Users Manual-1

FCC ID: KFR-ZP3111US-5

Users Manual

Download: PDF
FCCID_2905251

  Federal Communications Commission Statement
This equipment has been followed to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try and
correct the interferene by one of the following measures:
-    Reorient or relocate the receiving antenna,
-    Increase the separation between the equipment and receiver,
-    Connect the equipment into and outlet on a circuit different from that to which the
     receiver is connected.
-    Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must        Installation & Operation Manual
accept any interference received, including interference that may cause undersired
operation.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this equipment.                           ZP3111IN-5
                                                                                                                ZP3111MY-5
  Limited Warranty                                                                                              ZP3111EU-5
Vision Guarantees that every wireless PIR sensor is free from physical defects in material
and workmanship under normal use for one year from the date of purchase. If the product
                                                                                                                ZP3111RU-5
proves defective during this one-year warrany period, Vision will replace it free of charge.                    ZP3111US-5
Vision does not issue any refunds. This warnnty is extended to the original end user
purchase only and is not transferable. This warranty does not apply to : (1) damage to units
                                                                                                                ZP3111IL-5
caused by accident, dropping or abuse in handling, or any negligent use; (2) units which                        ZP3111KR-5
have been subject to unauthorized repair, taken apart, or otherwise modified; (3) units not                     ZP3111HK-5
used in accordance with instruction; (4) damanges exceeding the cost of the produt; (5)
transit damage, initial installation costs, removal cost, or reinstallation cost.                               ZP3111JP-5
For information on addional devices, plesae visit us at www.visionsecurity.com.tw                               ZP3111BR-5



                                                                                                           4-in-1 Motion Sensor
                                                                                                   (Temp./Humidity/Light Sensor Built-In)



                                                    ZP 3111-5   V0 1040702 6B1Z-31003


   Introduction
Thanks for choosing the Vision’s wireless 4-in-1 Motion sensor of the home security device.
The new multi-sensor consists of motion, temperature, humidity & light sensor for combing
several functionality in one device; more attractive and economic consideration. This
                     TM
sensor is a Z-Wave       enabled device (interoperable, two-way RF mesh networking
                                                       TM
technology) and is fully compatible with any Z-Wave       enabled network and it’s security
                                             TM
framework. Every mains powered Z-Wave           enabled device acts as a signal repeater and
multiple devices result in more possible transmission routes which helps eliminate “RF
dead-spots”.
Z-Wave
         TM
            enabled device displaying the Z-Wave
                                                    TM
                                                       logo can also be used with it                  (C) - Ceiling                   (D) – Vertical              (E) - Angled
regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave
TM                                                                           TM
   enabled networks. This sensor monitors movement, and send Z-Wave              signal when
movement is detected inside the building. With Temperature sensor built inside, it will                                     (Installation for Information)
send the signal out when temperature changed. When the device is secure included into
Z-Wave network, above communication will be encrypted.                                         Specification:                                          Package Content:
  Product Description and Specification                                                        Protocol: Z-Wave™ (ZM5202)                              1pc   ZP 3111 Multi-Sensor
                                                                                               Frequency Range:
*** For indoor use only ***                                                                                                                            1pc   Adhesive tape for sensor
                                                                                                   865.22MHz (ZP3111IN-5)
                                                                                                   868.10MHz (ZP3111MY-5)                              2pc   AAA Alkaline Battery
                                                                                                   868.42MHz (ZP3111EU-5)                              1pc   Installation & Operation Manual
                                                                                                   869.00MHz (ZP3111RU-5)
                                                                                                   908.42MHz (ZP3111US-5)
                                                                                                   916.00MHz (ZP3111IL-5)
                                                                                                   919.80MHz (ZP3111HK-5)
                                                                                                   920.00MHz~923.00MHz (ZP3111KR-5)
                                                                                                   922.00MHz~926.00MHz (ZP3111JP-5)
                                                                                                   921.42MHz (ZP3111BR-5)
                                                                                               Operating Range: Up to 100 feet line of sight
                                                                                               Operating Temp.: -10°C~ 40°C (5°F~104°F)
                                                                                               Battery: AAA x 2


                                                                                               Z-Wave Command Classes:
                                                                                                  COMMAND_CLASS_ASSOCIATION_GRP_INFO
                                                                                                  COMMAND_CLASS_ASSOCIATION_V2
                                                                                                  COMMAND_CLASS_BATTERY
                                                                                                  COMMAND_CLASS_CONFIGURATION
                                                                                                  COMMAND_CLASS_DEVICE_RESET_LOCALLY
                                                                                                  COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
                                                                                                  COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
                                                                                                  COMMAND_CLASS_NOTIFICATION_V4
                                                                                                  COMMAND_CLASS_POWERLEVEL
                                                                                                  COMMAND_CLASS_SECURITY
                                                                                                  COMMAND_CLASS_SENSOR_MULTILEVEL_V7
        (A) – Wall Corner                                     (B) – Table                         COMMAND_CLASS_VERSION_V2
                                                                                                  COMMAND_CLASS_WAKE_UP_V2
                                                                                                  COMMAND_CLASS_ZWAVEPLUS_INFO_V2

                                       -1-                                                                                                     -2-


Configuration – Temperature                                                                       Installation
                                                                                             Notice: If you are installing the entire Z-Wave TM system for the first time, please refer to the
                    Size                 VALUE                   Default                     installation guide of Z-Wave TM Interface Controller before installing ZP3111.
                                   °C           0x00            °C(0x00)                     1.    Release cover tab to open the cover and insert two AAA battery into the battery
   Parameter 1        1                                                                            compartment and close the cover back to sensor.
                                   °F         0x01
                                   1~50 (Set up from                                         2.    Press the program switch, the LED will flash 5 times which means the sensor has not been
   Parameter 2        1                                           1 (°C)                           “included” yet or flash once which means the sensor has been “included” already.
                                      0.1°C~5°C)
                                                                                             3.    For “Inclusion (Auto-Inclusion)” in (adding to) a network: To add the ZP3111 to your
Configuration – Humidity                                                                           Z-Wave network (inclusion), place your Z-Wave primary controller into inclusion mode and
                                                                                                   the distance between sensor and controller is suggested to be in one meter. Press the
                                                                                                   Program Switch of ZP3111 for sending the NIF. After sending NIF, Z-Wave will send the
                   Size                 VALUE                  Default                             auto inclusion, otherwise, ZP3111 will go to sleep after 20 seconds.
                                  1~50 (Set up from                                          4.    For “Exclusion” from (removing from) a network: To remove the ZP3111 from your
   Parameter 3       1                                          10%
                                     1%~50%)                                                       Z-Wave network (exclusion), place your Z-Wave primary controller into “exclusion” mode,
                                                                                                   and following its instruction to delete the ZP3111 to your controller. Press the Program
Configuration – Light                                                                              Switch of ZP3111 once to be excluded.
                                                                                                   For “Association”: Press the program switch for sending NIF, the LED will flash once and
                                                                                                   send the Wake Up Notification in 5 seconds. Put the Z-Wave TM Interface Controller into
                   Size                 VALUE                  Default
                                                                                                   “association”, and following its instruction to associate the ZP3111 with other device.
                             0,5~50 (Set up from 0                                                 Support grouping identifier=1. Support one association group (5 nodes). “Association” is
   Parameter 4       1                                          10%
                              for Off or 5%~50%)                                                   used for other grouping devices chain reaction. Red LED will flash once when trigger.
                                                                                             5.   Auto Wake Up:
Configuration – Motion Sensor:                                                                    Use “Wake Up” command to set up the awaking time (from 10 minutes to 1 week) and send
                                                                                                  the wake up notification to controller
                              Size                                 Value                     6.   Battery Capacity Detection:
                                                    1 ~ 255 (unsigned decimal) Minutes             * Use “Battery Get” command to have the battery capacity back in %
     Parameter 5                 1                                                                 * It will detect the battery capacity automatically
                                                            (default: 3 minutes)
                                                                   1~7                             * Low Battery Auto Report when power is lower than 2.6V +/- 0.1V
     Parameter 6                 1                              (default: 4)                 7.   Temperature-If the present temperature is different with the sensor record and exceed the
                                           (Table 1)                                              setting program, the sensor will report the present temperature. LED flash every 3 minutes
                                                                                                  to represent the temperature or wake up by press the Program SW.
(Parameter 5) Re-trigger duration: User can change value from 1 to 255 minutes to setup
the re-trigger time when there is no movement detected in the period of time. Default is 3
minutes.                                                                                                      Temperature                  LED Color
(Parameter 6) Infrared sensor sensitivity adjustment, 7 levels sensitivity, 1 = most                          Under 15°C                     Green
sensitive, 7 = most insensitive, default values= 4
                                                                                                                15~23°C                       Blue
                                                                                                                23~28°C               Yellow/YellowGreen
Configuration – LED Mode:
                                                                                                                28~36°C                      Purple
                                                           Value                                               Over 36°C                      Red
                           Size
                                                     (Default: Mode 3)
                                    1 ~ 3 (Mode 1 ~ Mode 3)
                                                                                                                      Multilevel Sensor Report
                                    Mode 1  LED Turn Off (Both Temp./PIR Trigger)
    Parameter 7          1          Mode 2  Temp. (Breathing Light Mode)                                     Sensor Type                     0x01
                                                PIR (Quick Flash)                                                                          0x00 (°C)
                                                                                                                 Scale
                                    Mode 3  LED Quick Flash (Temp./PIR Trigger)                                                           0x01 (°F)
 (Caution: Mode 2 will shorten the battery life due to the Breathing Light Mode.)                          Size and Precision                    2


                                          -3-
                                                                                                                                              -4-


8. Humidity Report- If the present humidity is different with the sensor record and exceed the
setting program, the sensor will report the present humidity.                                             Operation
                                                                                                          1.   Using adhesive tape to mount ZP3111 at 2 meters above surface. To enhance proper
                         Multilevel Sensor Report                                                              operation, place ZP3111 on the location which can detect the room widely.
                 Sensor Type                      0x05
                                                                                                          2. Walk in front of ZP3111, sensor will send Basic set On (0xFF) , Red LED willl flash
                    Scale                       0x00 (%)                                                     once and please refer to status report as table below.
             Size and Precision                     2
                                                                                                          3.   If no movement detected in three minutes (default is 3 minutes - based on user’s
                                                                                                                configuration setting, refer Table 1 (Parameter 5) will send Basic Set OFF (0x00), Red
9. Light Report- If the present illumination is different with the sensor record and exceed the
                                                                                                                LED will flash once, and refer to table for status.
setting program, the sensor will report the present illumination.
                                                                                                          4.   The ZP3111 sensor equipped with tamper switch. If the tamper switch is triggered (or
                         Multilevel Sensor Report                                                              remove the cover), the ZP3111 sensor will send Alarm Report, LED will flash once and
                 Sensor Type                      0x03                                                         refer to table for status.
                    Scale                       0x00 (%)                                                  5.    If the tamper switch is closed (or closed the cover), ZP3111 will send Alarm Report,
             Size and Precision                     2                                                           and refer to table for status.

10.   Factory Default Reset: Remove cover to trigged tamper switch, LED flash once & send out
      Alarm Report. Press Program Switch 10 times within 10 seconds, ZP3111 will send the “Device                                 Alarm V1            Notification V4          Notification V4
      Reset Locally Notification” command and reset to the factory default. (Remark: This is to be used                        (Movement & Tamper
      only in the case of primary controller being inoperable or otherwise unavailable.)                                                                   (Movement)            (Tamper Switch)
                                                                                                                                      Switch)
                                                                                                               Alarm Type              0x07
                                                                                                                                0x00 (No movement
                                                                                                                                   after 3 mins)
                                                                                                               Alarm Level
                                                                                                                                   0xFF (Motion
                                                                                                                                     detected)
                                                                                                           Notification Type                                  0x07                    0x07
                                                                                                                                                          0x08(Motion
                                                                                                               Notification                                Detected)/          0x03(remove cover)/
                                                                                                                 Event                                 0x00 (no movement       0x00 (cover closed)
                                                                                                                                                          after 3 mins)


                                                                                                             Notification
                                                                                                                                                              0x08                    0x03
                                                                                                           Event Parameter



                                                                                                          6.   Support OTA Firmware update from controller. Please refer to your controller manual
                                                                                                               and use COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2. To proceed the OTA
                                                                                                               process. Once OTA function success, please make sure to exclude the device &
11.   All the rest commands depend on Z-Wave standard.                                                         include again before using the device.




                                            -5-                                                                                                           -6-



Document Created: 2015-07-03 11:14:35
Document Modified: 2015-07-03 11:14:35

© 2024 FCC.report