Report

FCC ID: LDK102061

Test Report

Download: PDF
FCCID_1155351

Custom EMC Test Report No: EDCS - 789978




                                       Class II Change Report




                                     AIR-RM1252A-A-K9

                             5GHz 802.11a MIMO Radio Module

                                         FCC ID: LDK102061

                                           IC: 2461B-102061

                                      Against the following Specifications:
                                                CFR47 Part 15.247
                                                CFR47 Part 15.407
                                                      RSS210




                                                  Cisco Systems

                                              170 West Tasman Drive

                                               San Jose, CA 95134




                                                Page No: 1 of 21

  This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                    Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




This test report has been electronically authorized and archived using the CISCO Engineering Document Control system.

SECTION 1: OVERVIEW .........................................................................................................................................3
    1.1 TEST SUMMARY ...................................................................................................................................................3
SECTION 2: ASSESSMENT INFORMATION ......................................................................................................4
    2.1 GENERAL .............................................................................................................................................................4
    2.4 TESTING FACILITIES .............................................................................................................................................5
    2.6 EUT DESCRIPTION ...............................................................................................................................................5
    LEGACY OFDM, SINGLE ANTENNA, 6 TO 54 MBPS ...................................................................................................5
    LEGACY OFDM, DUAL ANTENNAS, 6 TO 54 MBPS ...................................................................................................5
    LEGACY OFDM , DUAL ANTENNAS WITH BEAM FORMING, 6 TO 54 MBPS ...............................................................5
    HT- 20 MHZ, DUAL ANTENNAS, MCS0 TO MCS15 ..................................................................................................5
    DUPLICATE 2X20 MHZ, DUAL ANTENNAS, 6 MBPS ..................................................................................................5
    HT- 40 MHZ, DUAL ANTENNAS, MCS0 TO MCS15 ..................................................................................................5
SECTION 4: SAMPLE DETAILS .............................................................................................................................6
    4.1 SAMPLE DETAILS (PHOTOGRAPHS OF THE TEST SAMPLES, WHERE APPROPRIATE CAN BE FOUND IN APPENDIX H) 6
    4.2 SYSTEM DETAILS .................................................................................................................................................6
    4.3 MODE OF OPERATION DETAILS ............................................................................................................................6
APPENDIX B:                      EMISSION TEST RESULTS ..................................................................................................7

TESTING LABORATORY: CISCO SYSTEMS, INC., 170 WEST TASMAN DRIVE, SAN JOSE, CA 95134,
USA ...............................................................................................................................................................................7

APPENDIX C:                  TEST EQUIPMENT/SOFTWARE USED TO PERFORM THE TEST...............................21




                                                                            Page No: 2 of 21

     This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                       Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Section 1: Overview
1.1 Test Summary

samples were assessed against the tests detailed in section 3 under the requirements of the following
specifications:


Emission                                                     Immunity

CFR47 Part 15.247                                            N/A

CFR47 Part 15.407
RSS210

The specifications listed above represent actual tests performed to demonstrate compliance against the specifications
and basic standards listed on the front cover of this report. This list is not a one to one match to the front cover for one
or more of the following reasons.
1. Basic standards call up many different test phenomena specifications such as the 61000-4-X series. The basic
    standards define which elements and levels shall be applied from these specifications and as such it is not
    appropriate to list the individual specifications on the front cover.
2. A Standard listed on the front cover may be required in a particular country but is not appropriate for the particular
    technologies included in the equipment under test. E.g. You cannot test a DC product to the mains Harmonics
    requirements in EN61000-3-2. See section 3.2.
3. Test results against a particular standard or specification may be included in a different test report. See section 3.2
    for an EDCS reference of this data.
4. Where appropriate, Cisco may have substituted a later revision of a basic standard to those referenced in the
    specification on the front sheet of this test report. This decision was based upon improved test methodology and
    repeatability and/or where the newer revision represented a more stringent test.
5. Where relevant, testing has been carried out to the requirements of both EN and IEC Specifications. This was
    possible because of the similarities of the test methods involved and the Cisco EMC test procedures.
6. Testing may have been performed to an equivalent test that satisfies the requirements of the standards and
    specifications listed on the front cover of the report. See section 3.2.
7. Where radiated emissions testing has been performed to EN55022/CISPR22 the additional requirements of VCCI:
    V- 3/2006.04, EN55022: 1994 +A1/2 and CAN/CSA- CISPR 22-02 have also been evaluated unless otherwise
    stated.
8. Testing to the requirements of CFR47 Part 15 was performed against the CISPR22 limits. The results are therefore
    deemed satisfactory evidence of compliance with Industry Canada Interference Causing Equipment Standard
    ICES-003.
9. Where assessment has been performed to CISPR24, all the applicable test requirements may have not been
    covered. Refer to the results section for the tests performed.
Notes:

1)   Where a specification listed on the front cover of this report has deviations from the basic standards listed above,
     the additional technical requirements of the specification were also assessed.
2)   Where appropriate, Cisco may have substituted a later revision of a basic standard to those referenced in the
     specification on the front sheet of this test report. This decision was based upon improved test methodology and
     repeatability and/or where the newer revision represented a more stringent test.
3)   Where relevant, testing has been carried out to the requirements of both EN and IEC Specifications. This was
     possible because of the similarities of the test methods involved and the Cisco EMC test procedures.




                                                    Page No: 3 of 21

     This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                       Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Section 2: Assessment Information


2.1 General
This report contains an assessment of an apparatus against Electromagnetic Compatibility Standards based upon tests
carried out on the samples submitted. The testing was performed by and for the use of Cisco systems Inc:


With regard to this assessment, the following points should be noted:


a)        The results contained in this report relate only to the items tested and were obtained in the period between the
          date of the initial assessment and the date of issue of the report. Manufactured products will not necessarily
          give identical results due to production and measurement tolerances.
b)        The apparatus was set up and exercised using the configuration and modes of operation
          defined in this report only.
c)        Where relevant, the apparatus was only assessed using the susceptibility criteria defined
           in this report and the Test Assessment Plan (TAP).
d)        All testing was performed under the following environmental conditions:
          Temperature                15°C to 35°C (54°F to 95°F)
          Atmospheric Pressure       860mbar to 1060mbar (25.4" to 31.3")
          Humidity                  10% to 75*%

          *[Where applicable] For ESD testing the humidity limits used were 30% to 60% and for EFT/B tests the
          humidity limits used were 25% to 75%.
e)        All AC testing was performed at one or more of the following supply voltages:
           110V 60 Hz (+/-20%)
           220V 50 Hz (+/-20%)


This report must not be reproduced except in full, without written approval of Cisco Systems.




                                                    Page No: 4 of 21

     This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                       Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




2.2 Date of start of testing
13-July-2009

2.3 Report Issue Date
Cisco uses an electronic system to issue, store and control the revision of test reports. This system is called the
Engineering Document Control System (EDCS). The actual report issue date is embedded into the original file on
EDCS. Any copies of this report, either electronic or paper, that are not on EDCS must be considered uncontrolled
2.4 Testing facilities
This assessment was performed by:


Testing Laboratory
   Cisco Systems, Inc.,             Cisco Systems, Inc.
   4125 Highlander Parkway          170 West Tasman Drive
   Richfield, OH 44286              San Jose, CA 95134
   USA                              USA


Test Engineers

James Nicholson

2.5 Equipment Assessed (EUT)

AIR-RM1252A-A-K9 5GHz 802.11a MIMO Radio Module.

2.6 EUT Description
 The AIR-RM1252A-A-K9 5GHz 802.11a MIMO radio module operates in the AIR-AP1250 series access point, and may
operate simultaneously with the AIR-RM1252G-A-K9 2.4GHz 802.11b/g MIMO radio module. The following modes of
operation are supported. The modes are further defined in the radio Theory of Operation. The modes included in this
report represent the worst case data for all modes.


         Legacy OFDM, Single Antenna, 6 to 54 Mbps
         Legacy OFDM, Dual Antennas, 6 to 54 Mbps
         Legacy OFDM , Dual Antennas with Beam Forming, 6 to 54 Mbps
         HT- 20 MHz, Dual Antennas, MCS0 to MCS15
         Duplicate 2x20 MHz, Dual Antennas, 6 Mbps
         HT- 40 MHz, Dual Antennas, MCS0 to MCS15

This report adds the following antenna:

         AIR-ANT5160NP-R            6 dBi MIMO Patch Antenna with RP-TNC Connectors




                                                  Page No: 5 of 21

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Section 4: Sample Details

Note: Each sample was evaluated to ensure that its condition was suitable to be used as a test sample prior to the
commencement of testing. Please also refer to the “Justification for worst Case test Configuration” section of this report
for further details on the selection of EUT samples.
4.1 Sample Details (Photographs of the test samples, where appropriate can be found in appendix H)

 Sample     Equipment Details         Part               Manufacturer     Hardware     Firmware     Software    Serial
 No.                                  Number                              Rev.         Rev.         Rev.        Number
 S01        AIR-RM1252A-A-K9          73-10425-05        Cisco Systems    NA           NA           NA          RFD1041
                                                                                                                0051
 S02        AIR-AP1250                800-270630-05      Cisco Systems    NA           NA           NA          FOC1039
                                                                                                                1YLB
 S03        AIR-ANT5160NP-R           NA                 Cisco Systems    NA           NA           NA          NA
 S04        AIR-PWR-SPLY1             341-0211-01        Cisco Systems    NA           NA           NA          DTH1030
                                                                                                                902Z


4.2 System Details

  System #                                 Description                                          Samples
 1               EUT                                                             S01, S02, S03 and S04


4.3 Mode of Operation Details

  Mode#             Description                                            Comments
 1            Continuous Transmitting      Continuous Transmitting




                                                    Page No: 6 of 21

     This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                       Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Appendix B: Emission Test Results
Testing Laboratory: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134, USA


Radiated Bandedge
Radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), must also
comply with the radiated emission limits specified in Section 15.209(a) (see Section 15.205(c)).

       Using Vasona, configure the spectrum analyzer as shown below (be sure to enter all losses between the
       transmitter output and the spectrum analyzer). Place the radio in continuous transmit mode.


                Reference Level:        110 dBuV
                Attenuation:            20 dB
                Sweep Time:             Coupled
                Resolution Bandwidth:   1MHz
                Video Bandwidth:        1 MHz for peak, 10 Hz for average
                Detector:               Peak

       Maximize Turntable (find worst case table angle), Maximize Antenna (find worst case height)

        Save 2 plots:     1) Average Plot (Vertical and Horizontal), Limit= 54dBuV @3m
                          2) Peak plot (Vertical and Horizontal), Limit = 74dBuV @3m


       Place a marker at the end of the restricted band closest to the transmit frequency to show compliance.
       Also measure any emissions in the restricted bands.


                                     Radiated
                                      Band
                                      Edge
Frequency                  Data Rate  Level   Limit                  Margin
  (MHz)         Mode        (Mbps) (dBuV/m) (dBuV/m)                  (dB)
   5180          Dual          54          50.1          54           3.86
 5180/5200    Duplicate        6           53.3          54            0.7
   5320         Dual           54          53.1          54           0.91
 5300/5320    Duplicate        6           53.8          54            0.2
   5500         Dual           54          51.4          54           2.58
 5500/5520    Duplicate         6          52.5          54           1.48
 5660/5680    Duplicate        6           60.5         68.2          7.71
   5700         Dual           54          59.3         68.2          8.86
   5745       Dual BF          54          67.5         78.2         10.67
 5745/5765    Duplicate        6           73.3         78.2         4.92
 5785/5805    Duplicate         6          61.6         78.2         16.62
   5825        Dual BF         54          53.4         78.2         24.85




                                                  Page No: 7 of 21

  This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                    Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Radiated Bandedge, 5180 MHz, 54, Non HT-20, Dual Transmit Path, Average




Radiated Bandedge, 5180/5200 MHz, 6 Mbps, Non HT-40 Duplicate, Dual Transmit Paths, Average




                                                 Page No: 8 of 21

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Radiated Bandedge, 5320 MHz, 54, Non HT-20, Dual Transmit Path, Average




Radiated Bandedge, 5300/5320 MHz, 6 Mbps, Non HT-40 Duplicate, Dual Transmit Paths, Average




                                                 Page No: 9 of 21

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Radiated Bandedge, 5500 MHz, 54, Non HT-20, Dual Transmit Path, Average




Radiated Bandedge, 5500/5520 MHz, 6 Mbps, Non HT-40 Duplicate, Dual Transmit Paths, Average




                                                 Page No: 10 of 21

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Radiated Bandedge, 5560/5680 MHz, 6 Mbps, Non HT-40 Duplicate, Dual Transmit Paths, Average




Radiated Bandedge, 5700 MHz, 54, Non HT-20, Dual Transmit Path, Average




                                                 Page No: 11 of 21

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Radiated Bandedge, 5745 MHz, 54, Non HT-20, Dual Beamforming Transmit Paths, Average




Radiated Bandedge, 5745/5765 MHz, 6 Mbps, Non HT-40 Duplicate, Dual Transmit Paths, Average




                                                 Page No: 12 of 21

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Radiated Bandedge, 5785/5805 MHz, 6 Mbps, Non HT-40 Duplicate, Dual Transmit Paths, Average




Radiated Bandedge, 5825 MHz, 54, Non HT-20, Dual Beamforming Transmit Path, Average




                                                 Page No: 13 of 21

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Radiated Bandedge, 5180 MHz, 54, Non HT-20, Dual Transmit Path, Peak




Radiated Bandedge, 5180/5200 MHz, 6 Mbps, Non HT-40 Duplicate, Dual Transmit Paths, Peak




                                                 Page No: 14 of 21

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Radiated Bandedge, 5320 MHz, 54, Non HT-20, Dual Transmit Path, Peak




Radiated Bandedge, 5300/5320 MHz, 6 Mbps, Non HT-40 Duplicate, Dual Transmit Paths, Peak




                                                 Page No: 15 of 21

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Radiated Bandedge, 5500 MHz, 54, Non HT-20, Dual Transmit Path, Peak




Radiated Bandedge, 5500/5520 MHz, 6 Mbps, Non HT-40 Duplicate, Dual Transmit Paths, Peak




                                                 Page No: 16 of 21

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Radiated Bandedge, 5560/5680 MHz, 6 Mbps, Non HT-40 Duplicate, Dual Transmit Paths, Peak




Radiated Bandedge, 5700 MHz, 54, Non HT-20, Dual Transmit Path, Peak




                                                 Page No: 17 of 21

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Radiated Bandedge, 5745 MHz, 54, Non HT-20, Dual Beamforming Transmit Paths, Peak




Radiated Bandedge, 5745/5765 MHz, 6 Mbps, Non HT-40 Duplicate, Dual Transmit Paths, Peak




                                                 Page No: 18 of 21

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Radiated Bandedge, 5785/5805 MHz, 6 Mbps, Non HT-40 Duplicate, Dual Transmit Paths, Peak




Radiated Bandedge, 5825 MHz, 54, Non HT-20, Dual Beamforming Transmit Path, Peak




                                                 Page No: 19 of 21

   This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                     Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Radiated Spurs / Harmonics
The Radiated Spurious Emissions and Harmonics data included in the original filing continue to
represent the worst case values for all supported modes and antennas.




                                                Page No: 20 of 21

  This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                    Cisco Systems, Inc. Company Confidential


Custom EMC Test Report No: EDCS - 789978




Appendix C:     Test Equipment/Software Used to perform the test

Equip #     Manufacturer        Model                     Description                                  Last Cal     Next Due

CIS040603   Agilent             E4440A                    Precision Spectrum Analyzer                  19-Aug-08    19-Aug-09

CIS020975   Micro-Coax          UFB311A-0-1344-520520     RF Coaxial Cable, to 18GHz, 134.4 in         6-Mar-09     6-Mar-10

CIS030559   Micro-Coax          UFB311A-1-0950-504504     RF Coaxial Cable, to 18GHz, 95 in            6-Mar-09     6-Mar-10

CIS036716   Cisco               RF Coaxial Cable-SMA      Radio Test Cable, SMA-SMA                    11-Dec-08    11-Dec-09

CIS002119   EMC Test Systems    3115                      Double Ridged Guide Horn Antenna             10-Jun-09    10-Jun-10

CIS035038   Micro-Tronics       BRC50703-02               Notch Filter, SB:5.150-5.350GHz, to 11GHz    13-Jul-09    13-Jul-10

CIS035605   Micro-Tronics       BRC50704-02               Notch Filter, SB:5.470-5.725GHz, to 12GHz    15-Jul-09    15-Jul-10

CIS031700   Micro-Tronics       BRC50705                  Notch Filter, SB:5.725-5.875GHz, to 12 GHz   8-Jun-09     8-Jun-10

CIS034972   Midwest Microwave   ATT-0640-20-29M-02        Attenuator, 20dB, DC-40GHz                   13-May-09    13-May-10

CIS005691   Miteq               NSP1800-25-S1             Broadband Preamplifier (1-18GHz)             9-Oct-08     9-Oct-09




                                                Page No: 21 of 21

  This document is uncontrolled. Please refer to the electronic copy within EDCS for the most up to date version.
                                    Cisco Systems, Inc. Company Confidential



Document Created: 2009-08-11 11:06:02
Document Modified: 2009-08-11 11:06:02

© 2024 FCC.report