RF exposure data

FCC ID: LDK102039

RF Exposure Info

Download: PDF
FCCID_99057

Test report #20000282F                      FCC 15.231 for MI-4800B              FCC ID: LDK102039
                                             Tested February 2, 2000


EXHIBIT M: RF EXPOSURE INFORMATION
[15.247(B4),1.307(B1),2.1093(C,D)]




                                           Engineering Analysis of

                              Direct Sequence Spread Spectrum Transceiver
                                            Model MI4800B

                                            FCC ID: LDK102039


                                                        To

                                   Federal Communications Commission

                             Part 1.1310 Radio Frequency Exposure Limits,

                         Part 2.1093 RF Exposure Evaluation: Portable Devices,

                                                        &

                                            OET 65 Supplement C


                                                    05/03/00




AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (616) 424-7014                                  99057
                                             Exhibit M: Page 1 of 2


Test report #20000282F                      FCC 15.231 for MI-4800B         FCC ID: LDK102039
                                             Tested February 2, 2000


This analysis was done per the requirements of Part 15.247(b4) of the FCC rules as part of the
FCC certification requirements for spread spectrum devices.

The Aironet radio modules are designed for a maximum transmit output power of 100mW
(+20dBm) and all calculations were based on that power . The test sample evaluated measured a
transmit output power of approximately 18dBm.

The unit is designed as a portable hand-held transmitter. This device will be utilized in the
general population / uncontrolled areas.

This category of devices are evaluated with respect to SAR limits for RF exposure. The
applicable limit is 1.6W/Kg as averaged over any one gram of cube tissue. This limit is the
‘partial-body’ limit for uncontrolled exposure areas.

A sample unit of model MI-4800B was sent to the University of Utah for SAR evaluation. This
evaluation took place under the direction of professor Dr. Om Gandhi.

The results of this SAR evaluation are:

        at +15dBm the SAR is .047W/Kg
        at +18dBm the SAR is .162W/Kg

Dr. Gandhi’s report can be sent when it is available.




AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (616) 424-7014                              99057
                                             Exhibit M: Page 2 of 2



Document Created: 2000-05-05 15:32:40
Document Modified: 2000-05-05 15:32:40