LDK102045 Response

FCC ID: LDK102045

Cover Letter(s)

Download: PDF
FCCID_262245

              Electro Magnetic Interference Testing and Engineering
              Wireless Testing, Electrical Safety Testing,
              PCB Designs, and Hardware Design Engineering
              360 Herndon Parkway, Suite 1400, Herndon, VA 20170
              Tel: 703-689-0368, Fax: 703-689-2056


August 8, 2002

Joe Dichoso
Federal Communication Commission

Reference: LDK102045
Correspondence number: 23502
Applicant: Cisco Systems Inc.


1)       Users manual pg 6 5 for example shows access point configuration. EMC test setup
photos do not seem to match access point and/or device external photos. Please
clarify/correct/re test as necessary.

RESPONSE: The EUT sent as a separate application was tested as a standalone device in a
laptop. This configuration will typically be used in laptop PCMCIA configurations. In order to
demonstrate co-location, the only configuration in which the Osprey 5 GHz Transmitter and the
Venus 2.4 GHz antenna will be used is in the access point configuration displayed on page 6-5
of the user manual. In conclusion, we must have two configuration pictures, the 5.5 GHz
Osprey EUT in a laptop and the second in the access point. Please see the EMC radiated test
data with both the 2.4 GHz and 5.5 GHz in simultaneous active mode uploaded with this
correspondence.

2)     Antenna options are flipup=dipole, flipdown=patch. Sister filing EA465289 has radiated
EMC tests in actual final config. access point, while here radiated is done in laptop with
extender card. Need 5 GHz band radiated tests with device in access point.

RESPONSE: Please see the 5 GHz band radiated test data, uploaded with this correspondence.

3) FCC ID is wrong in op desc exhibit

RESPONSE: It appears that this number is correct, please verify once again.

4) EMC radiated test needed with both 2.4 and 5 GHz active, or was that done already?

RESPONSE: The data for the 2.4 GHz and 5 GHz was initially done individually. Attached is the
test result for both devices in the active mode.

5) Please explain the user installed compliance label scheme in users manual pg 6 6.

RESPONSE: The AP1200 is designed to be modular in nature. If the customer orders the access
point and 5 GHz radio at the same time, the unit will be properly labeled with the information
for the 5 GHz radio. If the customer has previously purchased a 2.4 GHz version of the access
point, and at a later date orders the 5 GHz radio module, labeling will be provided with the
radio module to be placed by the end user on the exterior of the access point following
installation of the module. This section explains this labeling procedure.


              Electro Magnetic Interference Testing and Engineering
              Wireless Testing, Electrical Safety Testing,
              PCB Designs, and Hardware Design Engineering
              360 Herndon Parkway, Suite 1400, Herndon, VA 20170
              Tel: 703-689-0368, Fax: 703-689-2056

6) Please confirm that antenna orientations for "wall mounted" MPE test is correct. Users
manual and op desc do not seem to clearly describe antenna orientations for each mounting
configuration.

RESPONSE: The photograph 3.2.2 correctly depicts the antenna orientations for wall-mounted
equipment. See the Quick Start Guide uploaded with this correspondence response for the
mounting instructions.

7) grant condition should state that RF exposure was evaluated for colocation with LDK102042

RESPONSE: Test Report includes statement "RF exposure was evaluated for co-location with 2.4
GHz, model #

8) users manual mentions quick start guide with antenna connection instructions. please
submit. include diagrams or photos of recommended antenna installations.

RESPONSE: Quick Start Guide with antenna connection instructions uploaded with the
correspondence response.

9) MPE Fig 3.1.1 matches Photo 3.2.1, but Fig 3.1.2 does not match Photo 3.2.2, and Fig 3.1.3
does not match Photo 3.2.3. Please explain, including description of normal installation
conditions.

RESPONSE: Fig 3.1.2 and Fig. 3.1.3 do not exactly match the pictures. The purpose of these
diagrams was to represent different possible configurations. The normal operation/installation
configurations are:

1) Wall Mount; Flip Up/Flip Down 5 GHz antenna, Flip Up/Flip Down 2.4 GHz dipole antenna
2) Ceiling Mount
3) Desktop

An evaluation was performed with respect to field strength and height. It was determined that
the field strength values determined above the EUT were the same as those below the ceiling
mounted position at the same distance from the EUT. Therefore, it was concluded that the
desktop and ceiling mounted position would yield the same results, data for the ceiling mount
antenna was not provided.

10) MPE equipment list shows two probes. was same probe (TYPE 9) used for all stand alone
and simultaneous tests? if no, why not? if not, do tests with only TYPE 8 give correct
comparison for simultaneous tests?

RESPONSE: We apologize for any misrepresentation. Only the Type 9 probe was used for the
stand alone and simultaneous tests.

11) MPE please submit probe calibration certificates including 2.4 and 5.25 GHz factors.

RESPONSE: Rhein Tech Laboratories has calibration certificate and calibration factors for the
probe at these frequencies.
These were uploaded with this correspondence.


               Electro Magnetic Interference Testing and Engineering
               Wireless Testing, Electrical Safety Testing,
               PCB Designs, and Hardware Design Engineering
               360 Herndon Parkway, Suite 1400, Herndon, VA 20170
               Tel: 703-689-0368, Fax: 703-689-2056

12) MPE what are units for data tables in section 5? Note low range from W&G Type 9
datasheet is 1.2 V/m or 3.2 mW/m^2.

Two types of units for MPE data in section 5 were used; power density measured in mW/cm2
and field strength in V/m. In the far-field region, measurements were taken in power density
mode and in the near-field region field strength measurements were taken. Since OET Bulletin
65C displays MPE limits for the investigated frequencies as power density limits only, for all
measurements made as field strength, calculation using far field approximation into power
density were made, this data is presented in the updated report. Furthermore, additional
justification with respects to validity of this calculation is presented in the updated report.

Some MPE data shown in the report are below the specified low range level of the
measurement probe; essentially noise floor values. Our decision was to state the actual probe
value instead of stating noise floor in the test data tables. In the updated report, the low level
range of the EMR-200 is stated.

13) MPE please confirm/demonstrate that probe responds correctly to device modulations.
Some modulations and amplitudes can cause diode probes to over or under estimate actual rms
field strength levels

To investigate the influence of signal modulation on the EMR-200 measurement results the
substitution method was chosen. Namely: measurement with a standard receiving horn
antenna/ Spectrum analyzer, and the EMR Isotropic measurement unit.           First set of
measurements was performed with the EUT transmitting in CW mode and 100% duty cycle
modulation mode to a receiving horn antenna connected to a Spectrum Analyzer (Model
8564E). This antenna (Electro-Metrics, Model RGA, 1-18GHz) and the EUT was placed 20 cm
away from each other and at a height of one meter. A second set of measurements was
performed with the EMR-200 measurement unit; its isotropic probe was placed on the same
position and height as the receiving antenna in the first measurement. All equipment with
exception of the Spectrum Analyzer was placed in the anechoic room.

Each set of measurements included the following steps:
   § Power 1 (or power density – for the EMR-200) was measured from the EUT set in un-
       modulated mode at 2.4 GHz
   § Power 2 (or power density) was measured from the EUT set in 11MBPS digital frequency
       modulation used in this device
   § Ratio of Power 1 to Power 2 (or the ratio of the power densities for the EMR-200) was
       calculated.
The results of the third steps for the two sets of measurements were compared.
See test data below in Table 1.
Note: Spectrum Analyzer settings was Rbw/Vbw = 1MHz


                Electro Magnetic Interference Testing and Engineering
                Wireless Testing, Electrical Safety Testing,
                PCB Designs, and Hardware Design Engineering
                360 Herndon Parkway, Suite 1400, Herndon, VA 20170
                Tel: 703-689-0368, Fax: 703-689-2056

                Table 1: Investigation of influence of modulation to the EMR-200:


                                          Spectrum Analyzer, dBm or mW
 Description of the test                                                       EMR-200, mW/cm2
                                               dBm             mW
 Measurement of the un-modulated signal          - 4.4               0.36308        0.0126
 Measurement of modulated signal                 - 5.5               0.28184        0.0102
 Ration of un-modulated signal to                                    1.28882        1.2353
 modulated signal

Comparison of the measurements performed with the Spectrum Analyzer and the probe
demonstrates that a difference of less than 5% exists. This is a proof that the EMR display unit
does not produce erroneous levels when modulated signals are present.

14) MPE please confirm/demonstrate that probe responds correctly to simultaneous 2.4 and
5.25 GHz signals. Multiple signals with some diode probes can over or under estimate actual
rms field strength levels

The probe was investigated to determine its response when multiple signals at the same or
different frequencies were present with the substitution method in an anechoic room. Two
signal sources were used: One was the EUT configured to transmit in the un-modulated mode,
and the second was a 5 GHz generated signal from a signal generator (HP, Model 83752A) and
transmitting horn (Electro-Metrics, Model 3115, 1-18GHz) configuration.        First set of
measurements was performed with the Spectrum Analyzer connected to the receiving horn
antenna (both, the analyzer and the antenna are described in question 13 of the FCC’s
response. The second set of measurements was made with the EMR-200, placed in the same
position and height as the receiving horn antenna configuration from the first set of
measurement. Then the results of two sets of measurements were compared. The test setups
photos are shown below. All other equipment except the Spectrum Analyzer was placed inside
the anechoic room. Note: Spectrum Analyzer settings was Rbw/Vbw = 1MHz including a span
that includes both signals set at 5 GHz. A 4 GHz measurement bandwidth was used in the
Power density measurement mode. For the EMR-200 measurements calibration factor of 1 for
both frequencies was used.


            Electro Magnetic Interference Testing and Engineering
            Wireless Testing, Electrical Safety Testing,
            PCB Designs, and Hardware Design Engineering
            360 Herndon Parkway, Suite 1400, Herndon, VA 20170
            Tel: 703-689-0368, Fax: 703-689-2056


Photo 1: Test setup for the measurements made with the Spectrum Analyzer




Photo 2: Test setup for the measurements made with the EMR-200


                Electro Magnetic Interference Testing and Engineering
                Wireless Testing, Electrical Safety Testing,
                PCB Designs, and Hardware Design Engineering
                360 Herndon Parkway, Suite 1400, Herndon, VA 20170
                Tel: 703-689-0368, Fax: 703-689-2056

Each set of measurements included the following steps:
   § Power measurements (or power density measurements – for the EMR) were made for
       the 2.4 GHz signal with the 5 GHz signal turned off.
   § Power measurements (or power density measurements – for the EMR) were made for
       the 5 GHz signal with the 2.4 GHz signal turned off.
   § Power measurements (or power density measurements – for the EMR) were made with
       the both signals turned on.
Results of these measurements are shown in Table 2.


Table 2: Investigation of the probe response to two signals

                                           Spectrum Analyzer, dBm or mW        EMR-200,
       Description of the test
                                               dBm              mW             mW/cm2
 Measurement of the 2.4 GHz signal               - 23.4              0.00457    0.00035
 Measurement of the 5 GHz signal                 - 24.2              0.00380    0.00029
 Measurement of both signals radiating           -20.7               0.00851    0.00060
 simultaneously.

Comparison of the measurements performed with the Spectrum Analyzer and the probe
demonstrates that when two simultaneous transmitting signals are present, they produce
power/power density equal to the sum of the two signals generated separately. This is a proof
that the EMR display unit does not produce erroneous levels when two simultaneous signals are
present.

15) MPE LDK102042 original grant has 110mW, for 13.5 dBi antenna gives 33.9 dBm EIRP.
Please justify reported value of 30.1 dBm in Table 2.2.1.

RESPONSE: The EIRP was measured on the test range. This method was chosen because we
did not have the cable loss associated with the cable. A 1m cable was used between the
antenna and the port, which typically has a loss of 1.5 - 2 dB at 2.4 GHz.

16) MPE section 4.2 6 minute and 30 minute time averaging does not apply for general
population mobile devices. Please clarify/explain/justify affect of these time averagings and
relation to device duty factors.

RESPONSE: The W&G EMR 200 Meter operating manual specifies an averaging time of 6
minutes; all documentation for this device refers to 6 minutes averaging times only on our
equipment. These 6 minutes measurements repeated 5 times over a 30-minute period were
averaged and reported as 30 minute averaging data in our results with the EUT configured to
transmit at 100% duty cycle. The worst-case position with respect to MPE data was
determined from the result of MPE measurement vs. azimuth with 6 minutes averaging time.
This position was chosen for the final measurements vs. height, which were taken with 30
minutes averaging time in the manner described above.

17) MPE W&G EMR 200 meter datasheet list 15-minute max averaging time. Explain/justify
30 minute averaging time mentioned in section 4.2.


               Electro Magnetic Interference Testing and Engineering
               Wireless Testing, Electrical Safety Testing,
               PCB Designs, and Hardware Design Engineering
               360 Herndon Parkway, Suite 1400, Herndon, VA 20170
               Tel: 703-689-0368, Fax: 703-689-2056

Averaging time:
The W&G EMR 200 Meter operating manual specifies an averaging time of 6 minutes; all
documentation for this device refers to 6 minutes averaging times only on our equipment.
Measurements were taken every 6 minutes over a period of 30 minutes with the EUT
configured to transmit at 100% duty cycle, hence the reference to 30 minutes averaging time in
our report. These 6 minutes measurements were averaged and they are shown in our test
results received with 30 min averaging time.

18) MPE section 4.2 three step test sequence with 6 minute averaging in azimuth scan
followed by 30 minute averaging for 2 meter height scan at max azimuth position. Does that
mean field strength was averaged across all positions in a 6-minute azimuth scan time?

RESPONSE: Yes, you are right (see responses to 16 and 17)

19) appendix F antenna specs are patterns for antennas only or with final installation of all in
access point?

RESPONSE: The 2.4 GHz antenna plots cover the antennas only. The Osprey antennas include
installation in the AP.

20) MPE Due to off center reference points, it is difficult to make conclusions about
simultaneous MPE at any particular 20 cm locations. It may be more useful to reference center
point and use perimeter/diagonal of EUT as start of 20cm spacing. After response to these
RTs, we may have more comments about procedures and results.

RESPONSE: At the beginning of the MPE measurement the EUT was rotated to determine the
angle of the highest directivity for each antenna, this was the basis for the choice of antenna
reference points. These reference points did not coincide with the center of the EUT, but
nonetheless, these points represent the reference points of the radiating structures. The RF
safe distance is always the distance from the radiating structures.

21) MPE 3/28/02 LDK102042 grant states Yagi is for outdoor fixed mount use at 2m+
spacing. Why was that tested here with desktop and wall mounted EUT configurations?

RESPONSE: It is possible that this can be utilized inside a building, such as a warehouse. Yagi's
are sometimes deployed indoors to supply coverage in long, narrow corridors.

22) users manual exposure statement a) OET65C does not have MPE evaluation procedures,
please revise; b) 20 cm and 30 cm are contradictory, please revise.

RESPONSE: A revised User Manual was uploaded with this correspondence response.

Sincerely,

Desmond A. Fraser




President