test report

FCC ID: KUJCE9201

Test Report

Download: PDF
FCCID_1222197

                                            FCC ID.KUJCE9201      Page 1 of 22




    TEST REPORT FOR FCC
 Class II PERMISSIVE CHANGE
           On Behalf of
    Chungear Industrial Co., Ltd.
Fan/Light Remote Control Transmitter
       Model No.:JY610B-L
       FCC ID:KUJCE9201




Prepared for : Chungear Industrial Co., Ltd.
               106 Kanho Rd., Taichung, Taiwan.

Prepared By : AUDIX Technology Corporation
              EMC Department
              No. 53-11, Tin-Fu Tsun, Lin-Kou Hsiang,
              Taipei Hsien, Taiwan, R.O.C.

              Tel : (02) 2609-9301, 2609-2133
              Fax : (02) 2609-9303




File Number      :   EM982506
Report Number    :   EM-F980989
Date of Test     :   Dec. 24, 2009
Date of Report   :   Dec. 30, 2009




                         AUDIX Technology Corporation   Report No.: EM-F980989


                                                                                                                     FCC ID.KUJCE9201               Page 2 of 22




                                                  TABLE OF CONTENTS


Description                                                                                                                                                  Page
TEST REPORT CERTIFICATION .......................................................................................................3
1. DESCRIPTION OF VERSION .......................................................................................................3
2. GENERAL INFORMATION..........................................................................................................5
     2.1.    Description of Device (EUT).............................................................................................................. 5
     2.2.    Description of Test Facility ................................................................................................................ 6
     2.3.    Measurement Uncertainty................................................................................................................... 6
3.   CONDUCTED EMISSION MEASUREMENT .............................................................................7
4.   RADIATED EMISSION MEASUREMENT..................................................................................8
     4.1.    Test Equipment ................................................................................................................................... 8
     4.2.    Test Setup ........................................................................................................................................... 8
     4.3.    Radiation Emission Limits (§15.209 & 15.231)................................................................................. 9
     4.4.    Operating Condition of EUT ............................................................................................................ 10
     4.5.    Test Procedure .................................................................................................................................. 10
     4.6.    Radiated Emission Measurement Results......................................................................................... 11
5.   EMISSION BANDWIDTH MEASUREMENT ...........................................................................14
     5.1.    Test Equipment ................................................................................................................................. 14
     5.2.    Block Diagram of Test Setup............................................................................................................ 14
     5.3.    Specification Limits (§15.231-(c)) ................................................................................................... 14
     5.4.    Emission Bandwidth Measurement Results...................................................................................... 14
6.   PERIODIC OPERATED MEASUREMENT................................................................................16
     6.1.    Test Equipment ................................................................................................................................. 16
     6.2.    Block Diagram of Test Setup............................................................................................................ 16
     6.3.    Specification Limits [§15.231-(a)-(1)].............................................................................................. 16
     6.4.    Periodic Operated Measurement Results .......................................................................................... 16
7.   DEVIATION TO TEST SPECIFICATIONS................................................................................18
8.   PHOTOGRAPHS ..........................................................................................................................19
     8.1.    Photos of Radiated Measurement at Semi-Anechoic Chamber (30~1000MHz) ..................................... 19
     8.2.    Photos of Radiated Measurement at Semi-Anechoic Chamber (Above 1GHz) .................................... 20
     8.3.    Photo of Emission Bandwidth Measurement.................................................................................... 22
     8.4.    Photo of Periodic Operated Measurement ........................................................................................ 22




                                                                                       AUDIX Technology Corporation                 Report No.: EM-F980989


                                                                      FCC ID.KUJCE9201     Page 3 of 22



                TEST REPORT CERTIFICATION
                   (Class II Permissive Change)

Applicant            :      Chungear Industrial Co., Ltd.
Manufacturer #1      :      Chungear Industrial Co., Ltd.
Manufacturer #2      :      Satellite Electronic (Zhongshan) Ltd.
Manufacturer #3      :      Zhongshan Amity Electronic Ltd.
EUT Description      :      Fan/Light Remote Control Transmitter
FCC ID               :      KUJCE9201
                            (A) MODEL NO.              :      JY610B-L
                            (B) SERIAL NO.             :      N/A
                            (C) POWER SUPPLY           :      DC 9V (Battery)
                            (D) TEST VOLTAGE           :      DC 9V

Measurement Procedure Used:
FCC RULES AND REGULATIONS PART 15 SUBPART C, July 2008
AND ANSI C63.4/2003

(FCC CFR 47 Part 15C, §15.207, §15.209 and §15.231)

The device described above was tested by AUDIX Technology Corporation to determine the
maximum emission levels emanating from the device. The maximum emission levels were
compared to the FCC Part 15 subpart C limits both radiated and conducted emissions.

The measurement results are contained in this test report and AUDIX Technology Corporation
is assumed full responsibility for the accuracy and completeness of these measurements. Also,
this report shows that the EUT to be technically compliant with the FCC official limits.

This report applies to above tested sample only. This report shall not be reproduced in part
without written approval of AUDIX Technology Corporation.

This report is based on report of TTEMC-F92098.

Date of Test:            Dec. 24, 2009                     Date of Report:       Dec. 30, 2009

Date of Test of Original:     May 19 ~ 20, 2003            Date of Original:      May 27, 2003


Producer :
                     (Nita Lee/Administrator)

Review:
                  (Henning Chang/Supervisor)

Signatory:
                         (Ben Cheng/Manager)


                                                  AUDIX Technology Corporation   Report No.: EM-F980989


                                                                           FCC ID.KUJCE9201      Page 4 of 22




     1. DESCRIPTION OF VERSION
Edition No.   Date of Rev.                       Summary                                  Report No.
  Rev. 0      May 27, 2003 Original Report.                                        TTEMC-F92098
  Rev. 1      Dec. 30, 2009 1. To add a new model number “JY610B-L” for            EM-F980989
                               different PCB layout. (module is same as
                               original).
                             2. To add a manufacturer “Zhongshan Amity
                                 Electronic Ltd.”
                             3. Supplementary test data are recorded in test
                                report.




                                                        AUDIX Technology Corporation   Report No.: EM-F980989


                                                              FCC ID.KUJCE9201      Page 5 of 22




2. GENERAL INFORMATION


  2.1. Description of Device (EUT)

      Description                 :     Fan/Light Remote Control Transmitter

      Model Number                :     JY610B-L

      FCC ID                      :     KUJCE9201

      Applicant                   :     Chungear Industrial Co., Ltd.

                                        160 Kanho Rd., Taichung, Taiwan, R.O.C.

      Manufacturer #1             :     Chungear Industrial Co., Ltd.

                                        160 Kanho Rd., Taichung, Taiwan, R.O.C.

      Manufacturer #2             :     Satellite Electronic (Zhongshan) Ltd.

                                        No. 15, Torch Hi-Tech Industrial Development
                                        Zone, Zhongshan City Guangdong Province
                                        China.

      Manufacturer #3             :     Zhongshan Amity Electronic Ltd.

                                        2F. No. 16, Torch Hi-Tech Industrial
                                        Development Zone, Zhongshan City Guangdong
                                        Province China.

      Fundamental Frequency       :     304MHz

      Power Supply                :     DC 9V (Battery)

      Date of Receipt of Sample   :     Dec. 07, 2009

      Date of Test                :     Dec. 24, 2009

      * Fan/Light Remote Control Transmitter - Receiver
        (1)Model No.: JY199, FCC by DoC
        (2)Model No.: JY326B, FCC by DoC
        (3)Model No.: JY326D, FCC by DoC
        (4)Model No.: MR36T, FCC by DoC
        (5)Model No.: MR36R, FCC by DoC




                                           AUDIX Technology Corporation   Report No.: EM-F980989


                                                             FCC ID.KUJCE9201      Page 6 of 22




   Remark:
   Antenna requirement: This EUT’s transmitter antenna is designed to be soldered on a
   printed circuit board, comply with §15.203 and inform to user that any change and
   modify is prohibited.

   Information for Class II Permissive Change:
   1.   This EUT is additional version with original FCC ID KUJCE9201.
   2.   The purpose of this report are (1)to add a new model number “JY610B-L” for
        different PCB layout. (module is same as original) (2)to add a manufacturer
        “Zhongshan Amity Electronic Ltd.”
   3.   This report is based on report of TTEMC-F92098.


2.2.Description of Test Facility

   Name of Firm                :      AUDIX Technology Corporation
                                      EMC Department
                                      No. 53-11, Tin-Fu Tsun, Lin-Kou Hsiang,
                                      Taipei Hsien, Taiwan.

   Test Facility & Location    :       Semi-Anechoic Chamber
                                       No. 53-11, Tin-Fu Tsun, Lin-Kou Hsiang,
                                       Taipei Hsien, Taiwan.
                                       May 16, 2006 Renewal on
                                       Federal Communication Commission
                                       Registration Number: 90993

   NVLAP Lab. Code             :      200077-0

   TAF Accreditation No        :      1724


2.3.Measurement Uncertainty
             Test Item             Frequency Range             Uncertainty (dB)

         Radiation Test            30MHz~300MHz                    ± 2.91dB
         (Distance: 3m)       300MHz~1000MHz                       ± 2.94dB
          Remark:Uncertainty = kuc(y)




                                          AUDIX Technology Corporation   Report No.: EM-F980989


                                                         FCC ID.KUJCE9201      Page 7 of 22




3. CONDUCTED EMISSION MEASUREMENT
  【The EUT only employs battery power for operation, no conductive emission
   limits are required according to FCC Part 15 Section §15.207】




                                      AUDIX Technology Corporation   Report No.: EM-F980989


                                                                 FCC ID.KUJCE9201      Page 8 of 22




4. RADIATED EMISSION MEASUREMENT

   4.1.Test Equipment
        The following test equipment was used during the radiated emission tests:
        4.1.1. For Frequency Range 30MHz~1000MHz (Semi-Anechoic Chamber)
 Item       Type       Manufacturer Model No. Serial No.              Last Cal.       Next Cal.
   1.Spectrum Analyzer     HP        8593EM 3826A00272               Jun. 26, 09’    Jun. 25, 10’
   2.Test Receiver        R&S        ESCS30    100265                Aug. 28, 09’    Aug. 27, 10’
   3.Pre-Amplifier         HP         8447D 2944A06305               Feb. 04, 09’    Feb. 03, 10’
   4.Biconical Antenna   CHASE      VBA6106A    1264                 Mar. 20, 09’    Mar. 19, 10’
   5.Log Periodic                   UHALP91                          Mar. 20, 09’    Mar. 19, 10’
                       Schwarzbeck              0810
     Antenna                           08-A
  6. Coaxial Switch      Anritsu     MP59B 6100226512                Feb. 20, 09’ Feb. 19, 10’
        4.1.2. For Frequency Range Above 1GHz (Semi-Anechoic Chamber)
 Item        Type       Manufacturer Model No. Serial No. Last Cal.   Next Cal.
   1. Spectrum Analyzer    HP        8593EM 3826A00272 Jun. 26, 09’ Jun. 25, 10’
   2. Amplifier             HP        8449B 3008A00529 Dec. 31, 08’ Dec. 30, 09’
   3. Horn Antenna        EMCO         3115    9112-3775 May 15, 09’ May 14, 10’


   4.2.Test Setup
        4.2.1. Block Diagram of connection between EUT and simulators


                        FAN/LIGHT REMOTE CONTROL
                            TRANSMITTER (EUT)




                                              AUDIX Technology Corporation   Report No.: EM-F980989


                                                                 FCC ID.KUJCE9201      Page 9 of 22




     4.2.2. Semi-Anechoic Chamber (3m) Setup Diagram

ANTENNA TOWER



                   ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS



                        3 METERS                      EUT




                                                                             80cm
                                                 TURN TABLE

                  GROUND PLANE


  4.3.Radiation Emission Limits (§15.209 & 15.231)
     4.3.1. Spurious Emission Limit (§15.209)
         FREQUENCY               DISTANCE             FIELD STRENGTHS LIMITS
             MHz                   Meters             µV/m          dBµV/m
            30 - 88                  3                 100           40.00
           88 - 216                  3                 150           43.50
           216 - 960                 3                 200           46.00
          Above 960                  3                 500           54.00
     Remarks: (1) Emission level (dBµV/m) = 20 log Emission level (µV/m)
              (2) The tighter limit applies at the edge between two frequency bands.
              (3) Distance refers to the distance in meters between the measuring instrument
                  antenna and the closed point of any part of the device or system.
     4.3.2. Fundamental Frequency Emission Limit (§15.231)
         FREQUENCY               DISTANCE             FIELD STRENGTHS LIMITS
            MHz                    Meters             µV/m           dBµV/m
     Fundamental Frequency           3                5595.3    74.95 (Quasi-Peak)
     Remarks: (1) Emission level (dBµV/m) = 20 log Emission level (µV/m)
              (2) The tighter limit applies at the edge between two frequency bands.
              (3) Distance refers to the distance in meters between the measuring instrument
                  antenna and the closed point of any part of the device or system.
              (4) Where limit of Fundamental Freq. is calculated by:
                  41.6667x304.287-7083.3333= 5595.3µV/m = 74.95 dBµV/m
              (5) The limits in this table are based on CFR 47 Part 15.231(b).




                                              AUDIX Technology Corporation   Report No.: EM-F980989


                                                             FCC ID.KUJCE9201      Page 10 of 22




4.4.Operating Condition of EUT
   4.4.1. Set up the EUT and simulator as shown on 3.2.

   4.4.2. To turn on the power of all equipment.

   4.4.3. The EUT [Fan/Light Remote Control Transmitter] emitted the fundamental
          frequency with data code at the stand, side and lying conditions. (worst mode is
          side condition)

   4.4.4. The EUT was operated on maximum transmitting status during all testing (side
          condition).


4.5.Test Procedure
   The EUT and was placed on a turn table which was 0.8 meter above the ground. The
   turn table rotated 360 degrees to determine the position of the maximum emission level.
   EUT was set to 3 meters away from the receiving antenna which was mounted on an
   antenna tower. The antenna moved up and down between 1 to 4 meters to find out
   the maximum emission level. Broadband antenna such as calibrated biconical and
   log- periodical antenna or horn antenna was used as a receiving antenna. Both
   horizontal and vertical polarization of the antenna were set on measurement. In order to
   find the maximum emission, all of the interface cables were manipulated according to
   FCC ANSI C63.4-2003 regulation.

   The bandwidth of test receiver was set at 120kHz for frequencies below 1GHz and
   resolution bandwidth of spectrum analyzer was set at 1MHz for frequencies above
   1GHz.

   The frequency range from 30MHz to 1000MHz was measured with Quasi-Peak
   detector.

   The frequency range from 1GHz to 4GHz was pre-scanned with Peak detector.

   EUT with worst positions (side) was tested during radiated measurement and all the
   test results are listed in section 4.6.




                                           AUDIX Technology Corporation   Report No.: EM-F980989


                                                                              FCC ID.KUJCE9201       Page 11 of 22




      4.6.Radiated Emission Measurement Results
          4.6.1. Frequency Range 30MHz to 1GHz Measurement Results: PASSED.
                  All the emissions not reported below are too low against the FCC part 15
                  Subpart C limit.

          Date of Test:                    Dec. 24. 2009                   Temperature:              24℃

          EUT:                     Fan/Light Remote Control                    Humidity:             48%
                                          Transmitter

          Test Mode:                                Operating (Side)

           Emission      Antenna       Cable Meter Reading Emission Level
           Frequency      Factor       Loss    Horizontal   Horizontal     Limits                Margin
             MHz          dB/m          dB       dBµV        dBµV/m       dBµV/m                  dB
------------------------------------------------------------------------------------------------------------------
    Fundamental Freq. (Quasi-Peak Value)

      Spurious / Harmonic Freq. (Quasi-Peak Value)



  *

-----------------------------------------------------------------------------------------------------------------
           Emission      Antenna       Cable Meter Reading Emission Level
           Frequency      Factor       Loss    Vertical      Vertical      Limits                Margin
             MHz          dB/m          dB       dBµV        dBµV/m       dBµV/m                  dB
------------------------------------------------------------------------------------------------------------------
    Fundamental Freq. (Quasi-Peak Value)

      Spurious / Harmonic Freq. (Quasi-Peak Value)



 *

 *
------------------------------------------------------------------------------------------------------------------
              Remarks : 1. Emission Level = Antenna Factor + Cable Loss + Meter Reading.
                        2. Measurement was up to 10th harmonics (~4.5GHz), but the emission
                           levels were too low against the official limit and not report.
                             3. "*” The field strength of emission appearing within Part 15.205(a)
                                shall not exceed the limits shown in section 15.209.




                                                          AUDIX Technology Corporation    Report No.: EM-F980989


                                                             FCC ID.KUJCE9201      Page 12 of 22




    4.6.2. Frequency Range 1GHz to 4GHz Measurement Results: PASSED.
           The frequency spectrum from 1GHz to 4GHz (up to 10th harmonics) was
           investigated. All the emissions not reported below are too low against the FCC
           part 15 Subpart C limit.

Date of Test:            Dec. 24. 2009              Temperature:             24℃

EUT:               Fan/Light Remote Control             Humidity:            48%
                          Transmitter

Test Mode:                       Operating (Side)




                                           AUDIX Technology Corporation   Report No.: EM-F980989


                    o                                        avnt rECNOLOGY Cop. ENC Labomtoy:
 4| U DIX                                                    No3%1, Tintu Trmn Linoutimng, Taipe
                                                             ComeyTawan®OC. Post Codeaiis
                                                             racsseamsmin recussassonsts
                                                             EnainencBtems comte
          a            rie—pcemoszsoniem(6)
       ar Levelaouvim)

                                                                       rec cuassanc.o
                                                                                   se


       «o   mrdfapnerpadoodonemfngrton



            zoo         ma.            azoe.             sire          arse.          sovo
                                           Frequency (iiin
Site no.      @xC Chanber                             Data no.     4
Dis. / ans.   im sus(ens)                             Ant. pol.    nontzouzan
Limie       : ree ciass—s r0—90)
Rav. / Ins.   assumw aeto/ses             Enginees                /: Jazvei Nang
sor           Fan/Zight Remote Control Transmitter
Rower mating bo ow Mioveron—s
Test wode   : cpezating (Side)

          3            rie—pcemoszsoniem(6)
       ar Tovelaouvim)


                                                                       rec cuassanc.o
                                                                                   se


       «o
            hnnesermmnestrrtrectrremnetatr




            zoo         ma.            azoe.             sire        arse.            sovo
                                           Frequency (iiin
Site no.    : CAC Chanber                             Data no. : 2
Dis. / ans.   im sus(ens)                             Ant. pot. : vermican
Limie         ree crass—s rc—mn)
Rav. / Ins.   assumw aeto/ses             Enginees /: Jazvei Nang
sor           Fan/Zight Remote Control Transmitter
Power mating be ov mnaxeros—n
Test wode     operating (@ide)



                                                      mvrrin exvarougy coporuaum. neporcions corme nozce


                                                                   FCC ID.KUJCE9201      Page 14 of 22




5. EMISSION BANDWIDTH MEASUREMENT


      5.1.Test Equipment
          The following test equipment was used during the Emission Bandwidth Test:
Item        Type         Manufacturer Model No.         Serial No.    Last Cal.    Next Cal.
  1. Spectrum Analyzer       Agilent      E4446A      US44300366     Jul. 23, 09’ Jul. 22, 10’
  2. Wide Band Antenna Diamond             RH799      2944A06305         N/A          N/A


      5.2.Block Diagram of Test Setup

    SPECTRUM                                        FAN/LIGHT REMOTE
                            ANTENNA
    ANALYZER                                      CONTROL TRANSMITTER
                                                           (EUT)



      5.3.Specification Limits (§15.231-(c))
          The bandwidth of emission shall be no wider than 0.25% of the center frequency for
          device operating above 70MHz and below 900MHz. Bandwidth is determined at the
          points 20dB down from the modulated carrier.


      5.4.Emission Bandwidth Measurement Results
          PASS.

          Fundamental Frequency: 304MHz

          Test Date: Dec. 24, 2009     Temperature: 24℃          Humidity: 48%


            No.    Center Frequency         Bandwidth            Tolerance (%)

             1.      303.7622MHz             60.5kHz                 0.0199%
          The bandwidth of emission was measured at the point 20dB down from the center
          frequency of modulated carrier.




                                                 AUDIX Technology Corporation   Report No.: EM-F980989


                                                                   FCC ID.KUJCE9201      Page 15 of 22




                   Graph of Bandwidth Measurement




Note: “š” The line is 20dB from the modulated carrier.




                                                 AUDIX Technology Corporation   Report No.: EM-F980989


                                                                     FCC ID.KUJCE9201      Page 16 of 22




6. PERIODIC OPERATED MEASUREMENT


      6.1.Test Equipment
          The following test equipment was used during the periodic operated test:
Item        Type         Manufacturer Model No.         Serial No.     Last Cal.    Next Cal.
  1. Spectrum Analyzer       Agilent      E4446A      US44300366      Jul. 23, 09’ Jul. 22, 10’
  2. Wide Band Antenna Diamond             RH799      2944A06305          N/A          N/A


      6.2.Block Diagram of Test Setup

             SPECTRUM ANALYZER                             RECEIVER ANTENNA


                   FAN/LIGHT REMOTE CONTROL TRANSMITTER (EUT)


      6.3.Specification Limits [§15.231-(a)-(1)]
          The operation of this device is manually operated transmitter that is automatically
          deactivated the transmitter within not more than 5 seconds of being released,
          Compliance with §15.231 (a)- (1).


      6.4.Periodic Operated Measurement Results
          PASS.    T = 1.925sec. (< 5sec.)

          Test Date: Dec. 24, 2009      Temperature: 24℃           Humidity: 48%

          The graph of testing is attached in next page.




                                                   AUDIX Technology Corporation   Report No.: EM-F980989


                                       FCC ID.KUJCE9201      Page 17 of 22




Graph of Periodic Operated Measurement




                     AUDIX Technology Corporation   Report No.: EM-F980989


                                            FCC ID.KUJCE9201      Page 18 of 22




7. DEVIATION TO TEST SPECIFICATIONS

  【NONE】




                          AUDIX Technology Corporation   Report No.: EM-F980989



Document Created: 2009-12-31 16:17:54
Document Modified: 2009-12-31 16:17:54

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC