TEST REPORT

FCC ID: KE3IF100A

Test Report

Download: PDF
FCCID_4338296

S
                                      FCC TEST REPORT
T                                      Report No: STS1905273W01


S                                                      Issued for

                                              Radio Systems Corp

                 10427 PetSafe Way Knoxville, Tennessee 37932 United
                                      States




L                           Product Name: Wireless Pet Containment Transmitter

                               Brand Name: PetSafe, Premier Pet




A
                              Model Name: RFA-584

                              Series Model: RFA-443, IF-100

                                      FCC ID: KE3IF100A



B                           Test Standard: FCC Part 15 Subpart C




    Any reproduction of this document must be done in full. No single part of this document may be reproduced without
    permission from STS, All Test Data Presented in this report is only applicable to presented Test sample.

    Shenzhen STS Test Services Co., Ltd.
    1/F., Building B, Zhuoke Science Park, No.190, Chongqing Road,
    Fuyong Street, Bao’an District, Shenzhen, Guangdong, China
    TEL: +86-755 3688 6288 FAX: +86-755 3688 6277 E-mail:sts@stsapp.com


                                                    Page 2 of 20              Report No.: STS1905273W01


                                      TEST RESULT CERTIFICATION

Applicant’s Name ................... : Radio Systems Corp

Address .................................. : 10427 PetSafe Way Knoxville, Tennessee 37932 United States

Manufacture's Name .............. : Radio Systems Corp
Address .................................. : 10427 PetSafe Way Knoxville, Tennessee 37932 United States

Product Description

Product Name ........................ : Wireless Pet Containment Transmitter

Brand Name ........................... : PetSafe, Premier Pet

Model Name ........................... : RFA-584

SeriesModel ........................... : RFA-443, IF-100

Test Standards ...................... : FCC Part 15 Subpart C

Test Procedure ....................... : ANSI C63.10-2013

This device described above has been tested by STS, the test results show that the equipment
under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested
sample identified in the report.
This report shall not be reproduced except in full, without the written approval of STS, this document
only be altered or revised by STS, personal only, and shall be noted in the revision of the document.

Date of performance of tests…....: 30 May 2019 ~25 June 2019

Date of Issue ………………….…: 25 June 2019

Test Result………………………...: Pass



                   Testing Engineer         :

                                                                (ChrisChen)



                   Technical Manager        :

                                                                (Sunday Hu)


                   Authorized Signatory :

                                                                  (Vita Li)


                                   Page 3 of 20    Report No.: STS1905273W01



                         Table of Contents                          Page



1. SUMMARY OF TEST RESULTS                                            5
  1.1 TEST FACTORY                                                    5
  1.2 MEASUREMENT UNCERTAINTY                                         5

2. GENERAL INFORMATION                                                6
  2.1 GENERAL DESCRIPTION OF THE EUT                                  6
  2.2 DESCRIPTION OF THE TEST MODES                                   7
  2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED         8
  2.4 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS          8
  2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS                              9

3.CONDUCTED EMISSION TEST RESULT(SECTION 15.207)                     10
  3.1 POWER LINE CONDUCTED EMISSION LIMITS                           10
  3.2 TEST PROCEDURE                                                  11
  3.3 TEST SETUP                                                      11
  3.4 EUT OPERATING CONDITIONS                                        11
  3.5 TEST RESULTS                                                   12

4. RADIATED&FIELD EMISSION TEST RESULT(SECTIOU 15.209)               14
  4.1 LIMIT                                                          14
  4.2 TEST PROCEDURE                                                 14
  4.3 TEST SETUP                                                     15
  4.4 TEST RESULTS                                                   16

5.20 DB BANDWIDTH TEST                                               19
  5.1 LIMIT                                                          19
  5.2 TEST SETUP                                                     19
  5.3 TEST RESULTS                                                   19

APPENDIX-PHOTOS OF TEST SETUP                                        20


                                Page 4 of 20           Report No.: STS1905273W01


                            Revision History


Rev.    Issue Date      Report NO.       Effect Page            Contents

00     25 June 2019   STS1905273W01            ALL             Initial Issue


                                            Page 5 of 20           Report No.: STS1905273W01


1. SUMMARY OF TEST RESULTS
Test procedures according to the technical standards:

                                  FCC Part15 , Subpart C
        Standard
                                        Test Item                   Judgment        Remark
         Section
         15.207                    Conducted Emission                PASS

      15.209(a)           Radiated emission, Spurious Emission       PASS

         2.1049                     20 dB Bandwidth                  PASS


1.1 TEST FACTORY
   Shenzhen STS Test Services Co., Ltd.
   Add. : 1/F., Building B, Zhuoke Science Park, No.190, Chongqing Road,
   Fuyong Street, Bao’an District, Shenzhen, Guangdong,China
  FCC test Firm Registration Number: 625569
  A2LA Certificate No.: 4338.01

1.2 MEASUREMENT UNCERTAINTY
  The reported uncertainty of measurement y ±U,where expended uncertainty U is based on a
  standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
  approximately 95 %.

                   No.                          Item                       Uncertainly
                   1                RF output power,conducted               ±0.71dB
                   2              Unwanted Emissions,conducted              ±0.63dB
                   3             All emissions,radiated 30-200MHz           ±3.43dB
                   4            All emissions,radiated 200MHz-1GHz          ±3.57dB
                   5                 All emissions,radiated>1G              ±4.13dB
                   6            Conducted Emission(9KHz-150KHz)             ±3.18dB
                   7           Conducted Emission(150KHz-30MHz)             ±2.70dB


                                              Page 6 of 20            Report No.: STS1905273W01


2. GENERAL INFORMATION
2.1 GENERAL DESCRIPTION OF THE EUT

           Product Name                       Wireless Pet Containment Transmitter
           Trade Name                         PetSafe, Premier Pet
           Model Name                         RFA-584
           Series Model                       RFA-443, IF-100
           Model Difference                   Only different in model name and brand name.
           Channel List                       Please refer to the Note 2.
           Equipemnt Category                 Non-ISM frequency
           Operating frequency                18.72KHz
           Modulation Type                    Phase
                                              Input:100-240V,50/60Hz 0.8A Max
           Adapter:
                                              Output:19V,1.26A
           Hardware version number            001
           Software version number            001
           Connecting I/O Port(s)             Please refer to the User’s Manual
Note:
    1. For a more detailed features description, please refer to the manufacturer’s specifications
       or the User’s Manual.
    2.
                                             Channel List
                           Frequency                 Frequency                     Frequency
           Channel                      Channel                      Channel
                             (KHz)                     (KHz)                          (KHz)
              00             18.72
    3. Table for Filed Antenna
         Ant.        Brand      Model Name Antenna Type Connector                   NOTE

                                                      203mm
                  PetSafe,
          1                         RFA-584         diameter air     N/A             Antenna
                 Premier Pet
                                                        coil


                                           Page 7 of 20             Report No.: STS1905273W01


2.2 DESCRIPTION OF THE TEST MODES
    To investigate the maximum EMI emission characteristics generates from EUT, the test system
    was pre-scanning tested base on the consideration of following EUT operation mode or test
    configuration mode which possible have effect on EMI emission level. Each of these EUT
    operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.

             Pretest Mode                             Description
               Mode 1                             Charging+TX Mode

                                    For Conducted Emission

           Final Test Mode                            Description

               Mode 1                             Charging+TX Mode


                                     For Radiated Emission

           Final Test Mode                            Description

               Mode 1                             Charging+TX Mode


                                             Page 8 of 20            Report No.: STS1905273W01


 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED
 During testing channel & power controlling software provided by the customer was used to control
 the operating channel as well as the output power level. The RF output power selection is for the
 setting of RF output power expected by the customer and is going to be fixed on the firmware of
 the final end product power parameters

Radiated Emission Test


                                   C-1                     AC Plug
                       E-1                      E-2
                       EUT                    Adapter




Conducted Emission Test


               AC Plug         E-2         C-1
                                                          E-1
                             Adapter                      EUT




 2.4 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS
 The EUT has been tested as an independent unit together with other necessary accessories or
 support units. The following support units or accessories were used to form a representative test
 configuration during the tests.
                                       Necessary accessories
 Item      Equipment           Mfr/Brand        Model/Type No.           Serial No.         Note

  E-2        Adapter             N/A         NF19V-1.26C-DC                 N/A              N/A

  C-1       DC Cable             N/A                N/A                     N/A              N/A




                                           Support units
                                             Model/Type
  Item      Equipment          Mfr/Brand                             Serial No.             Note
                                                  No.

  N/A          N/A                N/A             N/A                   N/A                 N/A




   Note:
    (1)    FCC DOC approved.
    (2)    FTP is Foiled Twisted Pair.


                                        Page 9 of 20            Report No.: STS1905273W01


 2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS
Radiation Test equipment
                                                                         Last     Calibrated
Kind of Equipment   Manufacturer   Type No.       Serial No.
                                                                    calibration      until
  Test Receiver        R&S           ESCI          101427           2018.10.13    2019.10.12
 Signal Analyzer      Agilent       N9020A       MY51110105         2019.03.02    2020.03.01
   Active loop
                      ZHINAN       ZN30900C            16035        2018.03.11    2021.03.10
    Antenna
  Bilog Antenna       TESEQ        CBL6111D            34678        2017.11.02    2020.11.1
  Pre-Amplifier
                        EM          EM330          060665           2018.10.13    2019.10.12
  (0.1M-3GHz)
 Temperature &
                      HH660          Mieo               N/A         2018.10.11    2019.10.10
    Humidity

    Test SW           BULUN                             BL410-E/18.905

Conduction Test equipment
                                                                         Last     Calibrated
Kind of Equipment   Manufacturer   Type No.       Serial No.
                                                                    calibration      until
  Test Receiver        R&S           ESCI          101427           2018.10.13    2019.10.12
      LISN             R&S         ENV216          101242           2018.10.11    2019.10.10
      LISN            EMCO         3810/2NM            23625        2018.10.11    2019.10.10
 Temperature &
                      HH660          Mieo               N/A         2018.10.11    2019.10.10
    Humidity

    Test SW           FARAD                   EZ-EMC(Ver.STSLAB-03A1 CE)


                                              Page 10 of 20            Report No.: STS1905273W01


3.CONDUCTED EMISSION TEST RESULT(SECTION 15.207)
3.1 POWER LINE CONDUCTED EMISSION LIMITS
Operating frequency band. In case the emission fall within the restricted band specified on Part
15.207 limit in the table below has to be followed.

                                                               Class B (dBuV)
                 FREQUENCY (MHz)
                                                     Quasi-peak             Average
                        0.15 -0.5                     66 - 56 *             56 - 46 *
                        0.50 -5.0                      56.00                    46.00
                        5.0 -30.0                      60.00                    50.00
      Note:
        (1) The tighter limit applies at the band edges.
        (2) The limit of " * " marked band means the limitation decreases linearly with the
            logarithm of the frequency in the range.

The following table is the setting of the receiver
             Receiver Parameters                                        Setting
                   Attenuation                                           10 dB
                 Start Frequency                                       0.15 MHz
                 Stop Frequency                                         30 MHz
                  IF Bandwidth                                           9 kHz


                                            Page 11 of 20            Report No.: STS1905273W01


3.2 TEST PROCEDURE
 a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected
    to the power mains through a line impedance stabilization network (LISN). All other support
    equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
    impedance for the measuring instrument.
 b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
    and forth in the center forming a bundle 30 to 40 cm long.
 c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
    cable may be terminated, if required, using the correct terminating impedance. The overall
    length shall not exceed 1 m.
 d. LISN at least 80 cm from nearest part of EUT chassis.
 e. For the actual test configuration, please refer to the related Item –EUT Test Photos.


3.3 TEST SETUP
                      Vertical Reference
                      Ground Plane                                            Test Receiver


                      EUT
       40cm




                                                80cm
       LISN




                                                              Horizontal Reference
                                                              Ground Plane

         Note: 1.Support units were connected to second LISN.
                 2.Both of LISNs (AMN) are 80 cm from EUT and at least 80
          cm       from other units and other metal planes
            support.    units.



3.4 EUT OPERATING CONDITIONS
The EUT was configured for testing in a typical fashion (as a customer would normally use it). The
EUT has been programmed to continuously transmit during test. This operating condition was
tested and used to collect the included data.


                                           Page 12 of 20              Report No.: STS1905273W01


3.5 TEST RESULTS

                                                       Relative
Temperature:          25.4℃                                                65%
                                                       Humidity:
Test Voltage:         AC 120V/60Hz                     Phase:              L

Test Mode:            Mode 1



          Frequency           Reading   Factor     Result         Limit          Margin
  No.                                                                                     Detector
            (MHz)             (dBuV)     (dB)      (dBuV)       (dBuV/m)          (dB)
   1        0.3620             29.67    20.58       50.25         58.68          -8.43      QP
   2         0.3620            24.68    20.58      45.26           48.68         -3.42     AVG
   3         0.9700            15.79    20.17      35.96           56.00         -20.04     QP
   4         0.9700            7.63     20.17      27.80           46.00         -18.20    AVG
   5         1.4820            16.15    20.11      36.26           56.00         -19.74     QP
   6         1.4820            7.35     20.11      27.46           46.00         -18.54    AVG
   7         2.2020            15.68    20.04      35.72           56.00         -20.28     QP
   8         2.2020            5.88     20.04      25.92           46.00         -20.08    AVG
   9         4.2220            14.34    19.95      34.29           56.00         -21.71     QP
  10         4.2220            4.11     19.95      24.06           46.00         -21.94    AVG
  11         7.6340            13.00    19.95      32.95           60.00         -27.05     QP
  12         7.6340            1.42     19.95      21.37           50.00         -28.63    AVG


Remark:
1. All readings are Quasi-Peak and Average values.
2. Margin = Result (Result =Reading + Factor )–Limit


                                            Page 13 of 20          Report No.: STS1905273W01


                                                       Relative
Temperature:           25.4℃                                            65%
                                                       Humidity:
Test Voltage:          AC 120V/60Hz                    Phase:           N

Test Mode:             Mode 1


           Frequency           Reading   Factor    Result      Limit          Margin
  No.                                                                                  Detector
             (MHz)             (dBuV)     (dB)     (dBuV)    (dBuV/m)          (dB)
   1         0.3620             29.38    20.58      49.96      58.68          -8.72      QP
   2         0.3620             19.25    20.58      39.83       48.68         -8.85     AVG
   3         0.7460             14.53    20.24      34.77       56.00         -21.23     QP
   4         0.7460             4.67     20.24      24.91       46.00         -21.09    AVG
   5         1.6700             13.22    20.10      33.32       56.00         -22.68     QP
   6         1.6700             3.81     20.10      23.91       46.00         -22.09    AVG
   7         3.7140             13.07    19.95      33.02       56.00         -22.98     QP
   8         3.7140             1.90     19.95      21.85       46.00         -24.15    AVG
   9         7.9780             10.06    19.97      30.03       60.00         -29.97     QP
   10        7.9780             -1.07    19.97      18.90       50.00         -31.10    AVG
   11        29.2420            8.01     19.38      27.39       60.00         -32.61     QP
   12        29.2420            -3.14    19.38      16.24       50.00         -33.76    AVG

Remark:
1. All readings are Quasi-Peak and Average values.
2. Margin = Result (Result =Reading + Factor )–Limit


                                             Page 14 of 20            Report No.: STS1905273W01


4. RADIATED&FIELD EMISSION TEST RESULT(SECTIOU 15.209)
4.1 Limit
                Frequency                    Field Strength             Measurement Distance
                   [MHz]                         [uV/m]                       [Meters]
              0.009 ~ 0.490                   2400/F (kHz)                      300
              0.490 ~ 1.705                  24000/F (kHz)                       30
                1.705 ~ 30                          30                           30
                  30 ~ 88                          100                            3
                 88 ~ 216                          150                            3
                216 ~ 960                          200                            3
               Above 960                           500                            3
Note:

   (1)   The limit for radiated test was performed according to FCC PART 15C.

   (2)   The tighter limit applies at the band edges.

   (3)   Emission level (dBuV/m)=20log Emission level (uV/m).



            Receiver Parameter                                     Setting
                Attenuation                                         Auto
         Start ~ Stop Frequency                          9kHz~90kHz / RB 200Hz forAV
         Start ~ Stop Frequency                      90kHz~110kHz / RB 200Hz for QP
         Start ~ Stop Frequency                    110kHz~490kHz / RB 200Hz/9kHz for AV
         Start ~ Stop Frequency                         490kHz~30MHz / RB 9kHz for QP
         Start ~ Stop Frequency                    30MHz~1000MHz / RB 120kHz for QP
§15.209(d)The emission limits shown in the above table are based on measurements employing a
 CISPR quasi-peak detector except for the frequency bands 9-90 kHz, 110-490 kHz and above
 1000 MHz. Radiated emission limits in these three bands are based on measurements employing
 an average detector.

4.2 TEST PROCEDURE
 a. The measuring distance of at 3 m shall be used for measurements at frequency 0.009MHz up
    to 1GHz.
 b. The EUT was placed on the top of a rotating table 0.8 meter above the ground at a 3 meter
    anechoic chamber. The table was rotated 360 degrees to determine the position of the highest
    radiation.
 c. The initial step in collecting conducted emission data is a spectrum analyzer peak detector
    mode pre-scanning the measurement frequency range. Significant peaks are then marked and
    then Quasi Peak detector mode re-measured.
 d. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
    EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement
    performed.
 e. For the actual test configuration, please refer to the related Item –EUT Test Photos.
    Note:
    Both horizontal and vertical antenna polarities were testedand performed pretest to three
    orthogonal axis. The worst case emissions were reported.


                                    Page 15 of 20    Report No.: STS1905273W01


4.3 TEST SETUP
(A)Radiated Emission Test-Up Frequency Below 30MHz




(B)Radiated Emission Test-Up Frequency 30MHz~1GHz


                                            Page 16 of 20             Report No.: STS1905273W01


4.4 TEST RESULTS
Temperature:      22.7℃                              Relative Humidity: 61%
Test Voltage :    AC 120V/60Hz                       Test Mode :        TX Mode

4.4.1 Spurious Radiated Emission Below 30 MHz

                                             Ant.
 Frequency Reading           Detector                    Cable     Emission     Limits      Margin
                                            Factor
                                                                     Level
   (KHz)         (dBμV)    (PK/QP/AV)       (dB/m)       Loss               (dBμV/m)          (dB)
                                                                   (dBμV/m)
    18.72         96.7          PK           26.27        0.1       123.07      142.16       -19.09
   18.72         80.35          AV           26.27        0.1       106.72      122.16       -15.44
     36          70.31          PK           22.03        0.1        92.44      136.48       -44.04
     36          55.41          AV           22.03        0.1        77.54      116.48       -38.94
    110          77.68          PK           10.04        0.1        87.82      126.78       -38.96
    110          62.37          AV           10.04        0.1        72.51      106.78       -34.27
    205          75.06          PK            9.43        0.1        84.59      121.37       -36.78
    205          59.47          AV            9.43        0.1        69.00      101.37       -32.37
    495          64.54          QP            1.15        0.1        65.79       73.71        -7.92
   21735         69.23          QP           -17.9        0.9        52.23       69.54       -17.31

1. “*” Means Fundamental frequency
2. Emission Level [dBμV/m] = Reading [dBμV] + Ant. Factor [dB/m] + Cable Loss [dB]
3.Margin [dB] = Emission Level [dBμV/m] – Limit [dBμV/m]
4.Limit calculation: Limit at specified distance + 40log (300/3) = Limit + 80 dB for up to 0.49 MHz
  Limit at specified distance + 40log (30/3) = Limit + 40 dB for above 0.49 MHz, Below 30 MHz
5.During the radiated emission test, the measurement antenna was aligned along the site axis and
  orthogonal to the axis, only the worst-case data recorded.


                                              Page 17 of 20           Report No.: STS1905273W01



 4.4.2 Spurious Radiated Emission below 1 GHz
Temperature:       23.4℃                            Relative Humidity: 58%
Test Voltage :     AC 120V/60Hz                     Test Mode :            Mode 1

  The following table shows the highest levels of radiated emissions on polarizations of vertical
  Frequency       Reading         Correct          Result          Limit        Margin     Remark
     (MHz)         (dBuV)      Factor(dB/m)       (dBuV/m)       (dBuV/m)           (dB)

    45.8551        44.07          -19.34           24.73           40.00        -15.27       QP

    71.8320        54.93          -23.84           31.09           40.00        -8.91        QP

   141.8262        52.67          -17.59           35.08           43.50        -8.42        QP

   374.6225        48.98          -12.77           36.21           46.00        -9.79        QP

   468.8761        47.59          -10.16           37.43           46.00        -8.57        QP

   912.8620        33.69           -1.82           31.87           46.00        -14.13       QP

Remark:
1. Margin = Result (Result =Reading + Factor )–Limit


                                           Page 18 of 20            Report No.: STS1905273W01



Temperature:      23.4℃                            Relative Humidity: 58%
Test Voltage :    AC 120V/60Hz                     Test Mode :            Mode 1

 The following table shows the highest levels of radiated emissions on polarizations of horizontal
  Frequency      Reading         Correct          Result          Limit        Margin     Remark
    (MHz)         (dBuV)      Factor(dB/m)      (dBuV/m)        (dBuV/m)           (dB)

   43.0504         41.95         -17.90           24.05           40.00        -15.95       QP

   59.8588         50.49         -24.30           26.19           40.00        -13.81       QP

  178.1322         48.82         -19.42           29.40           43.50        -14.10       QP

  368.1116         43.18         -12.94           30.24           46.00        -15.76       QP

  552.8831         37.62          -6.71           30.91           46.00        -15.09       QP

  906.4823         33.92          -2.05           31.87           46.00        -14.13       QP

Remark:
1. Margin = Result (Result =Reading + Factor )–Limit


                                            Page 19 of 20          Report No.: STS1905273W01


5.20 DB BANDWIDTH TEST
 5.1 Limit
     FCC Part 2.1049, Only applicable to report.


 5.2 TEST SETUP
      Spectrum Parameter                                      Setting
        Span Frequency                    approximately 2 to 3 times the 20 dB bandwidth
              RB                             greater than 1 % of the 20 dB bandwidth,
              VB                                         equal to the RBW
            Detector                                           Peak
             Trace                                           Max Hold
          Sweep Time                                            Auto
 The test program and configuration,Refer to 4.2 and 4.3


 5.3 TEST RESULTS

              OperatingFrequency(kHz)                            20 dB Bandwhidth(Hz)

                         18.72                                            281

                                              CH00


                                           Page 20 of 20           Report No.: STS1905273W01


APPENDIX-PHOTOS OF TEST SETUP
Note:See test photos in setup photo document for the actual connections between Product and
support equipment.




                          ※※※※※END OF THE REPORT※※※※※



Document Created: 2019-06-28 19:08:13
Document Modified: 2019-06-28 19:08:13

© 2024 FCC.report