Test Report

FCC ID: KFR-ZT1101US-5

Test Report

Download: PDF
FCCID_2877179

             Compliance Certification Services Inc.                            Reference No: T120817N01-RP1
             FCC : KFR-ZT1101US-5                                       Report No.: T151215N02-RP1



      FCC 47 CFR PART 15 SUBPART C: 2014
               ANSI C63.10: 2013

                                     TEST REPORT

                                               For

                                   Z-Wave Keyfob
                                 Model: ZT1101US-5

                               Brand:

                                             Issued to

        Vision Automobile Electronics Industrial Co., Ltd.
No. 78, Gongye 3rd Rd.,Technology Industrial Park,Tainan City 70955,
                         Taiwan (R.O.C.)


                                             Issued by
               Compliance Certification Services Inc.
                             Tainan Lab.
    No.8,Jiucengling, Xinhua Dist., Tainan City 712, Taiwan (R.O.C.)
                          TEL: (06) 580-2201
                          FAX: (06) 580-2202
                   Issued Date: January 06, 2016




Note: This report shall not be reproduced except in full, without the written approval of Compliance
 Certification Services Inc. This document may be altered or revised by Compliance Certification
      Services Inc. personnel only, and shall be noted in the revision section of the document.


                                            Page 1 / 35


        Compliance Certification Services Inc.                 Reference No: T120817N01-RP1
        FCC : KFR-ZT1101US-5                           Report No.: T151215N02-RP1




                           REVISION HISTORY

Rev.     Issue Date            Revisions         Effect Page         Revised By

00     January 06, 2016        Initial Issue        ALL             Sunny Chang




                                 Page 2 / 35


                  Compliance Certification Services Inc.                                         Reference No: T120817N01-RP1
                  FCC : KFR-ZT1101US-5                                                   Report No.: T151215N02-RP1




                                        TABLE OF CONTENTS
1. TEST RESULT CERTIFICATION ........................................................................ 4

2. EUT DESCRIPTION............................................................................................. 5

3. TEST METHODOLOGY ....................................................................................... 6
  3.1   EUT CONFIGURATION .................................................................................. 6
  3.2   EUT EXERCISE .............................................................................................. 6
  3.3   GENERAL TEST PROCEDURES ................................................................... 6
  3.4   FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS ....................... 7
  3.5   DESCRIPTION OF TEST MODES .................................................................. 7

4. INSTRUMENT CALIBRATION ............................................................................ 8
  4.1 MEASURING INSTRUMENT CALIBRATION.................................................. 8
  4.2 MEASUREMENT EQUIPMENT USED............................................................ 8
  4.3 MEASUREMENT UNCERTAINTY .................................................................. 9

5. FACILITIES AND ACCREDITATIONS .............................................................. 10
  5.1   FACILITIES.................................................................................................... 10
  5.2   EQUIPMENT ................................................................................................. 10
  5.3   LABORATORY ACCREDITATIONS LISTING............................................... 10
  5.4   TABLE OF ACCREDITATIONS AND LISTINGS ........................................... 11

6. SETUP OF EQUIPMENT UNDER TEST............................................................ 12
  6.1 SETUP CONFIGURATION OF EUT.............................................................. 12
  6.2 SUPPORT EQUIPMENT ............................................................................... 12

7. FCC PART 15.249 REQUIREMENTS................................................................ 13
  7.1   20 DB BANDWIDTH ...................................................................................... 13
  7.2   BAND EDGES MEASUREMENT .................................................................. 16
  7.3   DUTY CYCLE ................................................................................................ 18
  7.4   SPURIOUS EMISSION ................................................................................. 20
  7.5   POWERLINE CONDUCTED EMISSIONS .................................................... 31

APPENDIX I - PHOTOGRAPHS OF TEST SETUP................................................. 32
APPENDIX II - PHOTOGRAPHS OF EUT ..............................................................A1




                                                       Page 3 / 35


               Compliance Certification Services Inc.                 Reference No: T120817N01-RP1
               FCC : KFR-ZT1101US-5                              Report No.: T151215N02-RP1



1. TEST RESULT CERTIFICATION
         Product: Z-Wave Keyfob

           Model: ZT1101US-5

           Brand:

       Applicant: Vision Automobile Electronics Industrial Co., Ltd.

                     No. 78, Gongye 3rd Rd.,Technology Industrial Park,Tainan City
                     70955, Taiwan (R.O.C.)

   Manufacturer: Vision Automobile Electronics Industrial Co., Ltd.

                     No. 78, Gongye 3rd Rd.,Technology Industrial Park,Tainan City
                     70955, Taiwan (R.O.C.)

          Tested: December 23, 2015 ~ December 24, 215


                             APPLICABLE STANDARDS
                 STANDARD                                  TEST RESULT

   FCC 47 CFR Part 15 Subpart C: 2014
                                                      No non-compliance noted
           ANSI C63.10: 2013



We hereby certify that:
The above equipment was tested by Compliance Certification Services Inc. The test data,
data evaluation, test procedures, and equipment configurations shown in this report
were made in accordance with the procedures given in ANSI C63.10: 2013 and the
energy emitted by the sample EUT tested as described in this report is in compliance
with the requirements emission limits of FCC Rules Part 15.107, 15.109,15.207, 15.209
and 15.249.
The test results of this report relate only to the tested sample identified in this report.


Approved by:                                    Reviewed by:




Jeter Wu                                        Eric Huang
Assistant Manager                               Assistant Section Manager




                                        Page 4 / 35


             Compliance Certification Services Inc.              Reference No: T120817N01-RP1
             FCC : KFR-ZT1101US-5                           Report No.: T151215N02-RP1




2. EUT DESCRIPTION
 Product                    Z-Wave Keyfob

 Model Number               ZT1101US-5

 Brand Name

 Received Date              December 12, 2015

 Frequency Range            908.42MHz ± 20kHz

 Transmit Peak Power        78.32 dBμV/m

 Data Rate                  9.6 kbps , 40kbps

 Number of Channels         1 Channel

 Type of Modulation         FSK

 Power Supply               DC 3.7V (Powered by Battery)

                            PCB antenna
 Antenna Type               Model: ZT1101US-5
                            Gain: -0.36 dBi

 RF Module Model            ZM5101

 Hardware Version           V1.0

 Software Version           V1.0

 Temperature Range          -15°C ~ +60°C

Remark:
1. Client consigns only one model sample to test (Model Number: ZT1101US-5).
   Therefore, the testing Lab. just guarantees the unit, which has been tested.
2. This submittal(s) (test report) is intended for FCC ID: KFR-ZT1101US-5 filing to
   comply with Section 15.107 & 15.109 (FCC Part 15, Subpart B) and Section 15.207,
   15.209, 15.249.




                                     Page 5 / 35


             Compliance Certification Services Inc.                 Reference No: T120817N01-RP1
             FCC : KFR-ZT1101US-5                             Report No.: T151215N02-RP1




3.   TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI C63.10
and FCC CFR 47 2.1046, 2.1047, 2.1049, 2.1051, 2.1053, 2.1055, 2.1057, 15.207,
15.209 and 15.249.
3.1 EUT CONFIGURATION
The EUT configuration for testing is installed on RF field strength measurement to meet
the Commissions requirement and operating in a manner that intends to maximize its
emission characteristics in a continuous normal application.
3.2 EUT EXERCISE
The EUT was operated in the engineering mode to fix the TX frequency that was for the
purpose of the measurements.
According to its specifications, the EUT must comply with the requirements of the
Section 15.107 and 15.109 under the FCC Rules Part 15 Subpart B and Section 15.207,
15.209, 15.249 under the FCC Rules Part 15 Subpart C.
3.3 GENERAL TEST PROCEDURES
Conducted Emissions
The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the
requirements in Section 13.1.4.1 of ANSI C63.10 Conducted emissions from the EUT
measured in the frequency range between 0.15 MHz and 30MHz using CISPR
Quasi-peak and average detector modes.

Radiated Emissions
The EUT is placed on a turn table, which is 0.8/1.5 m above ground plane. The turntable
shall rotate 360 degrees to determine the position of maximum emission level. EUT is
set 3m away from the receiving antenna, which varied from 1m to 4m to find out the
highest emission. And also, each emission was to be maximized by changing the
polarization of receiving antenna both horizontal and vertical. In order to find out the
maximum emissions, exploratory radiated emission measurements were made
according to the requirements in Section 13.1.4.1 of ANSI C63.10.




                                       Page 6 / 35


                 Compliance Certification Services Inc.                 Reference No: T120817N01-RP1
                 FCC : KFR-ZT1101US-5                              Report No.: T151215N02-RP1



3.4 FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS
1.   Except as shown in paragraph (d) of this section, only spurious emissions are
     permitted in any of the frequency bands listed below:

                MHz                     MHz                 MHz              GHz
             0.090 - 0.110      16.42 - 16.423     399.9 - 410            4.5 - 5.15
            1
             0.495 - 0.505   16.69475 - 16.69525    608 - 614            5.35 - 5.46
           2.1735 - 2.1905   16.80425 - 16.80475   960 - 1240            7.25 - 7.75
            4.125 - 4.128         25.5 - 25.67     1300 - 1427           8.025 - 8.5
          4.17725 - 4.17775       37.5 - 38.25    1435 - 1626.5            9.0 - 9.2
          4.20725 - 4.20775         73 - 74.6    1645.5 - 1646.5           9.3 - 9.5
            6.215 - 6.218         74.8 - 75.2      1660 - 1710           10.6 - 12.7
          6.26775 - 6.26825      108 - 121.94    1718.8 - 1722.2         13.25 - 13.4
          6.31175 - 6.31225        123 - 138       2200 - 2300           14.47 - 14.5
            8.291 - 8.294       149.9 - 150.05     2310 - 2390           15.35 - 16.2
            8.362 - 8.366        156.52475 -      2483.5 - 2500          17.7 - 21.4
          8.37625 - 8.38675        156.52525       2655 - 2900          22.01 - 23.12
          8.41425 - 8.41475      156.7 - 156.9     3260 - 3267           23.6 - 24.0
            12.29 - 12.293    162.0125 - 167.17    3332 - 3339           31.2 - 31.8
         12.51975 - 12.52025    167.72 - 173.2    3345.8 - 3358          36.43 - 36.5
         12.57675 - 12.57725       240 - 285       3600 - 4400                 ( 2)
            13.36 - 13.41         322 - 335.4
     1
         Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
     2
         Above 38.6

2.   Except as provided in paragraphs (d) and (e), the field strength of emissions
     appearing within these frequency bands shall not exceed the limits shown in Section
     15.209. At frequencies equal to or less than 1000 MHz, compliance with the limits in
     Section 15.209 shall be demonstrated using measurement instrumentation
     employing a CISPR quasi-peak detector. Above 1000 MHz, compliance with the
     emission limits in Section 15.209 shall be demonstrated based on the average value
     of the measured emissions. The provisions in Section 15.35 apply to these
     measurements.
3.5 DESCRIPTION OF TEST MODES
The EUT ( Model: ZT1101US-5 ) had been tested under engineering test mode
condition and the EUT staying in continuous transmitting mode.
Note:
The field strength of spurious emission was measured in the following position:
1) EUT has supported two data rates ( 9.6kbps , 40kbps) which have been the test. The
   worst emission was found in 40kbps and the worst case was recorded.
2) The field strength of spurious emission was measured in the following position: EUT
   stand-up position (Y axis), lie-down position (X, Z axis). The worst emission was
   found in s lie-down position (X axis) and the worst case was recorded.




                                              Page 7 / 35


              Compliance Certification Services Inc.                          Reference No: T120817N01-RP1
              FCC : KFR-ZT1101US-5                                   Report No.: T151215N02-RP1




4. INSTRUMENT CALIBRATION
4.1 MEASURING INSTRUMENT CALIBRATION
The measuring equipment, which was utilized in performing the tests documented herein,
has been calibrated in accordance with the manufacturer's recommendations for utilizing
calibration equipment, which is traceable to recognized national standards.
4.2 MEASUREMENT EQUIPMENT USED
Equipment Used for Emissions Measurement
                                   Chamber Room # 966
   Name of Equipment         Manufacturer         Model          Serial Number         Calibration Due
                                                SUCOFLEX
     HUBER+SUHNER                Cable                           SN25737 /4PEA           JAN. 14, 2016
                                                 104PEA
         Antenna             Sunol sciences         JB1              A021306             AUG. 02, 2016

     LOOP ANTENNA               EMCO               6502             8905-2356            JUN. 10, 2016

       Pre-Amplifier              HP               8447F           2443A01671            JAN. 14, 2016

       Pre-Amplifier             EMCI           EMC 012645            980098             DEC. 04, 2016

       Horn Antenna           Com-Power           AH-118              071032             JAN. 09, 2016
 3116 Double Ridge Antenna
                             ETS-LINDGREN          3116             00078900             MAR. 04, 2016
           (40G)
        Turn Table              Yo Chen             001               ----------             N.C.R.

      Antenna Tower               AR             TP1000A              309874                 N.C.R.

         Controller               UC              UC300               ----------             N.C.R.
                             E-INSTRUMENT
        RF Swicth                                ERS-180A          EC1204141                  N.C.R
                                TELH LTD

  EXA Spectrum Analyzer       KEYSIGHT            N9010A           MY54430216            JAN. 23, 2016

                                                SUCOFLEX
     HUBER+SUHNER                Cable                           SN25737 /4PEA           JAN. 14, 2016
                                                 104PEA
         Test S/W                                         e-3 (5.04303e)

Remark: Each piece of equipment is scheduled for calibration once a year.




                                          Page 8 / 35


           Compliance Certification Services Inc.                    Reference No: T120817N01-RP1
           FCC : KFR-ZT1101US-5                              Report No.: T151215N02-RP1




4.3 MEASUREMENT UNCERTAINTY
                   Parameter                            Uncertainty
      Radiated Emission, 30 to 200 MHz
                                                           ±3.21dB
                Chamber 966
     Radiated Emission, 200 to 1000 MHz
                                                           ±3.09dB
                Chamber 966
   Radiated Emission, 1 to 8 GHz                          ± 2.65dB
   Radiated Emission, 8 to 18 GHz                         ± 2.69dB
   Radiated Emission, 18 to 26.5 GHz                      ± 2.65dB
   Radiated Emission, 26 to 40 GHz                        ± 3.03dB
   Power Line Conducted Emission                          ± 1.91dB
   Uncertainty figures are valid to a confidence level of 95%, k=2




                                     Page 9 / 35


             Compliance Certification Services Inc.                   Reference No: T120817N01-RP1
             FCC : KFR-ZT1101US-5                               Report No.: T151215N02-RP1



5. FACILITIES AND ACCREDITATIONS
5.1 FACILITIES
All measurement facilities used to collect the measurement data are located at
   No.8,Jiucengling, Xinhua Dist., Tainan City 712, Taiwan (R.O.C.)
The sites are constructed in conformance with the requirements of ANSI C63.7:1992,
ANSI C63.10: 2013 and CISPR Publication 22.


5.2 EQUIPMENT
Radiated emissions are measured with one or more of the following types of linearly
polarized antennas: tuned dipole, biconical, log periodic, bi-log, and/or ridged waveguide,
horn. Spectrum analyzers with pre-selectors and quasi-peak detectors are used to
perform radiated measurements.
Conducted emissions are measured with Line Impedance Stabilization Networks and
EMI Test Receivers.
Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used
for making measurements.
All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference
Measuring Apparatus and Measurement Methods.”


5.3 LABORATORY ACCREDITATIONS LISTING
The test facilities used to perform radiated and conducted emissions tests are accredited
by Taiwan Accreditation Foundation for the specific scope of accreditation under Lab
Code: 1109 to perform Electromagnetic Interference tests according to FCC PART 15
AND CISPR 22 requirements. No part of this report may be used to claim or imply
product endorsement by TAF or any agency of the Government. In addition, the test
facilities are listed with Federal Communications Commission (registration no:
TW-1037).




                                             Page 10 / 35


             Compliance Certification Services Inc.                 Reference No: T120817N01-RP1
             FCC : KFR-ZT1101US-5                              Report No.: T151215N02-RP1




5.4 TABLE OF ACCREDITATIONS AND LISTINGS
Our laboratories are accredited and approved by the following accreditation body
according to ISO/IEC 17025.

            Taiwan            TAF


The measuring facility of laboratories has been authorized or registered by the following
approval agencies.

            Canada            Industry Canada
            Germany           TUV NORD
            Taiwan            BSMI
            USA               FCC


Copies of granted accreditation certificates are available for downloading from our web
site, http:///www.ccsrf.com




                                      Page 11 / 35


             Compliance Certification Services Inc.                  Reference No: T120817N01-RP1
             FCC : KFR-ZT1101US-5                               Report No.: T151215N02-RP1




6. SETUP OF EQUIPMENT UNDER TEST
6.1 SETUP CONFIGURATION OF EUT
See test photographs attached in Appendix I for the actual connections between EUT
and support equipment.

6.2   SUPPORT EQUIPMENT
【RF】
No.       Product      Manufacturer    Model No.     Certify No.        Signal cable

 1         N/A               ---            ---          ---                   ---

No. Signal cable description

 A               N/A                                      ---


【EMC】
No.       Product      Manufacturer    Model No.     Certify No.        Signal cable

 1         N/A               ---            ---          ---                   ---

No. Signal cable description
 A               N/A                                      ---

Remark:
1. All the equipment/cables were placed in the worst-case configuration to maximize the
   emission during the test.
2. Grounding was established in accordance with the manufacturer’s requirements and
   conditions for the intended use.

6.3 EUT OPERATING CONDITION
  RF Setup
    1. Set up a whole system as the setup diagram.
    2. Turn on power.




                                      Page 12 / 35


               Compliance Certification Services Inc.                          Reference No: T120817N01-RP1
               FCC : KFR-ZT1101US-5                                   Report No.: T151215N02-RP1



7. FCC PART 15.249 REQUIREMENTS
7.1 20 DB BANDWIDTH

LIMIT
None; for reporting purposes only.

MEASUREMENT EQUIPMENT USED

                                   Chamber Room # 966
   Name of Equipment         Manufacturer          Model          Serial Number         Calibration Due
                                                SUCOFLEX
     HUBER+SUHNER                Cable                            SN25737 /4PEA           JAN. 14, 2016
                                                 104PEA
          Antenna            Sunol sciences         JB1               A021306             AUG. 02, 2016

     LOOP ANTENNA               EMCO                6502             8905-2356            JUN. 10, 2016

        Pre-Amplifier             HP               8447F            2443A01671            JAN. 14, 2016

        Pre-Amplifier            EMCI           EMC 012645             980098             DEC. 04, 2016

        Horn Antenna          Com-Power            AH-118              071032             JAN. 09, 2016
 3116 Double Ridge Antenna
                             ETS-LINDGREN           3116             00078900             MAR. 04, 2016
           (40G)
         Turn Table             Yo Chen             001                ----------             N.C.R.

      Antenna Tower               AR              TP1000A              309874                 N.C.R.

         Controller               UC               UC300               ----------             N.C.R.
                             E-INSTRUMENT
         RF Swicth                               ERS-180A           EC1204141                  N.C.R
                                TELH LTD

  EXA Spectrum Analyzer       KEYSIGHT            N9010A            MY54430216            JAN. 23, 2016

                                                SUCOFLEX
     HUBER+SUHNER                Cable                            SN25737 /4PEA           JAN. 14, 2016
                                                 104PEA
          Test S/W                                         e-3 (5.04303e)


Remark: Each piece of equipment is scheduled for calibration once a year.




                                          Page 13 / 35


               Compliance Certification Services Inc.                  Reference No: T120817N01-RP1
               FCC : KFR-ZT1101US-5                           Report No.: T151215N02-RP1




Test Configuration


                                                             Antenna
                                                              tower


                             3m                               Bi-log
                                                             antenna
       EUT
                                   1~4m
                                                            Spectrum
                                                            analyzer


             Turntable
                            0.8m
                                          30cm

                         ▲▲▲▲▲▲▲▲


   Reference ground plane


TEST PROCEDURE
1. The EUT is placed on a turntable, which is 0.8m above ground plane.
2. The turntable shall be rotated for 360 degrees to determine the position of maximum
   emission level.
3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find
   out the highest emissions.
4. Maximum procedure was performed on the six highest emissions to ensure EUT
   compliance.
5. And also, each emission was to be maximized by changing the polarization of
   receiving antenna both horizontal and vertical.
6. Set the spectrum analyzer in the following setting as:
   RBW is set to 10 kHz and VBW is set 300kHz.




                                          Page 14 / 35


             Compliance Certification Services Inc.                     Reference No: T120817N01-RP1
             FCC : KFR-ZT1101US-5                                  Report No.: T151215N02-RP1



TEST RESULTS
No non-compliance noted.

Test Data

Tested by:         Ted Huang                          Test Date:    2015/12/23
Temperature:       27.4°C                             Humidity:     58% RH

                               Frequency                     20 dB Bandwidth
    Modulation
                                    (MHz)                            (kHz)
      40kbps                        908.42                           60.50

Test Plot

                                      40kbps Mode




                                       Page 15 / 35


                Compliance Certification Services Inc.                      Reference No: T120817N01-RP1
                FCC : KFR-ZT1101US-5                               Report No.: T151215N02-RP1




7.2 BAND EDGES MEASUREMENT
LIMIT
1. In the above emission table, the tighter limit applies at the band edges.
              Frequency                   Field Strength               Field Strength
                 (MHz)                  (μV/m at 3-meter)           (dBμV/m at 3-meter)
                 30-88                           100                           40
                88-216                           150                         43.5
                216-960                          200                           46
              Above 960                          500                           54
2. As shown in Section 15.35(b), for frequencies above 1000 MHz, the above field strength
   limits in paragraphs (a) and (b) of this section are based on average limits. However, the
   peak field strength of any emission shall not exceed the maximum permitted average
   limits specified above by more than 20 dB under any condition of modulation. For
   point-to-point operation under paragraph (b) of this section, the peak field strength shall
   not exceed 2500 millivolts/meter at 3 meters along the antenna azimuth.



TEST CONFIGURATION

                                                                  Antenna
                                                                   tower


                             3m                                    Bi-log
                                                                  antenna
        EUT
                                   1~4m
                                                                 Spectrum
                                                                 analyzer


              Turntable
                            0.8m
                                          30cm

                          ▲▲▲▲▲▲▲▲


   Reference ground plane




                                          Page 16 / 35


             Compliance Certification Services Inc.                 Reference No: T120817N01-RP1
             FCC : KFR-ZT1101US-5                             Report No.: T151215N02-RP1




TEST PROCEDURE
1. The EUT is placed on a turntable, which is 0.8m above the ground plane.
2. The turntable shall be rotated for 360 degrees to determine the position of maximum
   emission level.
3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find
   out the highest emission.
4. Set the spectrum analyzer in the following setting in order to capture the lower and
   upper band-edges of the emission:
    (a) PEAK: RBW=VBW=1MHz / Sweep=AUTO
    (b) AVERAGE: Peak Level + Duty Factor
5. Repeat the procedures until all the PEAK and AVERAGE versus polarization are
   measured.
TEST RESULTS
※ After estimate 20dB bandwidth of 1st and last channel ,the declared frequency will not
 invade restrict band. There is no requirement for this test.




                                      Page 17 / 35


                 Compliance Certification Services Inc.                     Reference No: T120817N01-RP1
                 FCC : KFR-ZT1101US-5                              Report No.: T151215N02-RP1




7.3 DUTY CYCLE

LIMIT
Nil (No dedicated limit specified in the Rules)

MEASUREMENT EQUIPMENT USED
Name of Equipment Manufacturer                 Model       Serial Number        Calibration Due
 EXA Spectrum Analyzer           KEYSIGHT      N9010A       MY54430216             JAN. 23, 2016

Remark: Each piece of equipment is scheduled for calibration once a year.

TEST CONFIGURATIONS


                                                                   Antenna
                                                                    tower


                               3m                                  Bi-log
                                                                  antenna
         EUT
                                     1~4m
                                                                 Spectrum
                                                                 analyzer


               Turntable
                              0.8m
                                            30cm

                           ▲▲▲▲▲▲▲▲


     Reference ground plane


TEST PROCEDURE
1.   Place the EUT on the table and set it in transmitting mode.
2.   Set center frequency of spectrum analyzer = operating frequency.
3.   Set the spectrum analyzer as RBW, VBW=100KHz, Span = 0Hz, a suitable Sweep
     Time.
4.   Repeat above procedures until all frequency measured were complete.

TEST RESULTS
No non-compliance noted.




                                            Page 18 / 35


             Compliance Certification Services Inc.                     Reference No: T120817N01-RP1
             FCC : KFR-ZT1101US-5                                  Report No.: T151215N02-RP1




TEST DATA
Tested by:         Ted Huang                          Test Date:    2015/12/23
Temperature:       27.4°C                             Humidity:     58% RH



                       us                Times                 Ton Total Ton time(ms)
Ton1           100000.000                    1          100000.000           100.000
Ton2                                         0               0.000
Ton3                                         0               0.000
Tp                                                                           100.000



       Ton                   100.000
   Tp(Ton+Toff)              100.000
    Duty Cycle                1.000                                100 %
   Duty Factor                0.000



TEST PLOT

Duty cycle




                                       Page 19 / 35


              Compliance Certification Services Inc.                    Reference No: T120817N01-RP1
              FCC : KFR-ZT1101US-5                                 Report No.: T151215N02-RP1




7.4 SPURIOUS EMISSION

LIMIT
1. In the section 15.249(a):
  Except as provided in paragraph (b) of this section, the field strength of emissions from
  intentional radiators operated within these frequency bands shall comply with the
  following:
                                     Field Strength of
          Fundamental                                                Field Strength of
                                       Fundamental
           Frequency                                                    Harmonics
                                      Field Strength
             (MHz)                                                        (μV/m)
                                          (mV/m)
          902-928 MHz                       50                              500
        2400 - 2483.5 MHz                    50                             500
        5725 - 5875 MHz                      50                             500
        24.0 - 24.25 GHz                      250                             2500
2. Except as provided elsewhere in this Subpart, the emissions from an intentional radiator
   shall not exceed the field strength levels specified in the following table:
             Frequency                    Field Strength            Measurement Distance
                (MHz)                         (μV/m)                            (m)
                30-88                          100*                              3
               88-216                         150*                            3
               216-960                        200*                            3
             Above 960                         500                            3
   Remark: Except as provided in paragraph (g), fundamental emissions from
   intentional radiators operating under this Section shall not be located in the frequency
   bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation
   within these frequency bands is permitted under other sections of this Part, e.g.,
   Sections 15.231 and 15.241.
3. In the above emission table, the tighter limit applies at the band edges.
             Frequency                   Field Strength                 Field Strength
               (MHz)                   (μV/m at 3-meter)             (dBμV/m at 3-meter)
               30-88                            100                           40
               88-216                          150                          43.5
               216-960                         200                            46
             Above 960                         500                            54




                                         Page 20 / 35


              Compliance Certification Services Inc.                           Reference No: T120817N01-RP1
              FCC : KFR-ZT1101US-5                                    Report No.: T151215N02-RP1




MEASUREMENT EQUIPMENT USED
                                   Chamber Room # 966
   Name of Equipment         Manufacturer          Model          Serial Number         Calibration Due
                                                SUCOFLEX
     HUBER+SUHNER                Cable                            SN25737 /4PEA           JAN. 14, 2016
                                                 104PEA
         Antenna             Sunol sciences         JB1               A021306             AUG. 02, 2016

     LOOP ANTENNA                EMCO               6502             8905-2356            JUN. 10, 2016

       Pre-Amplifier              HP               8447F            2443A01671            JAN. 14, 2016

       Pre-Amplifier             EMCI           EMC 012645             980098             DEC. 04, 2016

       Horn Antenna           Com-Power            AH-118              071032             JAN. 09, 2016
 3116 Double Ridge Antenna
                             ETS-LINDGREN           3116             00078900             MAR. 04, 2016
           (40G)
        Turn Table              Yo Chen             001                ----------             N.C.R.

      Antenna Tower               AR              TP1000A              309874                 N.C.R.

         Controller               UC               UC300               ----------             N.C.R.
                             E-INSTRUMENT
         RF Swicth                               ERS-180A           EC1204141                  N.C.R
                                TELH LTD

  EXA Spectrum Analyzer       KEYSIGHT            N9010A            MY54430216            JAN. 23, 2016

                                                SUCOFLEX
     HUBER+SUHNER                Cable                            SN25737 /4PEA           JAN. 14, 2016
                                                 104PEA
         Test S/W                                          e-3 (5.04303e)

Remark: Each piece of equipment is scheduled for calibration once a year.




                                          Page 21 / 35


              Compliance Certification Services Inc.                    Reference No: T120817N01-RP1
              FCC : KFR-ZT1101US-5                            Report No.: T151215N02-RP1



TEST CONFIGURATION
9kHz ~ 30MHz




                            3m
                                                                Loop antenna
      EUT

                                                              Spectrum /
                                                               Receiver


            Turntable                    1m
                           0.8m




  Reference ground plane



30MHz ~ 1GHz

                                                              Antenna
                                                               tower


                            3m                                 Bi-log
                                                              antenna
      EUT
                                  1~4m
                                                             Spectrum
                                                             analyzer


            Turntable
                           0.8m
                                              30cm

                        ▲▲▲▲▲▲▲▲


  Reference ground plane




                                              Page 22 / 35


               Compliance Certification Services Inc.                  Reference No: T120817N01-RP1
               FCC : KFR-ZT1101US-5                           Report No.: T151215N02-RP1



Above 1GHz


                                                             Antenna
                                                              tower


                             3m                               Bi-log
                                                             antenna
       EUT
                                   1~4m
                                                            Spectrum
                                                            analyzer


             Turntable
                            1.5m
                                          30cm

                         ▲▲▲▲▲▲▲▲


   Reference ground plane



TEST PROCEDURE
1. The EUT is placed on a turntable, which is 0.8/1.5m above ground plane.

2. The turntable shall be rotated for 360 degrees to determine the position of maximum
   emission level.

3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find
   out the highest emissions.

4. Maximum procedure was performed on the six highest emissions to ensure EUT
   compliance.

5. And also, each emission was to be maximized by changing the polarization of
   receiving antenna both horizontal and vertical.

6. Set the spectrum analyzer in the following setting as:
   Below 1GHz:
         RBW=100kHz / VBW=300kHz / Sweep=AUTO
   Above 1GHz:
         (a) PEAK: RBW=VBW=1MHz / Sweep=AUTO
         (b) AVERAGE: Peak Level + Duty Factor

7. Repeat above procedures until the measurements for all frequencies are complete.




                                          Page 23 / 35


                       Compliance Certification Services Inc.                                   Reference No: T120817N01-RP1
                       FCC : KFR-ZT1101US-5                                              Report No.: T151215N02-RP1




Below 1 GHz
Operation Mode:                     Normal Operation                                Test Date: 2015/12/24
Temperature:                        27.3°C                                          Tested by: Ted Huang
Humidity:                           52% RH                                          Polarity:     Ver. / Hor.

Vertical


       Level(dBuV/m )
 80

 70

 60

 50                                                                                                  C LASS- B
                                                                                                              -6dB
 40

 30
       1      2
                       4       5
 20                3                  6


 10

  0
      30               151                274      396         516           639          761          881           1000
                                                          Frequency(MHz)



           Freq-           Meter Reading        Antenna      Cable        Emission                               Detector
                                                                                         Limits      Margin
No.        Uency            at 3 m Level        Factor       Loss        at 3 m Level                                Mode
           (MHz)              (dBμV)            (dB/m)       (dB)         (dBμV/m)      (dBμV/m)      (dB)           PK/QP
 1         37.27                   4.37          16.63       1.87           22.86        40.00       -17.14           QP
 2         83.35               11.25             8.03        2.47           21.75        40.00       -18.25           QP
 3         110.48                  1.48          12.27       2.97           16.72        43.50       -26.78           QP
 4         139.12                  1.67          13.63       3.12           18.42        43.50       -25.08           QP
 5         197.33                  1.84          13.27       3.55           18.66        43.50       -24.84           QP
 6         241.56                  0.84          12.53       3.89           17.27        46.00       -28.73           QP
Remark:
   1.   No emission found between lowest internal used/generated frequency to 30MHz (9kHz~30MHz).
   2.   Radiated emissions measured in frequency range from 30 MHz to 1000MHz were made with an instrument
        using peak/quasi-peak detector mode.
   3.   Quasi-peak test would be performed if the peak result were greater than the quasi-peak limit or as required
        by the applicant.
   4.   Measurements above show only up to 6 maximum emissions noted, or would be lesser, with “ N/A ” remark,
        if no specific emissions from the EUT are recorded (ie: margin>20dB from the applicable limit) and
        considered that's already beyond the background noise floor.
   5.   Margin (dB) = Remark result (dBuV/m) – Quasi-peak limit (dBuV/m).
   6.   That the limit for signals below 1GHz is a QP limit and peak readings are below the QP limit.
   7.   The fundamental signal is not shown in the test data because measurements at fundamental frequency are
        shown separately and were ignored during the 30 – 1000 MHz scan.



                                                          Page 24 / 35


                        Compliance Certification Services Inc.                                Reference No: T120817N01-RP1
                        FCC : KFR-ZT1101US-5                                           Report No.: T151215N02-RP1




Operation Mode:                   Normal Operation                               Test Date: 2015/12/24
Temperature:                      27.3°C                                         Tested by: Ted Huang
Humidity:                         52% RH                                         Polarity:      Ver. / Hor.

Horizontal



       Level(dBuV/m )
 80
 70
 60
 50                                                                                                C LASS- B
                                                                                                           -6dB
 40
 30    1
                    4         5
 20            3                   6
           2

 10
  0
      30                151            274      396          516           639          761          881          1000
                                                       Frequency(MHz)



           Freq-         Meter Reading       Antenna      Cable        Emission                                Detector
                                                                                       Limits      Margin
No.        Uency          at 3 m Level       Factor        Loss       at 3 m Level                                Mode
           (MHz)              (dBμV)         (dB/m)        (dB)        (dBμV/m)      (dBμV/m)        (dB)         PK/QP
 1         39.70               8.64           14.80        1.88          25.31          40.00       -14.69         QP
 2         54.25               3.64           8.15         2.05          13.84          40.00       -26.16         QP
 3         81.27               5.33           8.10         2.40          15.83          40.00       -24.17         QP
 4         114.87              1.27           13.09        3.03          17.39          43.50       -26.11         QP
 5         199.75              2.47           13.51        3.56          19.54          43.50       -23.97         QP
 6         243.58              0.96           12.48        3.91          17.35          46.00       -28.65         QP
Remark:
    1.         No emission found between lowest internal used/generated frequency to 30MHz (9kHz~30MHz).
    2.         Radiated emissions measured in frequency range from 30 MHz to 1000MHz were made with an
               instrument using peak/quasi-peak detector mode.
      3.       Quasi-peak test would be performed if the peak result were greater than the quasi-peak limit or as
               required by the applicant.
      4.       Measurements above show only up to 6 maximum emissions noted, or would be lesser, with “ N/A ”
               remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the applicable limit) and
               considered that's already beyond the background noise floor.
      5.       Margin (dB) = Remark result (dBuV/m) – Quasi-peak limit (dBuV/m).
      6.       That the limit for signals below 1GHz is a QP limit and peak readings are below the QP limit.
      7.       The fundamental signal is not shown in the test data because measurements at fundamental frequency
               are shown separately and were ignored during the 30 – 1000 MHz scan.




                                                       Page 25 / 35


                    Compliance Certification Services Inc.                                Reference No: T120817N01-RP1
                    FCC : KFR-ZT1101US-5                                           Report No.: T151215N02-RP1




Operation Mode:                 Charger mode                                  Test Date: 2015/12/24
Temperature:                    27.3°C                                        Tested by: Ted Huang
Humidity:                       52% RH                                        Polarity:     Ver. / Hor.

Vertical


       Level(dBuV/m )
 80

 70

 60

 50                                                                                            C LASS- B
                                                                                                        -6dB
 40

 30        1
               2
                     3
 20                       4 5      6


 10

  0
      30            151             274      396         516           639          761          881           1000
                                                    Frequency(MHz)



           Freq-     Meter Reading        Antenna      Cable        Emission                               Detector
                                                                                   Limits      Margin
No.        Uency         at 3 m Level     Factor       Loss        at 3 m Level                                Mode
           (MHz)           (dBμV)         (dB/m)       (dB)         (dBμV/m)      (dBμV/m)      (dB)           PK/QP
 1         49.40            14.73          8.92        2.02           25.67        40.00       -14.33           QP

 2         68.80            11.25          8.29        2.26           21.80        40.00       -18.20           QP

 3         148.82           3.45           13.22       3.24           19.92        43.50       -23.58           QP

 4         184.25           0.77           11.98       3.53           16.28        43.50       -27.22           QP

 5         202.18           0.67           13.48       3.58           17.73        43.50       -25.77           QP

 6         253.48           0.74           12.44       3.98           17.16        46.00       -28.84           QP
Remark:
   8.   No emission found between lowest internal used/generated frequency to 30MHz (9kHz~30MHz).
   9.   Radiated emissions measured in frequency range from 30 MHz to 1000MHz were made with an instrument
        using peak/quasi-peak detector mode.
   10.  Quasi-peak test would be performed if the peak result were greater than the quasi-peak limit or as required
        by the applicant.
   11.  Measurements above show only up to 6 maximum emissions noted, or would be lesser, with “ N/A ” remark,
        if no specific emissions from the EUT are recorded (ie: margin>20dB from the applicable limit) and
        considered that's already beyond the background noise floor.
   12.  Margin (dB) = Remark result (dBuV/m) – Quasi-peak limit (dBuV/m).
   13.  That the limit for signals below 1GHz is a QP limit and peak readings are below the QP limit.
   14.  The fundamental signal is not shown in the test data because measurements at fundamental frequency are
        shown separately and were ignored during the 30 – 1000 MHz scan.



                                                    Page 26 / 35


                     Compliance Certification Services Inc.                                   Reference No: T120817N01-RP1
                     FCC : KFR-ZT1101US-5                                              Report No.: T151215N02-RP1




Operation Mode:                   Charger mode                                   Test Date: 2015/12/24
Temperature:                      27.3°C                                         Tested by: Ted Huang
Humidity:                         52% RH                                         Polarity:      Ver. / Hor.

Horizontal


       Level(dBuV/m )
 80

 70

 60

 50                                                                                                C LASS- B
                                                                                                           -6dB
 40

 30                   3

                          4
           1                  5        6
 20             2

 10

  0
      30            151               274       396          516           639          761          881          1000
                                                       Frequency(MHz)



           Freq-      Meter Reading         Antenna       Cable        Emission                                Detector
                                                                                       Limits      Margin
No.        Uency          at 3 m Level      Factor         Loss      at 3 m Level                                 Mode
           (MHz)              (dBμV)        (dB/m)         (dB)        (dBμV/m)      (dBμV/m)        (dB)         PK/QP
 1         46.97               6.84          10.38         1.98          19.21          40.00       -20.79         QP
 2         95.47               2.45          9.17          2.76          14.38          43.50       -29.12         QP
 3         146.40             11.22          13.33         3.21          27.76          43.50       -15.74         QP
 4         164.21              3.54          12.49         3.38          19.41          43.50       -24.09         QP
 5         199.75              1.28          13.51         3.56          18.35          43.50       -25.16         QP
 6         284.62              0.86          13.44         4.13          18.42          46.00       -27.58         QP
Remark:
    8.         No emission found between lowest internal used/generated frequency to 30MHz (9kHz~30MHz).
    9.         Radiated emissions measured in frequency range from 30 MHz to 1000MHz were made with an
               instrument using peak/quasi-peak detector mode.
      10.      Quasi-peak test would be performed if the peak result were greater than the quasi-peak limit or as
               required by the applicant.
      11.      Measurements above show only up to 6 maximum emissions noted, or would be lesser, with “ N/A ”
               remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the applicable limit) and
               considered that's already beyond the background noise floor.
      12.      Margin (dB) = Remark result (dBuV/m) – Quasi-peak limit (dBuV/m).
      13.      That the limit for signals below 1GHz is a QP limit and peak readings are below the QP limit.
      14.      The fundamental signal is not shown in the test data because measurements at fundamental frequency
               are shown separately and were ignored during the 30 – 1000 MHz scan.




                                                      Page 27 / 35


                Compliance Certification Services Inc.                     Reference No: T120817N01-RP1
                FCC : KFR-ZT1101US-5                                 Report No.: T151215N02-RP1




The fundamental signal

Operation Mode: TX / 40kbps Mode                               Test Date: 2015/12/23
Temperature:         27.4°C                                    Tested by: Ted Huang
Humidity:            58% RH                                    Polarity:      Ver. / Hor.


Horizontal
                              Cable
  Freq.    Reading    AF               Pre-amp   Filter    Level      Limit       Margin      Mark
                              Loss
 (MHz)     (dBμV)    (dB/m)   (dB)      (dB)     (dB)     (dBμV/m) (dBμV/m)        (dB)      (P/Q/A)

 908.42      59.76   22.10    5.95      24.41    14.92      0.00      78.32       114.00      -35.68
 908.42      59.76   22.10    5.95      24.41    14.92      0.00      78.32        94.00      -15.68


Vertical
                              Cable
  Freq.    Reading    AF               Pre-amp   Filter    Level      Limit       Margin      Mark
                              Loss
 (MHz)     (dBμV)    (dB/m)   (dB)      (dB)     (dB)     (dBμV/m)   (dBμV/m)      (dB)      (P/Q/A)
 908.42      51.97   22.10    5.95      24.41    14.92      0.00      70.53       114.00      -43.47
 908.42      51.97   22.10    5.95      24.41    14.92      0.00      70.53        94.00      -23.47

Remark:
 Margin (dB) = Remark result (dBuV/m) – Quasi-peak limit (dBuV/m).




                                           Page 28 / 35


                  Compliance Certification Services Inc.                   Reference No: T120817N01-RP1
                  FCC : KFR-ZT1101US-5                                Report No.: T151215N02-RP1



  Above 1 GHz
  Operation Mode: TX / 40kbps Mode                            Test Date: 2015/12/23
  Temperature:         27.4°C                                 Tested by: Ted Huang
  Humidity:            58% RH                                 Polarity: Ver. / Hor.

  Horizontal
                                Cable
    Freq.   Reading     AF               Pre-amp   Filter    Level     Limit    Margin       Mark
                                Loss
   (MHz)    (dBμV)     (dB/m)   (dB)      (dB)     (dB)     (dBμV/m) (dBμV/m)     (dB)      (P/Q/A)

* 2725.19      63.70   30.38    2.77      47.29    0.30      49.86     74.00     -24.14        P
* 2725.19      56.62   30.38    2.77      47.29    0.30      42.78     54.00     -11.22        A
* 4542.20      64.24   33.03    3.66      48.28    0.40      53.04     74.00     -20.96        P
* 4542.20      55.08   33.03    3.66      48.28    0.40      43.88     54.00     -10.12        A
  6358.96      66.28   36.26    4.36      47.67    0.40      59.63     74.00     -14.37        P
  6358.96      59.47   36.26    4.36      47.67    0.40      52.83     54.00     -1.17         A
* 8175.93      63.73   39.36    4.64      47.07    0.50      61.17     74.00     -12.83        P
* 8175.93      53.59   39.36    4.64      47.07    0.50      51.03     54.00     -2.97         A

  Remark:
  1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency.
  2. Radiated emissions measured in frequency above 1000MHz were made with an instrument
     using peak/average detector mode.
  3. Average test would be performed if the peak result were greater than the average limit or as
     required by the applicant.
  4. Data of measurement within this frequency range shown “ --- ” in the table above means the
     reading of emissions are attenuated more than 20dB below the permissible limits or the field
     strength is too small to be measured.
  5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with
     “ N/A ” remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the
     applicable limit) and considered that's already beyond the background noise floor.
  6. Margin (dB) = Remark result (dBuV/m) – Average limit (dBuV/m). Peak detector mode and
     average detector mode of the emission shown in Result column.




                                             Page 29 / 35


                 Compliance Certification Services Inc.                      Reference No: T120817N01-RP1
                 FCC : KFR-ZT1101US-5                                 Report No.: T151215N02-RP1




  Operation Mode: TX / 40kbps Mod                            Test Date: 2015/12/23
  Temperature:         27.4°C                                Tested by: Ted Huang
  Humidity:            58% RH                                Polarity:     Ver. / Hor.
  Vertical
                                Cable
    Freq.    Reading    AF              Pre-amp   Filter    Level        Limit     Margin      Mark
                                Loss
   (MHz)     (dBμV)    (dB/m)   (dB)     (dB)     (dB)     (dBμV/m)   (dBμV/m)      (dB)      (P/Q/A)
* 2725.26     63.38    30.38    2.77     47.29    0.30      49.54        74.00     -24.46        P
* 2725.26     52.89    30.38    2.77     47.29    0.30      39.05        54.00     -14.95        A
* 4542.06     63.76    33.03    3.66     48.28    0.40      52.56        74.00     -21.44        P
* 4542.06     54.97    33.03    3.66     48.28    0.40      43.77        54.00     -10.23        A
  6358.67     65.58    36.26    4.36     47.67    0.40      58.93        74.00     -15.07        P
  6358.67     56.35    36.26    4.36     47.67    0.40      49.71        54.00      -4.29        A
* 8175.65     64.23    39.36    4.64     47.07    0.50      61.67        74.00     -12.33        P
* 8175.65     53.28    39.36    4.64     47.07    0.50      50.72        54.00      -3.28        A

  Remark:
  1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency.
  2. Radiated emissions measured in frequency above 1000MHz were made with an instrument
     using peak/average detector mode.
  3. Average test would be performed if the peak result were greater than the average limit or as
     required by the applicant.
  4. Data of measurement within this frequency range shown “ --- ” in the table above means the
     reading of emissions are attenuated more than 20dB below the permissible limits or the field
     strength is too small to be measured.
  5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with
     “ N/A ” remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the
     applicable limit) and considered that's already beyond the background noise floor.
  6. Margin (dB) = Remark result (dBuV/m) – Average limit (dBuV/m). Peak detector mode and
     average detector mode of the emission shown in Result column.




                                            Page 30 / 35


               Compliance Certification Services Inc.                        Reference No: T120817N01-RP1
               FCC : KFR-ZT1101US-5                                     Report No.: T151215N02-RP1




7.5   POWERLINE CONDUCTED EMISSIONS

LIMIT
According to §15.207(a), except as shown in paragraphs (b) and (c) of this section, for an
intentional radiator that is designed to be connected to the public utility (AC) power line,
the radio frequency voltage that is conducted back onto the AC power line on any
frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed the limits
in the following table, as measured using a 50 µH/50 ohms line impedance stabilization
network (LISN). Compliance with the provisions of this paragraph shall be based on the
measurement of the radio frequency voltage between each power line and ground at the
power terminal. The lower limit applies at the boundary between the frequency ranges.

                                                              Limits
      Frequency Range                                        (dBμV)
           (MHz)
                                           Quasi-peak                          Average
          0.15 to 0.50                      66 to 56                           56 to 46
            0.50 to 5                         56                                  46
             5 to 30                          60                                  50
Compliance with this provision shall be based on the measurement of the radio
frequency voltage between each power line (LINE and NEUTRAL) and ground at the
power terminals.

MEASUREMENT EQUIPMENT USED
                              Conducted Emission room #1
 Name of Equipment       Manufacturer          Model         Serial Number        Calibration Due
                         SCHWARZBECK         NNLK 8130           8130124             OCT. 27, 2016
        L.I.S.N.
                         Rohde & Schwarz      ESH 3-Z5          893540/015          APR. 12, 2016

   TEST RECEIVER         Rohde & Schwarz      ESCS 30             100348            DEC. 06, 2016

 BNC COAXIAL CABLE            CCS              BNC50                 11             DEC. 04, 2016

                                                       e-3 (5.04211c)
        Test S/W
                                                        R&S (2.27)

Remark: Each piece of equipment is scheduled for calibration once a year.

TEST RESULTS
※ This EUT is not connected to AC Source directly. No applicability for this test.