Test Report

FCC ID: KUTTM318

Test Report

Download: PDF
FCCID_1255379

             FCC Test Report
             E4064135901KY

Type / Model Name:     TM-318-1 and TM-318-2




Product Description:   Lighting remote control




Applicant:             Capital Prospect Ltd.




FCC ID:                KUTTM318


                               FCC -- T E S T R E P O R T

                                                                                                    January 13, 2010
     Test Report No. :                        E4064135901KY                            ______________________________________________________________________________________________

                                                                                                            Date of issue




       Type / Model Name                        : TM-318-1 and TM-318-2


       Product Description                      : Lighting remote control



       Applicant                                : Capital Prospect LTD.

       Address                                  : Room 03, 13/F., Block B,

                                                   Veristrong Ind. Centre, 34-36 Au Pui Wan Street,

                                                   Fo Tan, N.T.,

                                                   Hong Kong



     Test Result according to the
     standards listed in clause 1 test                                                   PASS
     standards:


    The test report merely corresponds to the test sample.
    It is not permitted to copy extracts of these test results without the written permission of the test laboratory.




FCC ID:KUTTM318                                                                          File No. E4064135901KY, page 2 of 16


               emitel (Shenzhen) Limited, Building 2, 171 Meihua Road, Futian District, Shenzhen, P.R.China 518049
                                                  F10_25_Rev5_0 Freigabe: 15.03.2006


                                                     Contents

    1     TEST STANDARDS                                                                                             4



    2     SUMMARY                                                                                                    5



    3     EQUIPMENT UNDER TEST                                                                                       6

    3.1    PHOTO DOCUMENTATION OF THE EUT                                                                            6
    3.2    POWER SUPPLY SYSTEM UTILISED                                                                              7
    3.3    SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT)                                                       7


    4     TEST ENVIRONMENT                                                                                           8

    4.1    ADDRESS OF THE TEST LABORATORY                                                                            8
    4.2    ENVIRONMENTAL CONDITIONS                                                                                  8
    4.3    STATEMENT OF THE MEASUREMENT UNCERTAINTY                                                                  8


    5     TEST CONDITIONS AND RESULTS                                                                                9

    5.1    AVERAGE FACTOR                                                                                            9
    5.2    RADIATED EMISSION                                                                                        12
    5.3    BANDWIDTH                                                                                                14
    5.4    PROVISION OF MOMENTARY OPERATION                                                                         15


    6     USED TEST EQUIPMENT AND ACCESSORIES                                                                       16




FCC ID:KUTTM318                                                                       File No. E4064135901KY, page 3 of 16


              emitel (Shenzhen) Limited, Building 2, 171 Meihua Road, Futian District, Shenzhen, P.R.China 518049
                                                 F10_25_Rev5_0 Freigabe: 15.03.2006


1 TEST STANDARDS

The tests were performed according to following standards:

FCC Part 15, July 10, 2008                               Federal Communications Commission, Part 15 – Radio
                                                         Frequency Device

ANSI C63.4:2003                                          Method of Measurement of Radio-Noise Emissions from Low-
                                                         Voltage Electrical and Electronic Equipment in the Range of
                                                         9 kHz to 40 GHz




FCC ID:KUTTM318                                                                         File No. E4064135901KY, page 4 of 16


                emitel (Shenzhen) Limited, Building 2, 171 Meihua Road, Futian District, Shenzhen, P.R.China 518049
                                                   F10_25_Rev5_0 Freigabe: 15.03.2006


2 SUMMARY

GENERAL REMARKS:
Model: TM-318-1 is identical as TM-318-2 except the number of key. TM-318-1 and TM-318-2 have one key and
two keys respectively. The model TM-318-2 is selected as represented model for testing.




FINAL ASSESSMENT:
The equipment under test fulfils the technical requirement cited in section 15.231 of FCC Part 15



Date of receipt of test sample           :   December 30, 2009


Testing commenced on                     :   December 30, 2009


Testing concluded on                     :   November 13, 2009




Reviewed by:                                                                             Prepared by:
                                                                                                           Digitally signed
                                                                                                           by kidd
                                                                                                           Location: emitel
                                                                                                           SZ
 Wilson Loke                                                                              Kidd Yang
 Senior Manager                                                                           Engineer




FCC ID:KUTTM318                                                                             File No. E4064135901KY, page 5 of 16


                 emitel (Shenzhen) Limited, Building 2, 171 Meihua Road, Futian District, Shenzhen, P.R.China 518049
                                                    F10_25_Rev5_0 Freigabe: 15.03.2006


3 EQUIPMENT UNDER TEST
3.1   Photo documentation of the EuT
                                                        TM-318-1




                                                        Front View




                                                        Back View
FCC ID:KUTTM318                                                                     File No. E4064135901KY, page 6 of 16


            emitel (Shenzhen) Limited, Building 2, 171 Meihua Road, Futian District, Shenzhen, P.R.China 518049
                                               F10_25_Rev5_0 Freigabe: 15.03.2006


3.2     Power supply system utilised

Power supply voltage:                         3VDC(CR2032 lithium battery)


3.3     Short description of the Equipment under Test (EuT)
The Equipment under test (EUT) is a 318MHz transmitter. The main function of the EUT is acted as a remote
control to provide a control signal to control the lighting receiver modules. When the buttons are pressed, the
transmitter will transmit the signal by Pulsed Code Modulation to lighting receive modules (receiver) to control the
bightness of the lighting equipment. The EUT is powered by one 3VDC lithium battery.


Number of tested samples:          One
Serial number:                     Not Labelled
Dimensions:                        L: 7.0cm                W: 3.5cm                      H: 1.0cm




EuT operation mode:
The equipment under test was operated during the measurement under the following conditions:


- Operation mode 1: Transimitting mode

- Operation mode 2: N/A

- Operation mode 3: N/A

EuT configuration:
(The CDF filled by the applicant can be viewed at the test laboratory.)

The following peripheral devices and interface cables were connected during the measurements:

-   None                                                     Model :

-                                                            Model :

-                                                            Model :

-                                                            Model :

-                                                            Model :

-                                                            Model :




FCC ID:KUTTM318                                                                             File No. E4064135901KY, page 7 of 16


                 emitel (Shenzhen) Limited, Building 2, 171 Meihua Road, Futian District, Shenzhen, P.R.China 518049
                                                    F10_25_Rev5_0 Freigabe: 15.03.2006


4 TEST ENVIRONMENT
4.1     Address of the test laboratory

      emitel (Shenzhen) Limited
      Building 2, 171 Meihua Road,
      Futian District,
      Shenzhen, 518049
      China

      FCC Registration No.: 746887


4.2     Environmental conditions

During the measurement the environmental conditions were within the listed ranges:

Temperature:                                    15-35 ° C


Humidity:                                        30-60 %


Atmospheric pressure:                          86-106 kPa




4.3     Statement of the measurement uncertainty

The data and results referenced in this document are true and accurate. The reader is cautioned that there may
be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated
for all measurements listed in this test report acc. to CISPR 16-4-2 /11.2003 „Uncertainties, statistics and limit
modelling – Uncertainty in EMC measurements“ and is documented in the quality system acc. to ISO 17025.
Furthermore, component and process variability of devices similar to that tested may result in additional deviation.
The manufacturer has the sole responsibility of continued compliance of the device.




FCC ID:KUTTM318                                                                          File No. E4064135901KY, page 8 of 16


                 emitel (Shenzhen) Limited, Building 2, 171 Meihua Road, Futian District, Shenzhen, P.R.China 518049
                                                    F10_25_Rev5_0 Freigabe: 15.03.2006


5 TEST CONDITIONS AND RESULTS
5.1     Average Factor
For test instruments and accessories used see section 6.
5.1.1   Description of the test location

Test location: Shield room

5.1.2   Photo documentation of test




FCC ID:KUTTM318                                                                         File No. E4064135901KY, page 9 of 16


                emitel (Shenzhen) Limited, Building 2, 171 Meihua Road, Futian District, Shenzhen, P.R.China 518049
                                                   F10_25_Rev5_0 Freigabe: 15.03.2006


FCC ID:KUTTM318                                                                     File No. E4064135901KY, page 10 of 16


            emitel (Shenzhen) Limited, Building 2, 171 Meihua Road, Futian District, Shenzhen, P.R.China 518049
                                               F10_25_Rev5_0 Freigabe: 15.03.2006


5.1.3    Test result

                                   Ton=        (2.9+0.22*44+0.4*4+0.8*3)ms
                                      =        16.58ms
        Average Factor (Press Switch) =        20 ㏒(16.58ms/55.8ms)
                                      =        -10.5dB



Remarks:          Average factor of 2 buttons are measured and worst case average factor is reported above.




FCC ID:KUTTM318                                                                           File No. E4064135901KY, page 11 of 16


                  emitel (Shenzhen) Limited, Building 2, 171 Meihua Road, Futian District, Shenzhen, P.R.China 518049
                                                     F10_25_Rev5_0 Freigabe: 15.03.2006


5.2     Radiated Emission
For test instruments and accessories used see section 6.
5.2.1   Description of the test location

Test location: Semi-anecholic Chamber

Test distance: 3m

5.2.2   Photo documentation of test




5.2.3   Test result

Frequency range:                         30MHz to 3180MHz

Min. limit margin:                       -2.9dB

The requirements of section 15.231(b) are FULFILLED.

Remarks:




FCC ID:KUTTM318                                                                          File No. E4064135901KY, page 12 of 16


                 emitel (Shenzhen) Limited, Building 2, 171 Meihua Road, Futian District, Shenzhen, P.R.China 518049
                                                    F10_25_Rev5_0 Freigabe: 15.03.2006


5.2.4       Test protocol

Worst Case Operation mode:                Transmitting mode                                                 Result: PASS
Remarks:
Date:                                     Dec 30, 2009
Tested by:                                Kidd Yang

 Start frequency       Stop frequency         Resolution          Vedio
                                                                                   step size     Measurement time        Detector
      [MHZ]                [MHZ]              bandwidth         bandwidth
        30                  1000               120 KHz            1 MHz              40 KHz             100ms             Peak
       1000                 3180                1 MHz            3 MHz              400 KHz             100ms             Peak

                                     Read                                                    Measured
                                                    Antenna              Cable                              PK limit        margin
 Polarization      Frequency         Value                                                     Result
                                                   Factor(dB)           Loss(dB)                           (dBuV/m)          (dB)
                     (MHz)         (dBuV/m)                                                  (dBuV/m)
        V            318.00          52.4             14.8                  1.1                 68.3            95.8        -27.5
        H            318.00           68.0            14.3                  1.1                83.4             95.8        -12.4
        H            636.00           40.8            20.5                  1.9                63.2             75.8        -12.6
        H            954.00           20.7            23.1                  2.2                46.0             75.8        -29.8
        V           1538.00           12.1            26.3                  2.9                41.3             74.0        -32.7
        V           2268.00           12.4            27.3                  3.9                43.6             74.0        -30.4
        H           2544.00           20.0            25.3                  3.1                48.4             75.8        -27.4
        H           2862.00           17.4            26.4                  3.1                46.9             74.0        -27.1

                                                   Measured             Average             Calculated
                                                                                                            AV limit        margin
 Polarization      Frequency                         Result              Factor            Average Value
                                                                                                           (dBuV/m)          (dB)
                     (MHz)         Detector        (dBuV/m)               (dB)               (dBuV/m)
        V            318.00           Peak            68.3                -10.5                57.8             75.8        -18.0
        H            318.00           Peak            83.4                -10.5                72.9             75.8         -2.9
        H            636.00           Peak            63.2                -10.5                52.7             55.8         -3.1
        H            954.00           Peak            46.0                -10.5                35.5             55.8        -20.3
        V           1538.00           Peak            41.3                -10.5                30.8             54.0        -23.2
        V           2268.00           Peak            43.6                -10.5                33.1             54.0        -20.9
        H           2544.00           Peak            48.4                -10.5                37.9             55.8        -17.9
        H           2862.00           Peak            46.9                -10.5                36.4             54.0        -17.6


Remarks:           1) The emissions lower than 20dB below the limit are not measured.

                   2) Testing is include the rotation of the EUT through three orthogonal axes to determine the

                   maximum emission.




FCC ID:KUTTM318                                                                            File No. E4064135901KY, page 13 of 16


                   emitel (Shenzhen) Limited, Building 2, 171 Meihua Road, Futian District, Shenzhen, P.R.China 518049
                                                      F10_25_Rev5_0 Freigabe: 15.03.2006


5.3     Bandwidth
5.3.1   Description of the test location

Test location: Shielded Room

5.3.2   Photo documentation of the test




5.3.3   Test result

Measured Occupied Bandwidth (kHz)            Limit (kHz)
               423                                 795


The requirements of section 15.231(c) is FULFILLED

Remarks:




FCC ID:KUTTM318                                                                         File No. E4064135901KY, page 14 of 16


                emitel (Shenzhen) Limited, Building 2, 171 Meihua Road, Futian District, Shenzhen, P.R.China 518049
                                                   F10_25_Rev5_0 Freigabe: 15.03.2006


5.4     Provision of Momentary operation
5.4.1   Description of the test location

Test location: Shielded Room

5.4.2   Photo documentation of the test




5.4.3   Test result

The time of stopping transmission after switch releasing (s)                Limit (s)
                           0.375                                                5
.
The requeirement of section 15.231(a)(1) is FULFILLED

Remarks:




FCC ID:KUTTM318                                                                          File No. E4064135901KY, page 15 of 16


                 emitel (Shenzhen) Limited, Building 2, 171 Meihua Road, Futian District, Shenzhen, P.R.China 518049
                                                    F10_25_Rev5_0 Freigabe: 15.03.2006


6      USED TEST EQUIPMENT AND ACCESSORIES
All test instruments used, in addition to the test accessories, are calibrated and verified regularly.


    Test Item           Model / Type        Kind of Equipment              Manufacturer          Last Cal. Date Equipment No.
     Radiated           ESPI3               EMI Test Receiver              Rohde & Schwarz       Apr 16, 2009 04-02/03-06-002
     Emission
                         U3772              Spectrum Analyzer             Advantest              Apr 16, 2009      04-02/11-08-001
                         3142C              Biconilog Antenna             EMCO                   Jan 08, 2009      04-02/24-06-001
                         3117               Horn Antenna                  ETS Lindgren           Feb 04, 2009      04-02/24-07-001

     Bandwidth           U3772              Spectrum Analyzer              Advantest             Apr 16, 2009      04-02/11-08-001

     Momentary           U3772              Spectrum Analyzer             Advantest              Apr 16, 2009      04-02/11-08-001
     operation

     Average Factor      U3772              Spectrum Analyzer              Advantest             Apr 16, 2009      04-02/11-08-001




FCC ID:KUTTM318                                                                          File No. E4064135901KY, page 16 of 16


                 emitel (Shenzhen) Limited, Building 2, 171 Meihua Road, Futian District, Shenzhen, P.R.China 518049
                                                    F10_25_Rev5_0 Freigabe: 15.03.2006



Document Created: 2010-03-08 16:50:21
Document Modified: 2010-03-08 16:50:21

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC