                         Device: IR529 915MHz WPAN IP67 Range Extender
                                          Single Antenna
                                     Model: IR529WP-915S/K9




                                            Report No.: 96154-22



                                        Date of issue: December 1, 2014


PREPARED FOR:                                           PREPARED BY:
Cisco Systems, Inc.                                     Eddie Mariscal
170 W. Tasman Dr.                                       CKC Laboratories, Inc.
San Jose, CA 95134-1706                                 5046 Sierra Pines Drive
                                                        Mariposa, CA 95338

The test data contained in this report documents the observed testing parameters pertaining to and are
relevant for only the sample equipment tested in the agreed upon operational mode(s) and
configuration(s) as identified herein. Compliance assessment remains the client’s responsibility. This
report may not be used to claim product endorsement by A2LA or any government agencies. This test
report has been authorized for release under quality control from CKC Laboratories, Inc.




                                                   Steve Behm
                              Director of Quality Assurance & Engineering Services
                                             CKC Laboratories, Inc.




                                                  Page 1 of 8
                                              Report No: 96154-22


Purpose:

To demonstrate compliance with United States, Canada and/or European Union RF Exposure
requirements for Portable equipment (devices used ≤20cm from the body) or Mobile equipment
(devices used >20cm from the body) with power output below exemption levels and Mobile equipment,
where Maximum Permissible Exposure (MPE) Calculations apply.

United States Compliance Requirements (1.1310):

                                   RF Exposure Evaluation Limits
                                 Occupational / Controlled Exposure
Frequency Range      Electric Field       Magnetic Field        Power Density       Averaging Time
(MHz)                Strength (V/m)       Strength (A/m)        (mW/cm2)            (minutes)
0.3-3.0              614                  1.63                  *(100)              6
3.0-30               1842/f               4.89/f                *(900/f2)           6
30-300               61.4                 0.163                 1                   6
300-1500             ---                  ---                   f/300               6
1500-100,000         ---                  ---                   5.0                 6

                                    RF Exposure Evaluation Limits
                              General Population / Uncontrolled Exposure
Frequency Range      Electric Field      Magnetic Field       Power Density         Averaging Time
(MHz)                Strength (V/m)      Strength (A/m)       (mW/cm2)              (minutes)
0.3-1.34             614                  1.63                  *(100)              30
1.34-30              824/f                2.19/f                *(180/f2)           30
30-300               27.5                 0.073                 0.2                 30
300-1500             ---                  ---                   f/1500              30
1500-100,000         ---                  ---                   1.0                 30

* Plane wave equivalent power density
Limit is calculated based on the mid-band frequency used in the operating frequency range.

Exemption Level: Power output <60/fGHz (mW)




                                              Page 2 of 8
                                          Report No: 96154-22


Canadian Compliance Requirements (RSS-102):

                                     RF Exposure Evaluation Limits
                                  Occupational / Controlled Exposure:
Frequency Range     Electric Field        Magnetic Field       Power Density   Averaging Time
(MHz)               Strength (V/m)        Strength (A/m)       (W/m2)          (minutes)
0.003-1.0           600                   4.9                   ---            6
1.0-10              600/f                 4.9/f                 ---            6
10-30               60                    4.9/f                 ---            6
30-300              60                    0.163                 10             6
300-1500            3.54 f0.5             0.0094*f0.5           f/3            6
1500-15,000         137                   0.364                 50             6
15,000-150,000      137                   0.364                 50             616000/f1.2

                                   RF Exposure Evaluation Limits
                             General Population / Uncontrolled Exposure
Frequency Range     Electric Field      Magnetic Field       Power Density     Averaging Time
(MHz)               Strength (V/m)      Strength (A/m)       (W/m2)            (minutes)
0.003-1.0            280                  2.19                  ---            6
1.0-10               280/f                2.19/f                ---            6
10-30                28                   2.19/f                ---            6
30-300               28                   0.073                 2              6
300-1500             1.585 * f0.5         0.0042 * f0.5         f/150          6
1500-15,000          61.4                 0.163                 10             6
15,000-150,000       61.4                 0.163                 10             616000/f1.2
*Power density limit applicable >100MHz


Exemption Level:

                          Maximum Output Power
Frequency Range (MHz)
                          (Conducted or EIRP)
      0.003-1000                   ≤ 200 mW
      1000-2200                    ≤ 100 mW
      2200-3000                     ≤ 20 mW
      3000-6000                     ≤ 10 mW




                                              Page 3 of 8
                                          Report No: 96154-22


European Union Compliance Requirements (ICNIRP):

                                         RF Exposure Evaluation Limits
                                      Occupational / Controlled Exposure:
Frequency Range         Electric Field        Magnetic Field       Power Density   Averaging Time
(MHz)                   Strength (V/m)        Strength (A/m)       (W/m2)          (minutes)
0.00082-0.065           610                 24.4                  ---              6
0.065-1.0               610                 1.6/f                 ---
1.0-10                  610/f               1.6/f                 ---              6
10-400                  61                  0.16                  10               6
400-2000                3.0 * f0.5          0.008 * f0.5          f/40             6
2000-300,000            137                 0.36                  50               6

                                       RF Exposure Evaluation Limits
                                 General Population / Uncontrolled Exposure
Frequency Range         Electric Field      Magnetic Field       Power Density     Averaging Time
(MHz)                   Strength (V/m)      Strength (A/m)       (W/m2)            (minutes)
0.003-0.150          87                     5.0                   ---              6
0.150-1.0            87                     0.73/f                --               6
1.0-10               87/f0.5                0.73/f                ---              6
10-400               28                     0.073                 2                6
400-2000             1.375 f0.5             0.0037*f0.5           f/200            6
2000-300,000         61                     0.16                  10               6
*Power density limit applicable >100MHz


Exemption Level: Power output < 20mW1




1
    May vary by product type
                                                Page 4 of 8
                                            Report No: 96154-22


Device and Antenna Operating Configuration:

     Device is operating at maximum output power with continuous transmission of
     modulated data. EUT employs removable antennas so data was gathered via
     conducted measurements. The manufacturer declares that the gain of the
     antenna used with the EUT will not exceed 5dBi.

     The manufacturer declares that the maximum transmit duty cycle of the EUTs
     listed above is 50%; therefore the average power is the product of the duty cycle
     and the peak maximum power.

Test Procedure:

     This equipment is evaluated in accordance with the guidelines set forth in OET
     Guide 65 & ANSI C95.1 for the US and Health Canada Safety Code 6 & RSS 102
     for Canada.




                                          Page 5 of 8
                                      Report No: 96154-22


                                            MPE Calculations

Applicability:
                                      X           General Population / Uncontrolled Exposure
     Limit Used
                                                  Occupational / Controlled Exposure
                                      No          United States
     RF Exposure Exemption            No          Canada
                                      NC          Europe
NC: Not contracted

Equipment operational details:

                  Operating       Measured         Antenna
                                                              Antenna Type /       Duty           EIRP
      Config #    Frequency      Output Power       Gain
                                                               Configuration       Cycle         (dBm)
                    (MHz)           (dBm)           (dBi)
         1          927.6            29.9             5        External Omni-      50.0%         34.9
                                                                stick Antenna

       Measurements based on EMC Test Reports: 96154-8 and 96154-11

MPE Calculation:
                               EIRP * DutyCycle
             Power Density                           Given: EIRP in mW or W and d in cm or m
                                    4d 2

                                       US (1.1310)                          Canada (RSS-102)
      Config #    Distance     Power Density       Limit           Power Density      Limit (W/m2)
                                        2
                    (cm)         (mW/cm )       (mW/cm2)                   2
                                                                      (W/m )
         1           20             0.31             0.61              3.07                6.1




                                                 Page 6 of 8
                                             Report No: 96154-22


Summary:

Exemptions:
In the case the equipment meets compliance requirements by exemption the product is approved for
use under mobile or portable conditions without further testing under the condition that any additional
collocation or simultaneous transmission requirements (including necessary separation distances) have
been met.

MPE Calculation Results:

In the case the equipment meets compliance by MPE Calculations the product is approved for use under
mobile conditions without further testing under the condition that any additional collocation or
simultaneous transmission requirements (including necessary separation distances) have been met. It is
assumed that the manufacturer shall design the equipment such that the minimum separation distance
of 20cm (or greater, as listed above) is met or that the manufacturer provides a protection guide (or
installation instructions) to the end user such that the antenna(s) may be installed in accordance with
the manufacturer’s instructions in such a manor to maintain the minimum separation distance.

The Absorption and distribution of Electromagnetic energy in the body is a very complex phenomena
that depends on the mass, shape and physiological condition of the body; the orientation of the body
with respect to the fields; and, the electrical properties of the body and the environment. Variables that
may play a substantial role in possible biological effects are those that characterize the environment
(including but not limited to: ambient temperature, air velocity, relative humidity and body insulation);
and those that characterize the individual (including but not limited to: age, gender, activity level and
existing debilitation or disease). Because innumerable factors may interact to determine specific
biological effects of exposure to electromagnetic fields, any protection guide should consider both
intended and unintended operational environments and provide guidance for installation and use of the
product such that proper separation distances can be maintained. (ANSI C95.1)




                                               Page 7 of 8
                                           Report No: 96154-22


References

Federal Communications Commission Knowledge Database (KDB) Publication 447498, “What are the RF exposure
         requirements and procedures for mobile and portable devices?” As in effect on the issue date of this
         report.
Federal Communications Commission Bulletin OET 65 Supplement C, “Evaluating Compliance with FCC Guidelines
         for Human Exposure to Radiofrequency Electromagnetic Fields” June 2001
Title 47 Code of Federal Regulations, Part 1.1310, “Radiofrequency radiation exposure limits.” As in effect on the
          issue date of this report.
Title 47 Code of Federal Regulations, Part 2.1091, “Radiofrequency radiation exposure evaluation: mobile devices.”
          As in effect on the issue date of this report.


Health Canada Safety Code 6 Limits of Human Exposure to Radiofrequency Electromagnetic Energy in the
        Frequency Range from 3 kHz to 300 GHz, 2009
Health Canada Safety Code 6 Technical Guide, 2009
Industry Canada RSS-102 Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All
         Frequency Bands) Issue 4, March 2010 (including update December, 2010)


International Commission on Non-Ionizing Radiation Protection. Guidelines for Limiting Exposure to Time-Varying
         Electric, Magnetic, and Electromagnetic Fields (up to 300 GHz). Health Physics 74 (4): 494-522; 1998.
International Commission on Non-Ionizing Radiation Protection Statement on the "Guidelines for limiting
         exposure to time-varying electric, magnetic and electromagnetic fields (up to 300 GHz). Health Physics
         97(3):257-259; 2009.
European Committee for Electrotechnical Standardization. European Normative, EN 62479 Assessment of the
       compliance of low power electronic and electrical equipment with the basic restrictions related to human
       exposure to electromagnetic fields (10 MHz to 300 GHz) 2002.




                                                   Page 8 of 8
                                               Report No: 96154-22



Document Created: 2015-01-05 13:17:07
Document Modified: 2015-01-05 13:17:07

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC