Test report

FCC ID: KFR-ZL7432US

Test Report

Download: PDF
FCCID_2325461

            Compliance Certification Services Inc.
                                   FCC ID: KFR-ZL7432US               Report No.: T140613N02-RP1



      FCC 47 CFR PART 15 SUBPART C: 2012
               ANSI C63.4: 2009

                                     TEST REPORT

                                               For

                           In-Wall Switch 2 Relays
                                  Model: ZL7432US
                                        Brand: N/A



                                             Issued to

         Vision Automobile Electronics Industrial Co., Ltd
No. 78, Gongye 3rd Rd., Technology Industrial Park, Tainan City 70955,
                          Taiwan (R.O.C.)


                                             Issued by
               Compliance Certification Services Inc.
                             Tainan Lab.
    No.8,Jiucengling, Xinhua Dist., Tainan City 712, Taiwan (R.O.C.)
                          TEL: (06) 580-2201
                          FAX: (06) 580-2202
                       Issued Date: July 2, 2014




Note: This report shall not be reproduced except in full, without the written approval of Compliance
 Certification Services Inc. This document may be altered or revised by Compliance Certification
      Services Inc. personnel only, and shall be noted in the revision section of the document.


                                           Page 1 / 35


       Compliance Certification Services Inc.
                           FCC ID: KFR-ZL7432US      Report No.: T140613N02-RP1



                          REVISION HISTORY

Rev.    Issue Date           Revisions          Effect Page    Revised By

00     July 2, 2014          Initial Issue         ALL           Eva Lin




                                Page 2 / 35


                 Compliance Certification Services Inc.
                                                FCC ID: KFR-ZL7432US                  Report No.: T140613N02-RP1



                                      TABLE OF CONTENTS


1. TEST RESULT CERTIFICATION .........................................................................4

2. EUT DESCRIPTION..............................................................................................5

3. TEST METHODOLOGY........................................................................................6
  3.1   EUT CONFIGURATION ...................................................................................6
  3.2   EUT EXERCISE ...............................................................................................6
  3.3   GENERAL TEST PROCEDURES....................................................................6
  3.4   FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS ........................7
  3.5   DESCRIPTION OF TEST MODES...................................................................7

4. INSTRUMENT CALIBRATION .............................................................................8
  4.1 MEASURING INSTRUMENT CALIBRATION ..................................................8
  4.2 MEASUREMENT EQUIPMENT USED ............................................................8
  4.3 MEASUREMENT UNCERTAINTY ...................................................................9

5. FACILITIES AND ACCREDITATIONS ...............................................................10
  5.1   FACILITIES ....................................................................................................10
  5.2   EQUIPMENT ..................................................................................................10
  5.3   LABORATORY ACCREDITATIONS LISTING ...............................................10
  5.4   TABLE OF ACCREDITATIONS AND LISTINGS............................................11

6. SETUP OF EQUIPMENT UNDER TEST ............................................................12
  6.1 SETUP CONFIGURATION OF EUT ..............................................................12
  6.2 SUPPORT EQUIPMENT................................................................................12

7. FCC PART 15.249 REQUIREMENTS ................................................................13
  7.1   20 DB BANDWIDTH.......................................................................................13
  7.2   BAND EDGES MEASUREMENT ...................................................................16
  7.3   DUTY CYCLE.................................................................................................17
  7.4   SPURIOUS EMISSION ..................................................................................20
  7.5   POWERLINE CONDUCTED EMISSIONS .....................................................29

APPENDIX I - PHOTOGRAPHS OF TEST SETUP .................................................32
APPENDIX II - PHOTOGRAPHS OF EUT .............................................................. A1




                                                       Page 3 / 35


               Compliance Certification Services Inc.
                                   FCC ID: KFR-ZL7432US        Report No.: T140613N02-RP1



1. TEST RESULT CERTIFICATION
         Product: In-Wall Switch 2 Relays

           Model: ZL7432US

           Brand: N/A

       Applicant: Vision Automobile Electronics Industrial Co., Ltd.

                     No. 78, Gongye 3rd Rd., Technology Industrial Park, Tainan City
                     70955, Taiwan (R.O.C.)

   Manufacturer: Vision Automobile Electronics Industrial Co., Ltd.

                     No. 78, Gongye 3rd Rd., Technology Industrial Park, Tainan City
                     70955, Taiwan (R.O.C.)

          Tested: June 16, 2014 ~ June 26, 2014


                             APPLICABLE STANDARDS
                  STANDARD                                 TEST RESULT

   FCC 47 CFR Part 15 Subpart C: 2012
                                                      No non-compliance noted
           ANSI C63.4 : 2009



We hereby certify that:
The above equipment was tested by Compliance Certification Services Inc. The test data,
data evaluation, test procedures, and equipment configurations shown in this report
were made in accordance with the procedures given in ANSI C63.4: 2009 and the
energy emitted by the sample EUT tested as described in this report is in compliance
with the requirements emission limits of FCC Rules Part 15.107, 15.109,15.207, 15.209
and 15.249.
The test results of this report relate only to the tested sample identified in this report.




Approved by:                                    Reviewed by:




Jeter Wu                                        Eric Huang
Assistant Manager                               Assistant Section Manager




                                        Page 4 / 35


             Compliance Certification Services Inc.
                                  FCC ID: KFR-ZL7432US      Report No.: T140613N02-RP1



2. EUT DESCRIPTION
 Product                    In-Wall Switch 2 Relays

 Model Number               ZL7432US

 Brand                      N/A

 Received Date              June 13, 2014

 Frequency Range            908.42MHz ± 20KHz

 Transmit Peak Power        91.21 dBμV/m

 Data Rate                  9.6 kbps , 40kbps

 Number of Channels         1 Channel

 Type of Modulation         FSK

 Power Supply               AC 120V

                            Wire antenna
 Antenna Type               Model: ZL7432US
                            Gain: -13 dBi

 Temperature Range          -15°C ~ +60°C

Remark:
1. Client consigns only one model sample to test (Model Number: ZL7432US). Therefore,
   the testing Lab. just guarantees the unit, which has been tested.
2. This submittal(s) (test report) is intended for FCC ID: KFR-ZL7432US filing to comply
   with Section 15.107 & 15.109 (FCC Part 15, Subpart B) and Section 15.207, 15.209,
   15.249.




                                        Page 5 / 35


             Compliance Certification Services Inc.
                                   FCC ID: KFR-ZL7432US       Report No.: T140613N02-RP1



3.    TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI C63.4 and
FCC CFR 47 2.1046, 2.1047, 2.1049, 2.1051, 2.1053, 2.1055, 2.1057, 15.207, 15.209
and 15.249.
3.1 EUT CONFIGURATION
The EUT configuration for testing is installed on RF field strength measurement to meet
the Commissions requirement and operating in a manner that intends to maximize its
emission characteristics in a continuous normal application.
3.2 EUT EXERCISE
The EUT was operated in the engineering mode to fix the TX frequency that was for the
purpose of the measurements.
According to its specifications, the EUT must comply with the requirements of the
Section 15.107 and 15.109 under the FCC Rules Part 15 Subpart B and Section 15.207,
15.209,15.249 under the FCC Rules Part 15 Subpart C.
3.3 GENERAL TEST PROCEDURES
Conducted Emissions
The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the
requirements in Section 13.1.4.1 of ANSI C63.4 Conducted emissions from the EUT
measured in the frequency range between 0.15 MHz and 30MHz using CISPR
Quasi-peak and average detector modes.

Radiated Emissions
The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable
shall rotate 360 degrees to determine the position of maximum emission level. EUT is
set 3m away from the receiving antenna, which varied from 1m to 4m to find out the
highest emission. And also, each emission was to be maximized by changing the
polarization of receiving antenna both horizontal and vertical. In order to find out the
maximum emissions, exploratory radiated emission measurements were made
according to the requirements in Section 13.1.4.1 of ANSI C63.4.




                                        Page 6 / 35


                 Compliance Certification Services Inc.
                                      FCC ID: KFR-ZL7432US       Report No.: T140613N02-RP1



3.4 FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS
1.   Except as shown in paragraph (d) of this section, only spurious emissions are
     permitted in any of the frequency bands listed below:

                MHz                   MHz                  MHz               GHz
             0.090 - 0.110      16.42 - 16.423     399.9 - 410            4.5 - 5.15
            1
             0.495 - 0.505   16.69475 - 16.69525    608 - 614            5.35 - 5.46
           2.1735 - 2.1905   16.80425 - 16.80475   960 - 1240            7.25 - 7.75
            4.125 - 4.128         25.5 - 25.67     1300 - 1427           8.025 - 8.5
          4.17725 - 4.17775       37.5 - 38.25    1435 - 1626.5            9.0 - 9.2
          4.20725 - 4.20775         73 - 74.6    1645.5 - 1646.5           9.3 - 9.5
            6.215 - 6.218         74.8 - 75.2      1660 - 1710           10.6 - 12.7
          6.26775 - 6.26825      108 - 121.94    1718.8 - 1722.2         13.25 - 13.4
          6.31175 - 6.31225        123 - 138       2200 - 2300           14.47 - 14.5
            8.291 - 8.294       149.9 - 150.05     2310 - 2390           15.35 - 16.2
            8.362 - 8.366        156.52475 -      2483.5 - 2500          17.7 - 21.4
          8.37625 - 8.38675        156.52525       2655 - 2900          22.01 - 23.12
          8.41425 - 8.41475      156.7 - 156.9     3260 - 3267           23.6 - 24.0
            12.29 - 12.293    162.0125 - 167.17    3332 - 3339           31.2 - 31.8
         12.51975 - 12.52025    167.72 - 173.2    3345.8 - 3358          36.43 - 36.5
         12.57675 - 12.57725       240 - 285       3600 - 4400                 ( 2)
            13.36 - 13.41         322 - 335.4
     1
         Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
     2
         Above 38.6

2.   Except as provided in paragraphs (d) and (e), the field strength of emissions
     appearing within these frequency bands shall not exceed the limits shown in Section
     15.209. At frequencies equal to or less than 1000 MHz, compliance with the limits in
     Section 15.209 shall be demonstrated using measurement instrumentation
     employing a CISPR quasi-peak detector. Above 1000 MHz, compliance with the
     emission limits in Section 15.209 shall be demonstrated based on the average value
     of the measured emissions. The provisions in Section 15.35 apply to these
     measurements.
3.5 DESCRIPTION OF TEST MODES
The EUT( Model: ZL7432US ) had been tested under engineering test mode condition
and the EUT staying in continuous transmitting mode.
Note:
1) EUT has supported two data rates (4.8kbps; 9.6kbps ) which have been investigated
   during the test, and found the 9.6kbps as the worst case recorded.
2) The field strength of spurious emission was measured in the following position: EUT
   stand-up position (Y axis), lie-down position (X, Z axis). The worst emission was
   found in s lie-down position (Z axis) and the worst case was recorded.




                                            Page 7 / 35


              Compliance Certification Services Inc.
                                    FCC ID: KFR-ZL7432US     Report No.: T140613N02-RP1



4. INSTRUMENT CALIBRATION
4.1 MEASURING INSTRUMENT CALIBRATION
The measuring equipment, which was utilized in performing the tests documented herein,
has been calibrated in accordance with the manufacturer's recommendations for utilizing
calibration equipment, which is traceable to recognized national standards.
4.2 MEASUREMENT EQUIPMENT USED
Equipment Used for Emissions Measurement
                                 Open Area Test Site # 6
   Name of Equipment         Manufacturer         Model     Serial Number   Calibration Due

 TYPE N COAXIAL CABLE          SUHNER            CHA9513           6         DEC. 18, 2014

      BI-LOG Antenna            Sunol               JB1       A070506-2      SEP. 26, 2014

     LOOP ANTENNA               EMCO               6502       8905-2356      JUN. 10, 2015

       Pre-Amplifier             HP                8447F        NCR              NCR

       EMI Receiver              R&S              ESVS10     833206/012      JUN. 26, 2015
                                             SUCOFLEX104P
         RF Cable              SUHNER                        20520/4PEA      NOV. 10, 2014
                                                  EA
       Horn Antenna           Com-Power           AH-118       071032        DEC. 05, 2014
 3116 Double Ridge Antenna
                             ETS-LINDGREN          3116       00078900       DEC. 27, 2014
           (40G)
        Turn Table             Yo Chen              001        ----------       N.C.R.

      Antenna Tower              AR              TP1000A       309874           N.C.R.

         Controller              CT               SC101        ----------       N.C.R.
                             E-INSTRUMENT
        RF Swicth                                ERS-180A    EC1204141          N.C.R
                                TELH LTD

       Power Meter              Anritsu          ML2487A     6K00003888      MAY. 20, 2015

       Power Sensor             Anritsu          MA2491A        33265        MAY. 20, 2015

  Temp./Humidity Chamber        K.SON             THS-M1         242         AUG. 08, 2014

     DC Power Source            LOKO             DSP-5050    L1507009282        N.C.R

     Spectrum Analyzer           R&S                FSU        200789        JUL. 01, 2015

     Spectrum Analyzer           R&S             FSEK 30     835253/002      SEP. 28, 2014

Remark: Each piece of equipment is scheduled for calibration once a year.




                                          Page 8 / 35


          Compliance Certification Services Inc.
                                 FCC ID: KFR-ZL7432US      Report No.: T140613N02-RP1



4.3 MEASUREMENT UNCERTAINTY
                   Parameter                            Uncertainty
       Radiated Emission, 30 to 200 MHz
                                                         ±3.3456dB
              Test Site : OATS-6
      Radiated Emission, 200 to 1000 MHz
                                                         ±2.6828dB
              Test Site : OATS-6
        Radiated Emission, 1 to 8 GHz                   ± 2.6485dB
        Radiated Emission, 8 to 18 GHz                  ± 2.6852dB
         Radiated Emission, 18 to 26.5 GHz               ± 2.6485dB
         Radiated Emission, 26 to 40 GHz                 ± 3.0295dB
        Power Line Conducted Emission                     ±1.91dB
                    Band Width                           136.49kHz
              Peak Output Power MU                       ±1.904dB
                  Band Edge MU                          ±0.302dBuV
             Channel Separation MU                        361.69Hz
                  Duty Cycle MU                           0.064ms
              Frequency Stability MU                      0.223kHz
   Uncertainty figures are valid to a confidence level of 95%, k=2




                                     Page 9 / 35


             Compliance Certification Services Inc.
                                 FCC ID: KFR-ZL7432US         Report No.: T140613N02-RP1



5. FACILITIES AND ACCREDITATIONS
5.1 FACILITIES
All measurement facilities used to collect the measurement data are located at
   No.8,Jiucengling, Xinhua Dist., Tainan City 712, Taiwan (R.O.C.)
The sites are constructed in conformance with the requirements of ANSI C63.7:1992,
ANSI C63.4 : 2009 and CISPR Publication 22.


5.2 EQUIPMENT
Radiated emissions are measured with one or more of the following types of linearly
polarized antennas: tuned dipole, biconical, log periodic, bi-log, and/or ridged waveguide,
horn. Spectrum analyzers with pre-selectors and quasi-peak detectors are used to
perform radiated measurements.
Conducted emissions are measured with Line Impedance Stabilization Networks and
EMI Test Receivers.
Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used
for making measurements.
All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference
Measuring Apparatus and Measurement Methods.”


5.3 LABORATORY ACCREDITATIONS LISTING
The test facilities used to perform radiated and conducted emissions tests are accredited
by Taiwan Accreditation Foundation for the specific scope of accreditation under Lab
Code: 1109 to perform Electromagnetic Interference tests according to FCC PART 15
AND CISPR 22 requirements. No part of this report may be used to claim or imply
product endorsement by TAF or any agency of the Government. In addition, the test
facilities are listed with Federal Communications Commission (registration no:
TW-1037).




                                             Page 10 / 35


             Compliance Certification Services Inc.
                                    FCC ID: KFR-ZL7432US     Report No.: T140613N02-RP1



5.4 TABLE OF ACCREDITATIONS AND LISTINGS
Our laboratories are accredited and approved by the following accreditation body
according to ISO/IEC 17025.

            Taiwan            TAF


The measuring facility of laboratories has been authorized or registered by the following
approval agencies.

            Canada            Industry Canada
            Germany           TUV NORD
            Taiwan            BSMI
            USA               FCC


Copies of granted accreditation certificates are available for downloading from our web
site, http:///www.ccsrf.com




                                       Page 11 / 35


             Compliance Certification Services Inc.
                                    FCC ID: KFR-ZL7432US           Report No.: T140613N02-RP1



6. SETUP OF EQUIPMENT UNDER TEST
6.1 SETUP CONFIGURATION OF EUT
See test photographs attached in Appendix I for the actual connections between EUT
and support equipment.

6.2   SUPPORT EQUIPMENT
【RF】
                                                       Certify
No.       Product      Manufacturer       Model No.                        Signal cable
                                                        No.
 1         N/A               ---              ---            ---                 ---

No. Signal cable description

 A    AC Power Cable               Unshielded, 1.2m, 1pcs.



【EMC】
                                                       Certify
No.       Product      Manufacturer       Model No.                        Signal cable
                                                        No.
 1         Load             N/A               ---            ---                 ---


No. Signal cable description

 A    AC Input Cable               Unshielded, 1.8m, 1pcs.

 B    AC Output Cable              Unshielded, 0.2m, 1pcs.

Remark:
1. All the equipment/cables were placed in the worst-case configuration to maximize the
   emission during the test.
2. Grounding was established in accordance with the manufacturer’s requirements and
   conditions for the intended use.



6.3 EUT OPERATING CONDITION
  RF Setup
    1. Set up a whole system as the setup diagram.
    2. Turn on power.




                                        Page 12 / 35


              Compliance Certification Services Inc.
                                     FCC ID: KFR-ZL7432US     Report No.: T140613N02-RP1



7. FCC PART 15.249 REQUIREMENTS
7.1 20 DB BANDWIDTH

LIMIT
None; for reporting purposes only.

MEASUREMENT EQUIPMENT USED

                                 Open Area Test Site # 6
   Name of Equipment         Manufacturer          Model     Serial Number   Calibration Due

 TYPE N COAXIAL CABLE          SUHNER             CHA9513           6         DEC. 18, 2014

      BI-LOG Antenna            Sunol               JB1        A070506-2      SEP. 26, 2014

     LOOP ANTENNA               EMCO                6502       8905-2356      JUN. 10, 2015

        Pre-Amplifier            HP                8447F         NCR              NCR

        EMI Receiver             R&S              ESVS10      833206/012      JUN. 26, 2015
                                              SUCOFLEX104P
         RF Cable              SUHNER                         20520/4PEA      NOV. 10, 2014
                                                   EA
        Horn Antenna          Com-Power            AH-118       071032        DEC. 05, 2014
 3116 Double Ridge Antenna
                             ETS-LINDGREN           3116       00078900       DEC. 27, 2014
           (40G)

         Turn Table            Yo Chen              001         ----------       N.C.R.

      Antenna Tower              AR               TP1000A       309874           N.C.R.

         Controller              CT                SC101        ----------       N.C.R.

                             E-INSTRUMENT
         RF Swicth                               ERS-180A     EC1204141          N.C.R
                                TELH LTD

        Power Meter             Anritsu           ML2487A     6K00003888      MAY. 20, 2015

       Power Sensor             Anritsu          MA2491A         33265        MAY. 20, 2015

  Temp./Humidity Chamber        K.SON             THS-M1          242         AUG. 08, 2014

     DC Power Source            LOKO             DSP-5050     L1507009282        N.C.R

     Spectrum Analyzer           R&S                FSU         200789        JUL. 01, 2015

     Spectrum Analyzer           R&S              FSEK 30     835253/002      SEP. 28, 2014

Remark: Each piece of equipment is scheduled for calibration once a year.




                                          Page 13 / 35


              Compliance Certification Services Inc.
                                             FCC ID: KFR-ZL7432US    Report No.: T140613N02-RP1




Test Configuration


                                                                       Antenna
                                                                        tower


                             3m                                         Bi-log
                                                                       antenna
       EUT
                                   4m
                                                                      Spectrum
                                                                      analyzer


             Turntable                  1m
                            0.8m




   Reference ground plane


TEST PROCEDURE
1. The EUT is placed on a turntable, which is 0.8m above ground plane.
2. The turntable shall be rotated for 360 degrees to determine the position of maximum
   emission level.
3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find
   out the highest emissions.
4. Maximum procedure was performed on the six highest emissions to ensure EUT
   compliance.
5. And also, each emission was to be maximized by changing the polarization of
   receiving antenna both horizontal and vertical.
6. Set the spectrum analyzer in the following setting as:
   RBW is set to 10 kHz and VBW is set 300kHz.


TEST RESULTS
No non-compliance noted.

Test Data

                                        Frequency                   20 dB Bandwidth
     Modulation
                                             (MHz)                        (kHz)
       9.6kbps                               908.42                      178.36




                                                Page 14 / 35


            Compliance Certification Services Inc.
                                FCC ID: KFR-ZL7432US   Report No.: T140613N02-RP1


Test Plot

                                  9.6kbps Mode




                                    Page 15 / 35


                 Compliance Certification Services Inc.
                                      FCC ID: KFR-ZL7432US          Report No.: T140613N02-RP1



7.2 BAND EDGES MEASUREMENT
LIMIT
1. In the above emission table, the tighter limit applies at the band edges.
              Frequency                   Field Strength               Field Strength
                 (MHz)                  (μV/m at 3-meter)           (dBμV/m at 3-meter)
                 30-88                           100                           40
                88-216                           150                         43.5
                216-960                          200                           46
              Above 960                          500                           54
2. As shown in Section 15.35(b), for frequencies above 1000 MHz, the above field strength
   limits in paragraphs (a) and (b) of this section are based on average limits. However, the
   peak field strength of any emission shall not exceed the maximum permitted average
   limits specified above by more than 20 dB under any condition of modulation. For
   point-to-point operation under paragraph (b) of this section, the peak field strength shall
   not exceed 2500 millivolts/meter at 3 meters along the antenna azimuth.

TEST CONFIGURATION
                                                           Antenna
                                                            tower


                      3m                                   Horn
                                                          antenna
   EUT
                            4m
                                                          Spectrum
                                                          analyzer


         Turntable               1m
                     0.8m
                                                             Pre-amp



TEST PROCEDURE
1. The EUT is placed on a turntable, which is 0.8m above the ground plane.
2. The turntable shall be rotated for 360 degrees to determine the position of maximum
   emission level.
3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find
   out the highest emission.
4. Set the spectrum analyzer in the following setting in order to capture the lower and
   upper band-edges of the emission:
    (a) PEAK: RBW=VBW=1MHz / Sweep=AUTO
    (b) AVERAGE: Peak Level + Duty Factor
5. Repeat the procedures until all the PEAK and AVERAGE versus polarization are
   measured.
TEST RESULTS
※ After estimate 20dB bandwidth of 1st and last channel ,the declared frequency
  will not invade restrict band. There is no requirement for this test.


                                         Page 16 / 35


                Compliance Certification Services Inc.
                                               FCC ID: KFR-ZL7432US      Report No.: T140613N02-RP1



7.3 DUTY CYCLE

LIMIT
Nil (No dedicated limit specified in the Rules)

MEASUREMENT EQUIPMENT USED
Name of Equipment Manufacturer                        Model      Serial Number Calibration Due
   SPECTRUM
                     R&S                             FSEK 30          835253/002     SEP. 28, 2014
   ANALYZER
Remark: Each piece of equipment is scheduled for calibration once a year.

TEST CONFIGURATION


                                                                          Antenna
                                                                           tower


                               3m                                          Bi-log
                                                                          antenna
         EUT
                                     4m
                                                                         Spectrum
                                                                         analyzer


               Turntable                  1m
                              0.8m




     Reference ground plane


TEST PROCEDURE
1.   Place the EUT on the table and set it in transmitting mode.
2.   Set center frequency of spectrum analyzer = operating frequency.
3.   Set the spectrum analyzer as RBW, VBW=100KHz, Span = 0Hz, a suitable Sweep
     Time.
4.   Repeat above procedures until all frequency measured were complete.

TEST RESULTS
No non-compliance noted.




                                                  Page 17 / 35


            Compliance Certification Services Inc.
                                FCC ID: KFR-ZL7432US          Report No.: T140613N02-RP1



TEST DATA
                        us               Times                 Ton Total Ton time(ms)
Ton1        29659.319             1                   29659.319         29.659
Ton2                              0                     0.000
Ton3                              0                     0.000
Tp                                                                     100.000



      Ton                     29.659
  Tp(Ton+Toff)               100.000
   Duty Cycle                 0.297                    29.659319            %
  Duty Factor                -10.557




                                       Page 18 / 35


            Compliance Certification Services Inc.
                                FCC ID: KFR-ZL7432US   Report No.: T140613N02-RP1



Test Plot
                                       Ton




                                        Tp




                                    Page 19 / 35


             Compliance Certification Services Inc.
                                     FCC ID: KFR-ZL7432US        Report No.: T140613N02-RP1



7.4 SPURIOUS EMISSION

LIMIT
1. In the section 15.249(a):
  Except as provided in paragraph (b) of this section, the field strength of emissions from
  intentional radiators operated within these frequency bands shall comply with the
  following:
                                     Field Strength of
          Fundamental                                                Field Strength of
                                       Fundamental
           Frequency                                                    Harmonics
                                      Field Strength
             (MHz)                                                        (μV/m)
                                          (mV/m)
          902-928 MHz                       50                              500
        2400 - 2483.5 MHz                    50                             500
        5725 - 5875 MHz                      50                             500
        24.0 - 24.25 GHz                      250                             2500
2. Except as provided elsewhere in this Subpart, the emissions from an intentional radiator
   shall not exceed the field strength levels specified in the following table:
             Frequency                    Field Strength            Measurement Distance
                (MHz)                         (μV/m)                            (m)
                30-88                          100*                              3
               88-216                         150*                            3
               216-960                        200*                            3
             Above 960                         500                            3
   Remark: Except as provided in paragraph (g), fundamental emissions from
   intentional radiators operating under this Section shall not be located in the frequency
   bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation
   within these frequency bands is permitted under other sections of this Part, e.g.,
   Sections 15.231 and 15.241.
3. In the above emission table, the tighter limit applies at the band edges.
             Frequency                   Field Strength                 Field Strength
               (MHz)                   (μV/m at 3-meter)             (dBμV/m at 3-meter)
               30-88                            100                           40
               88-216                          150                          43.5
               216-960                         200                           46
             Above 960                         500                           54




                                         Page 20 / 35


              Compliance Certification Services Inc.
                                    FCC ID: KFR-ZL7432US        Report No.: T140613N02-RP1




MEASUREMENT EQUIPMENT USED
                                  Open Area Test Site # 6
   Name of Equipment         Manufacturer          Model      Serial Number     Calibration Due

 TYPE N COAXIAL CABLE          SUHNER             CHA9513              6         DEC. 18, 2014

      BI-LOG Antenna             Sunol              JB1          A070506-2       SEP. 26, 2014

     LOOP ANTENNA                EMCO               6502         8905-2356       JUN. 10, 2015

       Pre-Amplifier              HP               8447F            NCR              NCR

       EMI Receiver              R&S              ESVS10         833206/012      JUN. 26, 2015
                                              SUCOFLEX104P
         RF Cable              SUHNER                           20520/4PEA       NOV. 10, 2014
                                                   EA
       Horn Antenna           Com-Power            AH-118          071032        DEC. 05, 2014
 3116 Double Ridge Antenna
                             ETS-LINDGREN           3116         00078900        DEC. 27, 2014
           (40G)

        Turn Table              Yo Chen             001            ----------       N.C.R.

      Antenna Tower               AR              TP1000A          309874           N.C.R.

         Controller               CT               SC101           ----------       N.C.R.

                             E-INSTRUMENT
         RF Swicth                               ERS-180A        EC1204141          N.C.R
                                TELH LTD

       Power Meter              Anritsu           ML2487A       6K00003888       MAY. 20, 2015

       Power Sensor             Anritsu          MA2491A           33265         MAY. 20, 2015

  Temp./Humidity Chamber        K.SON             THS-M1             242         AUG. 08, 2014

     DC Power Source             LOKO            DSP-5050       L1507009282         N.C.R

     Spectrum Analyzer           R&S                FSU            200789        JUL. 01, 2015

     Spectrum Analyzer           R&S              FSEK 30        835253/002      SEP. 28, 2014

Remark: Each piece of equipment is scheduled for calibration once a year.




                                          Page 21 / 35


             Compliance Certification Services Inc.
                                            FCC ID: KFR-ZL7432US   Report No.: T140613N02-RP1



TEST CONFIGURATION
9kHz ~ 30MHz




                            3m
                                                                      Loop antenna
      EUT

                                                                    Spectrum /
                                                                     Receiver


            Turntable                  1m
                           0.8m




  Reference ground plane

30MHz ~ 1GHz

                                                                    Antenna
                                                                     tower


                            3m                                       Bi-log
                                                                    antenna
      EUT
                                  4m
                                                                   Spectrum
                                                                   analyzer


            Turntable                  1m
                           0.8m




  Reference ground plane




                                               Page 22 / 35


             Compliance Certification Services Inc.
                                   FCC ID: KFR-ZL7432US         Report No.: T140613N02-RP1


Above 1 GHz


                                                             Antenna
                                                              tower


                   3m                                      Horn
                                                          antenna
   EUT
                         4m
                                                             Spectrum
                                                             analyzer


      Turntable               1m
                  0.8m
                                                               Pre-amp




TEST PROCEDURE
7. The EUT is placed on a turntable, which is 0.8m above ground plane.

8. The turntable shall be rotated for 360 degrees to determine the position of maximum
   emission level.

9. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find
   out the highest emissions.

10. Maximum procedure was performed on the six highest emissions to ensure EUT
   compliance.

11. And also, each emission was to be maximized by changing the polarization of
   receiving antenna both horizontal and vertical.

12. Set the spectrum analyzer in the following setting as:

   Below 1GHz:

         RBW=100kHz / VBW=300kHz / Sweep=AUTO

   Above 1GHz:

         (a) PEAK: RBW=VBW=1MHz / Sweep=AUTO
         (b) AVERAGE: Peak Level + Duty Factor

13. Repeat above procedures until the measurements for all frequencies are complete.




                                       Page 23 / 35


                Compliance Certification Services Inc.
                                          FCC ID: KFR-ZL7432US           Report No.: T140613N02-RP1



Below 1 GHz
Operation Mode:          Normal Operation                            Test Date: 2014/06/16
Temperature:             25°C                                        Tested by: Taiyu Cyu
Humidity:                47% RH                                      Polarity:      Ver. / Hor.

Vertical




Remark:
    1.     No emission found between lowest internal used/generated frequency to 30MHz
           (9kHz~30MHz).
    2.     Radiated emissions measured in frequency range from 30 MHz to 1000MHz were made with an
           instrument using peak/quasi-peak detector mode.
    3.     Quasi-peak test would be performed if the peak result were greater than the quasi-peak limit or
           as required by the applicant.
    4.     Measurements above show only up to 6 maximum emissions noted, or would be lesser, with
           “ N/A ” remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the
           applicable limit) and considered that's already beyond the background noise floor.
    5.     Margin (dB) = Remark result (dBuV/m) – Quasi-peak limit (dBuV/m).
    6.     That the limit for signals below 1GHz is a QP limit and peak readings are below the QP limit.
    7.     The fundamental signal is not shown in the test data because measurements at fundamental
           frequency are shown separately and were ignored during the 30 – 1000 MHz scan.




                                               Page 24 / 35


             Compliance Certification Services Inc.
                                       FCC ID: KFR-ZL7432US           Report No.: T140613N02-RP1




Operation Mode:       Normal Operation                            Test Date: 2014/06/16
Temperature:          25°C                                        Tested by: Taiyu Cyu
Humidity:             47% RH                                      Polarity:      Ver. / Hor.

Horizontal




Remark:
   1.   No emission found between lowest internal used/generated frequency to 30MHz
        (9kHz~30MHz).
   2.   Radiated emissions measured in frequency range from 30 MHz to 1000MHz were made with an
        instrument using peak/quasi-peak detector mode.
   3.   Quasi-peak test would be performed if the peak result were greater than the quasi-peak limit or
        as required by the applicant.
   4.   Measurements above show only up to 6 maximum emissions noted, or would be lesser, with
        “ N/A ” remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the
        applicable limit) and considered that's already beyond the background noise floor.
   5.   Margin (dB) = Remark result (dBuV/m) – Quasi-peak limit (dBuV/m).
   6.   That the limit for signals below 1GHz is a QP limit and peak readings are below the QP limit.
   7.   The fundamental signal is not shown in the test data because measurements at fundamental
        frequency are shown separately and were ignored during the 30 – 1000 MHz scan.




                                            Page 25 / 35


               Compliance Certification Services Inc.
                                      FCC ID: KFR-ZL7432US          Report No.: T140613N02-RP1



The fundamental signal

Operation Mode: TX / 9.6kbps Mode (Z axis)                    Test Date: 2014/06/26
Temperature:         26.4°C                                   Tested by: Ted Huang
Humidity:            56% RH                                   Polarity:        Ver. / Hor.


Horizontal
                              Cable
  Freq.    Reading    AF              Pre-amp   Filter    Level       Limit        Margin     Mark
                              Loss
 (MHz)     (dBμV)    (dB/m)   (dB)     (dB)     (dB)     (dBμV/m) (dBμV/m)          (dB)     (P/Q/A)

 908.42      86.56   23.11    5.95     24.41    0.00      91.21       114.00       -22.79      P
 908.42      86.56   23.11    5.95     24.41    0.00      91.21       94.00         -2.79      Q


Vertical
                              Cable
  Freq.    Reading    AF              Pre-amp   Filter    Level        Limit       Margin     Mark
                              Loss
 (MHz)     (dBμV)    (dB/m)   (dB)     (dB)     (dB)     (dBμV/m)    (dBμV/m)       (dB)     (P/Q/A)
 908.42      83.23   23.11    5.95     24.41    0.00      87.88       114.00       -26.12      P
 908.42      83.23   23.11    5.95     24.41    0.00      87.88        94.00        -6.12      Q

Remark:
 Margin (dB) = Remark result (dBuV/m) – Quasi-peak limit (dBuV/m).




                                          Page 26 / 35


                 Compliance Certification Services Inc.
                                        FCC ID: KFR-ZL7432US          Report No.: T140613N02-RP1



  Above 1 GHz


  Operation Mode: TX / 9.6kbps Mode (Z axis)                       Test Date: 2014/06/26
  Temperature:         26.4°C                                      Tested by: Ted Huang
  Humidity:            56% RH                                      Polarity:     Ver. / Hor.


  Horizontal
                                Cable
    Freq.   Reading     AF              Pre-amp   Filter    Level        Limit      Margin      Mark
                                Loss
   (MHz)    (dBμV)     (dB/m)   (dB)     (dB)     (dB)     (dBμV/m) (dBμV/m)         (dB)      (P/Q/A)

  1816.83      64.49   29.14    2.21     48.33    0.30      47.81        74.00      -26.19       P
  1816.83      53.93   29.14    2.21     48.33    0.30      37.26        54.00      -16.74       A
* 2725.23      55.72   30.38    2.77     47.29    0.30      41.88        74.00      -32.12       P
* 2725.23      45.16   30.38    2.77     47.29    0.30      31.32        54.00      -22.68       A
* 3633.58      56.84   31.04    3.23     47.60    0.30      43.81        74.00      -30.19       P
* 3633.58      46.28   31.04    3.23     47.60    0.30      33.25        54.00      -20.75       A
    N/A         ---     ---      ---      ---      ---       ---          ---         ---        ---

  Remark:
  1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency.
  2. Radiated emissions measured in frequency above 1000MHz were made with an instrument
     using peak/average detector mode.
  3. Average test would be performed if the peak result were greater than the average limit or as
     required by the applicant.
  4. Data of measurement within this frequency range shown “ --- ” in the table above means the
     reading of emissions are attenuated more than 20dB below the permissible limits or the field
     strength is too small to be measured.
  5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with
     “ N/A ” remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the
     applicable limit) and considered that's already beyond the background noise floor.
  6. Margin (dB) = Remark result (dBuV/m) – Average limit (dBuV/m). Peak detector mode and
     average detector mode of the emission shown in Result column.




                                            Page 27 / 35


                Compliance Certification Services Inc.
                                        FCC ID: KFR-ZL7432US          Report No.: T140613N02-RP1




  Operation Mode: TX / 9.6kbps Mode (Z axis)                       Test Date: 2014/06/26
  Temperature:         26.4°C                                      Tested by: Ted Huang
  Humidity:            56% RH                                      Polarity:     Ver. / Hor.
  Vertical
                                Cable
    Freq.    Reading    AF              Pre-amp   Filter    Level        Limit      Margin      Mark
                                Loss
   (MHz)     (dBμV)    (dB/m)   (dB)     (dB)     (dB)     (dBμV/m)    (dBμV/m)       (dB)     (P/Q/A)
  1816.70     66.86    29.14    2.21     48.33    0.30      50.18        74.00       -23.82      P
  1816.70     56.30    29.14    2.21     48.33    0.30      39.63        54.00       -14.37      A
* 2725.16     54.64    30.38    2.77     47.29    0.30      40.80        74.00       -33.20      P
* 2725.16     44.08    30.38    2.77     47.29    0.30      30.24        54.00       -23.76      A
* 3633.62     57.56    31.04    3.23     47.60    0.30      44.53        74.00       -29.47      P
* 3633.62     47.00    31.04    3.23     47.60    0.30      33.97        54.00       -20.03      A
    N/A        ---      ---      ---      ---      ---       ---          ---          ---       ---

  Remark:
  1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency.
  2. Radiated emissions measured in frequency above 1000MHz were made with an instrument
     using peak/average detector mode.
  3. Average test would be performed if the peak result were greater than the average limit or as
     required by the applicant.
  4. Data of measurement within this frequency range shown “ --- ” in the table above means the
     reading of emissions are attenuated more than 20dB below the permissible limits or the field
     strength is too small to be measured.
  5. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with
     “ N/A ” remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the
     applicable limit) and considered that's already beyond the background noise floor.
  6. Margin (dB) = Remark result (dBuV/m) – Average limit (dBuV/m). Peak detector mode and
     average detector mode of the emission shown in Result column.




                                            Page 28 / 35


              Compliance Certification Services Inc.
                                    FCC ID: KFR-ZL7432US       Report No.: T140613N02-RP1



7.5   POWERLINE CONDUCTED EMISSIONS

LIMIT
According to §15.207(a), except as shown in paragraphs (b) and (c) of this section, for an
intentional radiator that is designed to be connected to the public utility (AC) power line,
the radio frequency voltage that is conducted back onto the AC power line on any
frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed the limits
in the following table, as measured using a 50 µH/50 ohms line impedance stabilization
network (LISN). Compliance with the provisions of this paragraph shall be based on the
measurement of the radio frequency voltage between each power line and ground at the
power terminal. The lower limit applies at the boundary between the frequency ranges.

                                                           Limits
      Frequency Range                                     (dBμV)
           (MHz)
                                           Quasi-peak                    Average
          0.15 to 0.50                      66 to 56                     56 to 46
            0.50 to 5                         56                            46
             5 to 30                          60                            50
Compliance with this provision shall be based on the measurement of the radio
frequency voltage between each power line (LINE and NEUTRAL) and ground at the
power terminals.

MEASUREMENT EQUIPMENT USED
                              Conducted Emission room #1
Name of Equipment        Manufacturer          Model     Serial Number Calibration Due
                         SCHWARZBECK         NNLK 8130        8130124         AUG. 12, 2014

        L.I.S.N.         Rohde & Schwarz      ESH 3-Z5      840062/021        SEP. 09, 2014

                         Rohde & Schwarz      ESH 3-Z5      893540/015        APR. 13, 2015

   TEST RECEIVER         Rohde & Schwarz      ESCS 30         100348          AUG. 09, 2014

 BNC COAXIAL CABLE            CCS              BNC50            11            NOV. 19, 2014

      Test S/W                               e-3 (5.04211c) R&S (2.27)
Remark: Each piece of equipment is scheduled for calibration once a year.

TEST RESULTS
  No non-compliance noted.




                                        Page 29 / 35


             Compliance Certification Services Inc.
                                   FCC ID: KFR-ZL7432US       Report No.: T140613N02-RP1




   Product Name        In-Wall Switch 2 Relays        Test Date          2014/06/17
    Model Name               ZL7432US                 Test By             Rock Guo
       Test Mode          Normal Operation       Temp & Humidity         25.2℃, 53%


LINE




 Remark 1: Level (dBuV/m) = Read Level (dBuV) + LISN Factor (dB/m) + Cable Loss (dB)
         2: Over Limit value(dB) = Level (dBuV/m) – Limit Line(dBuV/m)




                                       Page 30 / 35


           Compliance Certification Services Inc.
                                 FCC ID: KFR-ZL7432US         Report No.: T140613N02-RP1




 Product Name      In-Wall Switch 2 Relays          Test Date           2014/06/17
  Model Name              ZL7432US                  Test By              Rock Guo
   Test Mode          Normal Operation        Temp & Humidity           25.2℃, 53%


NEUTRAL




Remark 1: Level (dBuV/m) = Read Level (dBuV) + LISN Factor (dB/m) + Cable Loss (dB)
       2: Over Limit value(dB) = Level (dBuV/m) – Limit Line(dBuV/m)




                                     Page 31 / 35



Document Created: 2014-07-14 14:03:07
Document Modified: 2014-07-14 14:03:07

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC