Test report

FCC ID: L2V-PT2

Test Report

Download: PDF
FCCID_1171139

                                            Test Report
                                                   for

                                              Model: PT2

                                            FCC ID: L2V-PT2

                                                    to

                                Federal Communications Commission

                                           Rule Part(s) Part 25

                                    Date of report: August 11, 2009

At the Request of:                Axonn, LLC
                                  19349 N. 12th Street
                                  Covington, LA 70433

Attention of:                     Christopher Robinson
                                  Ph: 985-893-1048
                                  Fax: 985-893-1858
                                  Email: ChrisR@axonn.com




Supervised by:                                                    John Erhard: Engineering Manager




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                               p0960008, d0980014 Rev 4.0


                                  Test Report Revision History
        Revision   Date                    Revised By   Reason for revision
        1.0        August 11, 2009         J Erhard     Original Document
        2.0        August 28, 2009         K Springer   Edit Model Number
                                                        Updated table to include EIRP power
        3.0        September 11, 2009      J Erhard
        4.0        September 15, 2009      J Erhard     Add Radiated Spurious emissions data




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                         p0960008, d0980014 Rev 4.0


                              Testimonial And Statement Of Verification


This is to certify that:


        1.       That the application was prepared either by, or under the direct supervision of, the undersigned.

        2.       That the technical data supplied with the application was taken under my direction and
                 supervision.

        3.       That the data was obtained on representative units, randomly selected.

        4.       That, to the best of my knowledge and belief, the facts set forth in the application and
                 accompanying technical data are true and correct.




Certifying Engineer:                                                John Erhard: Engineering Manager




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                                  p0960008, d0980014 Rev 4.0


                                           Table of Contents

Rule                  Description                                                                 Page

                      Test Report                                                                    2

                      Standard Test Conditions and Engineering Practices                             3

                      List of General Technical Information                                          4

25.204                Power limits (conducted)                                                       5

25.204                Power limits (radiated)                                                        6

2.1053                Radiated Spurious Emissions                                                    7

25.202(f)             Emissions Limitations for Portable Earth Stations                              8

                      Occupied Bandwidth                                                            14

25.202(f)             Emission Masks                                                                16

25.216(g)(i)          Emissions Limits for Portable Earth Stations                                  18

25.202(d)             Frequency Tolerance                                                           20

                      Test Equipment Utilized                                                       21




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176
(866) 311-3268 phone, (480) 926-3598 fax                             p0960008, d0980014 Rev 4.0


Required information per ISO 17025-2005, paragraph 5.10.2:
a)                                            Test Report

b) Laboratory:                     Compliance Testing
 (FCC: 31040/SIT)                  3356 N. San Marcos Place, Suite 107
 (Canada: IC 2044-A)               Chandler, AZ 85225

c) Report Number:                  d0980014

d) Client:                         Axonn, LLC
                                   19349 N. 12th Street
                                   Covington, LA 70433

e) Identification:                 PT2

  EUT Description:                 Find Me - Satellite

f) EUT Condition:                  Not required unless specified in individual tests.

g) Report Date:                    August 11, 2009

h, j, k):                          As indicated in individual tests.

i) Sampling method:                No sampling procedure used.

l) Uncertainty:                    In accordance with CT internal quality manual.

m) Supervised by:




                                                                               John Erhard: Engineering Manager

n) Results:                        The results presented in this report relate only to the item tested.

o) Reproduction:                   This report must not be reproduced, except in full, without written permission
                                   from this laboratory.

Accessories used during testing:

       Type           Quantity            Manufacturer             Model             Serial No.           FCC ID




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                      Page 2 of 21
(866) 311-3268 phone, (480) 926-3598 fax                                            p0960008, d0980014 Rev 4.0


                      Standard Test Conditions and Engineering Practices
Except as noted herein, the following conditions and procedures were observed during the testing:

In accordance with ANSI C63.4-2003, section 6.1.9, and unless otherwise indicated in the specific measurement
results, the ambient temperature of the actual EUT was maintained within the range of 10 to 40C (50 to 104 F)
unless the particular equipment requirements specify testing over a different temperature range. Also, unless
otherwise indicated, the humidity levels were in the range of 10% to 90% relative humidity.

Prior to testing, the EUT was tuned up in accordance with the manufacturer's alignment procedures. All external
gain controls were maintained at the position of maximum and/or optimum gain throughout the testing.

Measurement results, unless otherwise noted, are worst-case measurements.

                                      Test and Measurement Data
All tests and measurement data shown were performed in accordance with FCC Rules and Regulations,
Volume II; Part 2 and the following individual Parts: FCC Part 25 Satellite Communications

                                                    A2LA
“A2LA has accredited Compliance Testing in Chandler, AZ for technical competence in the field of Electrical
testing. The accreditation covers the specific tests and types of tests listed on the agreed scope of
accreditation. This laboratory meets the requirements of ISO 17025:2005 ‘General Requirements for the
Competence of Testing and Calibration Laboratories’ and any additional program requirements in the
identified field of testing.”

Please refer to www.a2la.org for current scope of accreditation.

Certificate number: 2152.01




Industry Canada OATS Number 2011A-1

FCC OATS Reg. Number 933597




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                   Page 3 of 21
(866) 311-3268 phone, (480) 926-3598 fax                                         p0960008, d0980014 Rev 4.0


                                 List of General Technical Information
                  In Accordance with FCC Rules and Regulations Volume II, Part 2 and to Part 25

Name and Address of Applicant:        Axonn, LLC
                                      19349 N. 12th Street
                                      Covington, LA 70433

Manufacturer:                         Axonn, LLC
                                      19349 N. 12th Street
                                      Covington, LA 70433

Model Number:                         PT2

(c)(3):   Instruction Manual(s): Please see attached exhibits

(c)(4):   Type of Emission:            BPSK

(c)(5):   Frequency Range, MHz:                  1611.25 to 1618.75


(c)(6):   Power Rating, Watts:                   0.481
                       Switchable                     Variable               X    N/A




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                   Page 4 of 21
(866) 311-3268 phone, (480) 926-3598 fax                                         p0960008, d0980014 Rev 4.0


Name Of Test:                  Power Limits (conducted)
Specification:                 25.204                                    Engineer: J Erhard
Test Equipment Utilized        i00331                                    Test Date: 8/7/2009

                                             Test Procedure

The UUT was connected directly to a Spectrum analyzer. The RBW was set to 3 MHZ ensuring that the
complete power envelope from the 2 MHZ transmit signal was captured. The peak readings for the high and
low channel were taken and recorded.

                                               Test Setup


                                   UUT                          Spectrum
                                                                Analyzer


                                      Transmitter Peak Output Power



                            Tuned           Recorded        Calculated    Calculated
                          Frequency        Measurement         EIRP         EIRP
                             MHz             (dBm)            (dBm)        (Watts)
                           1611.25            26.82           23.52         0.225
                           1618.75            26.50           23.20         0.209




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                 Page 5 of 21
(866) 311-3268 phone, (480) 926-3598 fax                                       p0960008, d0980014 Rev 4.0


Name Of Test:                 Power Limits (radiated)
Specification:                25.204                              Engineer: J Erhard
Test Equipment Utilized       i00049, i00266, i00267              Test Date: 8/7/2009

                                            Test Procedure

The UUT was The UUT was placed on an OATS 3m from the receiving antenna and was tester per the TIA-
603 substitution method. The EIRP measurements are recorded in the table

                                              Test Setup


                    UUT                    Antenna              Spectrum
                                                                Analyzer


                                     Radiated Peak Output Power


                                    Tuned             EIRP    EIRP
                                  Frequency          (dBm)   (Watts)
                                     MHz
                                   1611.25           23.52    0.225
                                   1618.75           23.20    0.209




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                             Page 6 of 21
(866) 311-3268 phone, (480) 926-3598 fax                                   p0960008, d0980014 Rev 4.0


Name of Test:                    Radiated spurious Emissions
Specification:                   2.1053                                    Engineer: J. Erhard
Test Equipment Utilized          i00049, i00267                            Test Date: 9/15/2009

                                                Test Procedure

The UUT was tested in an Open Area Test Site (OATS) set 3m from the receiving antenna. A spectrum analyzer
was used to verify that the UUT met the requirements for Radiated Emissions. The UUT was tested by rotating it
360 with the antennas in both the vertical and horizontal orientation and raised from 1 to 4 meters to ensure the
                                                                               th
TX signal levels were maximized. All emissions from 30 MHz to the 10 harmonic of the highest tunable
frequency were examined.

                                                   Test Setup


                        UUT                    Antenna                  Spectrum
                                                                        Analyzer

Settings below 1 GHz
RBW = 3 KHz
VBW = 10KHz
Detector – average

Sample Calculations
Corrected Value = Measured Value + Correction factor
Correction factor = ACF + Cable loss


                                              Radiated Emissions

        Emission Freq    Measured Value      Correction Factor     Corrected Value       Limit     Result
           (MHz)            (dBm/m)                (dB)               (dBm/m)          (dBm/m)
           51.475             -90.0                 8.4                 -81.6             -13       Pass
          109.772             -91.0                13.4                 -77.6             -13       Pass
          201.034             -90.5                11.6                 -78.9             -13       Pass
          407.525             -92.9                18.5                 -74.4             -13       Pass
          641.425             -92.6                23.2                 -69.4             -13       Pass
          750.205             -92.6                25.8                 -66.8             -13       Pass




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                     Page 7 of 21
(866) 311-3268 phone, (480) 926-3598 fax                                           p0960008, d0980014 Rev 4.0


Name Of Test:                    Emissions Limitations for Portable Earth Stations
Specification:                   25.202(f)                               Engineer: J Erhard
Test Equipment Utilized          i00331                                  Test Date: 8/10/2009

                                               Test Procedure

The UUT was connected directly to a spectrum analyzer and the conducted spurious emissions were measured
to ensure that the UUT met the requirements specified. Cable and attenuator losses were input into the analyzer
as a reference level offset to ensure accurate measurements were obtained.


                                                 Test Setup

                                      UUT                       Spectrum
                                                                Analyzer


                                  Emissions Limitations Summary Table

                                  Tuned Freq (MHz)     Result    Comments
                                    1611.25 MHz        Pass      See Plots
                                    1618.75 MHz        Pass      See Plots




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                  Page 8 of 21
(866) 311-3268 phone, (480) 926-3598 fax                                        p0960008, d0980014 Rev 4.0


                               Emissions Limitations Plot 1611.25 MHz




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                          Page 9 of 21
(866) 311-3268 phone, (480) 926-3598 fax                                p0960008, d0980014 Rev 4.0


Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                             Page 10 of 21
(866) 311-3268 phone, (480) 926-3598 fax   p0960008, d0980014 Rev 4.0


                               Emissions Limitations Plot 1618.75 MHz




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                          Page 11 of 21
(866) 311-3268 phone, (480) 926-3598 fax                                p0960008, d0980014 Rev 4.0


Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                             Page 12 of 21
(866) 311-3268 phone, (480) 926-3598 fax   p0960008, d0980014 Rev 4.0


Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                             Page 13 of 21
(866) 311-3268 phone, (480) 926-3598 fax   p0960008, d0980014 Rev 4.0


Name Of Test:                    Occupied Bandwidth
Specification:                   N/A                                      Engineer: J Erhard
Test Equipment:                  i00331                                   Test Date: 8/10/2009

There is no requirement for occupied bandwidth in part 25 for portable earth stations however the emissions
masks are based upon the occupied bandwidth. This information is reported for reference only.

                                               Test Procedure

The UUT was connected directly to a spectrum analyzer. The occupied bandwidth of the modulated output was
measured and plotted.


                                   UUT                             Spectrum
                                                                   Analyzer


                                                  Test results

                                     Occupied Bandwidth Results Table

                                Frequency (MHz)         Measured Bandwidth
                                    1611.25                  1.9151
                                    1618.75                  1.9114




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                   Page 14 of 21
(866) 311-3268 phone, (480) 926-3598 fax                                         p0960008, d0980014 Rev 4.0


                                           Occupied Bandwidth

                                              1611.25 MHz




                                              1618.75 MHz




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                  Page 15 of 21
(866) 311-3268 phone, (480) 926-3598 fax                        p0960008, d0980014 Rev 4.0


Name Of Test:                    Emission Masks
Specification:                   25.202(f)                                Engineer: J Erhard
Test Equipment Utilized          i00331                                   Test Date: 8/7/2009

                                                Test Procedure

The UUT was connected directly to a spectrum analyzer to verify that the UUT met the requirements for emission
mask. The reference level was offset for the peak power output with the resolution bandwidth set for greater than
3 times the occupied bandwidth of a modulated signal.
                                                  Test Setup


                                   Spectrum                        UUT
                                   Analyzer


                                      1611.25 MHz Emission Mask Plots




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                   Page 16 of 21
(866) 311-3268 phone, (480) 926-3598 fax                                         p0960008, d0980014 Rev 4.0


                                  1618.75 MHz Emission Mask Plots




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                      Page 17 of 21
(866) 311-3268 phone, (480) 926-3598 fax                            p0960008, d0980014 Rev 4.0


Name Of Test:                    Emissions Limits for Portable Earth Stations
Specification:                   25.216(g)(i)                            Engineer: J Erhard
Test Equipment Utilized          i00331                                  Test Date: 8/10/2009

                                               Test Procedure

The UUT was connected directly to a spectrum analyzer and the conducted spurious emissions were measured
to ensure that the UUT met the requirements specified. Cable and attenuator losses were input into the analyzer
as a reference level offset to ensure accurate measurements were obtained.

                                                 Test Setup

                                       UUT                      Spectrum
                                                                Analyzer


                                Transmitter Unwanted Emissions 25.216 (g)

                                  Tuned Freq (MHz)     Result    Comments
                                      1611.25          Pass      See Plots
                                      1618.75          Pass      See Plots

                                Transmitter Unwanted Emissions 25.216 (i)

                                  Tuned Freq (MHz)     Result    Comments
                                      Off State        Pass      See Plots

                                       Off State Unwanted Emissions




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                  Page 18 of 21
(866) 311-3268 phone, (480) 926-3598 fax                                        p0960008, d0980014 Rev 4.0


                            1611.25 MHz Transmitter Unwanted Emissions




                            1618.75 MHz Transmitter Unwanted Emissions




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                           Page 19 of 21
(866) 311-3268 phone, (480) 926-3598 fax                                 p0960008, d0980014 Rev 4.0


Name Of Test:                                   Frequency Tolerance
Specification:                                  25.202(d)                                  Engineer: J Erhard
Test Equipment Utilized                         i00008, i00027, i00029, i00321             Test Date: 8/5/2009

                                                               Test Procedure

The UUT set to CW operation, placed inside an environmental test chamber, and connected directly to a
spectrum analyzer. The span and RBW was adjusted for narrowband operation to ensure an accurate
measurement of the CW signal could be obtained. The temperature was varied from –30 to +50°C in 10°C
increments. After a 30-minute soak time the output frequency was measured. At 20°C the voltage was varied
+/- 15% from the nominal voltage.

                                                                  Test Setup

                               Power Supply                       UUT                         Spectrum
                                                                                              Analyzer



                                          Frequency Stability vs. Temperature

                         1618.77000
                         1618.76500
                         1618.76000
       Frequency (MHz)




                                                                                                          Upper Limit
                         1618.75500
                                                                                                          Measured Frequency
                         1618.75000
                                                                                                          Low er Limit
                         1618.74500
                         1618.74000
                         1618.73500
                         1618.73000
                                   -30    -20   -10       0      10     20       30   40       50
                                                      Temperature (Centigrade)




                                                       Frequency Stability vs. Voltage

                         1618.77000
                         1618.76500
                         1618.76000
      Frequency (MHz)




                         1618.75500                                                                        Upper Limit
                         1618.75000                                                                        Measured Frequency
                         1618.74500                                                                        Low er Limit
                         1618.74000
                         1618.73500
                         1618.73000
                                   3.83                4.28              4.73                 5.18
                                                              Voltage




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                                      Page 20 of 21
(866) 311-3268 phone, (480) 926-3598 fax                                                            p0960008, d0980014 Rev 4.0


                                          Test Equipment Utilized


          Asset#    Manufacturer            Model         Last Calibration      Calibration Due
          i00008    Kenwood                 PR19-3A       N/A                   N/A
          i00027    Tenney                  Tenney Jr     12/8/2008             12/8/2009
          i00029    HP                      8563E         6/8/2009              6/8/2010
          i00320    Fluke                   75 III        1/7/2009              1/7/2010
          i00331    HP                      8901A         11/3/08               11/3/2009
          i00049    HP                      8566B         12/04/08              12/04/09
          i00267    Schaffner               CBL6111C      11/06/07              11/06/09
          i00266    R&S                     SMT-03        Verify When Used      Verify When Used


In addition to the above listed equipment standard RF connectors and cables were utilized in the testing of the
described equipment. Prior to testing these components were tested to verify proper operation.




END OF TEST REPORT




Compliance Testing
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                  Page 21 of 21
(866) 311-3268 phone, (480) 926-3598 fax                                        p0960008, d0980014 Rev 4.0