Test Report

FCC ID: KUTQS101

Test Report

Download: PDF
FCCID_819798

                                                              Capital Prospect Ltd.


                                                                   Application
                                                                        For
                                                                   Certification
                                                               (FCC ID: KUTQS101)

                                                                           Transmitter




0709746
BH/ SL
July 09, 2007


•   The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample
    may be said to have been obtained.


•   This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited.


•   For Terms And Conditions of the services, it can be provided upon request.


•   The evaluation data of the report will be kept for 3 years from the date of issuance.




                                                   Intertek Testing Services Hong Kong Ltd.
                                           2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                                  Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


                      INTERTEK TESTING SERVICES


                                LIST OF EXHIBITS

                   INTRODUCTION

                   EXHIBIT 1:             General Description

                   EXHIBIT 2:             System Test Configuration

                   EXHIBIT 3:             Emission Results

                   EXHIBIT 4:             Equipment Photographs

                   EXHIBIT 5:             Product Labelling

                   EXHIBIT 6:             Technical Specifications

                   EXHIBIT 7:             Instruction Manual

                   EXHIBIT 8:             Miscellaneous Information




FCC ID: KUTQS101
                                                                      i


                          INTERTEK TESTING SERVICES

                    MEASUREMENT/TECHNICAL REPORT

            Capital Prospect Ltd. - MODEL: QUICKSTOR QS-101

                                FCC ID: KUTQS101

                                    July 09, 2007



    This report concerns (check one:)     Original Grant X           Class II Change

    Equipment Type: Low Power Transmitter (example: computer, printer, modem, etc.)



    Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes                     No X

                                           If yes, defer until:
                                                                                date
    Company Name agrees to notify the Commission by:
                                                              date

    of the intended date of announcement of the product so that the grant can be
    issued on that date.


    Transition Rules Request per 15.37?                       Yes                 No X

    If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR
    [04-05-05 Edition] provision.


    Report prepared by:                       Ho Wai Kin, Ben
                                              Intertek Testing Services Hong Kong Ltd.
                                              2/F., Garment Center,
                                              576, Castle Peak Road,
                                              Kowloon, Hong Kong.
                                              Phone: 852-2173-8505
                                              Fax:       852-2371-0521




FCC ID: KUTQS101
                                                                                         ii


                                    INTERTEK TESTING SERVICES



                                                Table of Contents

1.0 General Description ............................................................................................ 2
  1.1 Product Description ............................................................................................ 2
  1.2 Related Submittal(s) Grants ............................................................................... 2
  1.3 Test Methodology............................................................................................... 3
  1.4 Test Facility........................................................................................................ 3

2.0 System Test Configuration ................................................................................. 5
  2.1 Justification ........................................................................................................ 5
  2.2 EUT Exercising Software.................................................................................... 5
  2.3 Special Accessories ........................................................................................... 5
  2.4 Equipment Modification ...................................................................................... 6
  2.5 Measurement Uncertainty .................................................................................. 6
  2.6 Support Equipment List and Description ............................................................. 6

3.0 Emission Results ................................................................................................ 8
  3.1 Field Strength Calculation................................................................................... 9
  3.2 Radiated Emission Configuration Photograph................................................... 10
  3.3 Radiated Emission Data ................................................................................... 11

4.0 Equipment Photographs................................................................................... 14

5.0 Product Labelling .............................................................................................. 16

6.0 Technical Specifications................................................................................... 18

7.0 Instruction Manual ............................................................................................ 20

8.0 Miscellaneous Information ............................................................................... 22
  8.1 Measured Bandwidth........................................................................................ 23
  8.2 Discussion of Pulse Desensitization.................................................................. 24
  8.3 Calculation of Average Factor........................................................................... 25
  8.4 Emissions Test Procedures .............................................................................. 26




FCC ID: KUTQS101
                                                                                                                            iii


                        INTERTEK TESTING SERVICES



                              List of attached file

      Exhibit type                File Description             filename
Test Report             Test Report                   report.pdf
Operation Description   Technical Description         descri.pdf
Test Setup Photo        Radiated Emission             radiated photos.doc
Test Report             Bandwidth Plot                bw.pdf
External Photo          External Photo                external photos.doc
Internal Photo          Internal Photo                internal photos.doc
Block Diagram           Block Diagram                 block.pdf
Schematics              Circuit Diagram               circuit.pdf
ID Label/Location       Label Artwork and Location    label.pdf
User Manual             User Manual                   manual.pdf
Test Report             Timing Diagram                timing.pdf




FCC ID: KUTQS101
                                                                            iv


                   INTERTEK TESTING SERVICES



                           EXHIBIT 1

                     GENERAL DESCRIPTION




FCC ID: KUTQS101
                                               1


                          INTERTEK TESTING SERVICES

1.0   General Description

1.1   Product Description

      The Equipment under Test (EUT) is a Transmitter operating at 319MHz. The
      EUT is powered by 12V d.c. (4 x 3V “CR2032” batteries). It is a door opening
      sensor. During normal use, it transmit control signal to the corresponding
      receiver when the door is opened. The transmitter has employed a magnetic
      switch that will cease transmission within 1.47s of being release the switch.

      Antenna Type : Internal, Integral

      For electronic filing, the brief circuit description is saved with filename: descri.pdf.


1.2   Related Submittal(s) Grants

      This is an application for certification of a transmitter. The receiver, associated
      with this transmitter, has FCC ID: B4Z-637A-REPEATER and has been granted.




FCC ID: KUTQS101
                                                                                             2


                         INTERTEK TESTING SERVICES

1.3   Test Methodology

      Radiated emission measurements were performed according to the procedures
      in ANSI C63.4 (2003). All measurements were performed in Open Area Test
      Sites. Preliminary scans were performed in the Open Area Test Sites only to
      determine worst case modes. For each scan, the procedure for maximizing
      emissions in Appendices D and E were followed. All Radiated tests were
      performed at an antenna to EUT distance of 3 meters, unless stated otherwise
      in the “Justification Section” of this Application.


1.4   Test Facility

      The open area test site and conducted measurement facility used to collect the
      emission data is located at Garment Centre, 576 Castle Peak Road, Kowloon,
      Hong Kong. This test facility and site measurement data have been fully placed
      on file with the FCC.




FCC ID: KUTQS101
                                                                                  3


                   INTERTEK TESTING SERVICES



                           EXHIBIT 2

                   SYSTEM TEST CONFIGURATION




FCC ID: KUTQS101
                                               4


                         INTERTEK TESTING SERVICES

2.0   System Test Configuration

2.1   Justification

      The system was configured for testing in a typical fashion (as a customer would
      normally use it), and in the confines as outlined in ANSI C63.4 (2003).

      The EUT was powered from 4 x new 3V "CR2032" batteries.

      For maximizing emissions, the EUT was rotated through 360°, the antenna
      height was varied from 1 meter to 4 meters above the ground plane, and the
      antenna polarization was changed. This step by step procedure for maximizing
      emissions led to the data reported in Exhibit 3.0.

      The unit was operated standalone and placed in the center of the turntable.

      The equipment under test (EUT) was configured for testing in a typical fashion
      (as a customer would normally use it). The EUT was placed on turntable, which
      enabled the engineer to maximize emissions through its placement in the three
      orthogonal axes. For simplicity of testing, the unit was wired to transmit
      continuously.

      The frequency range from 9kHz to 3.2GHz was searched for spurious emissions
      from the device. Only those emissions reported were detected. All other
      emissions were at least 20 dB below the applicable limits.


2.2   EUT Exercising Software

      There was no special software to exercise the device. Once the button is
      depressed, the unit transmits the typical signal. For simplicity of testing, the unit
      was wired to transmit continuously.


2.3   Special Accessories

      There are no special accessories necessary for compliance of this product.




FCC ID: KUTQS101
                                                                                         5


                         INTERTEK TESTING SERVICES

2.4   Equipment Modification

      Any modifications installed previous to testing by Capital Prospect Ltd. will be
      incorporated in each production model sold/leased in the United States.

      No modifications were installed by Intertek Testing Services Hong Kong Ltd.


2.5   Measurement Uncertainty

      When determining the test conclusion, the Measurement Uncertainty of test has
      been considered.


2.6   Support Equipment List and Description

      This product was tested in a standalone configuration.

      All the items listed under section 2.0 of this report are

      Confirmed by:

                    Ho Wai Kin, Ben
                    Supervisor
                    Intertek Testing Services Hong Kong Ltd.
                    Agent for Capital Prospect Ltd.




                                                         Signature

                              July 09, 2007              Date




FCC ID: KUTQS101
                                                                                    6


                   INTERTEK TESTING SERVICES



                           EXHIBIT 3

                       EMISSION RESULTS




FCC ID: KUTQS101
                                               7


                        INTERTEK TESTING SERVICES

3.0   Emission Results

      Data is included worst case configuration (the configuration which resulted in the
      highest emission levels). A sample calculation, configuration photographs and
      data tables of the emissions are included.




FCC ID: KUTQS101
                                                                                      8


                        INTERTEK TESTING SERVICES

3.1   Field Strength Calculation

      The field strength is calculated by adding the reading on the Spectrum Analyzer
      to the factors associated with preamplifiers (if any), antennas, cables, pulse
      desensitization and average factors (when specified limit is in average and
      measurements are made with peak detectors). A sample calculation is included
      below.

      FS = RA + AF + CF - AG + PD + AV

      where FS = Field Strength in dBµV/m
                  RA = Receiver Amplitude (including preamplifier) in dBµV
                  CF = Cable Attenuation Factor in dB
                  AF = Antenna Factor in dB
                  AG = Amplifier Gain in dB
                  PD = Pulse Desensitization in dB
                  AV = Average Factor in -dB

      In the radiated emission table which follows, the reading shown on the data
      table may reflect the preamplifier gain. An example of the calculations, where
      the reading does not reflect the preamplifier gain, follows:

      FS = RA + AF + CF - AG + PD + AV


      Assume a receiver reading of 62.0 dBµV is obtained. The antenna factor of 7.4 dB
      and cable factor of 1.6 dB is added. The amplifier gain of 29 dB is subtracted.
      The pulse desensitization factor of the spectrum analyzer was 0 dB, and the
      resultant average factor was -10 dB. The net field strength for comparison to
      the appropriate emission limit is 32 dBµV/m. This value in dBµV/m was converted
      to its corresponding level in µV/m.

      RA = 62.0 dBµV
      AF = 7.4 dB
      CF = 1.6 dB
      AG = 29.0 dB
      PD = 0 dB

      AV = -10 dB

      FS = 62 + 7.4 + 1.6 - 29 + 0 + (-10) = 32 dBµV/m

      Level in µV/m = Common Antilogarithm [(32 dBµV/m)/20] = 39.8 µV/m



FCC ID: KUTQS101
                                                                                    9


                        INTERTEK TESTING SERVICES

3.2   Radiated Emission Configuration Photograph

                            Worst Case Radiated Emission
                                       at
                                   2875.410 MHz


      For electronic filing, the worst case radiated emission configuration photograph
      is saved with filename: radiated photos.doc.




FCC ID: KUTQS101
                                                                                   10


                       INTERTEK TESTING SERVICES

3.3   Radiated Emission Data

      The data on the following page lists the significant emission frequencies, the
      limit and the margin of compliance. Numbers with a minus sign are below the
      limit.


                            Judgement: Passed by 9.5 dB


      TEST PERSONNEL:




      Signature



      Mark Cheung, Compliance Engineer
      Typed/Printed Name


      July 09, 2007
      Date




FCC ID: KUTQS101
                                                                                 11


                         INTERTEK TESTING SERVICES

Applicant: Capital Prospect Ltd.                              Date of Test: May 03, 2007
Model: QUICKSTOR QS-101


                                            Table 1

                                     Radiated Emissions

Polarization Frequency Reading Antenna Pre- Average  Net   Limit Margin
               (MHz)   (dBμV) Factor Amp Factor     at 3m  at 3m   (dB)
                                (dB) Gain (-dB) (dBμV/m) (dBμV/m)
                                       (dB)
     V        319.490   73.1    23.0    16   16.5   63.6   75.9   -12.3
     V        638.980   28.1    29.0    16   16.5   24.6   55.9   -31.3
     V        958.001   27.0    33.0    16   16.5   27.5   55.9   -28.4
     V       1277.960 48.3      26.1    33   16.5   24.9   55.9   -31.0
     H       1597.450* 62.7     27.2    33   16.5   40.4   54.0   -13.6
     V       1916.940 50.8      27.2    33   16.5   28.5   55.9   -27.4
     H       2236.430* 59.1     29.4    33   16.5   39.0   54.0   -15.0
     V       2555.920 58.1      30.4    33   16.5   39.0   55.9   -16.9
     V       2875.410* 63.6     30.4    33   16.5   44.5   54.0    -9.5
     V       3194.900 47.4      31.9    33   16.5   29.8   55.9   -26.1


Notes: 1. Peak Detector Data unless otherwise stated.

        2. All measurements were made at 3 meter. Harmonic emissions not detected
           at the 3-meter distance were measured at 0.3-meter and an inverse
           proportional extrapolation was performed to compare the signal level to the
           3-meter limit. No other harmonic emissions than those reported were
           detected at a test distance of 0.3-meter.

        3. Negative value in the margin column shows emission below limit.

        4. Horn antenna is used for the emission over 1000MHz.

        5. “*” Emission within the restricted band fulfil the requirement of Section 15.209.



Test Engineer: Mark Cheung




FCC ID: KUTQS101
                                                                                         12


                   INTERTEK TESTING SERVICES



                           EXHIBIT 4

                   EQUIPMENT PHOTOGRAPHS




FCC ID: KUTQS101
                                               13


                        INTERTEK TESTING SERVICES

4.0   Equipment Photographs

      For electronic filing, the photographs of the tested EUT are saved with filename:
      external photos.doc & internal photos.doc.




FCC ID: KUTQS101
                                                                                    14


                   INTERTEK TESTING SERVICES



                           EXHIBIT 5

                      PRODUCT LABELLING




FCC ID: KUTQS101
                                               15


                        INTERTEK TESTING SERVICES

5.0   Product Labelling

      For electronic filing, the FCC ID label artwork and the label location are saved
      with filename: label.pdf.




FCC ID: KUTQS101
                                                                                   16


                   INTERTEK TESTING SERVICES



                           EXHIBIT 6

                   TECHNICAL SPECIFICATIONS




FCC ID: KUTQS101
                                               17


                       INTERTEK TESTING SERVICES

6.0   Technical Specifications

      For electronic filing, the block diagram and schematics of the tested EUT are
      saved with filename: block.pdf and circuit.pdf respectively.




FCC ID: KUTQS101
                                                                                18


                   INTERTEK TESTING SERVICES



                           EXHIBIT 7

                     INSTRUCTION MANUAL




FCC ID: KUTQS101
                                               19


                        INTERTEK TESTING SERVICES

7.0   Instruction Manual

      For electronic filing, a preliminary copy of the Instruction Manual is saved with
      filename: manual.pdf.

      This manual will be provided to the end-user with each unit sold/leased in the
      United States.




FCC ID: KUTQS101
                                                                                    20


                   INTERTEK TESTING SERVICES



                           EXHIBIT 8

                   MISCELLANEOUS INFORMATION




FCC ID: KUTQS101
                                               21


                       INTERTEK TESTING SERVICES

8.0   Miscellaneous Information

      This miscellaneous information includes details of the measured bandwidth, the
      test procedure and calculation of factors such as pulse desensitization and
      averaging factor.




FCC ID: KUTQS101
                                                                                 22


                        INTERTEK TESTING SERVICES

8.1   Measured Bandwidth

      For electronic filing, the plot shows the fundamental emission when modulated
      is saved with filename: bw.pdf. From the plot, the bandwidth is observed to be
      472 kHz, at 20 dBc where the bandwidth limit is 798 kHz.

      Therefore, the unit meets the requirement of section 15.231(c).


                                Figure 8.1    Bandwidth




FCC ID: KUTQS101
                                                                                 23


                        INTERTEK TESTING SERVICES

8.2   Discussion of Pulse Desensitization

      The determination of pulse desensitivity was made in accordance with Hewlett
      Packard Application Note 150-2, Spectrum Analysis ... Pulsed RF.

      The effective period (Teff) was approximately 0.1 ms for a digital "1" bit, as
      shown in the plots of Exhibit 8.3. With a resolution bandwidth (3 dB) of 100 kHz,
      the pulse desensitivity factor was 0 dB.




FCC ID: KUTQS101
                                                                                    24


                         INTERTEK TESTING SERVICES

8.3   Calculation of Average Factor

      Averaging factor in dB = 20 log (duty cycle)

      The specification for output field strengths in accordance with the FCC rules
      specify measurements with an average detector. During testing, a spectrum
      analyzer incorporating a peak detector was used. Therefore, a reduction factor
      can be applied to the resultant peak signal level and compared to the limit for
      measurement instrumentation incorporating an average detector.

      The time period over which the duty cycle is measured is 100 milliseconds, or
      the repetition cycle, whichever is a shorter time frame. The worst case (highest
      percentage on) duty cycle is used for the calculation. The duty cycle is measured
      by placing the spectrum analyzer in zero scan (receiver mode) and linear mode
      at maximum bandwidth (3 MHz at 3 dB down) and viewing the resulting time domain
      signal output from the analyzer on a Tektronix oscilloscope. The oscilloscope is
      used because of its superior time base and triggering facilities.


      The duty cycle is simply the on-time divided by the period:

      The duration of one cycle = 100 ms
      Effective period of the cycle = 2x(1x1+1x0.65+58x0.1) ms = 14.9 ms

      DC = 14.9 ms / 100 ms = 0.149

      Therefore, the averaging factor is found by 20 log10 0.149 = -16.5 dB

      For electronic filing, the plot shows the transmission timing is saved with filename:
      timing.pdf.




FCC ID: KUTQS101
                                                                                        25


                         INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures

      The following is a description of the test procedure used by Intertek Testing Services
      in the measurements of transmitters operating under Part 15, Subpart C rules.

      The test set-up and procedures described below are designed to meet the
      requirements of ANSI C63.4 - 2003.

      The transmitting equipment under test (EUT) is placed on a wooden turntable
      which is four feet in diameter and approximately one meter in height above the
      ground plane. During the radiated emissions test, the turntable is rotated and
      any cables leaving the EUT are manipulated to find the configuration resulting in
      maximum emissions. The EUT is adjusted through all three orthogonal axes to
      obtain maximum emission levels. The antenna height and polarization are
      varied during the testing to search for maximum signal levels. The height of the
      antenna is varied from one to four meters.

      Detector function for radiated emissions is in peak mode. Average readings,
      when required, are taken by measuring the duty cycle of the equipment under
      test and subtracting the corresponding amount in dB from the measured peak
      readings. A detailed description for the calculation of the average factor can be
      found in Exhibit 8.3.

      The frequency range scanned is from the lowest radio frequency signal
      generated in the device which is greater than 9 kHz to the tenth harmonic of the
      highest fundamental frequency or 40 GHz, whichever is lower. For line
      conducted emissions, the range scanned is 150 kHz to 30 MHz.




FCC ID: KUTQS101
                                                                                         26


                         INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures (cont'd)


      The EUT is warmed up for 15 minutes prior to the test.

      AC power to the unit is varied from 85% to 115% nominal and variation in the
      fundamental emission field strength is recorded. If battery powered, a new, fully
      charged battery is used.

      Conducted measurements are made as described in ANSI C63.4 - 2003.

      The IF bandwidth used for measurement of radiated signal strength was 100 kHz
      or greater when frequency is below 1000 MHz. Where pulsed transmissions of
      short enough pulse duration warrant, a greater bandwidth is selected according
      to the recommendations of Hewlett Packard Application Note 150-2. A
      discussion of whether pulse desensitivity is applicable to this unit is included in
      this report (See Exhibit 8.2). Above 1000 MHz, a resolution bandwidth of 1 MHz
      is used.

      Transmitter measurements are normally conducted at a measurement distance
      of three meters. However, to assure low enough noise floor in the forbidden
      bands and above 1 GHz, signals are acquired at a distance of one meter or
      less. All measurements are extrapolated to three meters using inverse scaling,
      unless otherwise reported. Measurements taken at a closer distance are so
      marked.




FCC ID: KUTQS101
                                                                                      27



Document Created: 2007-07-23 10:21:31
Document Modified: 2007-07-23 10:21:31

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC