Rev2 Test report

FCC ID: LDK102040

Test Report

Download: PDF
FCCID_162718

                                    Engineering and Testing for EMC and Safety Compliance

                                  CLASS II PERMISSIVE CHANGE FOR A

                 DIRECT SEQUENCE SPREAD SPECTRUM TRANSMITTER

                                                            CISCO Systems Inc.
                                                           170 West Tasman Drive
                                                          San Jose, CA 95134-1706

                                                             Model: AIR-LMC350

                                                          FCC ID: LDK102040
                                                         CANADA: 2461391186A
STANDARDS REFERENCED FOR THIS REPORT
PART 2: 1999                   FREQUENCY ALLOCATIONS AND RADIO TREATY MATTERS; GENERAL RULES AND REGULATIONS
PART 15: 1999                  RADIO FREQUENCY DEVICES
FCC 97-114                     GUIDANCE ON MEASUREMENTS FOR DIRECT SEQUENCE SPREAD SPECTRUM SYSTEMS
ANSI C63.4-1992                STANDARD FORMAT MEASUREMENT/TECHNICAL REPORT PERSONAL COMPUTER AND PERIPHERALS
RSS-139; Issue 1 (Provisional) LICENSED RADIOCOMMUNICAITONS DEVICES IN THE BAND 2400-2483.5
RSS-102, Issue 1: 1999         EVALUATION PROCEDURE FOR MOBILE AND PORTABLE RADIO TRANSMITTERS


      FCC Rules Parts              Frequency Range                       EIRP (W)                       Freq. Tolerance               Emission Designator
           15.247               2412-2462 MHz                              0.465                  N/A
 Industry Canada Standards         Frequency Range                       EIRP (W)                       Freq. Tolerance               Emission Designator
          RSS-210               2412-2462 MHz                              0.465                  N/A


  REPORT PREPARED BY:
                                                   EMC Engineer: Daniel Baltzell
                                                 Technical Writer: Melissa Fleming

                                                 Document Number: 2001212 / QRTL01-202

                        No part of this report may be reproduced without the full written approval of Rhein Tech Laboratories, Inc.




                                           360 Herndon Parkway, Suite 1400
                                                 Herndon, VA 20170
                               Phone: 703-689-0368; Fax: 703-689-2056; Metro: 703-471-6441


                        360 Herndon Parkway
                        Suite 1400
                        Herndon, VA 20170
                        http://www.rheintech.com

                                                                 TABLE OF CONTENTS
1    INTRODUCTION .............................................................................................................................................. 3
    1.1      RELATED SUBMITTAL (S)/GRANT (S) .................................................................................................. 3
    1.2      CHANGE INFORMATION ................................................................................................................................. 3
    1.3      TEST METHODOLOGY ............................................................................................................................. 3
    1.4      TEST FACILITY .......................................................................................................................................... 3
    1.5      EMISSIONS EQUIPMENT LIST ................................................................................................................ 4
2    SYSTEM TEST CONFIGURATION............................................................................................................... 7
    2.1      JUSTIFICATION.......................................................................................................................................... 7
    2.2      EUT EXERCISE SOFTWARE .................................................................................................................... 7
    2.3      SPECIAL ACCESSORIES ........................................................................................................................... 7
    2.4      TEST SYSTEM DETAILS........................................................................................................................... 8
    2.5      CONFIGURATION OF TESTED SYSTEM ............................................................................................... 9
3    CONFORMANCE STATEMENT.................................................................................................................. 10

4    FIELD STRENGTH CALCULATION.......................................................................................................... 11

5    RADIATED EMISSIONS MEASUREMENTS............................................................................................. 12

6    EFFECTIVE ISOTROPIC RADIATED POWER MEASUREMENTS..................................................... 12

7    RADIATED SPURIOUS EMISSIONS .......................................................................................................... 13
          7.1.1 Radiated Emissions Harmonics/spurious (Channel 1; 2412 MHz) ........................................................... 13
          7.1.2 Radiated Emissions Harmonics/spurious (Channel 6; 2437 MHz) ........................................................... 13
          7.1.3 Radiated Emissions Harmonics/spurious (Channel 11; 2462 MHz).......................................................... 14
8    COMPLIANCE WITH THE RESTRICTED BAND EDGE ....................................................................... 15

9    BANDEDGE PLOTS ....................................................................................................................................... 16
    9.1      RADIATED MEASUREMENT PHOTOS............................................................................................................. 18
    9.2      ANTENNA PHOTOS ....................................................................................................................................... 20




Certification Report For: CISCO                                                                                                  Page 2
Document Number: 2001212


                  360 Herndon Parkway
                  Suite 1400
                  Herndon, VA 20170
                  http://www.rheintech.com




1     INTRODUCTION

The following Application for Class II permissive change for a Direct Sequence Spread Spectrum transmitter is prepared on
behalf of Cisco Systems Inc in accordance with the Federal Communications Commissions and Industry Canada Rules and
Regulations. The Equipment Under Test (EUT) was the PCMCIA card, FCC ID: LDK102040 and CANADA: 2461391186A.
The test results reported in this document relate only to the item that was tested.

All measurements contained in this Application were conducted in accordance with ANSI C63.4 Methods of Measurement of
Radio Noise Emissions, 1992, with Federal Communications Commissions Rules and Regulations Part 15.247, 1999, and with
Industry Canada RSS210 and RSS102. The instrumentation utilized for the measurements conforms to the ANSI C63.4
standard for EMI and Field Strength Instrumentation. Some accessories are used to increase sensitivity and prevent
overloading of the measuring instrument. These are explained in the appendix of this report. Calibration checks are performed
regularly on the instruments, and all accessories including the high pass filter, preamplifier and cables.

1.1    RELATED SUBMITTAL (S)/GRANT (S)

This is a Class II Permissive Change.

1.2    CHANGE INFORMATION

An antenna was added to this device.

1.3    TEST METHODOLOGY

Radiated testing was performed according to the procedures in ANSI C63.4 1992. Radiated testing was performed at an
antenna to EUT distance of 3 meters. Emissions above 1 GHz were video averaged.

1.4    TEST FACILITY

The open area test site measurement facility used to collect the radiated data is located on the parking lot of Rhein Tech
Laboratories, Inc. 360 Herndon Parkway, Suite 1400, Herndon, Virginia 20170. This site has been fully described in a report
dated March 3, 1994, submitted to and approved by the Federal Communication Commission to perform AC line conducted and
radiated emissions testing (ANSI C63.4 1992).




Certification Report For: CISCO                                                                  Page 3
Document Number: 2001212


                     360 Herndon Parkway
                     Suite 1400
                     Herndon, VA 20170
                     http://www.rheintech.com



1.5      EMISSIONS EQUIPMENT LIST

  RTL
                                                                                                                      Calibration
 Asset         Manufacturer             Model                             Part Type                  Serial Number
                                                                                                                       due date
Number
900969   Hewlett Packard       85650A               Quasi-Peak Adapter (30 Hz – 40 GHz)              2412A00414      03/23/01
900929   Hewlett Packard       85650A               Quasi-Peak Adapter (30 Hz – 40 GHz)              2811A01276      03/28/01
900901   Hewlett Packard       85650A               Quasi-Peak Adapter (30 Hz – 40 GHz)              3145A01599      11/02/01
900339   Hewlett Packard       85650A               Quasi-Peak Adapter (30 Hz – 40 GHz)              2521A00743      03/27/01
900042   Hewlett Packard       85650A               Quasi-Peak Adapter (30 Hz – 40 GHz)              2521A01032      11/05/01
900924   Amplifier Research    75A220               Amplifier (10 kHz – 220 MHz)                                     N/A
900933   Hewlett Packard       11975A               Power Amplifier (2 - 8 GHz)                      2304A00348      11/15/01
901067   Hewlett Packard       8903B                Audio Analyzer                                   2303A00307      06/28/01
901055   Hewlett Packard       8901A Opt. 002-003   Modulation Analyzer                              2545A04102      06/08/01
900718   Voltech               PM3000A              Power Analyzer                                   6836-002-10     11/08/01
900397   Associated Research, 6554SA                Electrical Safety Compliance Analyzer            940281          11/08/01
         Inc.
900926   Hewlett Packard       8753D                RF Vector Network Analyzer                       3410A09659      03/28/01
901089   Hewlett Packard       HP875ET              Transmission/Reflection Network Analyzer         US39170052      N/A
900968   Hewlett Packard       8567A                Spectrum Analyzer (10 kHz – 1.5 GHz)             2602A00160      03/23/01
900903   Hewlett Packard       8567A                Spectrum Analyzer (10 kHz – 1.5 GHz)             2841A00614      11/02/01
900897   Hewlett Packard       8567A                Spectrum Analyzer (10 kHz – 1.5 GHz)             2727A00535      11/08/01
900931   Hewlett Packard       8566B                Spectrum Analyzer (100 Hz – 22 GHz)              3138A07771      03/27/01
900912   Hewlett Packard       8568A                RF Spectrum Analyzer (100 Hz – 1.5 GHz)          2634A02704      08/02/01
900824   Hewlett Packard       8591E                RF Spectrum Analyzer (9 KHz – 1.8 GHz)           3710A06135      11/14/01
900724   ARA                   LPB-2520             Log Periodic / Biconical Antenna (25-1000 MHz)   1037            2/1/01
900725   ARA                   LPB-2520             Log Periodic / Biconical Antenna (25-1000 MHz)   1036            07/12/01
900967   A.H. Systems          TDS-206/535-1        Tuned Dipole set (30 – 1000 MHz)                 126, 128, 129, 12/15/00
                               through                                                               132
                               TDS-206/535-4
900154   Compliance Design     Roberts Dipole       Adjustable Elements Dipole antenna (30-1000MHz) N/A              7/26/01
900814   Electro-Metrics       RGA-60               Double Ridges Guide Antenna (1-18 GHz)           2310            2/26/01
900081   EMCO                  3146                 Log-Periodic Antenna (200-1000 MHz)              1850
900800   EMCO                  3301B                Active Monopole (Rod antenna) (30 Hz – 50 MHz) 9809-4071         05/02/01
900151   Rohde@                HFH@-Z2              Loop Antenna (9kHz-30 MHz)                       82825/019       05/26/01
         Schwarz
900791   Schaffner –Chase      CSL6112              Bilog antenna (30 MHz – 2GHz)                    2099            2/22/01
901053   Schaffner –Chase      CBL6112B             Bilog Chase antenna (200 MHz – 2 GHz)            2648            05/24/01
900060   Hewlett Packard       86634B               Auxiliary Section for External Pulse Modulator   1314A02913      11/08/01
901041   ACO Pacific           511E                 Sound Level Calibrator                           028751          In calibration
900970   Hewlett Packard       85662A               Spectrum Analyzer Display                        254211239       03/23/01
900930   Hewlett Packard       85662A               Spectrum Analyzer Display                        3144A20839      03/28/01
900911   Hewlett Packard       85662A               Spectrum Analyzer Display                        2542A12739      08/02/01
900902   Hewlett Packard       85662A               Spectrum Analyzer Display                        2848A17585      11/02/01
900896   Hewlett Packard       85662A               Spectrum Analyzer Display                        2816A16471      11/02/01
900914   Hewlett Packard       8546OA               RF Filter Section, (100 KHz to 6.5 GHz)          3330A00107      11/07/01
901057   Hewlett Packard       3336B                Synthesizer/Level Generator                      2514A02585      06/21/01
900059   Hewlett Packard       8660C                Signal Generator (9 KHz – 3200 MHz)              1947A02956      11/08/01
900960   Hewlett Packard       8444A                Tracking Generator (0.5 –1500MHz)                2325A07827      03/08/01
900917   Hewlett Packard       8648C                Synthesized. Signal Generator                    3537A01741      03/28/01
                                                    (9 KHz – 3200 MHz)
900821   Hewlett Packard       33120A               15 MHz Function / Arbitrary Waveform Generator   US36029992      11/14/01
900059   Hewlett Packard       8660C                Synthesized. Signal Generator                    1947A02956      11/08/01
Certification Report For: CISCO                                                                                  Page 4
Document Number: 2001212


                      360 Herndon Parkway
                      Suite 1400
                      Herndon, VA 20170
                      http://www.rheintech.com

  RTL
                                                                                                                  Calibration
 Asset         Manufacturer              Model                         Part Type                 Serial Number
                                                                                                                   due date
Number
                                                   (9 kHz –3200 MHz)
900560   Haefely                PESD 1600          ESD Generator                                 H 703146        10/05/01
900099   Marconi                52022-910E         Signal Generator (10 kHz – 1 GHz)             119044-189      11/14/01
900195   Tektronix              CFG280             Function Generator (0.1 Hz – 11 MHz)          TW12167         N/A
900927   Tektronix              ASG 100            Audio Signal Generator                        B03274 V2.3     N/A
900935   Wavetek                3510B              Signal Generator                              5372160         03/28/00
900660   Philips                PM5418TDS          TV Generator                                  LO 604891       11/21/01
900369   Philips                PM5418TDS          TV Generator                                  LR81436C        N/A
900268   Taylor                 5565               Hygrometer / Thermometer                      N/A             09/05/01
901056   Hewlett Packard        8954A, Opt.H03     Transceiver Interface                         2924A00830      06/02/01
901088   Hewlett Packard        8954A              Transceiver Interface                         2146A00139      07/28/01
901082   AFJ International      AFJ LS16           LISN (9 kHz – 30 MHz)                         16010020081     06/16/01
901083   AFJ International      AFJ LS16           LISN (9 kHz – 30 MHz)                         16010020082     06/16/01
901084   AFJ International      AFJ LS16           LISN (9 kHz – 30 MHz)                         16010020080     06/16/01
901090   Bajog electronic       4V-100/200         LISN (150 kHz – 30 MHz)                       00-44-007       08/03/01
900726   Solar                  7225-1             LISN                                          N/A             03/29/01
900727   Solar                  7225-1             LISN                                          N/A             03/29/01
900078   Solar                  7225-1             LISN                                          N/A             03/29/01
900077   Solar                  7225-1             LISN                                          N/A             03/29/01
901054   Hewlett Packard        HP 3586B           Selective Level Meter                         1928A01892      06/08/01
900770   Hewlett Packard        437B               Power Meter                                   2949A02966      In cal.
900793   Hewlett Packard        432A               Thermistor Power Meter                        1848a22632      N/A
900126   Hewlett Packard        11970A             Harmonic Mixer (26-40 GHz)                    2332A01199      11/10/02
900396   Hewlett Packard        11970K             Harmonic Mixer (18-26 GHz)                    2332A00563      11/00/02
900921   Haefely                IP 6.2             Coupling Network                              083-334-13      11/10/01
900918   Voltech                IEC Standard 555   Reference Impedance Network (rented)          7701            11/08/01
900061   Hewlett Packard        86603A             RF Plug-in (1 to 2600 MHz)                    2221A02967      11/08/01
900160   Pacific                112-AMX            AC Power Source (rented)                      0187            11/15/01
900932   Hewlett Packard        8449B OPT H02      Preamplifier (1-26.5 GHz)                     3008A00505      09/15/01
900045   Hewlett Packard        8447F              Preamplifier                                  2944A03783      N/A
901040   Industrial             SMX100             Wide Band Preamplifier (0.01-1000 MHz)        1736-0696       11/17/01
900721   Hewlett Packard        8447D              Preamplifier (0.1-1300 MHz)                   2727A05397      N/A
900889   Hewlett Packard        85685A             RF Preselector for HP 8566B or 8568B (20Hz-   3146A01309      11/14/01
                                                   2GHz)
900566   Amplifier Research     FP 2000            Isotropic Field Probe                         20760           08/29/01
900174   FCC                    F-120-9A           RF Injection Probe (10 kHz – 300 MHz)         N/A             05/31/01
901044   FCC                    F-120-5            Bulk Current Injection Probe                  17              05/12/01
                                                   (10 kHz – 150 MHz)
901042   FCC                    F-72-1             RF Current Probe (10 Hz – 100 MHz)            44              05/11/01
900704   FCC                    F-14-1             Current Probe (10 Hz – 500 kHz)               33              05/12/01
900894   FCC                    F-33-1             RF Current Probe (10 kHz – 250 MHz)           303             05/30/01
900854   Solar Electronics Co   9119-IN            RF Current Probe                              972501
900849   Solar Electronics Co   9121-IN            Injection Probe (10 MHz – 1 GHz)              953501
900848   Solar Electronics Co   9320-IN            RF Current Probe                              990521
900913   Hewlett Packard        85462A             EMI Receiver RF Section (9 KHz – 6.5 GHz)     3325A00159      03/29/01
900769   Hewlett Packard        8481B              Power Sensor                                  2702A05059       In cal.
900937   Hewlett Packard        8482H              3-watt Power Sensor (100 KHz to 4.2 GHz)      3318A08961      12/02/01
900928   Hewlett Packard        83752A             Synthesized Sweeper, 0.01 to 20 GHz           3610A00866      03/28/01
900946   Tenney Engineering,    TH65               Temperature Chamber with Humidity             11380           11/07/01
         Inc.

Certification Report For: CISCO                                                                               Page 5
Document Number: 2001212


                      360 Herndon Parkway
                      Suite 1400
                      Herndon, VA 20170
                      http://www.rheintech.com

  RTL
                                                                                                           Calibration
 Asset          Manufacturer             Model                      Part Type             Serial Number
                                                                                                            due date
Number
900111   Omega Engineering      DP41-TC-DSS      Temperature Monitor                      2060123         In cal.
901043   FCC                                     Terminator for RF Current Probe F-72-1                   05/12/01
900731   Haefely                PEFT.1           Burst Tester with Coupling Network       082 106-29      11/10/01
900402   BAPCO Electro-Com      IEC 601 L        Safety Tester                            000028          11/10/01
900720   Haefely                Psurge 4.1       Surge Tester                             083-342-02      11/10/01
900839   Bird                   43P              Peak Reading Wattmeter                   3110            11/10/01




Certification Report For: CISCO                                                                        Page 6
Document Number: 2001212


                 360 Herndon Parkway
                 Suite 1400
                 Herndon, VA 20170
                 http://www.rheintech.com



2      SYSTEM TEST CONFIGURATION

2.1     JUSTIFICATION

The EUT was tested in all three orthogonal planes in order to determine worst-case emission. Channel 1 at 2.412 GHz,
Channel 6 at 2.437 GHz and Channel 11 at 2.462 GHz were tested and investigated from 9kHz to 24GHz. All three channels
were investigated and tested. Data for all three channels are presented in this report.

To complete the configuration required by the FCC, the transmitter was tested in the notebook computer with the integral
antenna connected to the antenna port as it is intended to be used.

The worst-case data taken in this report represents the highest data rate at 11 MBPS. Data rates of 5.5MBPS, 2 MBPS and 1
MBPS were investigated and found to be in compliance.

2.2     EUT EXERCISE SOFTWARE

The EUT was provided with software, which provides for continuous transmission during testing. The carrier was also checked
to verify that the information was being transmitted.

2.3     SPECIAL ACCESSORIES

N/A.




Certification Report For: CISCO                                                                Page 7
Document Number: 2001212


                   360 Herndon Parkway
                   Suite 1400
                   Herndon, VA 20170
                   http://www.rheintech.com



2.4      TEST SYSTEM DETAILS

The FCC Identifiers for all equipment, plus descriptions of all cables used in the tested system (including inserted cards, which
have grants) are:

        PART           MANUFACTURER              MODEL           SERIAL NUMBER         FCC ID               CABLE             RTL
                                                                                                          DESCRIPTION         BAR
                                                                                                                             CODE
      NOTEBOOK             ITRONIX                IX250         ZZGEG1129ZZ5957    LNQUSA40064-       UNSHIELDED POWER       13537
      COMPUTER                                                                        M6-E             CORD WITH AC/DC
                                                                                                         CONVERTER
 WIRELESS LAN        CISCO SYSTEMS, INC.       AIR-LMC352         SPL051002YW        LDK102040               N/A             13540
 PCMCIA CARD
     (EUT)
19V AC ADAPTER        DELTA ELECTRONICS         ADP-60DB         NPD0037027994          DOC               UNSHIELDED         13538




Certification Report For: CISCO                                                                      Page 8
Document Number: 2001212


                 360 Herndon Parkway
                 Suite 1400
                 Herndon, VA 20170
                 http://www.rheintech.com



2.5    CONFIGURATION OF TESTED SYSTEM
                                                  Antenna


                                                   Internal CISCO
                                                   LAN PCMCIA
                                                   Card




                                            EUT




Certification Report For: CISCO                     Page 9
Document Number: 2001212


                    360 Herndon Parkway
                    Suite 1400
                    Herndon, VA 20170
                    http://www.rheintech.com



  3    CONFORMANCE STATEMENT


STANDARDS REFERENCED FOR THIS REPORT
PART 2: 1999                   FREQUENCY ALLOCATIONS AND RADIO TREATY MATTERS; GENERAL RULES AND REGULATIONS
PART 15: 1999                  RADIO FREQUENCY DEVICES
FCC 97-114                     GUIDANCE ON MEASUREMENTS FOR DIRECT SEQUENCE SPREAD SPECTRUM SYSTEMS
ANSI C63.4-1992                STANDARD FORMAT MEASUREMENT/TECHNICAL REPORT PERSONAL COMPUTER AND PERIPHERALS
RSS-139; Issue 1 (Provisional) LICENSED RADIOCOMMUNICAITONS DEVICES IN THE BAND 2400-2483.5
RSS-102, Issue 1: 1999         EVALUATION PROCEDURE FOR MOBILE AND PORTABLE RADIO TRANSMITTERS

      FCC Rules Parts             Frequency Range                   EIRP                      Freq. Tolerance           Emission Designator
           15.247              2412-2462 MHz                        0.465               N/A
 Industry Canada Standards        Frequency Range                   EIRP                      Freq. Tolerance           Emission Designator
          RSS-210              2412-2462 MHz                        0.465               N/A

  I, the undersigned, hereby declare that the equipment tested and referenced in this report conforms to the identified standard(s)
  as described above. Modifications were not made during testing to the equipment in order to achieve compliance with these
  standards.

  Furthermore, there was no deviation from, additions to or exclusions from the ANSI C63.4 test methodology.


  EMC Engineer: Daniel Baltzell                                             Date: July 18, 2001


  Signature:


  Supervising Engineer: Desmond A. Fraser                                   Date: July 18, 2001

  Position: President                                           (NVLAP Signatory)

  Signature:


                    Accredited by the National Voluntary Accreditation Program for the specific scope of accreditation under Lab Code 20061-0.

  Note: This report may not be used by the client to claim product endorsement by NVLAP or any agency of the U.S.
  Government.




  Certification Report For: CISCO                                                                           Page 10
  Document Number: 2001212


                  360 Herndon Parkway
                  Suite 1400
                  Herndon, VA 20170
                  http://www.rheintech.com



4    FIELD STRENGTH CALCULATION
The field strength is calculated by adding the Antenna Factor and Cable Factor, and subtracting the Amplifier Gain (if any) from
the measured reading. The basic equation with a sample calculation is as follows:



                                                   FI(dBuV/m) = SAR(dBuV) + SCF(dB/m)
                                                           FI = Field Intensity
                                                     SAR = Spectrum Analyzer Reading
                                                        SCF = Site Correction Factor


The Site Correction Factor (SCF) used in the above equation is determined empirically, and is expressed in the following
equation:

                                               SCF(dB/m) = - PG(dB) + AF(dB/m) + CL(dB)

                                                       SCF = Site Correction Factor
                                                        PG = Pre-amplifier Gain
                                                         AF = Antenna Factor
                                                           CL = Cable Loss


The field intensity in microvolts per meter can then be determined according to the following equation:

                                                  FI(uV/m) = 10FI(dBuV/m)/20


For example, assume a signal at a frequency of 125 MHz has a received level measured as 49.3 dBuV. The total Site
Correction Factor (antenna factor plus cable loss minus preamplifier gain) for 125 MHz is
-11.5 dB/m. The actual radiated field strength is calculated as follows:

                                                   49.3 dBuV - 11.5 dB/m = 37.8 dBuV/m
                                                           37.8/20          1.89
                                                      10             = 10          = 77.6 uV/m


 EIRP calculation: Power from power meter in (dBm) + antenna gain in (dBi)




Certification Report For: CISCO                                                                     Page 11
Document Number: 2001212


                  360 Herndon Parkway
                  Suite 1400
                  Herndon, VA 20170
                  http://www.rheintech.com




5   RADIATED EMISSIONS MEASUREMENTS
 Before final measurements of radiated emissions were made on the open-field three/ten meter range; the EUT was scanned
 indoor at one and three meter distances. This was done in order to determine its emissions spectrum signature. The physical
 arrangement of the test system and associated cabling was varied in order to determine the effect on the EUT's emissions in
 amplitude, direction and frequency. This process was repeated during final radiated emissions measurements on the open-field
 range, at each frequency, in order to insure that maximum emission amplitudes were attained.

 Final radiated emissions measurements were made on the three/ten-meter, open-field test site. The EUT was placed on a
 nonconductive turntable 0.8 meters above the ground plane.

 At each frequency, the EUT was rotated 360 degrees, and the antenna was raised and lowered from one to four meters in order to
 determine the maximum emission levels. Measurements were taken using both horizontal and vertical antenna polarizations. .
 No video filter less than 10 times the resolution bandwidth was used. The range of the frequency spectrum to be investigated is
 specified in FCC Part 15. The highest emission amplitudes relative to the appropriate limit were measured and recorded in this
 report. For radiated measurements above 1 GHz, a resolution bandwidth of 1 MHz and a video bandwidth of 10 Hz are used.

 Note: Rhein Tech Laboratories, Inc. has implemented procedures to minimize errors that occur from test instruments, calibration,
 procedures, and test setups. Test instrument and calibration errors are documented from the manufacturer or calibration lab.
 Other errors have been defined and calculated within the Rhein Tech quality manual, section 6.1. Rhein Tech implements the
 following procedures to minimize errors that may occur: yearly as well as daily calibration methods, technician training, and
 emphasis to employees on avoiding error.

6   EFFECTIVE ISOTROPIC RADIATED POWER MEASUREMENTS

THE CALCULATION OF THE EIRP IS:

WATT = (V/M X 3)2 / 30

THE ELECTRIC FIELD STRENGTH OF CHANNELS 1, 6, AND 11 WERE TAKEN PEAK WITH A RESOLUTION BANDWITH OF 1 MHZ
AND VIDEO BANDWITH OF 1 MHZ AND FOUND AS FOLLOWS:

                                               Peak                        Site
        Frequency                            Analyzer                   Correction                    Corrected Level
          (MHz)                              Reading                     Factor                         (dBµV/m)
                                              (dBµV)                     (dB/m)
           2412                                78.7                       32.1                             110.8
           2437                                78.5                       32.0                             110.5
           2462                                78.8                       32.3                             111.1




Certification Report For: CISCO                                                                  Page 12
Document Number: 2001212


                  360 Herndon Parkway
                  Suite 1400
                  Herndon, VA 20170
                  http://www.rheintech.com



7   RADIATED SPURIOUS EMISSIONS
Radiated Spurious Emissions applies to harmonics and spurious emissions that fall in the restricted. The restricted bands are
listed in Section 15.205. The maximum permitted average field strength for the restricted band is listed in Section 15.209.

The test was performed at 1 MHz RBW and 10 Hz( average measurement ) and at 1 MHz RBW and 1 MHz (peak
measurement ).

7.1.1    Radiated Emissions Harmonics/spurious (Channel 1; 2412 MHz)


                                Peak         Average       Site
                                                                    Corrected
              Frequency       Analyzer       Analyzer   Correction                    Limit           Margin
                                                                      Level
                (MHz)         Reading        Reading     Factor                     (dBµV/m)           (dB)
                                                                   (dBµV/m)
                               (dBµV)         (dBµV)     (dB/m)
              2038.475          27.2           23.2       30.6        53.8            88.4          -34.6
              2412.000        101.67           94.2       14.2       108.4                       Fundamental
              2443.480          28.3           27.5       33.2        60.7            88.4          -27.7
              4824.000          16.2           11.3       30.3        41.6            54.0          -12.4
              7236.000           NF
              9648.000           NF
              12060.000          NF
              14472.000          NF
              16884.000          NF
              19296.000          NF
              21708.000          NF
              24120.000          NF

7.1.2    Radiated Emissions Harmonics/spurious (Channel 6; 2437 MHz)
                                Peak         Average       Site
                                                                    Corrected
              Frequency       Analyzer       Analyzer   Correction                    Limit           Margin
                                                                      Level
                (MHz)         Reading        Reading     Factor                     (dBµV/m)           (dB)
                                                                   (dBµV/m)
                               (dBµV)         (dBµV)     (dB/m)
              2063.474          27.4           23.2       30.6        53.8            89.0          -35.2
              2437.000         102.5           94.8       14.2       109.0                       Fundamental
              2518.968          29.5           24.7       33.2        57.9            89.0          -31.1
              4874.000          16.5           11.3       30.3        41.6            54.0          -12.4
              7311.000           NF
              9748.000           NF
              12185.000          NF
              14622.000          NF
              17059.000          NF
              19496.000          NF
              21933.000          NF
              24370.000          NF




Certification Report For: CISCO                                                                   Page 13
Document Number: 2001212


                   360 Herndon Parkway
                   Suite 1400
                   Herndon, VA 20170
                   http://www.rheintech.com


7.1.3    Radiated Emissions Harmonics/spurious (Channel 11; 2462 MHz)
                                 Peak         Average       Site
                                                                     Corrected
             Frequency         Analyzer       Analyzer   Correction                Limit      Margin
                                                                       Level
               (MHz)           Reading        Reading     Factor                 (dBµV/m)      (dB)
                                                                    (dBµV/m)
                                (dBµV)         (dBµV)     (dB/m)
             2088.473            24.3           20.3       30.6        50.9       86.9         -36.0
             2462.000           100.2           92.7       14.2       106.9                 Fundamental
             2585.966            19.2           15.0       33.2        48.2       86.9         -38.7
             4924.000            24.6           22.7       30.3        53.0       54.0          -1.0
             7386.000             NF
             9848.000             NF
             12310.000            NF
             14772.000            NF
             17234.000            NF
             19696.000            NF
             22158.000            NF
             24620.000            NF

NF = noise floor



TEST PERSONNEL:


Typed/Printed Name: Daniel Baltzell                                 Date: July 18, 2001


Signature:




Certification Report For: CISCO                                                             Page 14
Document Number: 2001212


                 360 Herndon Parkway
                 Suite 1400
                 Herndon, VA 20170
                 http://www.rheintech.com




8   COMPLIANCE WITH THE RESTRICTED BAND EDGE
Compliance with the band edges was performed using the procedure described in FCC’s Direct Sequence Spread Spectrum
Document. The final data derived below were from radiated measurements only. The data taken in this report represents the
worst case at 11 MBPS. Data rates of 5.5MBPS, 2 MBPS and 1 MBPS were investigated and found to be in compliance.

Channel       Frequency           Detector   Field Strength        Delta      Corrected       FCC Limit         FCC
 Set to       tested MHz                          Level           Factor         Field           µV/m)
                                                                                              (dBµ             Margin
                                                   µV/m)
                                                (dBµ               (dB)        Strength                         (dB)
                                                                              (dBµµV/m)
    1           2390.0              AV            108.4            60.9          47.5            54.0            -6.5
                                    PK            118.9
    11          2483.5              AV            106.9            56.0          50.9            54.0            -3.1
                                    PK            114.4




Certification Report For: CISCO                                                              Page 15
Document Number: 2001212


                 360 Herndon Parkway
                 Suite 1400
                 Herndon, VA 20170
                 http://www.rheintech.com




9   BANDEDGE PLOTS

                                                  CHANNEL 1




                                            LOWER BAND EDGE (∆ 60.9 DB)




Certification Report For: CISCO                                           Page 16
Document Number: 2001212


                 360 Herndon Parkway
                 Suite 1400
                 Herndon, VA 20170
                 http://www.rheintech.com




                                                   CHANNEL 11




                                            UPPER BAND EDGE (∆ 56.0 DB)




Certification Report For: CISCO                                           Page 17
Document Number: 2001212



Document Created: 2001-08-02 08:24:00
Document Modified: 2001-08-02 08:24:00

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC