TEST REPORT

FCC ID: L73EDFCCON

Test Report

Download: PDF
FCCID_1911077

             FCC Part 15 Subpart C Requirement
              Measurement and Test Report
                                        For
      Sanwa Electronic Instrument Co., Ltd
      1-2-50, Yoshida Honmachi, Higashi-Osaka, Osaka 578-0982, Japan


                              FCC ID: L73EDFCCON

                                February 26, 2013


This Report Concerns:                     Equipment Type:
     Original Report                      EDFC Active Control Unit


Test Engineer:        Daomen


Report Number:        SE13B-193F

Test Date:            February 20 to 23, 2013

Reviewed By:                            Karbon Y.Chung (Senior Manager)

Prepared By:          S&E Technologies Laboratory Ltd
                      Room 407, Block A Shennan Garden, Hi-Tech Industrial Park,
                      Shenzhen 518057, P.R. China.
                      Tel:   86-755-26636573, 26630631
                      Fax: 86-755-26630557



Note: This test report is limited to the above client company and the product model
      only. It may not be duplicated without prior written consent of S&E Technologies
      Laboratory Ltd.


Sanwa Electronic Instrument Co., Ltd                                                                                            FCC ID: L73EDFCCON


Table of Contents
1-TEST RESULT CERTIFICATION .................................................................................................... 3
2- EUT DESCRIPTION ....................................................................................................................... 4
3-TEST SYSTEM ................................................................................................................................ 5
  3.1 TEST MODE ................................................................................................................................................... 5
  3.2 TEST SETUP DIAGRAM .................................................................................................................................. 5
  3.3 BLOCK DIAGRAM OF EUT SYSTEM............................................................................................................... 5
  3.4 LIST OF CABLES ............................................................................................................................................ 5
4- TEST EQUIPMENT AND CALIBRATION ...................................................................................... 6
5- LABORATORY ACCREDITATIONS AND MEASUREMENT UNCERTAINTY ............................. 7
  5.1 LABORATORY ACCREDITATION ...................................................................................................................... 7
  5.2 MEASUREMENT UNCERTAINTY ..................................................................................................................... 7
6- TECHNICAL REQUIREMENTS AND RESULTS........................................................................... 8
  6.1 RADIATED EMISSION MEASUREMENT ........................................................................................................... 8




Report No.:SE13B-193F                                                    Page 2 of 13                                          FCC Part 15.249 Report


Sanwa Electronic Instrument Co., Ltd                                             FCC ID: L73EDFCCON



1- Test Result Certification
    Applicant:                     Sanwa Electronic Instrument Co., Ltd
                                   1-2-50, Yoshida Honmachi, Higashi-Osaka, Osaka
                                   578-0982, Japan
    Equipment Under Test:          EDFC Active Control Unit
    Trade Mark:                    EDFC

    Model Number.:                 EDC01-P7369
    Type of Modulation:            GFSK

    Operation Frequency:           2405MHz, 2424MHz, 2449MHz, 2479MHz

    Number of Channels:            4
    Antenna Designation:           Non-user replaceable (fixed)
    Power Supply:                  DC12.0V [ from a car battery]
    Date of Test:                  February 20 to 23, 2013



                                        Applicable Standards
                           Standard                                         Test Result

  FCC 47 CFR Part 15 Subpart C, §15.249                             No non-compliance noted



We hereby certify that:
The above equipment was tested at laboratory of Guangdong Galanz Enterprises Co., Ltd. The test
data, data evaluation, test procedures, and equipment configurations shown in this report were
made in accordance with the procedures given in ANSI C63.4-2003. The energy emitted by the
sample EUT tested as described in this report is in compliance with conducted and radiated
emission limits of FCC Rules Part 15C: 2007, §15.249.

The test results of this report relate only to the tested sample identified in this report.




Report No.:SE13B-193F                         Page 3 of 13                       FCC Part 15.249 Report


Sanwa Electronic Instrument Co., Ltd                                            FCC ID: L73EDFCCON


2- EUT Description

 Product Name:                      EDFC Active Control Unit

 Trade Mark:                        EDFC

 Model Number:                      EDC01-P7369

 Model Difference:                  N/A

 Type of Modulation::               GFSK

 Frequency Range:                   2405MHz, 2424MHz, 2449MHz, 2479MHz

 Number of Channels:                4

 Power Supply:                      12.0V DC supplied by regulated DC power supply

 Antenna Designation:               Non-user replaceable (fixed)

Remark: This submittal test report is intended for FCC ID: L73EDFCCON filing to comply with Section
15.249 of the FCC Part 15, Subpart C Rules.




Report No.:SE13B-193F                         Page 4 of 13                      FCC Part 15.249 Report


Sanwa Electronic Instrument Co., Ltd                                       FCC ID: L73EDFCCON


3-Test System
3.1 Test Mode

The compliance test was performed under test modes:
Mode 1: Transmitting at 2405MHz.
Mode 2: Transmitting at 2449MHz.
Mode 3: Transmitting at 2479MHz.
The EUT is designed both of horizontally placed and vertically placed. In radiated emission
measurement, each condition was conducted.
As a result, the below operation that produce the maximum emission were reported.
Radiated emission measurement --- Mode 1, Mode 2, Mode 3

3.2 Test Setup Diagram

. Radiated Emisison




3.3 Block Diagram of EUT System




3.4 List of Cables

    No     Cable Name     Shielded (Y/N)   Length (m)        Spec.             Remark

                                                          28AWG 80oC       For power supply
      1     AWM2464             Y              1.5
                                                             300V             and signal




Report No.:SE13B-193F                      Page 5 of 13                    FCC Part 15.249 Report


Sanwa Electronic Instrument Co., Ltd                                   FCC ID: L73EDFCCON


4- Test Equipment and Calibration

      Equipment type     Manufacturer        Model     Serial Number     Calibration Due

     Biconilog Antenna       ETS            3142C       00042672             2013/09

          Receiver       SCHAFFNER         SMR4503        11725              2013/07

     Spectrum Analyzer       R/S            FSP30         100755             2013/11

   Double-Ridged-Wave-
                             ETS             3115          6587              2013/08
    guide Horn Antenna

   Double-Ridged-Wave-
                             ETS             3160       00052486             2013/08
    guide Horn Antenna

          Amplifier        Agilent          83017A     MY39500438            2013/11

      Band-pass Filter   Micro-Tronic     BRM50702       S/N-030             2013/11

     DC Power Supply       Jiangbo          JB-305      A0412374             2013/10

     HF Loop Antenna       TESEQ           HLA6120        26348              2013/10

         Chamber             ETS              N/A          N/A               2013/05




Report No.:SE13B-193F                   Page 6 of 13                   FCC Part 15.249 Report


Sanwa Electronic Instrument Co., Ltd                                       FCC ID: L73EDFCCON



5- Laboratory Accreditations and Measurement Uncertainty
5.1 Laboratory Accreditation

FCC-Registration No.: 580210
Guangdong Galanz Enterprises Co., Ltd EMC Laboratory has been registered and fully
described in a report filed with the FCC (Federal Communications Commission). The acceptance
letter from the FCC is maintained in our files. Registration no. 580210, Listing date November 28,
2012.

5.2 Measurement Uncertainty

of+/-4.5dB for Radiated Emissions




Report No.:SE13B-193F                      Page 7 of 13                    FCC Part 15.249 Report


Sanwa Electronic Instrument Co., Ltd                                         FCC ID: L73EDFCCON


6- Technical Requirements and Results
6.1 Radiated Emission Measurement

Applicable Standard:

Fundamental and Harmonics Emission Limit

According to §15.249(a), the field strength of emissions from intentional radiators operated within
these frequency bands shall comply with the following:

Fundamental Frequency      Field Strength of Fundamental        Field Strength of Harmonics
MHz                        (mV/m @3m) (dBuV/m @3m)              (uV/m @3m) (dBuV/m @3m)

2400-2483.5                    50         94(Average)             500       54(Average)
                                          114(Peak)                         74(Peak)

General Radiated Emission Limit

According to §15.249(d),emissions radiated outside of the specified frequency bands, except for
harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the
general radiated emission limits in Section 15.209, whichever is the lesser attenuation.


Test Procedure:

1. The EUT was placed on a turn table which is 0.8m above ground plane.
2. The turn table shall rotate 360 degrees to determine the position of maximum emission level.
3. EUT is set 3m away from the receiving antenna which varied from 1m to 4m to find out the
   highest emissions.
4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
5. And also, each emission was to be maximized by changing the polarization of receiving
   antenna both horizontal and vertical.
6. Repeat above procedures until all frequency measurement were completed.
7. Emissions were investigated to the 10th harmonic of the fundamental frequency.

The field strength is calculated by adding the Antenna Factor and Cable Factor and subtracting
the Amplifier Gain and Duty Cycle Correction Factor(if any) from the measured reading. The
basic equation with a sample calculation is as follows:

FS = RA + AF + CL - AG

        Where FS = Field Strength              CL = Cable Attenuation Factor (Cable Loss)
         RA = Reading Amplitude                            AG = Amplifier Gain
           AF = Antenna Factor




Report No.:SE13B-193F                       Page 8 of 13                    FCC Part 15.249 Report


Sanwa Electronic Instrument Co., Ltd                     FCC ID: L73EDFCCON


Test Configuration between 9K and1 GHz:




                                                            Or   Loop
                                                                 antenna




Test Configuration above 1 GHz:




Test Results:

  Temperature:                    25oC
  Humidity:                       53%
  EUT Operation:                  Transmitting
  Test Date:                      February 23, 2013




Report No.:SE13B-193F                     Page 9 of 13   FCC Part 15.249 Report


Sanwa Electronic Instrument Co., Ltd                                            FCC ID: L73EDFCCON



Spurious Emission In the Frequency Rang 9KHz to 1GHz:

 Fc= 2405MHz Transmitting Operation

                            Detector                Ant./CL/      Actual
      Freq.      Ant.Pol.               Reading                              Limit 3m    Margin
                             Mode                   Amp.CF         FS
     (MHz)        (H/V)                 (dBuV)                              (dBuV/m)      (dB)
                            (PK/QP)                  (dB)       (dBuV/m)

     30.00          H          QP          4.3        16.7         21.0        40.0       -19.0
     100.68         H          QP         20.2         8.4         28.6        43.5       -14.9
     30.84          V          QP          3.6        16.8         20.4        40.0       -19.6
     100.56         V          QP         23.3         8.4         31.7        43.5       -11.8

 Fc= 2449MHz Transmitting Operation

                            Detector                Ant./CL/      Actual
      Freq.      Ant.Pol.               Reading                              Limit 3m    Margin
                             Mode                   Amp.CF         FS
     (MHz)        (H/V)                 (dBuV)                              (dBuV/m)      (dB)
                            (PK/QP)                  (dB)       (dBuV/m)

     30.00          H          QP          4.6        16.7         21.3        40.0       -18.7
     100.62         H          QP         19.8         8.4         28.2        43.5       -15.3
     30.78          V          QP          3.8        16.8         20.6        40.0       -19.4
     100.60         V          QP         24.7         8.4         33.1        43.5       -10.4

 Fc= 2479MHz Transmitting Operation

                            Detector                Ant./CL/      Actual
      Freq.      Ant.Pol.               Reading                              Limit 3m    Margin
                             Mode                   Amp.CF         FS
     (MHz)        (H/V)                 (dBuV)                              (dBuV/m)      (dB)
                            (PK/QP)                  (dB)       (dBuV/m)

     30.12          H          QP          4.1        16.7         20.8        40.0       -19.2
     100.74         H          QP         18.9         8.4         27.3        43.5       -16.2
     30.55          V          QP          4.4        16.8         21.2        40.0       -18.8
     100.52         V          QP         23.8         8.4         32.2        43.5       -11.3


 Note: For emission measurement, the compliance tests were performed both of horizontally placed
 and vertically placed in EUT (X position, Y position, Z position). As a result, the data of operation
 mode that produce the maximum emission were reported. The other emissions are more than 20dB
 below the limit or the field strength is too small to be measured.




Report No.:SE13B-193F                        Page 10 of 13                      FCC Part 15.249 Report


Sanwa Electronic Instrument Co., Ltd                                            FCC ID: L73EDFCCON



Spurious Emission In the Frequency Rang above 1GHz:

 Fc= 2405MHz Transmitting Operation

                            Detector                Ant./CL/      Actual
      Freq.      Ant.Pol.               Reading                              Limit 3m    Margin
                             Mode                   Amp.CF         FS
     (MHz)        (H/V)                 (dBuV)                              (dBuV/m)      (dB)
                            (PK/AV)                  (dB)       (dBuV/m)

    2405.00         H          PK        97.17        -2.61       94.56       114.00      -19.44
    2405.00         H          AV        64.68        -2.61       62.07       94.00       -31.93
    2400.00         H          PK        69.86        -2.61       67.25       74.00       -6.75
    2400.00         H          AV        34.04        -2.61       31.43       54.00       -22.57
    4812.00         H          PK        51.33        0.92        52.25.      74.00       -21.75
    4812.00         H          AV        29.76        0.92        30.68       54.00       -23.32
    2405.00         V          PK        93.92        -2.61       91.31       114.00      -22.69
    2405.00         V          AV        63.30        -2.61       60.69       94.00       -33.31
    2400.00         V          PK        66.61        -2.61       64.00       74.00       -10.00
    2400.00         V          AV        33.52        -2.61       30.91       54.00       -23.09
    4810.00         V          PK        51.10        0.92        52.02       74.00       -21.98
    4810.00         V          AV        29.58        0.92        30.50       54.00       -23.50

 Note: For emission measurement, the compliance tests were performed both of horizontally placed
 and vertically placed in EUT (X position, Y position, Z position). As a result, the data of operation
 mode that produce the maximum emission were reported. The other emissions are more than 20dB
 below the limit or the field strength is too small to be measured.




Report No.:SE13B-193F                        Page 11 of 13                      FCC Part 15.249 Report


Sanwa Electronic Instrument Co., Ltd                                            FCC ID: L73EDFCCON



 Fc= 2449MHz Transmitting Operation

                            Detector                Ant./CL/      Actual
      Freq.      Ant.Pol.               Reading                              Limit 3m    Margin
                             Mode                   Amp.CF         FS
     (MHz)        (H/V)                 (dBuV)                              (dBuV/m)      (dB)
                            (PK/AV)                  (dB)       (dBuV/m)

    2449.00         H          PK        97.76        -2.10       95.66       114.00      -18.34
    2449.00         H          AV        66.35        -2.10       64.25       94.00       -29.75
    2483.50         H          PK        53.52        -1.86       51.66       74.00       -22.34
    2483.50         H          AV        32.70        -1.86       30.84       54.00       -23.16
    4902.00         H          PK        50.71        0.92        51.63       74.00       -22.37
    4902.00         H          AV        29.34        0.92        30.26       54.00       -23.74
    2449.00         V          PK        94.38        -2.10       92.28       114.00      -21.72
    2449.00         V          AV        64.30        -2.10       62.20       94.00       -31.80
    2483.50         V          PK        49.65        -1.86       47.79       74.00       -26.21
    2483.50         V          AV        30.01        -1.86       28.15       54.00       -25.85
    4900.00         V          PK        49.90        0.92        50.82       74.00       -23.18
    4900.00         V          AV        29.20        0.92        30.12       54.00       -23.88

 Note: For emission measurement, the compliance tests were performed both of horizontally placed
 and vertically placed in EUT (X position, Y position, Z position). As a result, the data of operation
 mode that produce the maximum emission were reported. The other emissions are more than 20dB
 below the limit or the field strength is too small to be measured.




Report No.:SE13B-193F                        Page 12 of 13                      FCC Part 15.249 Report


Sanwa Electronic Instrument Co., Ltd                                            FCC ID: L73EDFCCON



 Fc= 2479MHz Transmitting Operation

                            Detector                Ant./CL/      Actual
      Freq.      Ant.Pol.               Reading                              Limit 3m    Margin
                             Mode                   Amp.CF         FS
     (MHz)        (H/V)                 (dBuV)                              (dBuV/m)      (dB)
                            (PK/AV)                  (dB)       (dBuV/m)

    2479.00         H          PK        97.03        -1.90       95.13       114.00      -18.87
    2479.00         H          AV        64.75        -1.90       62.85       94.00       -31.15
    2483.50         H          PK        69.36        -1.86       67.50       74.00       -6.50
    2483.50         H          AV        37.77        -1.86       35.91       54.00       -18.09
    4958.00         H          PK        49.95        0.92        50.87       74.00       -23.13
    4958.00         H          AV        29.43        0.92        30.35       54.00       -23.65
    2479.00         V          PK        93.47        -1.90       91.57       114.00      -22.43
    2479.00         V          AV        62.67        -1.90       60.77       94.00       -33.23
    2483.50         V          PK        69.36        -1.86       65.47       74.00       -8.53
    2483.50         V          AV        36.33        -1.86       34.47       54.00       -19.53
    4958.00         V          PK        49.54        0.92        50.46       74.00       -23.54
    4958.00         V          AV        29.32        0.92        30.24       54.00       -23.76


 Note: For emission measurement, the compliance tests were performed both of horizontally placed
 and vertically placed in EUT (X position, Y position, Z position). As a result, the data of operation
 mode that produce the maximum emission were reported. The other emissions are more than 20dB
 below the limit or the field strength is too small to be measured.




Report No.:SE13B-193F                        Page 13 of 13                      FCC Part 15.249 Report



Document Created: 2013-03-02 17:00:08
Document Modified: 2013-03-02 17:00:08

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC