Test Report

FCC ID: KZ3050261

Test Report

Download: PDF
FCCID_544669

CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken         Phone: +49 (0) 681 598-0      Fax: -9075
RSC-Laboratory                                        Phone: +49 (0) 681 598-0      Fax: -9075


Test report no.: 2-3850-01-03/05                             Date: 2005-03-10           Page 1 of 28
                                                       Recognized by the
                                              Federal Communications Commission
                                         Anechoic chamber registration no.: 90462 (FCC)
                                          Anechoic chamber registration no.: 3463 (IC)
                                                       TCB ID: DE 0001




                                                       Accredited by the
                                                  German Accreditation Council
                                                   DAR–Registration Number
                                                      TTI–P–G 081/94-D0




                                                        Independent ETSI
                                                      compliance test house



                                                ETSI

                             Accredited Bluetooth® Test Facility (BQTF)




                                      Test report no.            :   2-3850-01-03/05
                                      Applicant                  :   Invisible Fence, Inc
                                      Type                       :   MO261xx
                                      Test Standard              :   FCC Part 15 / RSS210
                                      FCC ID                     :   KZ3050261
                                      Certification No. IC       :   2430A-050261


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken                            Phone: +49 (0) 681 598-0                        Fax: -9075
RSC-Laboratory                                                           Phone: +49 (0) 681 598-0                        Fax: -9075


Test report no.: 2-3850-01-03/05                                                 Date: 2005-03-10                             Page 2 of 28


Table of contents

1       GENERAL INFORMATION................................................................................................................................... 3
    1.1. ADMINISTRATIVE DATA OF THE TEST FACILITY ..................................................................................................... 3
      1.1.1     Identification of the testing laboratory ......................................................................................................... 3
    1.2. NOTES ................................................................................................................................................................... 3
    1.3     DETAILS OF APPLICANT......................................................................................................................................... 4
    1.4     APPLICATION DETAILS .......................................................................................................................................... 4
    1.5     TEST ITEM ............................................................................................................................................................. 5
    1.6     TEST SETUP ........................................................................................................................................................... 6
    1.7     TEST SPECIFICATIONS............................................................................................................................................ 6
2      STATEMENT OF COMPLIANCE .......................................................................................................................... 7
    2.1     SUMMARY OF MEASUREMENT RESULTS ................................................................................................................ 7
      2.1.1    CFR 47 Part 15 Radio frequency devices..................................................................................................... 7
3      MEASUREMENTS AND RESULTS ....................................................................................................................... 8

4      FCC PART 15 SUBPART B ...................................................................................................................................... 9
       4.1        Timing of the transmitter .......................................................................................................................... 9
       4.2        Field strength of the fundamental ........................................................................................................ 11
       4.3        Field strength of the harmonics and the spurious ........................................................................... 11
       4.4        Plots of measurements ............................................................................................................................. 13
       4.6        Conducted Limits ...................................................................................................................................... 16
5      ANNEX B: PHOTOGRAPHS OF TEST SITE ..................................................................................................... 22

6      ANNEX C: EXTERNAL PHOTOGRAPHS OF THE EQUIPMENT ................................................................ 25

7      ANNEX D: INTERNAL PHOTOGRAPHS OF THE EQUIPMENT.................................................................. 27


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken                      Phone: +49 (0) 681 598-0                         Fax: -9075
RSC-Laboratory                                                     Phone: +49 (0) 681 598-0                         Fax: -9075


Test report no.: 2-3850-01-03/05                                           Date: 2005-03-10                               Page 3 of 28




1        General information
1.1.      Administrative data of the test facility
1.1.1     Identification of the testing laboratory
Company name:                                                                 Cetecom ICT Services GmbH
Address:                                                                      Untertürkheimerstr. 6-10
                                                                              D-66117 Saarbruecken
                                                                              Germany
Laboratory accreditation:                                                     DAR-Registration No. TTI-P-G081/94-D0
                                                                              Bluetooth Qualification Test Facility (BQTF)
                                                                              Federal Communications Commission (FCC)
                                                                              Identification/Registration No : 90462
Responsible for testing laboratory:                                           Michael Berg
                                                                              Phone: +49 681 598 0
                                                                              Fax:        +49 681 598 9075
                                                                              email:      info@ict.cetecom.de


1.2.      Notes
The test results of this test report relate exclusively to the test item specified in 1.5. The CETECOM ICT Services GmbH
does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other
specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced
or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the
CETECOM ICT Services GmbH.




                            ..................................................... / ..........................................................
                                                            Responsible for testing laboratory
                                                            (Michael Berg / Dirk Hausknecht)




                           ...................................................... / ..........................................................
                                                                 Responsible for test report
                                                            (Michael Berg / Dirk Hausknecht)


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken          Phone: +49 (0) 681 598-0   Fax: -9075
RSC-Laboratory                                         Phone: +49 (0) 681 598-0   Fax: -9075


Test report no.: 2-3850-01-03/05                             Date: 2005-03-10         Page 4 of 28

1.3       Details of Applicant

Name                :   Invisible Fence, Inc
Address             :   1000 Fuller Drive
City                :   Garrett, IN 46738
Country             :   USA
Phone               :   +1-260 467 5040
Fax                 :   +1-260 467 5103
Contact             :   Mr. Pete Johnson
Phone               :   +1-260 467 5040
Fax                 :   Mr Pete Johnson
e-mail              :   Pete.Johnson@invisibletech.com



1.4       Application Details
Date of receipt of application           :   2005-01-04
Date of receipt of test item             :   2005-01-10
Date(s) of test                          :   2005-01-26 to 2005-01-28
Date of report                           :   2005-03-10


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken    Phone: +49 (0) 681 598-0         Fax: -9075
RSC-Laboratory                                   Phone: +49 (0) 681 598-0         Fax: -9075


Test report no.: 2-3850-01-03/05                         Date: 2005-03-10             Page 5 of 28

1.5       Test Item

Type of equipment                                :          Inductive Loop System (Invisible Fence)
Model name                                       :          MO261xx
Manufacturer                                     :          Invisible Fence, Inc
Address                                          :          1000 Fuller Drive
City                                             :          Garrett, IN 46738
Country                                          :          USA
Tested to Radio Standards Specification(RSS) No. :          210 Issue 5
Open Area Test Site Industry Canada Number       :          3463
Frequency Range (or fixed frequency)             :          7.5 kHz and 10.7 kHz
R F: Power in Watts                              :          -/-
Field Strength (at what distance)                :          116144.9 µV/m (101.3 dBµV/m) in 3m
Occupied Bandwidth (99% BW)                      :
                                                            11.5kHz
Type of Modulation                                   :       ASK
Antenna Information                                  :      Loop antenna up to 3000 feet
Emission Designator                                  :      11K5A1D
Transmitter Spurious (worst case)                    :      74.8 µV/m in 3m
Receiver Spurious (worst case)                       :      -.- µV/m in 3m (noise floor)
IC no.                                               :      2430A-050261
FCC ID                                               :      KZ3050261


ATTESTATION:
DECLARATION OF COMPLIANCE: I declare that the testing was performed or supervised by me; that the test
measurements were made in accordance with the above-mentioned Industry Canada standard(s); and that the equipment
identified in this application has been subjected to all the applicable test conditions specified in the Industry Canada
standards and all of the requirements of the standard have been met.

Laboratory Manager :

2005-03-10                      Michael Berg
Date                            Name                                  Signature


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken        Phone: +49 (0) 681 598-0   Fax: -9075
RSC-Laboratory                                       Phone: +49 (0) 681 598-0   Fax: -9075


Test report no.: 2-3850-01-03/05                           Date: 2005-03-10         Page 6 of 28


1.6       Test Setup

Hardware            :
Software            :

All tests were done with the worst case configuration: 2 Loops ON; max Duty cycle, max
Power, both loops with 10.7 kHz !



1.7       Test Specifications

FCC:                                    CFR Part 15.209
IC:                                     RSS 210, Issue 5


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken       Phone: +49 (0) 681 598-0       Fax: -9075
RSC-Laboratory                                      Phone: +49 (0) 681 598-0       Fax: -9075


Test report no.: 2-3850-01-03/05                          Date: 2005-03-10              Page 7 of 28

2         Statement of Compliance

No deviations from the technical specification(s) were ascertained in the course of the tests performed.

2.1       Summary of Measurement Results

2.1.1     CFR 47 Part 15 Radio frequency devices

 Section in                                                 Test Name / Section RSS 210
                  Test Name / Section FCC Part 15                                               applicable   Verdict
this Report                                                           Issue 5
4.1             § 15.35 (c)                               6.5 Pulsed Operation
                Timing of the transmitter (Duty cycle                                             YES        PASS
                correction factor )
4.2             § 15.209 (a)                             6.2.1 General Field Strength
                FIELDSTRENGTH OF                         Limits (Tables 3 and 7)                  YES        PASS
                FUNDAMENTAL
4.3             § 15.209 (a)                             6.2.1 General Field Strength
                FIELDSTRENGTH OF                         Limits (Tables 3 and 7)                  YES        PASS
                HARMONICS and SPURIOUS
4.4             § 15.109                                 7.3 Receiver Spurious Emissions
                Receiver spurious emissions              (Radiated)                                NO
                (radiated)
4.5             § 15.107 / 15.207 Conducted Limits       Section 6.6 , 7.4                        YES        PASS


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken   Phone: +49 (0) 681 598-0      Fax: -9075
RSC-Laboratory                                  Phone: +49 (0) 681 598-0      Fax: -9075


Test report no.: 2-3850-01-03/05                      Date: 2005-03-10            Page 8 of 28

3         Measurements and results

The radiated measurements are performed in vertical and horizontal plane in the frequency range from 9 kHz to 20 GHz
in semi-anechoic chambers. The EUT is positioned on a non-conductive support with a height of 0.80 m above a
conductive ground plane that covers the whole chamber.
The receiving antennas are conform with specifications ANSI C63.2-1996 clause 15 and ANSI C63.4-2003 clause 4.1.5.
These antennas can be moved over the height range between 1.0 m and 4.0 m in order to search for maximum field
strength emitted from EUT. The measurement distances between EUT and receiving antennas are indicated in the test
set-ups for the various frequency ranges. For each measurement, the EUT is rotated in all three axes until the maximum
field strength is received.
The wanted and unwanted emissions are received by spectrum analysers where the detector modes and resolution
bandwidths over various frequency ranges are set according to requirement ANSI C63.4-2003 clause 4.2.
Antennas are conform with ANSI C63.2-1996 item 15.
150 kHz - 30 MHz: Quasi Peak measurement, 9kHz Bandwidth, passive loop antenna.
30 MHz - 200 MHz: Quasi Peak measurement, 120KHz Bandwidth, biconical antenna
200MHz - 1GHz: Quasi Peak measurement, 120KHz Bandwidth, log periodic antenna
>1GHz: Average, RBW 1MHz, VBW 10 Hz, wave guide horn


All measurement settings are according to FCC 15.109 and 15.107


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken         Phone: +49 (0) 681 598-0      Fax: -9075
RSC-Laboratory                                        Phone: +49 (0) 681 598-0      Fax: -9075


Test report no.: 2-3850-01-03/05                             Date: 2005-03-10            Page 9 of 28



4          FCC Part 15 Subpart B
4.1        Timing of the transmitter
Reference

FCC:                     CFR Part SUBCLAUSE § 15.35 (c)
IC:                      RSS 210, ISSUE 5 6.5 Pulsed operation

Timing
                                  Delta 1 [T1]                           RBW     3 kHz           RF Att      10 dB
          Ref Lvl                                   -5.69 dB             VBW     3 kHz
          -10 dBm                               16.443886 ms             SWT     50 ms           Unit           dBm
    -10
                                                                                   1 [T1]               -32.90 dBm
                                                                                                                      A
                                                                                                 -110.220441 Ì s
    -20
                                                                                   1 [T1]                 -5.69 dB
                                                                                                   16.443886 ms
    -30            1                                                               2 [T1]               -50.07 dB
                                                                                                                      TRG
                                                                                                   32.785571 ms
                                                         1
    -40
          1VIEW                                                                                                       1AP

    -50



    -60



    -70



    -80                                                                                    2



    -90



 -100

                  TR
 -110
          Center 10.7 kHz                                         5 ms/

Date:              28.JAN.2005             09:43:49
ton = 16.4 ms                  ton + toff = 32.4 ms




REFERENCE NUMBER(S) OF TEST EQUIPMENT USED :
( see test equipment listing)


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken          Phone: +49 (0) 681 598-0       Fax: -9075
RSC-Laboratory                                         Phone: +49 (0) 681 598-0       Fax: -9075


Test report no.: 2-3850-01-03/05                             Date: 2005-03-10              Page 10 of 28

Pulse train

                                  Delta 1 [T1]                            RBW      3 kHz           RF Att     10 dB
         Ref Lvl                                     4.55 dB              VBW      3 kHz
         -10 dBm                                100.000000 ms             SWT     200 ms           Unit          dBm
   -10
                                                                                     1 [T1]               -36.51 dBm
                                                                                                                       A
                                                                                                   -591.182365 Ì s
   -20
                                                                                     1 [T1]                 4.55 dB
                                                                                                    100.000000 ms
   -30                                                                1
                                                                                                                       TRG
          1

   -40
         1VIEW                                                                                                         1AP

   -50



   -60



   -70



   -80



   -90



 -100

         TR
 -110
         Center 10.7 kHz                                          20 ms/

Date:              28.JAN.2005             09:47:08

We see a continuous on off keying over more then 100 ms.
This is equivalent to 50 % Duty cycle = -3 dB duty cycle correcting factor

Limits: § 15.35 (c)

 (c) Unless otherwise specified, e.g. Section 15.255(b), when the radiated emission limits are
 expressed in terms of the average value of the emission, and pulsed operation is employed, the
 measurement field strength shall be determined by averaging over one complete pulse train,
 including blanking intervals, as long as the pulse train does not exceed 0.1 seconds. As an
 alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases where the
 pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the average
 absolute voltage during a 0.1 second interval during which the field strength is at its maximum
 value. The exact method of calculating the average field strength shall be submitted with any
 application for certification or shall be retained in the measurement data file for equipment subject
 to notification or verification.




REFERENCE NUMBER(S) OF TEST EQUIPMENT USED :
( see test equipment listing)


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken        Phone: +49 (0) 681 598-0        Fax: -9075
RSC-Laboratory                                       Phone: +49 (0) 681 598-0        Fax: -9075


Test report no.: 2-3850-01-03/05                           Date: 2005-03-10              Page 11 of 28


4.2       Field strength of the fundamental
Reference

FCC:                     CFR Part SUBCLAUSE § 15.209 (a)
IC:                      RSS 210, Issue 5,6.2.1 General Field Strength Limits (Tables 3 and 7)




Maximum output power (average) - (radiated)


          TEST CONDITIONS                                       MAXIMUM POWER (mV/m)


                  Frequency                              10.7 kHz

  Tnom +23 °C             Vnom 120V AC               11.61 µV (AV)
                                                   21.3 dBµV/m (AV)
       Measured Peak value                         24.3 dBµV/m (PK)
    Duty cycle correction factor                          3 dB
 Maximum deviation from output
     power under extreme test                                               not applicable
         conditions (dBc)
     Measurement uncertainty                                                    ±3dB
RBW/VBW : 1 MHz
Calculated limit for 10.7 kHz = 224.3 µV

Limits                                                                                 SUBCLAUSE § 15.209

        Frequency (MHz)                         Field strength (µV/m)             Measurement distance (m)
         0.0009 – 0.490                              2400/F(kHz)                           300
          0.490 – 1.705                             24000/F(kHz)                           30
            1.705 - 30                                     30                               30
             30 - 88                                      100                                3
             88 - 216                                     150                                3
            216 - 960                                     200                                3
            above 960                                     500                               3



4.3       Field strength of the harmonics and the spurious

Reference

FCC:                     CFR Part SUBCLAUSE § 15.209 (a)
IC:                      RSS 210, Issue 5, 6.2.1 General Field Strength Limits (Tables 3 and 7)

REFERENCE NUMBER(S) OF TEST EQUIPMENT USED :
( see test equipment listing)


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken        Phone: +49 (0) 681 598-0             Fax: -9075
RSC-Laboratory                                       Phone: +49 (0) 681 598-0             Fax: -9075


Test report no.: 2-3850-01-03/05                     Date: 2005-03-10                Page 12 of 28



                                     EMISSION LIMITATIONS
                        amplitude of        limit
   f                     emission        max. allowed  Margin to limit
                                                                                                        results
 (MHz)                    (µV/m)       emmision power      (dB)
                        Average/QP         (µV/m)
 0.00107                    21.3            224.3                                                      Operating
                                                                                                       frequency
 0.0214            0.6                               112.1                         45.8                 complies
 0.0321            0.4                               74.8                          45.5                 complies
 0.0428            0.2                               56.1                          47.4                 complies
 0.0535            0.2                               44.9                          47.6                 complies
 0.0642            0.1                               37.4                          51.7                 complies
 0.0749           0.06                                32.0                         54.1                 complies
 0.0856           0.04                                28.0                         57.3                 complies
 0.0963           0.02                                24.9                         60.4                 complies
 0.107            0.06                               22.4                          51.2                 complies
 0.1177           0.06                                20.4                         51.0                 complies
 5.683            0.02                                 30                          62.8                 complies
 10.69            0.05                                 30                          56.4                 complies
 32.92            21.1                                100                          13.5                 complies
  35.6            16.8                                100                          15.5                 complies
   Measurement uncertainty                                                      ± 3dB


Limits                                                                                    SUBCLAUSE § 15.209

        Frequency (MHz)                         Field strength (µV/m)               Measurement distance (m)
         0.0009 – 0.490                              2400/F(kHz)                             300
          0.490 – 1.705                             24000/F(kHz)                             30
            1.705 - 30                                     30                                 30
             30 - 88                                      100                                  3
             88 - 216                                     150                                  3
            216 - 960                                     200                                  3
            above 960                                     500                                 3




REFERENCE NUMBER(S) OF TEST EQUIPMENT USED :
( see test equipment listing)


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken            Phone: +49 (0) 681 598-0                  Fax: -9075
RSC-Laboratory                                           Phone: +49 (0) 681 598-0                  Fax: -9075


Test report no.: 2-3850-01-03/05                         Date: 2005-03-10                     Page 13 of 28



4.4       Plots of measurements
Plot 1:
Part 15.209 Magnetics TX

Results : both loops with 10.7 kHz


                            EMI-TEST                                                     27 Jan 2005 11:02:48
            hp              EMISSION LEVEL[        dBuV/m]            PEAK       QUASI-PEAK
                120
                                                                             3m magn
                                      FCC 15.209                             Invisible Technologies Inc.
                                                                             MO 261xx
                                                                             10.7 kHz & 10.7 KHz
                                                                             Rx ant. vert/hor. max. Hold
                100




                80




                60




                40




                      .01                          .1                               1                           10          30

                                                              FREQUENCY [MHz]




(to convert the measuring distance from 3m to 30m and 30 to 300m a correction factor from
40 dB/decade was used.)
Measurement distance 3m
This measurement was done in 3 polarisation’s, the plot shows the worst case

Limits                                                                                              SUBCLAUSE § 15.209
           Frequency (MHz)                         Field strength (µV/m)                         Measurement distance (m)
            0.0009 – 0.490                              2400/F(kHz)                                       300
             0.490 – 1.705                             24000/F(kHz)                                       30
               1.705 - 30                                     30                                          30
                 30 - 88                                     100                                           3
                88 - 216                                     150                                           3
               216 - 960                                     200                                           3
               above 960                                     500                                           3




REFERENCE NUMBER(S) OF TEST EQUIPMENT USED :
( see test equipment listing)


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken            Phone: +49 (0) 681 598-0                  Fax: -9075
RSC-Laboratory                                           Phone: +49 (0) 681 598-0                  Fax: -9075


Test report no.: 2-3850-01-03/05                         Date: 2005-03-10                     Page 14 of 28


Results : one loops 10.7 kHz and one at 7.5 kHz



                            EMI-TEST                                                     27 Jan 2005 10:53:00
            hp              EMISSION LEVEL[        dBuV/m]            PEAK       QUASI-PEAK
                120
                                                                             3m magn
                                      FCC 15.209                             Invisible Technologies Inc.
                                                                             MO 261xx
                                                                             7.5 kHz & 10.7 KHz
                                                                             Rx ant. vert/hor. max. Hold
                100




                80




                60




                40




                      .01                          .1                               1                           10          30

                                                              FREQUENCY [MHz]




(to convert the measuring distance from 3m to 30m and 30 to 300m a correction factor from
40 dB/decade was used.)

Measurement distance 3m
This measurement was done in 3 polarisation’s, the plot shows the worst case

Limits                                                                                              SUBCLAUSE § 15.209
           Frequency (MHz)                         Field strength (µV/m)                         Measurement distance (m)
            0.0009 – 0.490                              2400/F(kHz)                                       300
             0.490 – 1.705                             24000/F(kHz)                                       30
               1.705 - 30                                     30                                          30
                 30 - 88                                     100                                           3
                88 - 216                                     150                                           3
               216 - 960                                     200                                           3
               above 960                                     500                                           3




REFERENCE NUMBER(S) OF TEST EQUIPMENT USED :
( see test equipment listing)


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken                   Phone: +49 (0) 681 598-0                     Fax: -9075
RSC-Laboratory                                                  Phone: +49 (0) 681 598-0                     Fax: -9075


Test report no.: 2-3850-01-03/05                                Date: 2005-03-10                        Page 15 of 28

Plot 2:
Low Channel TX (30 MHz to 4 GHz)
Results : both loops with 10.7 kHz


                            EMI-TEST                                                              27 Jan 2005 10:30:33
            hp              EMISSION LEVEL[           dBuV/m]                PEAK        QUASI-PEAK
                 100
                                                                                    FCC Part 15.209
                                                                                    Invisible Technologies Inc.
                                                                                    MO 261xx
                                                                                    both 10.7 KHz
                                                                                    Rx ant. vert/hor. max. Hold
                 80




                 60
                                                                                                                          Part 15.209




                 40




                 20




                       30                       100                                                           1000                      4000

                                                                     FREQUENCY [MHz]




Plot 3:
Results : one loops 10.7 kHz and one at 7.5 kHz


                            EMI-TEST                                                              27 Jan 2005 10:41:48
            hp              EMISSION LEVEL[           dBuV/m]                PEAK        QUASI-PEAK
                 100
                                                                                    FCC Part 15.209
                                                                                    Invisible Technologies Inc.
                                                                                    MO 261xx
                                                                                    7.5 kHz & 10.7 KHz
                                                                                    Rx ant. vert/hor. max. Hold
                 80




                 60
                                                                                                                          Part 15.209




                 40




                 20




                       30                       100                                                           1000                      4000

                                                                     FREQUENCY [MHz]




REFERENCE NUMBER(S) OF TEST EQUIPMENT USED :
( see test equipment listing)


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken                      Phone: +49 (0) 681 598-0          Fax: -9075
RSC-Laboratory                                                     Phone: +49 (0) 681 598-0          Fax: -9075


Test report no.: 2-3850-01-03/05                                   Date: 2005-03-10            Page 16 of 28



4.6            Conducted Limits
TX Mode

Reference

FCC:                               CFR Part 15.207, 15.107
IC:                                RSS 210, Issue 4, Section 6.6 , 7.4



EUT:                                      MO261xx
Manufacturer:                             Invisible Technologies
Operating Condition:                      normal operating mode
Test Site:                                CETECOM ICT Services Room 006
Operator:                                 Berg M.
Test Specification:                       CISPR 22 / EN 55022
Power Supply:                             110 V AC
Start of Test:                            28.01.05 / 07:50:07


SCAN TABLE: "EN 55022 V"

    Short Description:                                     Voltage Mains 1.60
    Start      Stop                              Step         Detector Meas.     IF                      Transducer
    Frequency Frequency                          Width                  Time     Bandw.
    150.0 kHz 30.0 MHz                           7.5 kHz      MaxPeak   100.0 ms 10 kHz                  ESH3-Z5 L1 1458
                                                              Average




       Level [dBµV]
 100




    80




    60
                                                                                                     x                xxx
                                                                                                     x x xx
                                                                                                    x x x           xx      x
                                                                                                   x                        x
    40                                                                                                                 x




    20




         0
              150k          300k          500k              1M              2M        3M      5M        7M    10M               30M
                                                           Frequency [Hz]

x            MES 55022 V AC_fin QP
             MES 55022 V AC_pre PK
             LIM EN 55022 V QP     Voltage QP Limit
             LIM EN 55022 V AV     Voltage AV Limit




REFERENCE NUMBER(S) OF TEST EQUIPMENT USED :
( see test equipment listing)


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken        Phone: +49 (0) 681 598-0       Fax: -9075
RSC-Laboratory                                       Phone: +49 (0) 681 598-0       Fax: -9075


Test report no.: 2-3850-01-03/05                     Date: 2005-03-10             Page 17 of 28



MEASUREMENT RESULT: "55022 V AC_fin QP"

28.01.05 07:58
   Frequency   Level                    Transd     Limit     Margin        Line    PE
         MHz    dBµV                        dB      dBµV         dB

      5.535000              43.60           10.7      60         16.4      L1     FLO
      5.640000              47.70           10.7      60         12.3      L1     FLO
      5.752500              54.10           10.7      60          5.9      N      FLO
      5.767500              51.00           10.7      60          9.0      N      FLO
      6.352500              49.20           10.6      60         10.8      N      FLO
      6.435000              51.10           10.6      60          8.9      N      FLO
      6.825000              46.30           10.6      60         13.7      N      FLO
      6.855000              49.70           10.6      60         10.3      N      FLO
      6.907500              50.70           10.6      60          9.3      N      FLO
      6.930000              50.60           10.6      60          9.4      N      FLO
     10.845000              47.60           10.8      60         12.4      N      GND
     10.935000              49.30           10.8      60         10.7      N      GND
     11.130000              55.50           10.8      60          4.5      L1     GND
     11.272500              55.50           10.8      60          4.5      L1     GND


Limits: § 15.107 / 15.207

 Frequency of Emission (MHz)                                       Conducted Limit (dBµV)

                                                Quasi-peak                                   Average
            0.15 – 0.5                          66 to 56 *                                  56 to 46 *
              0.5 – 5                               56                                          46
              5 - 30                                60                                          50
* Decreases with the logarithm of the frequency




REFERENCE NUMBER(S) OF TEST EQUIPMENT USED :
( see test equipment listing)


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken               Phone: +49 (0) 681 598-0        Fax: -9075
RSC-Laboratory                                              Phone: +49 (0) 681 598-0        Fax: -9075


Test report no.: 2-3850-01-03/05                            Date: 2005-03-10              Page 18 of 28


Used Testequipment

               Device                          Manufacturer                   Type            S/N Number   Inv. No. Cetecom
Spektrum Analyser                           HP                          8566B                2747A05306    300001000
Spektrum Analyser Display                   HP                          85662A               2816A16541    300002297
Quasi-Peak-Adapter                          HP                          85650A               2811A01131    300000999
Power Dupply                                HP                          6032A                2818A03450    300001040
Power Attenuator                            Byrd                        8325                 1530          300001595
Bikonical Antenna                           EMCO                        3104                 3758          300001602
Log. Period. Antenna                        EMCO                        3146                 2130          300001603
Double Ridged Antenna                       EMCO                        HP 3115P             3088          300001032
Active Loop Antenna                         EMCO                        6502                 2210          300001015
Antenna VDE/FCC                                                         HP11965B                           300002298
SRM-Drive                                   HP                          9144A                2823e46556    300001044
Software                                    HP                          EMI                                300000983
Busisolator                                 Kontron                                                        300001056
Absorberhalle                               MWB                                              87400/02      300000996
Salzsäule                                   Kontron                                                        300001055
Antenna                                     R&S                         HMO20                832211/003    300002243
Indukt.Tast Antenna                         R&S                         HFH 2 Z4             881468/026    300001464
System-Rack                                 HP I.V.                     85900                *             300000222
Spectrum Analyzer                           HP                          8566B                2747A05275    300000219
Quasi-Peak-Adapter                          HP                          85650A               2811A01135    300000216
RF-Preselector                              HP                          85685A               2837A00779    300000218
Rahmen Antenne                              R&S                         HFH2-Z2              891847-35     300001169
Leitungsteiler                              HP                          11850C                             300000997
Breitband-Hornantenne EMI                   HP                          35155P                             300002300
PC                                          HP                          Vectra VL                          300001688
VHF Meßantenne                              Schwarzbeck                 VHA 9103                           300001778
Spectrum Analyzer Display                   HP                          85662A               2816A16497    300001690
VHF Meßantenna                              Schwarzbeck                 VHA 9103                           300001780
Biconical Antenna                           EMCO                        3104 C               9909-4868     300002590


SRD Laboratory:

                                                300001207                        Type        S/N Number Inv. No. Cetecom
Device
Spectrum Analyzer                               300001208                494AP               B010241       300000863
Spectrum Analyzer                               HP                       71210A (70000)      2731A02347    300000321
Spectrum Analyzer Display                       HP                       70206A              2840A01553    300002017
Reference Frequency                             HP                       70310A              2736A00707    300002018
Local Oscillator                                HP                       70900A              2842A02221    300002019
ZF-Modul 10Hz-300 kHz                           HP                       70902A              2840A02145    300002020
ZF-Modul 100 kHz-3 MHz                          HP                       70903A              2835A01069    300002021
HF-Teil für 71210A 100Hz- 22GHz                 HP                       70908A                            300002022
Spectrum Analyzer 2                             HP                       85660B              3138A07614
Spectrum Analyzer Display 2                     HP                       85662A              3144A20627


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken             Phone: +49 (0) 681 598-0     Fax: -9075
RSC-Laboratory                                            Phone: +49 (0) 681 598-0     Fax: -9075


Test report no.: 2-3850-01-03/05                          Date: 2005-03-10           Page 19 of 28

Signal Generator DC-600 KHz                     HP                     8904A            2822A01213   300001157
Signal Generator DC-600 KHz                     HP                     8904A            2822A01214   300001158
Powersupply                                     HP                     6038A            3122A11097   300001204
Netznachbildung                                 R&S                    ESH3-Z5          828576/020   300001210
Amplituden Controller                           R&S                    SMDU-Z2          871829/051   300002309
Trenntrafo                                      Erfi                   913501                        300001205
Trenntrafo                                      Grundig                RT5A             9242         300001627
Relais Matrix                                   HP                     3488A            2719A15013   300001156
Multimeter                                      Siemens                Multizet                      300001102
Peak Power Calibrator                           HP                     8900B                         300001084
Schallgeber                                     Schomandl              SG 1             10159        300001209
Schallgeber                                     Schomandl              SG 2             10176        300002473
Filter                                          FSY Microwave                                        300001206
Attenuatorer                                    Pro Nova                                             300002476
Klimaschrank                                    Heraeus Voetsch        VUK04/500                     300001012
Spectrum Analyzer 3                             HP                     8566A            1925A00257   300001098
Spectrum Analyzer Display 3                     HP                     85662            1925A00860   300002306
Oszilloscope                                    Tektronix              2432             110261       300001165
Radiocom. Analyzer                              R&S                    CMTA 54          894043/010   300001175
Powersupply                                     HP                     6038A            2848A07027   300001174
Signal Generator 0.01-1280 MHz                  HP                     8662A            2224A01012   300001110
Signal Generator (Funktions)                    R&S                    AFGU             862490/032   300001201
Trenntrafo                                      Erfi                   MPL              91350        300001155
Relais Matrix                                   R&S                    PSU              893285/020   300001173
Power Meter                                     HP                     436A             2101A12378   300001136
Powersensor                                     HP                     8484A            2237A10156   300001140
Powersensor                                     HP                     8482A            2237A06016   300001139
Relais Matrix                                   R&S                    PSU              282628/004   300001214
Powersupply                                     Zentro                                  2007         300001109
Oszilloscope                                    Tektronix              7633                          300001111
Klimaschrank                                    Heraeus Voetsch        VUK04/500        32926        300001500
Quasi-Peak Adapter                              HP                     85650A           2811A01204   300002308
Radiocom. Analyzer                              R&S                    CMTA 84          894199/012   300001176
Oszilloscope                                    HP                     54510A           3022A02062   300001202
Funkmeßplatz                                    Schomandl              FD1000           34982        300001115
Signal Generator                                R&S                    SMPC             882416/019   300001162
Frequency counter                               HP                     5340A            2116A08138   300001104
Power Meter                                     HP                     436A             2031U01461   300001105
Powersensor                                     HP                     8482A                         300001106
Powersensor                                     HP                     8484A                         300001107
Powersensor                                     HP                     8485A                         300001108
Powersupply                                     HP                     6038A            2752A04866   300001161
Reflectionsmeter                                R&S                    NAP              879191       300001132
Signal Generator NF                             R&S                    SPN              880139/068   300001142
Trenntrafo                                      Erfi                   MPL              91350        300001151
Attenuator                                      JFW                    30 db            1350h/104    300001703
Attenuator                                      JFW                    10 db            1350h/103    300001704
Attenuator                                      JFW                    20 db            1350h/106    300001705
Attenuator                                      JFW                    20 db            1350h/105    300001766
Filter                                          Spinner                153755                        300001791


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken             Phone: +49 (0) 681 598-0     Fax: -9075
RSC-Laboratory                                            Phone: +49 (0) 681 598-0     Fax: -9075


Test report no.: 2-3850-01-03/05                          Date: 2005-03-10           Page 20 of 28

Powersensor                                     HP                     8484A            2237A10494   300001666
Powersupply                                     HP                     6038A            3122A11097   300001204
Netznachbildung                                 R&S                    ESH3-Z5          828576/020   300001210
Amplituden Controller                           R&S                    SMDU-Z2          871829/051   300002309
Trenntrafo                                      Erfi                   913501                        300001205
Trenntrafo                                      Grundig                RT5A             9242         300001627
Relais Matrix                                   HP                     3488A            2719A15013   300001156
Multimeter                                      Siemens                Multizet                      300001102
Peak Power Calibrator                           HP                     8900B                         300001084
Schallgeber                                     Schomandl              SG 1             10159        300001209
Schallgeber                                     Schomandl              SG 2             10176        300002473
Filter                                          FSY Microwave                                        300001206
Attenuatorer                                    Pro Nova                                             300002476
Klimaschrank                                    Heraeus Voetsch        VUK04/500                     300001012
Spectrum Analyzer 3                             HP                     8566A            1925A00257   300001098
Spectrum Analyzer Display 3                     HP                     85662            1925A00860   300002306
Oszilloscope                                    Tektronix              2432             110261       300001165
Radiocom. Analyzer                              R&S                    CMTA 54          894043/010   300001175
Powersupply                                     HP                     6038A            2848A07027   300001174
Signal Generator 0.01-1280 MHz                  HP                     8662A            2224A01012   300001110
Signal Generator (Funktions)                    R&S                    AFGU             862490/032   300001201
Trenntrafo                                      Erfi                   MPL              91350        300001155
Relais Matrix                                   R&S                    PSU              893285/020   300001173
Power Meter                                     HP                     436A             2101A12378   300001136
Powersensor                                     HP                     8484A            2237A10156   300001140
Powersensor                                     HP                     8482A            2237A06016   300001139
Relais Matrix                                   R&S                    PSU              282628/004   300001214
Powersupply                                     Zentro                                  2007         300001109
Oszilloscope                                    Tektronix              7633                          300001111
Klimaschrank                                    Heraeus Voetsch        VUK04/500        32926        300001500
Quasi-Peak Adapter                              HP                     85650A           2811A01204   300002308
Radiocom. Analyzer                              R&S                    CMTA 84          894199/012   300001176
Oszilloscope                                    HP                     54510A           3022A02062   300001202
Funkmeßplatz                                    Schomandl              FD1000           34982        300001115
Signal Generator                                R&S                    SMPC             882416/019   300001162
Frequency counter                               HP                     5340A            2116A08138   300001104
Power Meter                                     HP                     436A             2031U01461   300001105
Powersensor                                     HP                     8482A                         300001106
Powersensor                                     HP                     8484A                         300001107
Powersensor                                     HP                     8485A                         300001108
Powersupply                                     HP                     6038A            2752A04866   300001161
Reflectionsmeter                                R&S                    NAP              879191       300001132
Signal Generator NF                             R&S                    SPN              880139/068   300001142
Trenntrafo                                      Erfi                   MPL              91350        300001151
Attenuator                                      JFW                    30 db            1350h/104    300001703
Attenuator                                      JFW                    10 db            1350h/103    300001704
Attenuator                                      JFW                    20 db            1350h/106    300001705
Attenuator                                      JFW                    20 db            1350h/105    300001766
Filter                                          Spinner                153755                        300001791
Powersensor                                     HP                     8484A            2237A10494   300001666


CETECOM ICT Services GmbH
Untertürkheimer Str. 6-10, 66117 Saarbruecken              Phone: +49 (0) 681 598-0      Fax: -9075
RSC-Laboratory                                             Phone: +49 (0) 681 598-0      Fax: -9075


Test report no.: 2-3850-01-03/05                           Date: 2005-03-10            Page 21 of 28

Powersensor                                     HP                      8485A             2238A00849   300001668
Bandfilter                                      Telonic                 TTF7255EE         20293-11     300001300
Bandfilter                                      Telonic                 TTF12555EE        20292-6      300001302
Bandfilter                                      Telonic                 TTF25055EE        20291-8      300001304
Bandfilter                                      Telonic                 TTF50055EE        20290-7      300001305
Bandfilter                                      Telonic                 TTF100055EE       20289-7      300001307
Bandfilter                                      Telonic                 TTA300055EESN     20370-2      300001312
Bandstop                                        Telonic                 TTR3753EE1        30013-1      300001314
Bandstop                                        Telonic                 TTR723EE          20417-2      300001316
Bandstop                                        Telonic                 TTR95-3EE         20372-4      300001318
Bandstop                                        Telonic                 TTR1903EE         30036-4      300001320
Bandstop                                        Telonic                 TTR3753EE         20369-5      300001321
Bandstop                                        Telonic                 TTR750-3EE1       90177-1      300002387
Highpass                                        Pro Nova                HDP120-6GG        ohne         300001348
Highpass                                        Pro Nova                HMC500-6AA        HJ67-01?     300001350
Highpass                                        Narda                   NHP 9000          0004         300001362
Highpass                                        Narda                   HDP16-6GH         JV70-01      300001364
Highpass                                        RSD                     HDP50-6GH,                     300001371
                                                                        HDP200-6GG
Highpass                                        RSD                     2099-02-01                   300000370
Signal Generator 0.1-2060 MHz                   HP                      8657A             2838U00736 300001009
Radio Code Analyzer                             Schlumberger            SL4922                       300001038
Signal Analyzer                                 B&K                     2033                         300001047
Frequency counter                               HP                      5386A             2704A01243 300000998
Laufzeitelement                                 WR-Elektronik                                        300001036
Powersupply Stromversorgung                     Systron                 M5P 40/15A        828233     300001291
Powersupply                                     Heiden                  1108-32           1701       300001392
Powersupply                                     Heiden                  1108-32           1802       300001383
Powersupply                                     Heiden                  1108-32           003202     300001187
Powersupply                                     Zentro                  LA 2x30/5GB1      2011       300001276
Powersupply                                     Zentro                  LA 2x30/5GB2      2012       300001275
Powersupply                                     Zentro                  LA 30/5GA         2041,2042  300001287
Trenntrafo                                      Grundig                 RT5A              8781       300001277
Trenntrafo                                      Grundig                 RT5A              9242       300001263
Multimeter                                      Goerz Elektro           Unigor 6e P       911 355    300001625
Multimeter                                      Goerz Elektro           Unigor 6e P       911 391    300001281
Climatic Box                                    Heraeus Voetsch         VUK04/500         32679      300000299
Powersensor + Att.                              HP                      8482B             2703A02586 300001492
Attenuator 30 dB                                HP                      8498A             1801A02445 300001475
Signal Generator NF                             HP                                        2822A01203 300001004
Attenuator                                      Spinner                 BN 534171 D       51881      300001516
Attenuator coaxial                              Bird                    8325              2429       300001513
Impulsbegrenzer                                 R&S                     ESH 3 Z2                     300001460
4Port Box                                       R&S                     4Port Box         860457/005 300001472
Signal Generator 0.1-4200 MHz                   HP                      8665A             2833A0011 300002299
NF-Spektrumanalyzer                             B&K                     2033A                        300002301
Swissphone Freifeld-Messbox                     Swissphone Schweiz                                   300002302
Trenntrafo regelbar                             Grundig                 RT5H              9242       300001628
Signal Generator                                HP                      8111A             2215G00867 300001117



Document Created: 2005-05-09 16:26:21
Document Modified: 2005-05-09 16:26:21

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC