   Federal Communications Commission Statement
This equipment has been followed to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
and correct the interferene by one of the following measures:
Reorient or relocate the receiving antenna,
Increase the separation between the equipment and receiver,
Connect the equipment into and outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undersired operation.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.

   Limited Warranty
Vision Guarantees that every wireless shock sensor is free from physical defects in material and
workmanship under normal use for one year from the date of purchase. If the product proves
defective during this one-year warranty period, Vision will replace it free of charge. Vision does not
issue any refunds. This warranty is extended to the original end user purchase only and is not
transferable. This warranty does not apply to : (1) damage to units caused by accident, dropping or      Installation & Operation Manual
abuse in handling, or any negligent use; (2) units which have been subject to unauthorized repair,
taken apart, or otherwise modified; (3) units not used in accordance with instruction; (4) damages
exceeding the cost of the product; (5) transit damage, initial installation costs, removal cost, or
reinstallation cost.                                                                                                ZS5101IN-5
For information on addional devices, plesae visit us at www.visionsecurity.com.tw                                   ZS5101MY-5
                                                                                                                    ZS5101EU-5
                                                                                                                    ZS5101RU-5
                                                                                                                    ZS5101US-5
                                                                                                                    ZS5101IL-5
                                                                                                                    ZS5101KR-5
                                                                                                                    ZS5101HK-5
                                                                                                                    ZS5101JP-5
                                                                                                                    ZS5101BR-5


                                                                                                              Wireless Shock Sensor


                                                     -5-

                                                             ZS 5101-5   V0    1031223    6B1Z-51002


                                                                                            Z—Wave Command Classes:
  Introduction                                                                                   COMMAND_CLASS_ASSOCIATION_GRP_INFO
                                                                                                 COMMAND_CLASS_ASSOCIATION_V2
Thanks for choosing the Vision‘s wireless shock sensor of the home security device. This         COMMAND_CLASS_BATTERY
sensor is a Z—Wave"" enabled device (interoperable, two—way RF mesh networking                   COMMAND_CLASS_DEVICE_RESET_LOCALLY
technology) and is fully compatible with any Z—Wave"* enabled network and its‘ security             COMMAND_CLASS—FIRMWARE_UPDATE_MD_V2
                                                                                                    COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
framework. Every mains powered Z—Wave enabled device acts as a signal repeater and                  COMMAND_CLASS_NOTIFICATION_V4
multiple devices result in more possible transmission routes which helps eliminate "RF              COMMAND_CLASS_POWERLEVEL
dead—spots"                                                                                         COMMAND_CALSS_SECURITY
Z—Wave"" enabled devices displaying the Z—Wave"" logo can also be used with it                      COMMAND_CLASS_VERSION_V2
regardless of the manufacturer, and ours can also be used in other manufacturer‘s                   COMMAND_CLASSWAKE_UP_V2
                                                                                                    COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Z—Wave"" enabled networks. This sensor detects the vibrations made by an intruder
trying to break a window or door, and also detect tampersituations, it will send Z—Wave"*
signal when vibrations or tampersituations are detected. When the device is secure                                                      Alarm Version 1    |Notification Version 4
included into Z—Wave network, above the communication will be encrypted.
  Product Description and Specification                                                                          Vibration detected          0x02
                                                                                                 Alarm Type
                                                                                                                   Tamper Switch             0x03
*** For indoor use only ***
                                Program /
                        Tamper Switch                                                            Alarm Level                               ON : OxPF
                                                                                                                                           OFF: 0x00
                  Sensitivity
                   djustment                                           Bracket Holder             Notification   Vibration detected                                  0x07
    LED
                                                                                                     Type          Tamper Switch                                     0x07
                                                                                                                   .   .                                          ON : 0x02
                                                                                                  Notification   |_Vibration detected                             OFF: 0x00
                                                                                                     Event                   .                                   Open:0x03
                                                                                                                   Tamper Switch                                 Glose:0x00

                                                                                                     Event       Vibration detected                                  0x02
Specification:                                    Package Content
Protocol: Z—Wave" (ZM5202)                        1pc   Z8 5101—5 Shock sensor                    Parameter        Tamper Switch                                     0x03
Frequency Range:                                  1pe   Bracket Holder                           Installation
     865.22MHz (ZS5101N—5)                        1pe   Adhesive tape for sensor            Notice: If you are installing the entire Z—Wave"*‘ system for the first time, please refer to
     868.10MHz (ZS5101MY—5                        3pc   Screw                               the installation guide of Z—Wave * Interface Controller before installing Z8 5101—5 Shock
     868.42MHz (ZS5101EU—5                        1pc    CR123A Lithium Battery             Sensor.
     869.00MHz (ZS5101RU—5                        1pc   Installation & Operation            1.    Install Battery: Use care when installing the battery. Press the locking tab on the top
     908.42MHz (2S5101US—5                               Manual                                   sensor cover, and then gently pull up the cover. Observe the correct polarity before
     916.00MHz (ZS51011L—5)                                                                       insert the battery.
     919~923MHz (ZS5101KR—5)                                                                2.    After insert the battery, the LED will start to flash slowly, which means the sensor
     919.80MHz (ZS5101HK—5)                                                                        has not yet been "inclusion"
     922~926MHz (ZS5101JP—5)                                                                3.    For "Inclusion" in (adding to) a network: Put the Z—Wave"" Interface Controller
     921.42MHz (ZS5101BR—5)                                                                       into "inclusion" mode, and following its instruction to add the Z8 5101—5 to your
Operating Range: Up to 100 feet line of sight                                                     controller. To get in the "inclusion‘ mode, the distance between sensor and
Operating Temp.: —15°C~ 60°C (5°F~140°F}                                                          controller is suggested to be in one meter. Press the program switch of Z5 5101—5
                                                                                                  for 1 second at least to be included. The LED on the ZS 5101—5 should go off, if not,
Battery: Panasonic CR123A * 1PC                                                                   please try again.

                                                                                                                                           12.


          For "Exclusion" from (removing from) a network: Put the Z—Wave"" Interface
                                                                                                   12.    Using the adhesive tape or fixing screws to fix the bracket holder with shock sensor.
          Controller into "exclusion" mode, and following its instruction to delete the ZS
          5101—5 from your controller.    Press the program switch of ZS 5101—5 for 1 second       13.     Sensitivity Adjustment:
          at least to be excluded.                                                                       To increase sensitivity, turn the adjustment clockwise.
                                                                                                         To decrease sensitivity, turn the adjustment counter—clockwise.
          For "Association" :removing the cover of the ZS 5101—5 to get into the "Awake"
          mode, then put the Z—Wave"" Interface Controller into "Association", and following                                   Use Screws                 or         Adhesive Tape
          its instruction to associate the ZS 5101 with other device. Close the cover back after
          "association" done, afterward the ZS 5101 —5 will get into "Sleep" mode for power
          saving. Support one association group (5 nodes). All triggering reports & low
          voltage report will be sent to the associated nodes.

          "Awake" mode: it is to leave the "Sleep" mode by removing the cover of ZD5101—5,
          to allow the Z—Wave"" Interface Controller to do "Inclusion", "Exclusion",
          "Association" and to reply and receive the commands from controller.

          Auto Wake Up:
          Use "Wake Up" command to set up the awaking time and send the wake up
          notification to controller. User can use command to change the auto wake up from
          500 seconds to 1 week, Interval increment is 250 seconds. (Default: 6 hours)             1.     Vibrate the ZS 5101, the sensor will send status of "ON" (Basic Set,Value:O0xFF) &
          * Use "Battery Get" command to have the battery capacity back in %                              notification report to any association nodes ; With no triggered in 10 seconds, the
                                                                                                          senor will send status of "OFF"(Basic Set,Value:0x00) & notification report to any
5.        Battery Capacity Detection:                                                                     association nodes.Normal operation, the LED will not light.
          * It will detect the battery capacity automatically                                      2.     The ZS 5101 sensor equipped with tamper switch. If the cover of sensor is removed,
          * Low Battery Auto Report (low battery is set as 2.64+/—0.1 Voltage, detects every 2            the ZS 5101 will send an notification report to the Z—Wave"? Interface Controller.
          hours)

          Power Level Control:
          Use "Power Level Set" to set up the RF strength
      *




          Use "Power Level Test Node Set" to test specific node‘s RF sensitivity
      *




          Support AES Function

          Support OTA Firmware update from controller. Please refer to your controller
          manual. Once OTA function success, please make sure to exclusive the device &
          inclusive again before use the device.

          Factory Default Reset: Push the Tamper switch then power on (put in the battery)
          & hold the Tamper switch for 5 seconds, 2ZD5101—5 will send the "Device Reset
          Locally Notification" command and reset to the factory default, LED will solid on,
          need to take off the battery and re—put in the battery to complete the function.

10. All the rest commands depend on Z—Wave standard

11.       Slide back the rear cover and screw fastening with the front cover, the LED should
          go off.