N       46    -16.5     Pass
   0.15736     27.5     21.3     0.1     48.9        Qp        L     65.6    -16.7     Pass
      2.158    18.6      20        0     38.7        Qp        N       56    -17.3     Pass
      2.158    18.6      20        0     38.6        Qp        L       56    -17.4     Pass
      2.158     8.5      20        0     28.5        Av        L       46    -17.5     Pass
      3.351    17.6      20      0.1     37.6        Qp        L       56    -18.4     Pass
   0.23346     20.6     20.9       0     41.5        Qp        L     62.3    -20.8     Pass
   0.23346     19.8     20.9       0     40.7        Qp        N     62.3    -21.6     Pass
      4.916     4.3      20        0     24.4        Av        N       46    -21.6     Pass
      4.916     2.5      20        0     22.6        Av        L       46    -23.4     Pass
      4.916    11.8      20        0     31.9        Qp        N       56    -24.1     Pass


                                                          Page No: 246 of 252

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 1250399




Frequency Raw        Cable Factors Level       Measureme Line     Limit      Margin Pass /Fail Comments
MHz         dBuV     Loss      dB     dBuV     nt Type            dBuV       dB
    0.15288      7.8      21.4    0.1     29.2         Av       N       55.8    -26.6   Pass
      4.916       9       20        0     29.1        Qp        L       56    -26.9     Pass
   0.15736       5.7    21.3      0.1     27.1        Av        L     55.6    -28.5     Pass
   0.23346      -0.1    20.9        0     20.8        Av        N     52.3    -31.6     Pass
   0.23346      -1.5    20.9        0     19.4        Av        L     52.3    -32.9     Pass




Title: Power Line Conducted Emissions Test Setup




                                                           Page No: 247 of 252

    This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                      Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 1250399




Radiated emissions




Test Results Table
Frequency Raw        Cable AF dB Level       Measureme Pol Hgt Azt Limit    Margin Pass /Fail Comments
MHz         dBuV     Loss           dBuV/m nt Type         cm Deg dBuV/m dB
      34.65     30.1      0.6 -10.1     20.6        Qp    V 124 218      30      -9.4  Pass
    44.239    36.6     0.7    -17.2   20.2        Qp     V 198 221       30     -9.8    Pass
   120.013    32.5     1.2    -13.6   20.2        Qp     V 135   87      30     -9.8    Pass
   110.373    33.2     1.2    -14.7   19.7        Qp     V 131 175       30    -10.3    Pass
    66.612    37.4       1    -19.7   18.6        Qp     V 102 271       30    -11.4    Pass
    46.154    33.9     0.7    -18.3   16.3        Qp     V 254 195       30    -13.7    Pass




                                                       Page No: 248 of 252

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 1250399




Title: Radiated Emissions 10m Test Distance




                                              Page No: 249 of 252

  This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                    Cisco Systems, Inc. Company Confidential



Document Created: 2013-04-18 14:39:48
Document Modified: 2013-04-18 14:39:48

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC