Response

FCC ID: KL7-600SP-V1

Cover Letter(s)

Download: PDF
FCCID_229174

March 5, 2002

RE: Savi Technology
FCC ID: KL7-600SP-V1


After a review of your comments on the above referenced application our responses are
detailed below.

   1) Please provide better photographs of the built in antenna.
      We’ve uploaded a new jpg file. Please note that the antennas are coils wrapped
      around a core.

   2) The FCC ID given on the title page of the report does not match the FCC ID for
      this application. Please explain.
      We have uploaded a new test report

   3) The test report mentions 2 different test dates for conducted emissions, while only
      the earliest data was provided. Please explain.
      The test equipment list includes conducted emissions test equipment for the 5th
      Feb. This conducted data was for a European standard (EN 301 489-03) and so
      was not included in the report. Please advise if you want this removed from the
      report.

   4) Please explain the fact that the test report makes mention (page 6 of 10) of
      locating the radio and loop antenna at 1.77 meters high. Please note that this does
      not match the test photographs.
      Incorrect in test data. The test data has been updated to remove confusion. The
      updated data is included in the revised test report.

   5) The notes on page 8 of 10 appear to contradict the data. The data states a
      correction factor of -55.5 dB per decade was used, while the notes and the first
      paragraph state 62.1 dB was used. Please explain.
      -55.5dB was used as the worst case (lowest) extrapolation factor we calculated
      for this EUT orientation. The test data has been updated to remove confusion.
      The updated data is included in the revised test report.

   6) The notes on page 10 of 10 appear to contradict the data. The data states a
      correction factor of -65.4 dB per decade was used, while the notes state 62.1 dB
      was used. Please explain.
      -65.4dB was used as the worst-case (lowest) extrapolation factor we calculated
      for this EUT orientation. The test data has been updated to remove confusion.
      The updated data is included in the revised test report.




                                       Page 1 of 2


   7) The test report shows that the EUT was tested for radiated emissions from 30
      MHz - 1000 MHz, but the test report does not show in data in this frequency band
      (Note: EUT has 20 MHz clock). Please explain.
      This data was used for an FCC Class A digital device verification report. If
      required this report can be uploaded to ATCB.

If you have any further questions, please contact me via doc@elliottlabs.com

Regards,


Dave Guidotti




                                      Page 2 of 2