RF Exposure Info

FCC ID: LCGVU121

RF Exposure Info

Download: PDF
FCCID_4365567

                                                                                               Date
                                                                                               27-05-2019




To whom it may concern,
On behalf of our customer Endress+Hauser SE+Co. KG, we hereby declare the following
device:
FCC ID            : LCGVU121
IC                : 2519A-VU121
Brand             : Endress+Hauser
Model             : VU121


The EUT has one transmitter (BLE). The RF exposure assessment is based on the BLE
mode. The EUT is considered as ‘Mobile’ use.
The EUT has a maximum rated output power in BLE mode of 2.4 mW in the frequency
range of 2402 – 2480 MHz which means that the worst case prediction of power density
(100% reflection) at 20 cm distance (worst case) can be calculated as follows :
         EIRP
S=      4 * π * R2 (power density without reflection)

        22 * EIRP
S=      4 * π * R2 (power density with 100% reflection)

        22 * EIRP    EIRP (mW)            2.6 ___
S=      4 * π * R2 = π * (20cm)2     =   π * (20)2 = 0.0021 mW/cm2
(limit =10 W/m2 is 1.0 mW/cm2)



This means that the equipment is in compliance with FCC KDB Publication 447498,
47 C.F.R. §1.1310 and §2.1091 fulfils the requirements of RSS-102 Issue 5 Section 2.5.2.
stating: at or above 300 MHz and below 6 GHz and the source-based, time-averaged
maximum e.i.r.p. of the device is equal to or less than 1.31 x 10-2 ƒ 0.6834 W (adjusted for
tune-up tolerance), where ƒ is in MHz.
For this EUT the this calculates to: 1.31 x 10-2 (2402 0.6834) = 2.68 W.
The EUT’s maximum rate output power (EIRP) of 2.6 mW is within this requirement.
Note: For conservativeness, the lowest frequency is used for calculation.



Best regards,
TÜV Rheinland Nederland B.V.




R .van der Meer, Test Engineer



Document Created: 2019-05-27 15:25:32